Professional Documents
Culture Documents
, Point Lisas
Industrial Estate, Couva, Trinidad, West Indies
Ph: (868) 679-1573 / (868) 636-3201
Fax: (868) 636-6175 • www.tistt.com
TEST DETAILS
Material Surface Condition Weld Process Type
Wet Dry
Carbon Steel Visible
☒ ☐
Clean SMAW
Wet Dry
Thickness N/A Fluorescent
☐ ☐
Procedure Acceptance Criteria Equipment Current Type
WI-OPR-MPI-1A AWS D1.1 AC Yoke AC – 10 LBS ☐
S/N DC – 40 LBS ☒
Field Adequacy and
Background Lighting Technique
Direction
Longitudinal Indirect Magnetic Particle Field
White Contrast Natural
Continuous Method Indicator
TEST RESULTS
Results Photograph
PASS ☒ FAIL ☐
Reviewed By
Inspected By
Kerron Dhoray Stephan Pustam
SNT-TC-1A Level II MT Integrity Engineer I
INTEGRITY MATTERS
DR-OPR-MPI-1A
DR-OPR-MPI-1A – Defect Description Sheet
Issue Date: 21st September 2018
Rev Date: 12th December 2019
Rev No.: 01
Corner Pacific Ave. & Caribbean Dr., Point Lisas
Industrial Estate, Couva, Trinidad, West Indies
Ph: (868) 679-1573 / (868) 636-3201
Fax: (868) 636-6175 • www.tistt.com
Pad Eye 1
Pad Eye 2
INTEGRITY MATTERS
DR-OPR-MPI-1A
DR-OPR-MPI-1A – Defect Description Sheet
Issue Date: 21st September 2018
Rev Date: 12th December 2019
Rev No.: 01
Corner Pacific Ave. & Caribbean Dr., Point Lisas
Industrial Estate, Couva, Trinidad, West Indies
Ph: (868) 679-1573 / (868) 636-3201
Fax: (868) 636-6175 • www.tistt.com
Pad Eye 3
Pad Eye 4
INTEGRITY MATTERS
DR-OPR-MPI-1A
DR-OPR-MPI-1A – Defect Description Sheet
Issue Date: 21st September 2018
Rev Date: 12th December 2019
Rev No.: 01