You are on page 1of 2

PROJECT TITLE:

LOCATION:
OWNER:
DATE RELEASED: 4/12/2018

BUILDING NAME:
NSCP 2015: Section 207B: Wind Load (kPa) on Pitched Free Roofs: Open Buildings

qz = 0.613KzKztKdV2 Equation 207C.3-1 BLDG. CATEGORY: BLDG. DIM.: WIND FLOW:


Kzt= 1 Figure 207A.8-1 CATEGORY IV L= 48.00 m CLEAR
Kd = 0.85 Tables 207A.6-1 Table 103-1 B= 12.00 m LIMITS:
V= 75.00 m/s Figure 207A.5-1A, B or C BLDG. EXPOSURE: h= 12.00 m h/L= 0.25
G= 0.85 Section 207A.9 EXPOSURE D ϴ= 7.50 deg h/B= 1.00

Computation of qhG Input values as follows: B


= Horizontal dimension of structure parallel to ridge L
mean roof height (h) N/A qh G qh G = Horizontal dimension of structure normal to ridge
12.00 m 1.22 3.58 kPa 0.85 3.04 kPa
Roof Pressure, qhGCN
Roof Angle Wind Direction, ɣ = 0⁰, 180⁰
Load Case
ϴ Clear Wind Flow Obstructed Wind Flow
CN CNW CNL CNW CNL
A 1.1 -0.3 N/A N/A
7.50 deg
B 0.2 -1.2 N/A N/A
qhGCN qhCNW qhCNL qhCNW qhCNL
A 3.34 kPa -0.91 kPa N/A N/A
7.50 deg
B 0.61 kPa -3.65 kPa N/A N/A
Roof Pressure, qhGCN
Wind Direction, ɣ = 90⁰, 270⁰

Horizontal Distance from Windward Clear Wind Flow Obstructed Wind Flow
Roof Angle ϴ Load Case
Edge
CNW qhCNW CNL qhCNL
All Shapes A -0.8 -2.43 kPa N/A N/A
0.00 m to 12.00 m
ϴ ≤ 45⁰ B 0.8 2.43 kPa N/A N/A
All Shapes A -0.6 -1.82 kPa N/A N/A
12.00 m to 12.00 m
ϴ ≤ 45⁰ B 0.5 1.52 kPa N/A N/A
All Shapes A -0.3 -0.91 kPa N/A N/A
12.00 m to 12.00 m
ϴ ≤ 45⁰ B 0.3 0.91 kPa N/A N/A
CATEGORY I
CATEGORY II
CATEGORY III
CATEGORY IV
CATEGORY V

EXPOSURE B
EXPOSURE C
EXPOSURE D