A DVANCED APPLICATIONS
1. Overview
2. File opening and Preferences setting
3. Checking Model Data
4. Reinforcement Input
5. Performing Structural Analysis
6. PSC Section Design
7. Checking Design Results
2
P SC Design as per EN1992-2:05
Overview
Design procedure for PSC section is as follows.
Modeling
Structural Analysis
2. PSC section design can be performed for the beam elements only. All the
elements which are on the X-Y plane are t aken as Beam members and
those with some inclination to X-Y plane are designat ed as Column
members by the midas Civil. However, these automatically assigned
member types to elements can be modified using Modify Member Type
3
A DVANCED APPLICATIONS
125.000
40.000 4.000 4.000 37.000 4.000 4.000 32.000
L OF PIERC L OF PIERC
시 공 방 향 Direction
Construction Construction
시공이음부 Joint 시공이음부
P2 RP2 RP1 Construction Joint A1
4
125.000
L OF PIERC L OF PIERC
L=49.500X1개소X19EA=940.500 CABLE "1" - (15.24mm - 19EA) L=46.500X1개소X19EA=883.500 CABLE "9" - (15.24mm - 19EA) L=33.500X1개소X19EA=636.500 CABLE "17" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "2" - (15.24mm - 19EA) L=46.500X1개소X19EA=883.500 CABLE "10" - (15.24mm - 19EA) L=33.500X1개소X19EA=636.500 CABLE "18" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "3" - (15.24mm - 19EA) L=46.500X1개소X19EA=883.500 CABLE "11" - (15.24mm - 19EA) L=33.500X1개소X19EA=636.500 CABLE "19" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "4" - (15.24mm - 19EA) L=46.500X1개소X19EA=883.500 CABLE "12" - (15.24mm - 19EA) L=33.500X1개소X19EA=636.500 CABLE "20" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "5" - (15.24mm - 19EA) L=37.500X1개소X19EA=712.500 CABLE "21" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "6" - (15.24mm - 19EA) L=37.500X1개소X19EA=712.500 CABLE "22" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "7" - (15.24mm - 19EA) L=37.500X1개소X19EA=712.500 CABLE "23" - (15.24mm - 19EA)
L=49.500X1개소X19EA=940.500 CABLE "8" - (15.24mm - 19EA) L=37.500X1개소X19EA=712.500 CABLE "24" - (15.24mm - 19EA)
L=50.500X1개소X19EA=959.500 CABLE "13" - (15.24mm - 19EA)
L=50.500X1개소X19EA=959.500 CABLE "14" - (15.24mm - 19EA)
L=50.500X1개소X19EA=959.500 CABLE "15" - (15.24mm - 19EA)
L=50.500X1개소X19EA=959.500 CABLE "16" - (15.24mm - 19EA)
L=35.850X1개소X12EA=430.200 CABLE "ET-1" - (15.24mm - 12EA) L=35.915X1개소X12EA=430.980 CABLE "ET-5" - (15.24mm - 12EA)
L=35.850X1개소X12EA=430.200 CABLE "ET-2" - (15.24mm - 12EA) L=35.915X1개소X12EA=430.980 CABLE "ET-6" - (15.24mm - 12EA)
L=47.000X1개소X12EA=564.000 CABLE "ET-3" - (15.24mm - 12EA)
L=47.000X1개소X12EA=564.000 CABLE "ET-4" - (15.24mm - 12EA)
5
P SC Design as per EN1992-2:05
A DVANCED APPLICATIONS
#4
#7 #7
#4 N = 19
6
P SC Design as per EN1992-2:05
Tendon Properties
Material: EN 05(S ) Y1770S7
P.C Strand: Φ15. 2 mm (0.6˝strand)
2
Yield Strength: fpy = 1600 N/mm
2
Ultimate Strength: fpu = 1900 N/mm
2
Cross Sectional area: Ap = 2635.3 mm
Duct Diameter = 103 mm
5 2
Modulus of Elasticity: Eps = 1.95 X 10 N/mm
2
Jacking Stress: fpj = 0.7f pu = 1330 N/mm
Curvat ure friction factor: μ = 0.3 /rad
Wobble friction factor: k = 0.0066 /m
Anchorage Slip: Δs = 6 mm (At the Beginning and at the End)
Load
Dead Load
Self-weight
Input Self-Weight
Superimposed dead load
w = 35.796 kN/m
Pre Stress
Strand (φ15.2 mm×19 (φ0.6˝- 19))
2
Area: A p = 2635. 3 mm
Duct Size: 103 mm
2
Prestressing forc e: 70 % of ultimat e strength. fpj = 0.7fpu = 1330 N/mm
Prestressing losses aft er the initial loss (automatically calculated by
program)
Friction Loss: P( X ) P0 e(kL)
μ = 0.3 /rad, k = 0.006 /m
Anchorage Slip Loss: ΔI c = 6 mm
Elastic Shortening Loss: ΔPE = ΔfP.ASP
7
A DVANCED APPLICATIONS
Live loads
Condition
A. Vehicle Load : Load Model 1 and Load Model 3(600/150)
B. Psi Factor : LM1 Tandem : 0.75
LM1 UDL: 0.4
LM3: 1.15
Di stribution of Lanes
RA 1 Lane 1 Lane 2 RA 2
8
P SC Design as per EN1992-2:05
Support Settlement
Consider each pier undergoing the support settlement of 10 mm under
unfavorable condition.
Temperature Loads
Temperature Range for Procedure A (assuming Moderate climate)
10 degree to 80 degree F
Temperature Gradient (assuming Zone 2)
-Positive temperature value
T1 = 46˚F
T2 = 12˚F
-Negative temperature value
T1 = -0.3 X 46˚F = -13.8˚F
T2 = -0.3 X 12˚F = -3.6˚F
9
A DVANCED APPLICATIONS
Wind Loads
2
Wind Load: 3 kN/m
3 kN/ m2
1.46
10
P SC Design as per EN1992-2:05
11
A DVANCED APPLICATIONS
12
P SC Design as per EN1992-2:05
Reinforcement Input
P 10
#7 #7
P10 N = 19
13
A DVANCED APPLICATIONS
14
P SC Design as per EN1992-2:05
By checking on
“Both end parts (i &
j) have the same
reinforcement”, the
reinforcement data
of one part will be
copied to another.
15
A DVANCED APPLICATIONS
Diagonal Reinforcement
Select to include the diagonal reinforcement in design, and enter the
relevant data.
Pitch: Enter the interval of inclined shear reinforcement
Angle: Enter the angle of inclination for the shear reinforcement
Aw: Enter the total area of inclined shear reinforcing steel
Torsion Reinforcement
16
P SC Design as per EN1992-2:05
17
A DVANCED APPLICATIONS
18
P SC Design as per EN1992-2:05
Load Combination
If “CS Only” is
selected, the
program generates
Result > Combination > Concrete Design>
load combinations Input parameter of the design calculation
after construction
Design Code > EUROCODE 0
stage analysis and
it includes only Manipulation of Construction Stage Load Case> ST+CS
construction stage Condition for Temperature > All Other Effects
load cases.
19
A DVANCED APPLICATIONS
20
P SC Design as per EN1992-2:05
STEP 1
Input Design Parameters
21
A DVANCED APPLICATIONS
a. Recommended
b. British
c. Italy
22
P SC Design as per EN1992-2:05
STEP 2
Classify Load Cases
Long Term
Self-Weight and other Dead Loads
Short Term
Wind, Temperature, Moving Loads etc.
23
A DVANCED APPLICATIONS
STEP 3
Classify Load Combinations
Quasi-permanent
Self-Weight and other Dead Loads
Select some load combinations in this category.
Frequent
Wind, Temperature, Moving Loads etc.
Select some load combinations in this category.
Characteristic
24
P SC Design as per EN1992-2:05
These Load combinations are used in determining the crack width limits.
STEP 4
Modify material properties
25
A DVANCED APPLICATIONS
26
P SC Design as per EN1992-2:05
STEP 5
Select Locations for PSC Design
Using this function we can select the elements and their ends (only I,
only J or both I & J) to be checked for moment or shear or both, for PSC.
If we do not select specific locations for check, both parts (I&J) of all the
elements will be checked for both moment and shear.
27
A DVANCED APPLICATIONS
STEP 6
Select location for output
Using this feature we can select the ends of elements for which flexural
and (or) shear and (or) torsion strength are to be produced in output
report (in excel sheet) generated from ‘PSC Design Calculation’ after
PSC Design. It is important to note that output can be produced only for
those elements which have been assigned PSC Design Option.
In the following example, we will print the flexure, shear and torsion
strength of the elements in the central span and at support.
28
P SC Design as per EN1992-2:05
STEP 7
Exposure Class
This feature enables the user to provide exposure classes specific to
each element and at the Top and Bottom surface of a section. Like other
functions user can edit in tabular format also. By default if not assigned
the Class XC1 is applied at both top and bottom surfaces.
29
A DVANCED APPLICATIONS
STEP 8
Perform the PSC Design
30
P SC Design as per EN1992-2:05
Design Results
It produces PSC design results in excel format for the elements selected
in PSC Print Option.
This sheet can be generated in Post CS stage and if the number of
selected elements is larger, it takes longer time to generate the sheet.
The excel sheet is saved in the saved folder of model files (*.mcb).
31
A DVANCED APPLICATIONS
32
P SC Design as per EN1992-2:05
Table Parameters
33
A DVANCED APPLICATIONS
Calculations
M Rd , Bending resistance
(1) Determine the distance between the temporary neutral axis and the
extreme fiber of concrete that is in compression. When the strain of
Fc x fcd
Fs f s As , f s s Es
Fp f p Ap , f p p E p ,
p p p (0)
(3) C T
Fc ( Fs Fp )
34
P SC Design as per EN1992-2:05
35
A DVANCED APPLICATIONS
Table Parameters
36
P SC Design as per EN1992-2:05
Calculations
Shear resistance VRd ,c
VRd ,c CRd ,c k (1001 f ck )1/ 3 k1 cp bw d
With a minimum of
VRd , c
Ibw
fctd 2 l cp fctd
S
37
A DVANCED APPLICATIONS
Asw,max f ywd 1
cw 1 f cd
2
bw s sin
Where is the Angle of Diagonal reinforcement.
Where the web contains grouted ducts with a diameter bw / 8
the most
Unfavorable level
38
P SC Design as per EN1992-2:05
Table Parameters
maximum torsional moment
Elem Element number TEd among Strength/Stress load
combinations
Design torsional resistance
location of check (I-
Part TRd ,max moment
end, J-end)
Check OK/NG
39
A DVANCED APPLICATIONS
Calculations
tef ,i A / u
40
P SC Design as per EN1992-2:05
Table Parameters
Calculations
Calculate allowable stress
The concrete compressive stress in the structure
c 0.6 fck (t )
For pretension elements, k6 fck (t )
Tensile strength
41
A DVANCED APPLICATIONS
Table Parameters
Tendon Tendon Profile name
FDL1 Stress in tendon at AFDL1 Allowable stress in tendon at
anchorages anchorages
FDL2 Maximum stress in tendon AFDL2 Allowable stress in tendon
along the length of the along the length of the
member away from the member away from the
anchorages immediately anchorages immediately after
after anchor set anchor set
FLL maximum stress in tendon AFLL allowable stress aft er all
after all lossess at the last losses at the last stage
stage
Calculations
p = k5 f pk
42
P SC Design as per EN1992-2:05
Table Parameters
Calculations
Calculate allowable stress
Allowable compressive stress
c k1 f ck
Note: k1 from National Annex. The recommended value is 0.6
Allowable tensile stress
ct f ctm
43
A DVANCED APPLICATIONS
Table Parameters
Elem Element number Sig_P5 principal stress at the top of left
web
Part Check location (I-end, J- Sig_P6 principal stress at the top of
end) right web
Comp/T Compression, tension Sig_P7 principal stress at the center of
ens left web
Stage construction stage Sig_P8 principal stress at the center of
right web
CHK principal stress check at a Sig_P9 principal stress at the bottom of
construction stage left web
Sig_P1 principal stress at the left Sig_P10 principal stress at the bottom of
top of top flange right web
Sig_P2 principal stress at the right Sig_MA X the maximum principal stress
top of top flange among P1~P10
Sig_P3 principal stress at the right Sig_AP allowable principal stress
bottom of bottom flange
Sig_P4 principal stress at the left
bottom of bottom flange
44
P SC Design as per EN1992-2:05
Table Parameters
45
A DVANCED APPLICATIONS
Table Parameters
46
P SC Design as per EN1992-2:05
Calculations
wk sr ,max ( sm cm )
f ct ,eff
s kt (1 e p ,eff )
p ,eff s
sm cm 0.6
Es Es
sr ,max 1.3(h x)
Check crack
wk wmax
wmax = Table 7.101N-Recommended value of wmax and relevant
combination rules
47
A DVANCED APPLICATIONS
Table Parameters
Elem Element number Fy Design Shear force at the element
end along y axis
Part Check location (I-End, J-End) of Fz Design Shear force at the element
each element end along z axis
LCom Load Combination Mx Design torsional moment at the
Name corresponding to maximum and element end
minimum value
Ty pe Member force due to moving My Design moment at the element end
load, which causes the due to bending about y axis.
maximum stress.
Fx Design axial force at the Mz Design moment at the element end
element end due to bending about z axis.
48
P SC Design as per EN1992-2:05
49
A DVANCED APPLICATIONS
50
P SC Design as per EN1992-2:05
Excel Report
MS Excel format report is generated for the engineer ’s
verification.
51