You are on page 1of 7

Task # 5

Install three bulbs controlled by two 3 SPST switch with two


convenience outlet.

Please refer to the Learning Outcome No. 2. Layout and Install PVC
raceway/molding for the important PEC provisions in installing rigid non-
metallic conduit and personal safety

TOOLS, EQUIPMENT AND MATERIALS

Equipment:
 Heat gun 1 unit
Materials:
 Pencil or Chalk 1 pc
 PVC pipe 3 pcs
 PVC adapter with lock nuts 18 pcs
 Utility box 5 pcs
 Junction box 4 pcs
 Lamp socket 3 pcs
 Safety switch 1 pc

 SPST switch 3 pc
 1 gang plate cover 3 pcs
 2 gang plate cover 2 pcs
 Conduit clamps/straps 15 pcs
 Wood screws (1/4 x ½) 50 pcs
Tools:
 Steel meter stick/Straight edge 1 pc
 Try square 1 pc
 Pull and push rule 1 pc
 Wet rug 1 pc
Personal Protective Equipment:
 Gloves 1 pair
 Respirator 1 pc

1|Page
Procedure:

Instruction: When you are ready to perform this task, ask your teacher to
observe the process and to rate your performance using the
assessment criteria.

1. Prepare the necessary tools, materials and equipments.

2. Wear the appropriate Personal Protective Equipment (PPE).

2|Page
3. Mark on the wiring board the location of the safety switch, utility
boxes, and junction boxes.

4. Fasten the safety switch and Polyvinyl Conduit (PVC) boxes with wood
screws at the desired locations.

5. Prepare the Polyvinyl Conduit (PVC) conduit for installation.

a. Measure and cut each PVC pipe according to the desired length
b. Make an offset bend at each end of PVC conduit which will be
connected to a box.
c. Bend 90º based on the diagram.

6. Install and connect ends of PVC pipe to the electrical boxes, safety
switch.

7. Support the conduit with conduit clamps or straps.

8. Fish-in conductors/wires inside conduits/wire ways based on the


required size of wire as prescribe by the Philippine Electrical Code
(PEC).

9. Cut wire according to the desired length. Always provide allowance (6-
8” for smaller size of wire) for future tapping or termination.

3|Page
10. Strip wires in the boxes then connect them to the terminals of the
switches and fuse clip holder. Note: All loop termination must be
turning clockwise and be tightened snugly according to the
manufacturer’s torque specifications. Avoid excess wire termination.

11. Splice and joint wires in junction boxes based on the circuit design
operation. Joining or splicing of conductors inside conduits
raceways is strictly prohibited. Make sure that the joined wires have
6-8” allowances from the edge of the box to the outstripped joined
end of wires.

12. Mount/Connect LED lamp based on the circuit design operation.


(Line diagram)

13. Check the continuity of circuit to identify and troubleshoot possible


defects.

III Diagram:

1. Schematic Diagram

4|Page
2. Line Diagram

3. Wiring Diagram

5|Page
Guide Question:
1. What is the importance of having accurate measure and correct
connection from that task given:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
_______________________________________________________________________

2. What is the use of different diagrams in assembling the circuit?


________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
3. Cite some difficulties in assembling the circuit:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
_

VI Conclusion:
___________________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________

IV Assessment Criteria

Dimensions
5 3 1

1. Quality: Workmanship, Appearance,


Offset Bending, Bending 90º
2. Accuracy: Dimension, Accurate bending
3. Method: Observance of the safety
measures.
4. Speed: Submission on time +1; before the
expected
time +2; and after the expected time – 2.

6|Page
Criteria Student Teacher
Quality:,
Accuracy:
Method:.
Speed:

total

7|Page