Professional Documents
Culture Documents
JOB SHEET
Install two bulbs controlled by two (2) three-way switches and one
(1) SPST switch with two convenience outlet.
Please refer to the Learning Outcome No. 2. Layout and Install PVC
raceway/molding for the important PEC provisions in installing rigid non-
metallic conduit and personal safety
Equipment:
Heat gun 1 Unit
Analog Multi Tester 1 Unit
Materials:
Pencil or Chalk 1 pc
PVC pipe 3 pcs
PVC adapter with lock nuts 18 pcs
Utility box 3 pcs
Junction box 3 Pcs
LED Lamp 15W 2 pcs
Lamp socket 2 pcs
3 way switch 2 pcs
SPST switch 1 pcs
1 gang plate cover 2 Pcs
Conduit clamps/straps 15 pcs
Wood screws (1/4 x ½) 50 Pcs
Circuit Breaker 15A 1 Pc
Circuit Breaker 20A 1 Pc
Electrical Tape 1 roll
1|P a ge
Tools:
Steel meter stick/Straight edge 1 pc
Try square 1 pc
Pull and push rule 1 pc
Wet rug 1 pc
Hack Saw 1 pc
Procedure:
Instruction: When you are ready to perform this task, ask your teacher to
observe the process and to rate your performance using the
assessment criteria.
3. Mark on the wiring board the location of the safety switch, utility
boxes, and junction boxes.
4. Fasten the safety switch and Polyvinyl Conduit (PVC) boxes with wood
screws at the desired locations.
a. Measure and cut each PVC pipe according to the desired length
b. Make an offset bend at each end of PVC conduit which will be
connected to a box.
c. Bend 90º based on the diagram.
6. Install and connect ends of PVC pipe to the electrical boxes, safety
switch.
2|P a ge
8. Fish-in conductors/wires inside conduits/wire ways based on the
required size of wire as prescribe by the Philippine Electrical Code
(PEC).
9. Cut wire according to the desired length. Always provide allowance (6-
8” for smaller size of wire) for future tapping or termination.
10. Strip wires in the boxes then connect them to the terminals of the
switches and fuse clip holder. Note: All loop termination must be
turning clockwise and be tightened snugly according to the
manufacturer’s torque specifications. Avoid excess wire termination.
11. Splice and joint wires in junction boxes based on the circuit design
operation. Joining or splicing of conductors inside conduits raceways
is strictly prohibited. Make sure that the joined wires have 6-8”
allowances from the edge of the box to the outstripped joined end of
wires.
3|Pa ge
14. Place the cover of junction box, utility box, and convenience
outlet.
Line diagram of the two bulbs controlled by two (2) three-way switches
and one (1) SPST switch with one convenience outlet.
√
30cm
25cm
4|Pa ge
III Diagram:
1. Schematic Diagram
2. Line Diagram
5|P a ge
3. Wiring Diagram
Guide Question:
1. What is the importance of having accurate measure and correct
connection from that task given:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
_______________________________________________________________________
___________________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
IV Assessment Criteria
Dimensions
5 3 1
total
7|P a ge