You are on page 1of 1

Thickness?

Please refer to Comments on the Sample


Grout Color?

The Thickness should be X


Matching with the Approved 05/07/20

Sample.
This Screw is to
Install the Trim?

? N

? Q

? PERSIAN
RESTAURANT

Please Specify
Filler Material / Thickness
1 DETAIL ( TYPICAL THRESHOLD) @ MAIN DINING 2 DETAIL @ MAIN ENTRANCE 3 DETAIL ( FLOOR TRIM) @ MAIN DINING/FOH KITCHEN 4 DETAIL ( FLOOR TRIM) @ TERRACE AREA
SCALE 1:2 (REF # GEN-20002) SCALE 1:2 (REF # GEN-20002) SCALE 1:2 (REF # GEN-20002) SCALE 1:2 (REF # GEN-20002) GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED.

Wrong Waterproofing termination Detail


MENTIONED SIZE DRAWING SET IS FULL SIZE.

Contractor to Provide Proper Detail. REFERENCE NUMBER DATE


MEP COORDINATION
TITLE

DEC ARCHITECUTRAL COMMENTS


1. FINAL DIMENSIONS TO BE AS PER SITE CONDITIONS.
2. COORDINATE WITH ALL RELATED OTHER PACKAGE FOR
EXTERNAL WORKS , STRUCTURE, PARTITIONS & ETC.
3. CONTRACTOR TO ENSURE THAT THE DOCUMENTS LISTED
BELOW BUT NOT LIMITED TO ARE REFERENCE DESIGN DRAWINGS
FOLLOWED IN ITS ENTIRETY DURING SITE EXECUTION. IFC REFERENCE NUMBER DATE TITLE
DRAWINGS, INSTURCTIONS, DESIGNERS/
CLIENTS SIGNED OFF DRAWINGS,SDIRS,RFI RESPONSES &
ETC.
4. DEVIATING FROM THE VARIOUS APPROVED DURING
EXECUTION OF WORKS WILL RESULT IN
REFERENCE SHOP DRAWINGS
REJECTION OF WIR REFERENCE NUMBER DATE TITLE
5. ALL MARBLE WORKS SUBJECT TO DRY LAY APPROVAL
6. ALL MATERIALS TO BE AS PER APPROVED
SAMPLES/MOCKUPS.
7. ALL ROUGH CARPENTRY TO BE AS PER SPECIFICATIONS.
8. CONTRACTOR TO COORDINATE DOOR STRUCTURAL
OPENING WIDTH & HEIGHT WITH ID,
ARCHITECTURE, DOOR SCHEDULE AND SITE CONDITION.
RELATED DOCUMENTS
REFERENCE NUMBER DATE TITLE

5 BLOW-UP DETAIL @ TERRACE AREA 6 DETAIL @ TOILET CORRIDOR


SCALE 1:2 SCALE 1:2 (REF # GEN-20002)

11 DETAIL @ WET AREAS ( TOILET NICHE )


SCALE 1:2 (REF # GEN-20002)

Min 1 % Slope for Outdoor

T4

17

16

15

14

13

To Provide Proper Detail ,


-Water Proofing Detail is Wrong.
-To Specify all the Materials, Channel, Cover,
Sealant Color & Etc.
-To Indicate all Detail Dimensions.
6
8 BLOW-UP DETAIL @ TERRACE AREA
10.1 DETAIL @ TERRACE AREA -To Ensure Size of the Channel & Cover is matching
SCALE 1:2 (REF # GEN-20002) 2
SCALE 1:2 (REF # GEN-20002)
with the Slope.
-To Indicate How the Channel is Installed on the Floor.
7 DETAIL @ TOILET AREA
SCALE 1:2 (REF # GEN-20002)
SUBJECT TO GROUT 7 *This Detail is not part of this Review.
SAMPLE REVIEW.

7
REV DATE DESCRIPTION DRN CHK APP
9

M11 6
THE ROYAL ATLANTIS RESORT
AND RESIDENCES
Palm Jumeirah Crescent, Dubai U.A.E.

IBI GROUP ARCHITECTS


95 St. Clair Ave. West, Suite 200
Toronto, ON, M4V1N6, Canada
tel (416) 924-9966 fax (416) 924-9067
ibigroup.com

?
1 1 3 1 OFFICE 2805 - 2810,CONCORD TOWER,
MEDIA CITY, DUBAI, UNITED ARAB EMIRATES,
P.O. BOX: 79593
TEL.: 04-2989220, FAX: 04-2989210
www.decengineering.net

Abu Dhabi UAE Office Dubai UAE office


P.O. BOX 73814 P.O. BOX 334138
Tel.: +971 2 499 5 444 Tel.: +971 4 346 7 711
Fax: +971 2 499 5 400 Fax: +971 4 346 7 722
M11 email: decov@decovision.ae email: decov@decovision.ae
5 8 5
5 8 8 5
PACKAGE F5C
PERSIAN RESTAURANT
TYPICAL FLOOR AND WALL DETAILS
10 10
LIVING GREEN WALL

WALL
PJCRC 19-27C / PALM JUMEIRAH

LIVING GREEN
Contractor to ensure Waterproofing Detail
Is coordinated with Facade. Also to make sure 19.09.2019 NC BA A1 AS DRAWN

No Penetration need to be done on the Water Proofing 10.1 10.1


TRA DCV SDG ID
10 DETAIL @ TERRACE AREA
9 DETAIL @ FEMALE TOILET and all the Termination details SCALE 1:2 (REF # GEN-20002)
12 KEY PLAN
SCALE 1:2 (REF # GEN-20002) will not Affect performance of the Waterproofing SCALE 1:100 GEN 20009 02

You might also like