You are on page 1of 8

SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.

00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Fence and Gate Components Receiving Inspection- Types I -


SAIC-M-1001 15-Nov-17 CIVIL-
V Fences
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A General Fence Components Receiving Inspection

Saudi Aramco Security Fencing Type I shall be used for all facilities where SAES-M-006
A1
security is of concern. Sec. 4.3

Use of Reclaimed material is not permitted unless written approval is SAES-M-006


A2
obtained from the Proponent Organization. Sec. 4.2

Saudi Aramco Security Fencing Type I, II, III, IV and V, General Purpose
Fencing shall be made of Zinc-coated galvanized material or Vinyl-Clad
galvanized materails and shall be as follows:
a. Zinc-coated (galvanized) steel wire fencing SAES-M-006
A3
b. Zinc-coated (galvanized) fence posts, rails, gates, fitting, barbed wire, Sec. 4.5
tension wire, and tie wire.
c. Vinyl–clad( polyviyle chloride-covered) galvanized steel wire fencing
d. Vinyl-clad galvinzed barbed wire, tension wire, and tie wire.

Galvanized fabric and hardware shall be used for all inland locations SAES-M-006
A4
(more than 1.5 km from the sea). Sec. 4.6

Vinyl-clad fabric, barbed wire, tension wire, tie wire and gate infilling shall SAES-M-006
A5
be used on all locations within 1.5 km from the sea. Sec. 4.6

Types of Saudi Aramco fencing and their appurtenances:


Fence Height Top Brace Post Barbed Wire Number Continuous
Type Fabric Rail For Each Number of of Barbed Concrete
(mm) Line Post Arms Wires Anchor SAES-M-006
A6 I 2.4m Yes Yes 2 6 Yes Sec. 4.11
II 2.4m Yes Yes 2 6 No Table 2
III 2.4m No No 2 6 No
IV 2.4m No No 1 3 No
V 2.4m No No 0 0 No

The fencing materials are inspected and verified by the Buyer's Inspection
SAES-M-006
A7 Representative per Saudi Aramco Inspection Requirements Form 175-
Sec. 6.2
120700.

B Gates and Components Receiving Inspection

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Fence and Gate Components Receiving Inspection- Types I -


SAIC-M-1001 15-Nov-17 CIVIL-
V Fences
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Applicable Gate Sizes:


Fence Gate Walk/ Width Overall Gate Frame Gate Post
Type Type Drive opening Height Extensions O.D.(mm)
SAES-M-006
I,II,III,IV,V A Walk 1.2m 2.45m No 73
B1 Sec. 4.12
B Drive 4.0m 2.8m Yes 102
Table 3
I,II,III,IV C Drive 7.3m 2.8m Yes 102
V D Drive 4.0m 2.45m No 102
E Drive 7.3m 2.45m No 102

Gates shall be framed with 48mm O.D. steel pipe, Schedule 40, ASTM SAES-M-006
B2
A53 as the framing material. Sec. 5.12.a.

SAES-M-006 Sec.
B3 Gates shall have welded or bolted construction.
5.12.b

SAES-M-006 Sec.
B4 Gates shall have 10 mm diameter adjustable diagonal tension rods.
5.12.c

Gates shall have 50mm mesh chain link, 3.75mm diameter link vinyl-clad SAES-M-006 Sec.
B5
galvanized as specified on the Purchase Order and/or Drawings. 5.12.d

SAES-M-006 Sec.
B6 Gate hinges are able to swing 900 either way from a closed position.
5.12.e

SAES-M-006 Sec.
B7 Gates shall have fittings for 35mm diameter plunger rod.
5.12.f

Gates shall be equipped with attachments for padlocking, the padlock to SAES-M-006 Sec.
B8
be accessible from both sides of the gate. 5.12.g

Gates shall be equipped with 35mm diameter plunger rod for each gate SAES-M-006 Sec.
B9
leaf; as an alternative to only a single plunger rod. 5.12.h

Gate leaves shall be equipped with a plunger rod receiver and open-gate SAES-M-006 Sec.
B10
holders. 5.12.i

Where required, gate frame extensions shall extend 300mm above the SAES-M-006 Sec.
B11
gate frame. 5.12.j

Where gates exceed 1200mm in width, additional vertical framing


SAES-M-006 Sec.
B12 members shall connect the top and bottom horizontal members dividing
5.12.k
the leaves into panels between 900mm and 1550mm in width.

C Fence Post Receiving Inspection

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Fence and Gate Components Receiving Inspection- Types I -


SAIC-M-1001 15-Nov-17 CIVIL-
V Fences
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Post Lengths: Length of Posts (mm)


Fence Type: I II III IV V
Walk Gate 3400 3400 3400 3400 3400
SAES-M-006
Drive Gate 3900 3900 3900 3900 3400
Sec. 4.13
C1 Line 3400 3400 3400 3400 3400
Table 4
Corner/End 3400 3400 3400 3400 3400
Brace 2900 2900 2900 2900 2900
Post Lengths (Heights) are subject to a +/- 12mm tolerance; They include
975 mm for embedment in the footings.

All tubular steel posts shall be as specified in the purchase order or on the
IFC Drawings, shall be schedule 40 and galvanized in accordance with
ASTM A53.
Table 1 - Post Diameters SAES-M-006
Classification Nominal Post Size (inches) O.D. mm Sec. 4.8
C2
Brace and Rails 1.25" 41 Table 1
Line Posts 2.0" 60
Corner/End Posts 2.5" 73
Single Gates 1.2m wide 2.5" 74
Double Gates 4.0-7.3m wide 3.5" 102

SAES-M-006
All Posts shall be equipped with moisture excluding top caps or extension Sec. 5.2.8
C3
arms.
SAES-M-006
All Posts shall be supplied with the necessary holes drilled for the Sec. 5.2.9
C4
appropriate fittings.

D Fencing Fabric and Fittings Receiving Inspection

Table 5 - Wire Types:


SAES-M-006
Coating Type Size O.D. Min. Breaking Strength Sec. 5.5.1
D1
Plain Galvanized 3.75mm 5740 N(1290lbs) Table 5
PVC Fusion Bonded 3.75mm 5340 N(1200lbs)
Extruded Vinyl 4.88mm 5340 N(1200lbs)

Fabric shall be chain link with a 50 mm diamond mesh and a height of


SAES-M-006
2400 mm (±12 mm). Fabric shall have the top and bottom selvages
Sec. 5.5.1
D2 machine twisted with the wire cut on a bias to form a barbed finish. The
standard length of roll shall be 15m and shall be woven continuously
without splices.

SAES-M-006
Hot dip galvanizing shall be in accordance with ASTM A123 and ASTM Sec. 5.5.2
D2
A153.
SAES-M-006
Sec. 5.5.3
D4 Fence welding shall be according to AWS D1.1.

Galvanizing (hot dipping) shall be either after weaving, according to ASTM SAES-M-006
D5 A392, Class I, or before weaving according to ASTM A392, Class II. Roll Sec. 5.5.4
dipping is not acceptable.

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Fence and Gate Components Receiving Inspection- Types I -


SAIC-M-1001 15-Nov-17 CIVIL-
V Fences
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Vinyl-coated chain link fabric shall be either PVC fusion bonded (per SAES-M-006
D6 ASTM F668, Class 2b) or extruded type (per ASTM F668, Class I); both Sec. 5.5.5
are equally acceptable.

The Zinc-coated tension wire shall be galvanized per ASTM A641, Class
SAES-M-006
III with a coating of not less than 244 g/m² (0.80 oz/ft²) of surface area.
D7 Sec. 5.7.1
Wire shall be a minimum of 4.5 mm nominal diameter and possess a
minimum breaking strength of 6230 N (1400 lb).

The Vinyl-clad tension wire shall be vinyl-coated and have the same type
of coating (PVC Fusion-bonded or Extruded) as specified for the fence SAES-M-006
D8 fabric. The core wire shall be a minimum of 3.55 mm nominal diameter Sec. 5.7.2
and possess a minimum breaking strength of 5740 N (1290 lb). The core
wire shall be galvanized in accordance with ASTM A641, Class I.

Tie wire shall be galvanized per ASTM A641 with a coating of not less
SAES-M-006
than 244 g/m² (0.80 oz/ft²) of surface area and shall match the fence
D9 Sec. 5.8.1
fabric. Tie wire shall be 3.0 mm nominal diameter minimum and 250 mm ±
10 mm long.

The vinyl-coated tie wire have the same type of coating (PVC fusion-
SAES-M-006
bonded or extruded) as specified for the fence fabric. The core wire shall
D10 Sec. 5.8.2
be 2.65 mm nominal diameter minimum and 250 mm ± 10 mm long and
shall be galvanized in accordance with ASTM A641, Class I.

Except for Type V Fencing, barbed wire shall be secured to the extension
SAES-M-006
arm by lock wire. Lock wire shall be ASTM A641, 360 mm long by 3.75
D11 Sec. 5.6.2 & 5.6.3
mm nominal diameter wire, minimum, annealed and galvanized with a 25
mm diameter hook on one end.

Three or six rows of barbed wire shall be furnished as required by the


particular fence type. Each row consist of two twisted stands of not lighter
than 2.5 mm nominal diameter wire, with four barbs (points) of not lighter
SAES-M-006
than 2 mm nominal diameter wire, spaced 125 mm ± 20 mm apart. The
D12 Sec. 5.6.1
barbs shall be wrapped so as to interlock with both main strands of wire.
The galvanized barbed wire shall conform to ASTM A121 - 99. The Vinyl-
Clad barbed wire shall be uniformly galvanized in accordance with ASTM
A641, Class I for the fence.

SAES-M-006
All fittings shall be galvanized pressed steel or wrought iron or malleable
D13 Sec. 5.11.1
iron and in accordance with ASTM F626.

Attachment of fittings shall be with galvanized carriage bolts with nuts, SAES-M-006
D14 except for post extension arms where galvanized machine bolts shall be Sec. 5.11.2
used. All bolts and nuts shall be galvanized.

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Fence and Gate Components Receiving Inspection- Types I -


SAIC-M-1001 15-Nov-17 CIVIL-
V Fences
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

SAES-M-006
D15 All gate fittings shall be compatible with the gates supplied.
Sec. 5.11.3

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-M-006 -- Saudi Aramco Security and General Purpose Fencing, 01 November 2015
2- SASD-AA-036678 Rev. 1 -- Saudi Aramco Security and General Purpose Fencing Post and Fabric Details, 01 May 1990
3- SASD-AB-036677 Rev. 2 -- Saudi Aramco Security and General Purpose Fencing, An Overview (Architectural), 01 April 1990
4- SASD-AB-036679 Rev. 1 -- Saudi Aramco Security and General Purpose Fencing Gate Details, 01 May 1990
5- SASD-AC-036680 Rev. 3 -- Saudi Aramco Security and General Purpose Fencing Footing Details, 01 April 1997
6- SASD-AE-036881 Rev. 4-- List of Material for Saudi Aramco Security Fencing, 01 November 1993
7- SASD-AE-036882 Rev. 4 -- List of Material for Saudi Aramco Type II Fencing, 01 November 1993
8- SASD-AE-036883 Rev. 4 -- List of Material for Saudi Aramco Type III Fencing, 01 November 1993
9- SASD-AE-036884 Rev. 4 -- List of Material for Saudi Aramco Type IV Fencing, 01 November 1993
10- SASD-AE-036904 Rev. 3-- List of Material for Saudi Aramco Type V Fencing, 01 December 1993

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016)

Saudi Aramco: Company General Use


Rev. 2016.06.00

###

Saudi Aramco: Company General Use


30-Jun-16

Saudi Aramco: Company General Use