ADDMIX 109 PCCI is a bipolar concrete penetrating corrosion inhibiting admixture (CPCIA) to protect embedded steel
reinforcement in concrete from corrosion.

Specification:
Reinforced concrete has been widely used in the last century, however due to aggressive agents such as carbonic gas and
chloride ions, it suffers premature deterioration. The concrete is a physical barrier that protects steel from corrosion, and the
alkalinity of concrete leads to the formation of a passive layer around the reinforcement, which increases protection against
corrosive processes. However, concrete is a porous material and has cracks that allow the entrance of aggressive agents,
destabilizing the passive layer and corroding the steel. Corrosion is the major cause of deterioration of concrete structures
and several methods like ADDMIX 109 PCCI of protection and repair have been developed to increase the durability of such
structures and ADDMIX 109 PCCI is preferred solution. Corrosion inhibitors, chemical substances that reduce the corrosion
rate, have been widely used, both for prevention and correction. It is very important to know the different types of inhibitors for
correct use, thus increasing the life span of reinforced concrete structures. The most effective and nontoxic corrosion inhibitor
ADDMIX 109 PCCI provides unique protection by the virtue of diffusion through the concrete. This product conforms to RDSO
specification: M&C/PCN/126/2020, and EIL norms.

Uses:
 Underground structures
 Metros
 Bridges
 Jetties
 Industrial ETP & STP water retaining structures
 Cooling Towers
 Power Plants
 Buildings.

Mechanism:
High Potency molecules of ADDMIX 109 PCCI (liquid) by virtue of its ability to diffuse within the concrete surround the rebar
at periphery of the concrete. This provides first line of defense against chloride ions at the point of entry. Upon deposition on
reinforcement and saturating the immediate concrete, ADDMIX 109 PCCI protects the structure against corrosion.

Dosage:
1 Kg of ADDMIX 109 PCCI per cubic meter of concrete.

Typical Properties:

Sr. No. Properties Specification Method of Tests


Appearance Brownish Liquid free from any Visually
1 visible residual deposits
Viscosity of the material as in 10-20 sec. IS:101(Pt.1/Sec.5)1989
supplied condition, by Ford cup No
2
4, at 27 ± 2ºC

3 Specific Gravity at 27 ± 2ºC 1.04-1.06 IS 1448-1967

pH: pH meter/Standard pH paper


i) As in supplied condition i) 9.0-11.0
4
ii) 1% dilution ,w/w ii) 9.0-11.0

SP CONCARE PVT. LTD.


CS No. 1471, DB House 1st Floor,
Madhavnagar Road, Near Auto India,
info@spconcare.com www.spconcare.com Sangli-416416, Maharashtra, (INDIA)
Last update on: 09-03-2023
Version: 2
Effect of CPCIA* on corrosion of Rate of corrosion shall be; Long term corrosion test [ASTM
embedded steel rebars exposed to G-109-2005]
chloride environments after 09 Dosage: 1Kg per Meter Cube of
cycles (14 days wetting and 14 Concrete
5
days drying) as per ASTM G109.
i) With out CPCIA - * i) 25.00 Coulombs, max
ii) With CPCIA- Addmix 109 PCCI ii) 0.50 Coulombs, max.

Chloride Migration profile With out With AASHTO T-259


properties of concrete with & CPCIA* CPCIA*
without CPCIA (Addmix 109 PCCI)
i) Chloride % in concrete at 30 mm Chloride % shall be i) Chloride ion penetration
depth after 90 days. (For all types (Salt ponding test) [IS:456-
of cements e.g. OPC, PPC, PSC, 0.025% max Nil 2000]
SRC)
Dosage: 1Kg per Meter Cube of
Concrete
ii) Ability to resist chloride ion Resistance to chloride ion ii) Electrical indication of
6
penetration (RCPT) (For all types penetration shall be Concrete ability to resist
of cements e.g. OPC, PPC, PSC, Chloride Ion Penetration
SRC) (Rapid Chloride Permeability
a) Concrete grade M-30, Water 1650 1000 test) [ASTM C-1202 1997]
cement ratio: 0.45 Coulombs Coulombs
max max Dosage: 1Kg per Meter Cube of
Concrete
b) Concrete grade M-40, Water 1550 1000
cement ratio: 0.40 Coulombs Coulombs
max max

Test for Physical Property of Cement:


Compressive Strength Cement Mortar Without Inhi Corrosion inhibitor Mixed Inhibitor mixed with water
(MPa)(On Mortar Cubes Inhibitor (MPa) with Cement &then cement first and then with cement
as per BIS mortar (MPa) and sand to make mortar
Standards) (MPa)
3 Days 15.87 16.43 16.48
7 Days 18.58 20.14 20.37
Observation: It is important to note that by addition of ADDMIX 109 PCCI inhibitor, the Compressive Strength of
Mortar slightly increases when compared to the control mortar i.e. without inhibitor system.

Storage and Shelf life All:


Store under cover, out of direct sunlight and protect from extremes of temperature. In tropical climates the product must be
storedin an air-conditioned environment. Shelf life is 12 months when stored as above.

Safety precautions:
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin, and
foodstuffs (which can also be tainted with vapor until product is fully cured or dried). Treat splashes to eyes and skin
immediately. If accidentallyingested, seek immediate medical attention. Keep away from children and animals.

Disclaimer:
Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is
given or implied with any recommendations made by us, our representatives, or distributors, as the conditions of use and the
competence of any labor involved in the application are beyond our control.

SP CONCARE PVT. LTD.


CS No. 1471, DB House 1st Floor,
Madhavnagar Road, Near Auto India,
info@spconcare.com www.spconcare.com Sangli-416416, Maharashtra, (INDIA)

You might also like