You are on page 1of 223

CLIENT NAME TBC

xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK

SITE PREPARATION

Site preparation

A Site clearance 1,366 m2 0.00

EARTH WORKS

Excavation

Excavation all in accordance with drawings

B Over site excavation to remove top soil, 150 mm depth 1,366 m3 0.00

C Basement excavation 3,785 m3 0.00

D Trench Excavation receive foundation 19 m3 0.00

E Pit Excavation 83 m3 0.00

F Allow for necessary earthwork support system 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Disposal

Disposal of excavated material arising from excavation

A Remove surplus unsuitable excavated materials off-site 3,600 m3 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Filling

Backfilling

Compaction of formed ground to 98% max dry density as


A 935 m2 0.00
Drawings

Backfilling with selected imported excavated materials; in


B compliance with the Project requirements and Engineers 287 m3 0.00
approval.

200 mm thick Road base material below raft foundation


C compacted to not less that 98% of soils maximum dry 187 m3 0.00
density

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Soil Treatment

Allow for termite control; prepare and apply anti-termite


treatment; all in accordance drawings and subject to the
Engineer's approval

A To horizontal surfaces 949 m2 0.00

B To vertical surfaces 555 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Dewatering

Allow for dewatering as required

Provide suitable system for dewatering and keeping the


surface free from ground or surface water and maintain up
A to completion of structures and placement of structural 1 item 0.00
backfill up to finished ground level and prior approval is
obtained from the Engineer

Maintain suitable system for dewatering and keeping the


surface free from ground or surface water and maintain up
B to completion of structures and placement of structural day
backfill up to finished ground level and prior approval is
obtained from the Engineer (rate only)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Sundries

Allow for the construction of services access to the villa


including the structure, finishes, external finishing
A 1 item 0.00
enhancements, doors and MEP provisions all to the
approval
Allow for the construction of garbage room to the villa
including the structure, finishes, external finishing
B 1 item 0.00
enhancements, doors and MEP provisions all to the
approval

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION B - SITE WORK (CONT'D)

EARTH WORKS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION B -Page: 1 0.00

BILL 02/SECTION B -Page: 2 0.00

BILL 02/SECTION B -Page: 3 0.00

BILL 02/SECTION B -Page: 4 0.00

BILL 02/SECTION B -Page: 5 0.00

BILL 02/SECTION B -Page: 6 0.00

BILL 02/SECTION B -Page: 7 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION B -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK

PREAMBLE

Notwithstanding Clauses C3.1 to C3.4 inclusive of the


Principles of Measurement (International) for Works of
Construction (June 1979 Edition) reinforcement has been
measured from kg per m³ of concrete ratios provided by the
Engineer. However, the Contractor shall have satisfied Note
himself as to the adequacy of the reinforcement quantities
stated below and is deemed to have made due allowance
within his rates for all reinforcement necessary to complete
the Works.

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE

(1) This bill includes all structural work below the ground
Note
floor structural slab

(2) This work has been measured assuming an average


Note
existing ground level of 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE (CONT'D)

Poured Concrete

Plain poured concrete; Grade 20 Mpa; all in accordance with


Drawings

A Blinding; 75 mm thick 3 m3 0.00

B Blinding; 100 mm thick 94 m3 0.00

C Ditto; 50 mm thick, protective blinding layer 47 m3 0.00

Reinforced poured concrete; Grade 40 Mpa; all in


accordance with Drawings

D Raft foundations; 500 mm thick 451 m3 0.00

E Raft foundations; 600 mm thick 1 m3 0.00

F Raft foundations; 700 mm thick 3 m3 0.00

G Raft foundations; 900 mm thick 7 m3 0.00

H Lift Pit base;900 mm thick 50 m3 0.00

J Footing;500 mm thick 6 m3 0.00

K Suspended slabs; 200 mm thick, to landings 1 m3 0.00

L Suspended slabs; 300 mm thick, ramp slab 37 m3 0.00

M Slabs on grade; 100 mm thick 8 m3 0.00

N Grade beams 8 m3 0.00

P Retaining walls; 300 mm thick 126 m3 0.00

Q Upstands 1 m3 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE (CONT'D)

Poured Concrete (Cont'd)

Reinforced poured concrete; Grade 40 Mpa; all in


accordance with Drawings (Cont'd)

A Shear walls; 300 mm thick 27 m3 0.00

B Core walls; 200 mm thick 5 m3 0.00

C Core walls; 250 mm thick 2 m3 0.00

D Columns 24 m3 0.00

E Staircases 2 m3 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE (CONT'D)

Reinforcement

Reinforcement; deformed bars to BS Standards; Grade 460


N/SQMM; all in accordance with the Drawings

A To raft foundations 45,769.00 kg 0.00

B To pad footing 540.00 kg 0.00

C To suspended slabs 8,012.00 kg 0.00

D To grade beams 1,136.00 kg 0.00

E To retaining walls 32,708.00 kg 0.00

F To shear walls 6,993.00 kg 0.00

G To core walls 1,857.00 kg 0.00

H To upstands 13.00 kg 0.00

J To columns 14,764.00 kg 0.00

K To staircases 268.00 kg 0.00

Wire mesh reinforcement; 1 layer of A-252 BRC mesh


reinforcement; all in accordance with the Drawings

L To slabs on grade 77 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE (CONT'D)

Shuttering

Formwork; basic finish; all in accordance with the Drawings

A To sides of raft foundations 67 m2 0.00

B To sides of footings 12 m2 0.00

C To sides of slabs on grade 65 m 0.00

D To sides of grade beams 49 m2 0.00

E To sides of lift pits 10 m2 0.00

F To sides of retaining walls 839 m2 0.00

G To sides of shear walls 192 m2 0.00

H To sides of core walls 64 m2 0.00

J To sides of upstands 9 m 0.00

K To sides of columns 199 m2 0.00

L To soffits of stair landings 4 m2 0.00

M To soffits of ramp slab 123 m2 0.00

N To sloping soffits of staircases 6 m2 0.00

P To sides, treads and risers of staircases 3 m2 0.00

Q To sides of sump and drain pits 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUBSTRUCTURE (CONT'D)

Sundries

Solid block work below tie beam as section A of Drawing S-


02-004

A 300 mm thick; Below tie beams 27 m2 0.00

Isolation joints with polyvinyl sealant, flexcel board and all


necessary accessories complete as section detailed on
Drawing S-02-004

B Isolation joints 48 m 0.00

Expansion joints with Mastic filling, PVC pipe filled with non-
bonding agent, 600mm long 12mm dia. rod as detailed on
Drawing S-00-005

C 18 mm thick expansion joint with flexcel board 1 item 0.00

Allow for forming Earth pits, sump pits, drain pits etc as
service drawings

D General allowance 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUPERSTRUCTURE

Poured Concrete

Plain poured concrete; Grade 40 Mpa; all in accordance with


Drawings

A Suspended slabs; 200 mm thick 79 m3 0.00

B Ditto; 200 mm thick; to landings and slabs 3 m3 0.00

C Ditto; 230 mm thick 175 m3 0.00

D Ditto; 250 mm thick 381 m3 0.00

E Ditto; 275 mm thick 15 m3 0.00

F Suspended beams 59 m3 0.00

G Shear walls; 200 mm thick 5 m3 0.00

H Ditto; 300 mm thick 17 m3 0.00

J Core walls; 200 mm thick 17 m3 0.00

K Ditto; 250 mm thick 13 m3 0.00

L Upstands 1 m3 0.00

M Staircases 5 m3 0.00

N Columns 60 m3 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUPERSTRUCTURE (CONT'D)

Reinforcement

Reinforcement; deformed bars to BS Standards; Grade 460


N/SQMM; all in accordance with the Drawings

A To suspended slabs 139,178.00 kg 0.00

B To suspended beams 15,430.00 kg 0.00

C To shear walls 5,361.00 kg 0.00

D To core walls 7,450.00 kg 0.00

E To upstands 44.00 kg 0.00

F To staircases 756.00 kg 0.00

G To columns 24,591.00 kg 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUPERSTRUCTURE (CONT'D)

Shuttering

Formwork; basic finish; all in accordance with the Drawings

A To soffits of suspended slabs 2,723 m2 0.00

B To sides of suspended slabs 149 m2 0.00

C To sides and soffits of suspended beams 572 m2 0.00

D To sides of shear walls 176 m2 0.00

E To sides of core walls 262 m2 0.00

F To sides of upstands 16 m2 0.00

G To soffits of stair landings 12 m2 0.00

H To sloping soffits of staircases 16 m2 0.00

J To sides of landings, treads and risers of staircases 16 m2 0.00

K To sides of columns 588 m2 0.00

L To edges; not exceeding 250 mm thick 113 m 0.00

M Ditto; 250 - 500 mm thick 511 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

SUPERSTRUCTURE (CONT'D)

Sundries

Allow for approved type machine foundation for mechanical


plants on roof slab as Detail 5 on Drawing S-00-004

A Mechanical plinths 1 item 0.00

Approved type void former as drawings

B Below ramp slab 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

PRECAST CONCRETE

Precast concrete lintels including reinforcement complete all


as Drawings S-00-003

A 200 x 200 mm depth (82 nos) 121 m 0.00

B 200 x 300 mm depth (6 nos) 28 m 0.00

C 200 x 400 mm depth (13 nos) 144 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 12


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION C - CONCRETE WORK (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Page: 13


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION C -Page: 1 0.00

BILL 02/SECTION C -Page: 2 0.00

BILL 02/SECTION C -Page: 3 0.00

BILL 02/SECTION C -Page: 4 0.00

BILL 02/SECTION C -Page: 5 0.00

BILL 02/SECTION C -Page: 6 0.00

BILL 02/SECTION C -Page: 7 0.00

BILL 02/SECTION C -Page: 8 0.00

BILL 02/SECTION C -Page: 9 0.00

BILL 02/SECTION C -Page: 10 0.00

BILL 02/SECTION C -Page: 11 0.00

BILL 02/SECTION C -Page: 12 0.00

BILL 02/SECTION C -Page: 13 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION C -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION D - MASONRY

All block work shall be in accordance with BS 2026 and


A Dubai Municipality General Order No 44/90, 108/90 and Note
blocks shall be from Municipality approved factory

WALLS AND PIERS

Solid concrete blockwork; bedded and jointed in (1:4)


cement and sand mortar with approved plasticizer, including
concrete restraint posts and beams, wall ties, joints, straps,
tie shots, head restraint, anchors, reinforcements and metal
lathing

B Type P01; 300 mm thick 284 m2 0.00

C Type P02; 250 mm thick 176 m2 0.00

D Type P03; 200 mm thick 866 m2 0.00

E Type P04; 150 mm thick 71 m2 0.00

F Type P05; 100 mm thick 172 m2 0.00

Insulated concrete blockwork; bedded and jointed in (1:4)


cement and sand mortar with approved plasticizer, including
concrete restraint posts and beams, wall ties, joints, straps,
tie shots, head restraint, anchors, reinforcements and metal
lathing

G Type P01; 300 mm thick 630 m2 0.00

H Type P02; 250 mm thick 54 m2 0.00

J Type P03; 200 mm thick 59 m2 0.00

K Type P04; 150 mm thick 142 m2 0.00

L Type P05; 100 mm thick 12 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION D -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION D - MASONRY (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION D -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION D -Page: 1 0.00

BILL 02/SECTION D -Page: 2 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION D -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK

COMPOSITE UNITS

Metal Staircases

Steel/metal stairs comprising of steel frames, steel base


plates, end plates, end caps with all necessary fixings and
accessories, support frame work fixed to concrete steps or
slabs as Drawing S03-002

A RHS 80 X 80 X 8 mm 10 m 0.00

B RHS 90 X 180 X 8 mm 48 m 0.00

C RHS 180 X 180 X 8 mm 21 m 0.00

D SHS 50 X 50 X 5 mm 126 m 0.00

Approved Steel plate or similar to receive architectural


E 4 m2 0.00
finishes for Landings

Approved Steel plate or similar to receive architectural


F 61 m 0.00
finishes for treads

Approved Steel plate or similar to receive architectural


G 67 m 0.00
finishes for risers

Allow for fittings and fixings, i.e. connecting plates, stiffener


plates, gusset plates, splices, caps, brackets, support
H 1 item 0.00
steelwork, bolts complete with washers, distance pieces,
rivets, and the like; To all metalwork

Allow for protective treatment including sand blasted surface


J preparation, epoxy based paint with a minimum DFT of 100 1 item 0.00
microns for internal surfaces

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK

Balustrades

Fully tempered frameless glass balustrade (W-501-E)


including base clamp, anchoring, concealed supports,
finishing, decorations, fixings and accessories complete as
detailed on Drawings 213-RD-AR-ZZZ-600

A Balconies/ Terraces, 1100 mm high 68 m 0.00

Fully tempered glass balustrade (J-500) and satin brass (J-


900) finished handrail including metal capping, metal base
clamp, anchoring, concealed supports, finishing,
decorations, fixings and accessories complete as detailed
on Drawings 213-RD-ID-ZZZ-560 to 562

B Staircase, 1100 mm high 36 m 0.00

Fully tempered glass balustrade (J-500) and satin brass (J-


900) finished handrail including metal capping, metal base
clamp, anchoring, concealed supports, finishing,
decorations, fixings and accessories complete

C Staircase, 825 mm high 17 m 0.00

14 mm thick mesh laminated glass balustrade with bulkhead


(J-505) consisting satin brass (J-900) finished handrail
including metal capping, metal base clamp, anchoring,
concealed supports, finishing, decorations, fixings and
accessories complete as detailed on Drawings 213-RD-ID-
ZZZ-560 to 562

D Staircase void areas, 2025 mm high 27 m 0.00

14 mm thick mesh laminated glass balustrade with bulkhead


(J-505) consisting satin brass (J-900) finished handrail
including metal capping, metal base clamp, anchoring,
concealed supports, finishing, decorations, fixings and
accessories complete

E Ground floor void areas, 2025 mm high 32 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK (CONT'D)

Handrails

40 x 40 mm wall mounted metal handrail in satin brass finish


(J-900) including brackets, cover plates, fittings, fixings and
necessary accessories complete

A To BOH stair 24 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK (CONT'D)

Noising

Anti-slip metal strip in (J-900) finish including concealed


fixings and accessories as Detail 6 on Drawings 213-RD-ID-
ZZZ-562

A To staircase 161 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK (CONT'D)

Batten Feature Wall

Satin brass batten feature wall panel (J-900) including all


necessary fittings, fixings and accessories complete as per
Manufacturer's recommendation

A To car park area 32 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK (CONT'D)

Corner Guard

High impact resistant rubber column corner guard, including


fixings and accessories complete

A 65 x 1000 mm high, to projected columns in carpark 42 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

NON-STRUCTURAL METALWORK (CONT'D)

Metal Transition Strip

Steel transition strip (F-905) at floor transition including


fixings and accessories complete as per Manufacturer's
recommendation

A To floors 194 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION E - METALWORK (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION E -Page: 1 0.00

BILL 02/SECTION E -Page: 2 0.00

BILL 02/SECTION E -Page: 3 0.00

BILL 02/SECTION E -Page: 4 0.00

BILL 02/SECTION E -Page: 5 0.00

BILL 02/SECTION E -Page: 6 0.00

BILL 02/SECTION E -Page: 7 0.00

BILL 02/SECTION E -Page: 8 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION E -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK

FINISHINGS AND FITTINGS

Vanity Units

Staff bathroom; vanity unit to an approved design comprising


vanity top, surrounds, splashback, fascia panel including
finishes, decorations, subframe, adhesive, fixings and
accessories complete

A BU-108, overall size 960 x 600 mm 3 Nr 0.00

Guest bathroom; vanity unit comprising marble tile (J-310-B)


vanity top and surrounds, wood veneered (J-407) shelf and
antifog mirror (J-503) panels with metal-satin brass (J-900)
trims including finishings, decorations, subframe, adhesive,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-000-604

B BU-208, overall size 1500 x 500 mm 1 Nr 0.00

Master bathroom 3; vanity unit comprising marble tile (J-310-


B) vanity top and surrounds, wood veneered (J-407) shelf
and antifog mirror (J-503) panels with metal-satin brass (J-
900) trims including finishings, decorations, subframe,
adhesive, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-000-604

C BU-208, overall size 1920 x 500 mm 1 Nr 0.00

Common washroom; vanity unit comprising marble


travertine (J-301) vanity top and surrounds, wood veneered
(J-407) shelf and antifog mirror (J-503) panels with metal-
satin brass (J-900) trims including finishings, decorations,
subframe, adhesive, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-000-604

D BU-209, overall size 1555 x 500 mm 1 Nr 0.00

Master bedroom 1; vanity unit comprising travertine stone (J-


309) vanity top and surrounds, wood veneered (J-407)
undercounter drawers, open shelf and side cabinet with
metal-satin brass (J-900) shelves and antifog mirror (J-503)
panels with metal-satin brass (J-900) trims including
finishings, decorations, frame, subframe, hardware,
adhesive, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-000-606

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Vanity Units (Cont'd)

Master bedroom 1; vanity unit comprising travertine stone (J


309) vanity top and surrounds, wood veneered (J-407)
undercounter drawers, open shelf and side cabinet with
metal-satin brass (J-900) shelves and antifog mirror (J-503)
panels with metal-satin brass (J-900) trims including
finishings, decorations, frame, subframe, hardware,
adhesive, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-000-606

A BU-212, overall size 2545 x 500 mm 1 Nr 0.00

Nursery; vanity unit and bath tub ledge comprising marble


tile (J-313) vanity top, bath tub top, side panels and wood
veneered (J-405) base units, antifog mirror (J-503) panels
with metal powdercoated (J-903) trims including finishings,
decorations, frame, subframe, hardware, adhesive,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-0B1-603

B BU-307, overall size 4550 x 900 mm, "L" shaped 1 Nr 0.00

Master bedroom 2; vanity unit comprising Hymalaya tile (J-


312) vanity top and surrounds, wood veneered (J-407) under
counter drawers and antifog mirror (J-503) panels with metal
satin brass (J-900) trims including finishings, decorations,
frame, subframe, hardware, adhesive, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-606

C BU-312, overall size 2400 x 500 mm 1 Nr 0.00

Kid's bathroom 1 & 2; vanity unit comprising marble tile (J-


313) vanity top and wood veneered (J-405) base units
including finishings, decorations, frame, subframe, hardware
adhesive, sealants, fixings and accessories complete

D BU-320, overall size 600 x 600 mm 1 Nr 0.00

E BU-321, overall size 600 x 600 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Vanity Units (Cont'd)

Common washroom; vanity unit comprising marble


travertine (J-301) vanity top and surrounds, wood veneered
(J-404) shelf and antifog mirror (J-503) panels with metal-
satin brass (J-900) trims including finishings, decorations,
subframe, adhesive, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0R1-604

A BU-411, overall size 910 x 500 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture

Wine cellar; bar table comprising wood veneered (J-407)


table top and side panels, metal - patina (J-901) 3 no. of
legs with metal trims including finishings, decorations,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-0B1-600

A BU-103, overall size 3770 x 350 x 940 mm 1 Nr 0.00

Wine cellar; wine rack comprising metal - satin brass (J-900)


framing and leather (J-813) straps as required including
finishings, decorations, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0B1-601

B BU-104, overall size 570 x 165 x 2400 mm 4 Nr 0.00

Wine cellar; coved feature wall comprising light cove at both


edges including blocking and framing as required, gypsum/
plasterboard wall lining with textured (W-200) paint finish
finishings, trimmings, substrates, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0B1-601

C BU-105, overall size 3250 x 930 x 2350 mm, curved on plan 1 Nr 0.00

Staff 1; wardrobe and dressing unit comprising wood


veneered (J-407) doors, side panels, dividers, drawers,
metal - satin brass (J-900) finger pull handle and laminate (J-
408) dressing unit work top, surrounds and drawers, antifog
mirror (J503) including finishings, decorations, trimmings,
primary structural framing, secondary concealed frame
work, hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0B1-602

D BU-106, overall size 4200 x 600 x 2400 mm 1 Nr 0.00

Staff room; TV unit comprising laminate (J-408) base unit,


wood veneered (J-407) shelf, ribbed wood (J-410) back
panel including finishings, decorations, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0B1-600

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Staff room; TV unit comprising laminate (J-408) base unit,


wood veneered (J-407) shelf, ribbed wood (J-410) back
panel including finishings, decorations, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0B1-600

A BU-107, overall size 4500 x 350 x 2400 mm 3 Nr 0.00

Laundry; joinery unit comprising wood veneered (J-407)


open shelves, skirting and laminate (J-408) wardrobe,
worktop, wall units, base units including finishings,
decorations, trimmings, primary structural framing,
secondary concealed frame work, hardware, hanging rods,
substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0B1-603

B BU-109, overall size 7730 x 600 x 2400 mm, "U" shaped 1 Nr 0.00

Staff 2 & 3; wardrobe comprising wood veneered (J-407)


sides and door panels with metal - satin brass (J-900) finger
pull handle including finishings, decorations, trimmings,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0B1-602

C BU-110, overall size 2035 x 600 x 2400 mm 2 Nr 0.00

Wine cellar; table (oval shaped) comprising marble (J-322)


finished top and metal - satin brass (J-900) finished standing
units including finishings, decorations, trimmings, sealants,
fixings and accessories complete as detailed on Drawing
213-RD-ID-0B1-604

D BU-111, overall size 2120 x 1400 x 900 mm 1 Nr 0.00

Common bathroom; towel/soap holder in metal - satin brass


(J-900) finish including finishings, trimmings, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-000-600

E BU-200, overall size 400 x 100 x 30 mm 3 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Corridor; breakfast table comprising wood veneered (J-407)


finished top, marble - cappucino (J-307) finished base unit
with brown smoked glass (J-500) base with metal profile (J-
900) around including finishings, decorations, trimmings,
fixings and accessories complete as detailed on Drawing
213-RD-ID-000-600

A BU-201, overall size 4500 x 1000 x 750 mm 1 Nr 0.00

Counter; Bar back comprising wood veneered (J-407) sides


and door panels with metal - satin brass (J-900) handle,
crystal clear glass (J-500) centre shelving unit with metal -
satin brass (J-900) framing including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-601

B BU-202, overall size 4285 x 630 x 3200 mm 1 Nr 0.00

Living room; fire place comprising stone (J-321) finished


base unit, marble - cappucino (J-302) finished fire place unit,
metal (J-900) finished shelving and marble - travertine (J-
301) finished plain and grooved back wall panel including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-000-601

C BU-203, overall size 7450 x 740 x 3000 mm 1 Nr 0.00

Living room; TV unit comprising metal - satin brass (J-900)


finished corner shelving unit, marble - cappucino (J-302)
finished and marble - travertine (J-301) finished plain and
grooved fixed wall panel including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-602

D BU-204, overall size 7455 x 400 x 3950 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Office; shelving unit comprising marble (J-323) base unit,


wood veneered (J-404) drawers, paint (J-214) finished front
panel with metal - satin brass (J-900) finished and wood
veneered (J-404) shelves including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-602

A BU-205, overall size 2930 x 500 x 3200 mm 1 Nr 0.00

Guest room; TV unit consisting of metal - satin brass (J-900)


finished and wood veneered (J-407) shelving unit, tile (J-
317) finished drawers and natural, satin finished ribbed wood
(J-410) back panel and TV including finishings, decorations,
trimmings, metal skirting, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-000-603

B BU-206, overall size 5250 x 350 x 3000 mm 1 Nr 0.00

Guest room; head wall comprising marble-travertine (J-301)


finish, satin finished ribbed wood (J-410) wall panel and
metal - satin brass (J-900) finished strips including finishings
decorations, trimmings, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-000-603

C BU-207, overall size 3860 x 100 x 1100 mm 1 Nr 0.00

Counter; bar island comprising marble tile (J-324) work top,


surrounds and marble - cappucino (J-302) shelves and
dividing panels hanged with metal - satin brass (J-900)
supports including frame, sub frame, finishings, decorations,
trimmings, adhesive, substrates, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-605

D BU-210, overall size 3000 x 1200 x 1200 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Master bedroom 1; head wall comprising atlas patterned


wall paper (J-800) and textured paint (J-200) finish, satin
brass (J-900) finished metal profiles including finishings,
decorations, trimmings, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-000-606

A BU-211, overall size 4300 x 150 x 3000 mm 1 Nr 0.00

Master bathroom 1; shower bench and shelves comprising


of marble tile (J-309) bench top and surrounds, metal - satin
brass (J-900) 4 no. of shelves including frame, sub frame,
finishings, decorations, trimmings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-607

B BU-214, overall size 1800 x 450 x 3130 mm 1 Nr 0.00

Pooja room; plinth, wall panels and MDF shelves with metal
cladding including frame, sub frame, forming wall niches, all
surfaces to receive finishes (measured elsewhere),
finishings, trimmings, sealants, fittings, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
000-607

C BU-215, overall size 3580 x 3310 x 3000 mm 1 Nr 0.00

Dining area; console comprising stone tile (J-324) finished


top and 1 number of marble - cappucino (J-302) finished
standing unit with metal - satin brass (J-900) finished trim
around with brass finished anti slip glides and 1 number of
metal - satin brass (J-900) finished standing units with nylon
glids including finishings, decorations, trimmings, sealants,
fixings and accessories complete as detailed on Drawing
213-RD-ID-000-608

D BU-216, overall size 1480 x 400 x 900 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Guest bedroom; shelving unit in metal - satin brass (J-900)


finished including finishings, decorations, trimmings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-000-608

A BU-217, overall size 1100 x 250 x 1600 mm 1 Nr 0.00

Kids' bedroom 1; loft bed unit comprising wood veneered (J-


405) stair, fabric cladded (J-809) wall panels, safety net (J-
700), platform, loft deck and customized bed including
primary structural framing, secondary concealed frame
work, gypsum/ plasterboard wall lining, finishings,
decorations, trimmings, skirting, substrates, sealants,
fittings, fixings and accessories complete as detailed on
Drawing 213-RD-ID-001-600

B BU-301, overall size 3900 x 4075 x 2800 mm 1 Nr 0.00

Nursery; shelving unit comprising wood veneered (J-405)


side panels, MDF shelves with PVC lipping and overhead
shutters including finishings, decorations, trimmings, skirting,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-001-600

C BU-302, overall size 1300 x 450 x 2980 mm 1 Nr 0.00

Nursery; wardrobe comprising paint (J-215) finished side


panels and plain and routed wood door panels with metal -
satin brass (J-900) finished handle, paint (J-215) finished
routed and ribbed wood front panels and wood veneered (J-
405) shelves including finishings, decorations, trimmings,
skirting, primary structural framing, secondary concealed
frame work, substrates, hardware, linings, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-001-601

D BU-303, overall size 2670 x 600 x 2780 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Nursery; feature wall unit comprising fabric cladded (J-807)


wall panels and paint (J-205/215) wall panels including
finishings, decorations, trimmings, metal skirting, primary
structural framing, secondary concealed frame work,
substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0B1-601

A BU-304, overall size 3765 x 50 x 3000 mm 1 Nr 0.00

Nursery; wardrobe comprising paint (J-205/215) finished


side and door panels with gold finished handle, paint (J-205)
finished routed wood front panels and wood veneered (J-
405) centre shelving unit including finishings, decorations,
trimmings, metal skirting, primary structural framing,
secondary concealed frame work, hardware, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0B1-602

B BU-305, overall size 2670 x 600 x 2780 mm 1 Nr 0.00

Nursery bathroom; shelves comprising paint (J-205) finished


door panels with finger pull handle and paint (J-215) finished
MR MDF adjustable shelves including finishings,
decorations, trimmings, metal skirting, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0B1-602

C BU-306, overall size 1620 x 400 x 2580 mm 1 Nr 0.00

Nursery; vanity bath tub comprising stone tile (J-313) finish,


wood veneered (J-405) under counter cabinetry with stone
tile (J-313) finished vanity counter top (vanity counter top
measured separately), crystal clear (J-505) glass panels
with metal - powder coated (J-903) finished trim around and
antifog mirror (J503) panels with metal - powder coated (J-
903) finished trim around including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0B1-603

D BU-307, overall size 2900 x 2250 x 2600 mm 1 Nr 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Kids bedroom; TV unit comprising honed terrazzo (J-325)


finished base unit, fabric cladded (J-808) overhead shelving
and door panels with gold finished handle, wallpaper (J-808)
finished wall panel including finishings, decorations,
trimmings, metal skirting, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-001-603

A BU-308, overall size 1560 x 520 x 3000 mm 1 Nr 0.00

Kids bed room; study unit comprising paint (J-215) finished


front panel, door panel with metal handle and work top and
routed fascia, 2 number of side shelving unit in paint (J-215)
finish and fabric cladded (J-808) and wood veneered (J-405)
fixed panels including finishings, decorations, trimmings,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-001-603

B BU-309, overall size 5590 x 600 x 3000 mm 1 Nr 0.00

Kids bed room 1; wardrobe comprising fabric cladded (J-


808) side, back and door panels with metal - satin brass (J-
900) finished handle, paint (J-215) finished routed wood
drawers and front fixed panels, paint (J-215) finished corner
shelving unit with antifog mirror (J-503) panel including
finishings, decorations, trimmings, metal skirting, primary
structural framing, secondary concealed frame work,
hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0B1 604

C BU-310, overall size 2985 x 600 x 3000(assumed) mm 1 Nr 0.00

Master bedroom 2; head wall comprising marble-travertine


(J-301) finished wall panel, brown tinted glass (J-507) panel
with satin brass (J-900) finished metal trim around, dry
pampas (J-701) to in side of glass panel and 2 number of
marble-travertine (J-301) finished side table units including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-001-605

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Master bedroom 2; head wall comprising marble-travertine


(J-301) finished wall panel, brown tinted glass (J-507) panel
with satin brass (J-900) finished metal trim around, dry
pampas (J-701) to in side of glass panel and 2 number of
marble-travertine (J-301) finished side table units including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-001-605

A BU-313, overall size 3320 x 500 x 3000 mm 1 Nr 0.00

Master bed 3; shelving unit comprising work top with ombre


glass (J-505) top, wood veneered (J-407) fascia and satin
brass (J-900) finished bottom metal cladding and wood
veneered (J-407) and metal - satin brass (J-900) finished
shelves including finishings, decorations, trimmings, primary
structural framing, secondary concealed frame work,
substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-001-606

B BU-314, overall size 6010 x 700 x 3000 mm 1 Nr 0.00

Master bedroom 3; shelving unit (special shaped)


comprising wood veneered (J-407) base unit, wood
veneered (J-407) and brown tinted glass (J-507) finished
shelves, metal - satin brass (J-900) finished front and head
panel and wood veneered (J-407) seating unit with fabric (J-
805) finished upholstery including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
001 606

C BU-317, overall 11345 x 600 x 3000 mm 1 Nr 0.00

Guest bedroom 2; TV unit comprising stone tile (J-307)


finished drawer units and wood veneered (J-407) and metal -
satin brass (J-900) finished shelving units including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-001-607

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 12


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Guest bedroom 2; TV unit comprising stone tile (J-307)


finished drawer units and wood veneered (J-407) and metal -
satin brass (J-900) finished shelving units including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-001-607

A BU-318, overall size 5665 x 450 x 3000 (assumed) mm 1 Nr 0.00

Guest bedroom 2; vanity unit comprising stone tile (J-310)


finished top with antifog mirror (J-503) panel (round shaped)
and metal - satin brass (J-900) finished tubular frame
support at ceiling and floor including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-001-607

B BU-319, overall size 2625 x 575 x 2800 mm 1 Nr 0.00

Kid's bed room 2; wardrobe comprising wood veneered (J-


405) side, back and door panels with paint (J-215) finished
handle, paint (J-215) finished corner and under shelving unit
including finishings, decorations, trimmings, metal skirting,
primary structural framing, secondary concealed frame
work, hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
001-608

C BU-322, overall size 3270 x 600 x 3200 (assumed) mm 1 Nr 0.00

Kid's bedroom 2; head wall comprising fabric cladded (J-


809) finish with fabric cladded (J-807/ 814/ 815) round
decorative units including finishings, decorations, trimmings,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-001-608

D BU-323, overall size 3530 x 3200 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 13


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Seating area; console comprising brown smoked glass (J-


502) top with stone tile (J-324) finished standing units
including finishings, decorations, trimmings, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-001-609

A BU-324, overall size 2500 x 500 x 450 mm 1 Nr 0.00

Master bedroom 2; shelving unit in metal - satin brass (J-


900) finished including finishings, decorations, trimmings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-001-609

B BU-325, overall size 5665 x 450 x 3000 (assumed) mm 1 Nr 0.00

Spa; vanity unit comprising stone (J-310) finished top, and


splash back consisting of both side full hight cabinets with
wood veneered (J-407) sides and fabric cladded (J-804)
door panels and centre shelving unit with antifog mirror
(J503) panels including finishings, decorations, trimmings,
solid timber skirting, primary structural framing, secondary
concealed frame work, substrates, linings, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-0R1-600

C BU-401, overall size 3300 x 600 x 3000 mm 1 Nr 0.00

Spa salon; shelving unit comprising overhead and under


shelving in wood veneered finish (J-407), antifog mirror (J-
503) panels and satin brass finished shelves including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0R1-BU401 & 402

D BU-402, overall size 3300 x 600 x 3000 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 14


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Gym; shelving unit comprising stone tile finish (J-324)


counter top, top and side panels consisting of metal-satin
brass (J-900) finished shelves, wood veneered (J-404)
under counter cabinetry including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0R1-601

A BU-404, overall size 3760 x 700 x 2925 mm 1 Nr 0.00

Gym; feature wall unit comprising metal-satin brass (J-900)


finished mesh, customized shelf, metal holders and hooks
including finishings, decorations, trimmings, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-0R1-601

B BU-405, overall size 3760 x 700 x 2925 mm 1 Nr 0.00

Wine lounge; bar unit comprising marble - cappucino (J-302)


finished top, paint (J-209) finished standing unit and paint (J-
212B) finished base unit with metal-satin brass (J-900)
finished trim around including finishings, decorations,
trimmings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0R1-602

C BU-407, overall size 2600 x 900 x 1100 mm 1 Nr 0.00

Wine lounge; back bar unit comprising 2 no. of full hight


marble - cappucino (J-302) and metal-satin brass (J-900)
finished shelving unit with mesh laminated glass (J-505) doo
panels, 2 number of full hight paint (J-212B) finished shelving
unit and drawers with mesh laminated glass (J-505) door
panels, marble - cappucino (J-302) finished fire place unit
and routed fixed and sliding panels, crystal clear glass (J-
500) centre shelving unit with metal trim and brass bevelled
smoked mirror (J-504) and marble - cappucino (J-302) back
panel, wood veneered (J-406) fixed panels and TV including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0R1-602

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 15


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Wine lounge; back bar unit comprising 2 no. of full hight


marble - cappucino (J-302) and metal-satin brass (J-900)
finished shelving unit with mesh laminated glass (J-505) doo
panels, 2 number of full hight paint (J-212B) finished shelving
unit and drawers with mesh laminated glass (J-505) door
panels, marble - cappucino (J-302) finished fire place unit
and routed fixed and sliding panels, crystal clear glass (J-
500) centre shelving unit with metal trim and brass bevelled
smoked mirror (J-504) and marble - cappucino (J-302) back
panel, wood veneered (J-406) fixed panels and TV including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing 213-RD-ID-0R1-602

A BU-408, overall size 8195 x 600 x 2925 mm 1 Nr 0.00

Kid's play; TV unit comprising wall panel, drawers and wood


veneered (J-405) shelves including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0R1-603

B BU-409, overall size 3250 x 400 x 2925 mm 1 Nr 0.00

Kid's play; climbing wall unit comprising appropriate (J-702)


finished climbing grips, metal - powder coated (J-904)
finished step rungs fabric (J-809) finished floor cushion unit
including finishings, decorations, trimmings, sealants, fixings
and accessories complete as detailed on Drawing 213-RD-
ID-0R1-603

C BU-410, overall size 2900 x 1000 x 2925 mm 1 Nr 0.00

Cinema; console unit comprising wood veneered (J-404)


finish with metal-satin brass (J-900) finished trim including
finishings, decorations, trimmings, solid timber skirting,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-0R1-605

D BU-413, overall size 4535 x 400 x 300 mm 1 Nr 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 16


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Cinema; pantry unit comprising dekton (J-324) finish, metal-


satin brass (J-900) finished and wood veneered (J-404)
shelves and front panel and brass bevelled smoked mirror (J
504) and wood veneered (J-404) back panel including
finishings, decorations, trimmings, solid timber skirting,
primary structural framing, secondary concealed frame
work, hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0R1-605

A BU-414, overall size 2110 x 600 x 2625 mm 1 Nr 0.00

Cinema; seating comprising leather (J-816) finish wood


veneered (J-404) base unit including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0R1-606

B BU-416, overall size 3400 x 2000 mm 1 Nr 0.00

Golf simulation; shelving comprising stone tile (J-324)


finished top on metal-satin brass (J-900) finished base,
wood veneered (J-404) under counter cabinetry on metal-
satin brass (J-900) finished base unit and metal-satin brass
(J-900) finished shelving unit including finishings,
decorations, trimmings, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawing 213-RD-ID-0R1-604

C BU-417, overall size 1340 x 650 x 1400 mm 1 Nr 0.00

Spa; partition comprising mesh laminated glass (J-501)


finish with metal-satin brass (J-900) finished trim around
including finishings, decorations, trimmings, fixings and
accessories complete as detailed on Drawing 213-RD-ID-
0R1 606

D BU-418, overall size 1050 x 50 x 2825 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 17


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (Cont'd)

Guest bathroom 2; joinery unit including finishings,


decorations, trimmings, primary structural framing,
secondary concealed frame work, substrates, linings,
sealants, fixings and accessories complete as detailed on
Drawings and all in accordance with Specifications

A Overall size 816 x 250 mm 1 Nr 0.00

Guest bathroom; 2 no. of hanging shelves including 2 no. of


metal - satin brass (J-900) supports, finishings, decorations,
sealants, fixings and accessories complete

B Overall size 816 x 250 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 18


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (By Specialist)

Wine cellar; storage unit comprising 2 no. of 102 bottle


storage units and 10 no. of 146 bottle storage units including
finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing FINTD-RT-21-551- LV48- ROAR
INTERIORS - KITCHEN_R2

A BU-102 1 Nr 0.00

Pot wash area; shelving unit (U - shaped) comprising wall


units, tall shelved storage, vanity counters (sanitary ware
measured separately) with splash back, and under counter
cabinetry units including finishings, decorations, trimmings,
primary structural framing, secondary concealed frame
work, substrates, linings, sealants, fixings and accessories
complete as detailed on Drawing FINTD-RT-21-551- LV48-
ROAR INTERIORS - KITCHEN_R2

B BU-218 1 Nr 0.00

Main kitchen; shelving unit (special shaped) comprising wall


units with integrated hood, base drawer unit for built in hobs,
wall unit with shelves, base units with built in ovens, tall unit
with built in microwave/ coffee machine, tall unit with shelves
open shelving, tall unit with integrated fridge and freezer,
drawer base units, corner tall unit with pull out leman
accessory, 45 glass tall unit, fixed panels and vanity counters
(sanitary ware measured separately) with splash back
including finishings, decorations, trimmings, primary
structural framing, secondary concealed frame work,
substrates, linings, sealants, pop out socket, fixings and
accessories complete as detailed on Drawing FINTD-RT-21-
551- LV48- ROAR INTERIORS - KITCHEN_R2

C BU-219 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 19


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (By Specialist) (Cont'd)

Master bedroom1; wardrobe (U - shaped) comprising full


height shelves, suspended glass drawer with shirt grid,
suspended shelf with trinket tray, shelves with safe, half
hanger unit with drawers, full hanger units, double hanger
units, drawers with glass shelves, half hanger unit with trinke
tray and trouser tray, full height mirrors, island with leather
top and solid front drawers including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, hardware, substrates, linings, sealants, fixings
and accessories complete as detailed on Drawing FINTD-
RT-22-552-JUMEIRAH BAY WARDROBES-REV.02

A BU-220, overall size 6060 x 4160 x 3000 mm 1 Nr 0.00

Linen closet; wardrobe (L- shaped) comprising full height


shoe rack shelves, adjustable shelves and deep drawers
with adjustable shelves including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, hardware, substrates, linings, sealants, fixings
and accessories complete as detailed on Drawing FINTD-
RT-22-552-JUMEIRAH BAY WARDROBES-REV.02

B BU-221, overall size 3301 x 1890 x 3000 mm 1 Nr 0.00

Guest bedroom; wardrobe (L- shaped) comprising full height


double hanging units, half hanging units with drawers and
corner long hanging units including finishings, decorations,
trimmings, primary structural framing, secondary concealed
frame work, hardware, substrates, linings, sealants, fixings
and accessories complete as detailed on Drawing FINTD-
RT-22-552-JUMEIRAH BAY WARDROBES-REV.02

C BU-222, overall size 2308 x 1870 x 3000 mm 1 Nr 0.00

Linen closet; wardrobe (L-shaped) comprising full height


shelves, shelves with deep drawers and corner shelves
including finishings, decorations, trimmings, primary
structural framing, secondary concealed frame work,
hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing FINTD-RT-22-
552-JUMEIRAH BAY WARDROBES-REV.02

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 20


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (By Specialist) (Cont'd)

Linen closet; wardrobe (L-shaped) comprising full height


shelves, shelves with deep drawers and corner shelves
including finishings, decorations, trimmings, primary
structural framing, secondary concealed frame work,
hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing FINTD-RT-22-
552-JUMEIRAH BAY WARDROBES-REV.02

A BU-311, overall size 2985 x 3260 x 3000 mm 1 Nr 0.00

Guest bedroom 2; wardrobe (L- shaped) comprising full


height long hanging units, shoe rack with shelves,
suspended drawer unit with half hanging unit, double hanging
unit, suspended shelf with mirror panel including finishings,
decorations, trimmings, primary structural framing,
secondary concealed frame work, hardware, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawing FINTD-RT-22-552-JUMEIRAH BAY
WARDROBES-REV.02 and all in accordance with
Specifications

B BU-326, overall size 4383 x 1900 x 3000 mm 1 Nr 0.00

Master bedroom 2; wardrobe (special shaped) comprising


full height shelves, corner full hanging units, full hanging
units, drawer with glass shelves, half hanging units with
trinket tray and trouser tray, shoe rack with shelves,
suspended shelf with trinket tray, half hanging unit with
drawers, suspended shelves with drawers, suspended
shelves, island with leather top and solid front drawers
including finishings, decorations, trimmings, primary
structural framing, secondary concealed frame work,
hardware, substrates, linings, sealants, fixings and
accessories complete as detailed on Drawing FINTD-RT-22-
552-JUMEIRAH BAY WARDROBES-REV.02

C BU-327, overall size 4720 x 5370 x 3000 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 21


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Fixed Furniture (By Specialist) (Cont'd)

Master bedroom 3; wardrobe (special shaped) comprising


full height shoe rack with shelves, drawers with shelves, full
hanging units, corer full hanging units, suspended drawer
with half hanging unit, suspended shelf with trinket tray,
drawer with half hanging unit, double hanging units, island
with leather top and solid front drawers including finishings,
decorations, trimmings, primary structural framing,
secondary concealed frame work, substrates, hardware,
linings, sealants, fixings and accessories complete as
detailed on Drawing FINTD-RT-22-552-JUMEIRAH BAY
WARDROBES-REV.02

A BU-328, overall size 6095 x 5400 x 3000 mm 1 Nr 0.00

Pantry and utility area; shelving unit (L - shaped) including


finishings, decorations, trimmings, primary structural
framing, secondary concealed frame work, substrates,
linings, sealants, fixings and accessories complete as
detailed on Drawings

B BU-412 1 Nr 0.00

Sauna; joinery work and furniture to an approved design


including finishes, primary and secondary frame work,
decorations, accessories and fixing complete

C Sauna joinery ( Appox. 3 m2) 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 22


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION F - WOODWORK (CONT'D)

FINISHINGS AND FITTINGS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Page: 23


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION F -Page: 1 0.00

BILL 02/SECTION F -Page: 2 0.00

BILL 02/SECTION F -Page: 3 0.00

BILL 02/SECTION F -Page: 4 0.00

BILL 02/SECTION F -Page: 5 0.00

BILL 02/SECTION F -Page: 6 0.00

BILL 02/SECTION F -Page: 7 0.00

BILL 02/SECTION F -Page: 8 0.00

BILL 02/SECTION F -Page: 9 0.00

BILL 02/SECTION F -Page: 10 0.00

BILL 02/SECTION F -Page: 11 0.00

BILL 02/SECTION F -Page: 12 0.00

BILL 02/SECTION F -Page: 13 0.00

BILL 02/SECTION F -Page: 14 0.00

BILL 02/SECTION F -Page: 15 0.00

BILL 02/SECTION F -Page: 16 0.00

BILL 02/SECTION F -Page: 17 0.00

BILL 02/SECTION F -Page: 18 0.00

BILL 02/SECTION F -Page: 19 0.00

BILL 02/SECTION F -Page: 20 0.00

BILL 02/SECTION F -Page: 21 0.00

Carried To Next Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION (CONT'D)

Total Brought Forward from Page No. (Cont'd) 0.00

BILL 02/SECTION F -Page: 22 0.00

BILL 02/SECTION F -Page: 23 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION F -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION G - THERMAL & MOISTURE PROTECTION

SUBSTRUCTURE

Approved waterproof membrane including all associated


fixings, laid strictly in accordance with the manufacturer's
instructions

A Horizontal and sloping surfaces 935 m2 0.00

B Vertical surfaces 453 m2 0.00

Approved Type protection board including all associated


fixings, laid strictly in accordance with the manufacturer's
instructions

C Vertical surfaces 107 m2 0.00

Two coats of rubberized bituminous paint (20% rubber


content) as Drawings S-02-004

D On sides of sub structural block work 53 m2 0.00

1000 gauge polythene sheet on compacted ground

E Below blinding 34 m2 0.00

F Below on grade slab 77 m2 0.00

Waterproofing system with 600mm wide reinforcing strip,


300mm wide detail strip and surface water bar as Detail 06
of Drawing S-00-005

G Bottom corner of raft foundation 134 m 0.00

Waterproofing system with 300mm wide detail strip, forming


chamfres and 40 x 40 bituminous mastic fillets as Detail 06
of Drawing S-00-005

H Top corner of raft foundation 134 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION G - THERMAL & MOISTURE PROTECTION


(CONT'D)

SUPERSTRUCTURE

Coverings and Linings

Flat roof built-up including substrate preparations, adhesives


trims, waterproofing and necessary accessories complete
as per Manufacturer's recommendation

A Horizontally 299 m2 0.00

B Vertically, to upturns 108 m 0.00

Waterproofing to external area including substrate


preparations, adhesives, trims and necessary accessories
complete as per Manufacturer's recommendation

C To balconies and roof terraces 445 m2 0.00

D Vertically, to upturns 280 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION G - THERMAL & MOISTURE PROTECTION


(CONT'D)

SUPERSTRUCTURE (CONT'D)

Wet Area Waterproofing

Wet area waterproofing including substrate preparations,


adhesives, trims and necessary accessories complete as
per Manufacturer's recommendation

A To floors 272 m2 0.00

B To walls 445 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION G - THERMAL & MOISTURE PROTECTION


(CONT'D)

SUPERSTRUCTURE (CONT'D)

Thermal Insulation

Thermal insulation including necessary fixings and


accessories complete as per Manufacturer's
recommendation

A To soffits of balcony areas 31 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION G - THERMAL & MOISTURE PROTECTION


(CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION G -Page: 1 0.00

BILL 02/SECTION G -Page: 2 0.00

BILL 02/SECTION G -Page: 3 0.00

BILL 02/SECTION G -Page: 4 0.00

BILL 02/SECTION G -Page: 5 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION G -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS

DOORS

External Doors

Wooden pocket sliding door and frame including hardware,


finishing, decorations, sealants, fixings and accessories
complete as detailed on Drawing 213-RD-AR-ZZZ-700

A Type D01, single sliding door, overall size 4000 x 3100 mm 1 Nr 0.00

Metal door and frame including door frame, sub-framing,


structural framing for overhead panel, finishing, decorations,
(door hardware measured separately), sealants, fixings and
accessories complete as detailed on Drawing 213-RD-AR-
ZZZ-701

B Type D08, single swing door, overall size 1065 x 2950 mm 1 Nr 0.00

Frameless glass screen consisting 32 mm thick infill glass


including hardware, fittings, fixings and accessories
complete as shown on Drawings 213-RD-AR-ZZZ-700 and
701

Type D02, overall size 4000 x 3075 mm comprising two way


C 1 Nr 0.00
sliding doors

Type D03, overall size 8300 x 3155 mm comprising two way


D 2 Nr 0.00
sliding doors

Type D04, overall size 8490 x 3155 mm comprising one way


E 1 Nr 0.00
double sliding doors

Type D05, overall size 8300 x 3155 mm comprising one way


F 1 Nr 0.00
double sliding doors

Type D06, overall size 9890 x 2950 mm comprising two way


G 1 Nr 0.00
sliding doors

Type D07a, overall size 4430 x 2950 mm comprising one


H 1 Nr 0.00
way single sliding door

Type D07b, overall size 4575 x 2950 mm comprising one


J 1 Nr 0.00
way single sliding door

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

External Doors (Cont'd)

Frameless glass screen consisting 32 mm thick infill glass


including hardware, fittings, fixings and accessories
complete as shown on Drawings 213-RD-AR-ZZZ-700 and
701 (Cont'd)

Type D09, overall size 3630 x 1150 mm comprising single


A 1 Nr 0.00
swing door

Type D10, overall size 5680 x 1150 mm comprising single


B 1 Nr 0.00
swing door

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

Internal Doors

Door panel with both sides finished in wood veneered (J-


407), consisting of single door and overhead fixed panel
including door frame, sub-framing, structural framing for
overhead panel, finishing, decorations, (door hardware
measured separately), sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-ZZZ-700, 213-
RD-ID-ZZZ-701

Type D50, overall size 955 x 3200 mm comprising 855 x


A 11 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D50, overall panel, size 955 x 3000 mm comprising


B 2 Nr 0.00
855 x 2580 mm single swing door, 35dB acoustic rated

Type D50, overall size 955 x 2825 mm comprising 855 x


C 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D50, overall size 955 x 3125 mm, comprising 855 x


D 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D50, overall size 955 x 3025 mm, comprising 855 x


E 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D50, overall size 955 x 2925 mm, comprising 855 x


F 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D51, overall size 855 x 2600 mm, comprising 755 x


G 6 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D51, overall size 855 x 3200 mm, comprising 755 x


H 2 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D52, overall size 1055 x 3000 mm comprising 955 x


J 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D53, overall size 950 x 3000 mm comprising 850 x


K 1 Nr 0.00
2570 mm single swing door, 35dB acoustic rated

Type D56, overall size 855 x 3000 mm comprising 755 x


L 2 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

Internal Doors (Cont'd)

Door panel with both sides finished in wood veneered (J-


407), consisting of single door and overhead fixed panel
including door frame, sub-framing, structural framing for
overhead panel, finishing, decorations, (door hardware
measured separately), sealants, fixings and accessories
complete as detailed on Drawing 213-RD-ID-ZZZ-700, 213-
RD-ID-ZZZ-701 (Cont'd)

Type D56, overall size 855 x 3025 mm comprising 755 x


A 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Type D56, overall size 855 x 2825 mm comprising 755 x


B 1 Nr 0.00
2580 mm single swing door, 35dB acoustic rated

Door panel with one side cladded with travertine marble (J-
301) and other side finished with textured paint (J-200)
consisting of single door and overhead fixed panel including
door frame, sub-framing, structural framing for overhead
panel, finishing, decorations (door hardware measured
separately), sealants, fixings and accessories as detailed on
Drawing 213-RD-ID-ZZZ-701 and all in accordance with
Specifications

Type D54, overall size 1050 x 3125 mm comprising 950 x


C 2 Nr 0.00
2570 mm single swing door, 35dB acoustic rated

Wood veneered (J-407) door including door frame, sub-


framing, finishing, decorations (door hardware measured
separately), sealants, fixings and accessories as detailed on
Drawing 213-RD-ID-ZZZ-701 and all in accordance with
Specifications

Type D55, overall size 955 x 2600 mm single swing door,


D 1 Nr 0.00
35dB acoustic rated

Door panel with both sides finished in wood veneered (J-


407), consisting of sliding double sash door and overhead
fixed panel including door frame, sub-framing, structural
framing for overhead panel, finishing, decorations, door
hardware and sliding gears, sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-701
and all in accordance with Specifications

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

Internal Doors (Cont'd)

Door panel with both sides finished in wood veneered (J-


407), consisting of sliding double sash door and overhead
fixed panel including door frame, sub-framing, structural
framing for overhead panel, finishing, decorations, door
hardware and sliding gears, sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-701
and all in accordance with Specifications

Type D57, overall size 1600 x 3200 mm comprising 1500 x


A 1 Nr 0.00
2600 mm sliding double sash door, 35dB acoustic rated

Type D57.1, overall size 2000 x 3200 mm comprising 1900 x


B 2 Nr 0.00
2600 mm sliding double sash door, 35dB acoustic rated

Wood veneered (J-407) door including door frame, sub-


framing, finishing, decorations (door hardware measured
separately), sealants, fixings and accessories as detailed on
Drawing 213-RD-ID-ZZZ-702 and all in accordance with
Specifications

Type D58, overall size 855 x 2400 mm single swing door,


C 8 Nr 0.00
35dB acoustic rated

Type D59, overall size 855 x 2400 mm single swing door,


D 2 Nr 0.00
35dB acoustic rated

Door with ribbed patterned wood veneered (J-407) front and


texture painted (J-200) back including door frame, sub-
framing, finishing, decorations (door hardware measured
separately), sealants, fixings and accessories as detailed on
Drawing 213-RD-ID-ZZZ-702 and all in accordance with
Specifications

Type D60, overall size 960 x 2400 mm single swing door,


E 1 Nr 0.00
35dB acoustic rated

Mesh laminated glass (J-501) door including brass (J-901)


finished door frame, sub-framing, finishing, decorations
(door hardware measured separately), sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-702
and all in accordance with Specifications

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

Internal Doors (Cont'd)

Mesh laminated glass (J-501) door including brass (J-901)


finished door frame, sub-framing, finishing, decorations
(door hardware measured separately), sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-702
and all in accordance with Specifications

Type D61, overall size 2000 x 2400 mm single swing double


A 1 Nr 0.00
door, 35dB acoustic rated

Mesh laminated glass (J-501) door including door frame,


sub-framing, finishing to Engineer's approval, decorations
(door hardware measured separately), sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-703
and all in accordance with Specifications

Type D62, overall size 2000 x 3000 mm single swing double


B 1 Nr 0.00
door, 35dB acoustic rated

Door panel with both sides finished in wood veneered (J-


407), consisting of sliding single sash door and overhead
fixed panel including door frame, sub-framing, structural
framing for overhead panel, finishing, decorations, door
hardware and sliding gears, sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-703
and all in accordance with Specifications

Type D63, overall size1460 x 3200 mm comprising 1400 x


C 4 Nr 0.00
2600 mm sliding double sash door, 35dB acoustic rated

Door panel with both sides finished in wood veneered (J-


407), consisting of double door and overhead fixed panel
including door frame, sub-framing, structural framing for
overhead panel, finishing, decorations (door hardware
measured separately), sealants, fixings and accessories as
detailed on Drawing 213-RD-ID-ZZZ-703 and all in
accordance with Specifications

Type D64, overall size 2000 x 3125 mm comprising 1900 x


D 1 Nr 0.00
2570 mm single swing double door, 35dB acoustic rated

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

DOORS (CONT'D)

Internal Doors (Cont'd)

Door panel with both sides finished in wood veneered (J-


407), consisting of single door and overhead fixed panel
including door frame, sub-framing, structural framing for
overhead panel, finishing, decorations (door hardware
measured separately), sealants, fixings and accessories as
detailed on Drawing 213-RD-ID-ZZZ-703 and all in
accordance with Specifications

Type D65, overall size 1060 x 2925 mm comprising 955 x


A 1 Nr 0.00
2580 mm single swing door, 45dB acoustic rated

Door panel in clear glass (J-500) consisting of single door


and fixed glass panels in both sides including satin brass (J-
900) finished door frame, sub-framing, structural framing for
overhead panel, finishing, decorations, door hardware,
sealants, fixings and accessories as detailed on Drawing
213-RD-ID-ZZZ-704

Type DG1, overall size 1600 x 2600 mm comprising 700 x


B 11 Nr 0.00
2600 mm single swing door

Type DG2, overall size 1600 x 2600 mm comprising 700 x


C 1 Nr 0.00
2600 mm single swing door

Mesh laminated glass (J-501) door including door frame,


sub-framing, finishing to Engineer's approval, decorations
(door hardware measured separately), sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-703

Type D62, single swing double doors overall size - 2000 x


D 1 Nr 0.00
3000 mm

Centre pivoted clear glass (J-500) panel door including satin


brass (J-900) finished door frames, sub-framing, finishing,
decorations, door hardware, sealants, fixings and
accessories as detailed on Drawing 213-RD-ID-ZZZ-704

E Type D66, pivot door, overall size 5035 x 2920 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

WINDOWS

Fixed Windows comprising 32 mm thick double glass and


ultra slim aluminium frames including sub frames,
architraves, transoms, stop, glazing, protective and
decorative coatings, finishes , ironmongery and all
necessary fixing accessories complete as show in drawings
213-RD-AR-ZZZ-710 and 711

A Type W01, overall size 6850 x 1850 mm 2 Nr 0.00

B Type W03a, overall size 900 x 2925 mm 10 Nr 0.00

C Type W03b, overall size 900 x 2925 mm 3 Nr 0.00

D Type W04, overall size 16850 x 3000 mm 2 Nr 0.00

E Type W05, overall size 2500 x 3000 mm 1 Nr 0.00

F Type W06, overall size 4345 x 3000 mm 1 Nr 0.00

G Type W07, overall size 900 x 2925 mm 2 Nr 0.00

H Type W08, overall size 27550 x 850 mm to light well 1 Nr 0.00

Awning Windows comprising 32mm thick double glass, ultra


slim aluminium frames including sub frames, architraves,
transoms, stop, glazing, protective and decorative coatings,
finishes, ironmongery and all necessary fixing accessories
complete as show in drawings 213-RD-AR-ZZZ-710 and
711

J Type W02a, overall size 4350 x 2700 mm 1 Nr 0.00

K Type W02b, overall size 2400 x 2700 mm 1 Nr 0.00

L Type W09a, overall size 1800 x 600 mm 3 Nr 0.00

M Type W09b, overall size 900 x 600 mm 1 Nr 0.00

N Type W09c, overall size 600 x 600 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

IRONMONGERY

Ironmongery sets including all necessary fixing accessories


complete all in accordance with 220812_LV48-Ironmongery
Schedule

A Type HW-001 6 Set 0.00

B Type HW-002 2 Set 0.00

C Type HW-003 3 Set 0.00

D Type HW-004 15 Set 0.00

E Type HW-005 4 Set 0.00

F Type HW-006 1 Set 0.00

G Type HW-007 6 Set 0.00

H Type HW-008 2 Set 0.00

J Type HW-009 1 Set 0.00

K Type HW-010 1 Set 0.00

L Type HW-011 1 Set 0.00

M Type HW-012 4 Set 0.00

N Type HW-013 1 Set 0.00

P Type HW-014 1 Set 0.00

Q Type HW-015 3 Set 0.00

R Type HW-016 1 Set 0.00

S Type HW-017 10 Set 0.00

T Type HW-018 1 Set 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

IRONMONGERY (CONT'D)

Ironmongery sets including all necessary fixing accessories


complete all in accordance with 220812_LV48-Ironmongery
Schedule (Cont'd)

A Type HW-019 1 Set 0.00

B Type HW-020 1 Set 0.00

C Type HW-021 1 Set 0.00

D Type HW-022 1 Set 0.00

E Type HW-023 1 Set 0.00

F Type HW-024 1 Set 0.00

G Hardware set to suit door type D56 2 Set 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

SKY LIGHT

Double glass skylight including primary and secondary


framing, fixings and accessories complete as detailed on
Drawings 213-RD-AR-ZZZ-425

A Overall size 3400 x 4000 mm wide 1 Nr 0.00

B Overall size 7935 x 2200 mm wide 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION H - DOORS AND WINDOWS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Page: 12


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION H -Page: 1 0.00

BILL 02/SECTION H -Page: 2 0.00

BILL 02/SECTION H -Page: 3 0.00

BILL 02/SECTION H -Page: 4 0.00

BILL 02/SECTION H -Page: 5 0.00

BILL 02/SECTION H -Page: 6 0.00

BILL 02/SECTION H -Page: 7 0.00

BILL 02/SECTION H -Page: 8 0.00

BILL 02/SECTION H -Page: 9 0.00

BILL 02/SECTION H -Page: 10 0.00

BILL 02/SECTION H -Page: 11 0.00

BILL 02/SECTION H -Page: 12 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION H -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES

BACKGROUNDS

Internal

Screeds; sand and cement screed for floor build-ups to


attain required levels in trowel finish complete all as detailed
on Drawings 213-RD-ID-ZZZ-540 to 213-RD-ID-ZZZ-542

A To receive carpet 94 m2 0.00

B To receive LVT flooring 54 m2 0.00

C To receive tiles 348 m2 0.00

D To receive epoxy paint 485 m2 0.00

E To receive stone flooring 691 m2 0.00

F To receive stone flooring 472 m2 0.00

Cement and sand render finish on concrete /masonry walls


including beads, trims and accessories complete

G To receive tiles 609 m2 0.00

H To receive paint 948 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

BACKGROUNDS (CONT'D)

External

Screeds; sand and cement screed for floor build-ups to


attain required levels in trowel finish complete

A To receive tiles 472 m2 0.00

Cement and sand render finish on concrete /masonry walls


including beads, trims and accessories complete

B To receive paint finish, inner side of parapet walls 87 m2 0.00

C Extra over 30 mm grooves 21 m 0.00

To receive paint finish, parapet coping - width not exceeding


D 101 m2 0.00
300 mm

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES

Floor Finishes

Inset carpet in wool and viscose handloom, soft medium pile


finish, laid on cement screed (screed measured separately)
including underlays, WBP plyboard backings, adhesive,
recommended treatments, acoustic treatment where
required, edging strips, trims and accessories complete as
per Manufacturer's recommendation and as Detail 3 on
Drawing 213-RD-ID-ZZZ-540 (F-101)

A Living room 59 m2 0.00

B Cinema 13 m2 0.00

Inset carpet in wool and viscose handloom, soft medium pile


finish, laid on raised floor system including underlays, WBP
plyboard, primary and secondary framing structure,
adhesive, recommended treatments, acoustic treatment
where required, edging strips, trims and accessories
complete as per Manufacturer's recommendation and as
Detail 19 on Drawing 213-RD-ID-ZZZ-542 (F-101)

C Cinema 21 m2 0.00

D 125 mm high risers to Cinema 4 m 0.00

E 250 mm high risers to Cinema 7 m 0.00

LVT flooring in natural pore finish, laid to pattern on cement


screed (screed measured separately) including underlays,
floor leveler, primers and treatments, trims and accessories
complete as per Manufacturer's recommendation (F-102)

F Gym 37 m2 0.00

LVT flooring; 470 x 610 mm size in matte finish, laid to


staggered pattern on cement screed (screed measured
separately) including underlays, floor leveler, primers and
treatments, trims and accessories complete as per
Manufacturer's recommendation (F-103)

G Kids playroom 18 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Floor Finishes (Cont'd)

Marble flooring in off white colour, polished soft matte look


finish, laid to pattern on cement screed (screed measured
separately) including adhesive, acoustic underlay, colour
matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (F-300)

General areas (Circulation, Dinning, Store, Lobbies,


A 613 m2 0.00
Vestibule, Foyer)

Marble flooring in off white colour, polished soft matte look


finish, laid to pattern on cement screed (screed measured
separately) including metal strip (J-900), adhesive, acoustic
underlay, colour matched grouting, sealers, sealants, trims,
fixings and accessories complete as per Manufacturer's
recommendation and as detail on Drawing 213-RD-ID-ZZZ-
562 (F-300)

B To stair landings 22 m2 0.00

C To under side of stair 2 landings 4 m2 0.00

D 175 mm risers 120 m 0.00

E 300 mm treads 96 m 0.00

F 175 mm under side of stair 2 risers 61 m 0.00

G 300 mm under side of stair 2 treads 60 m 0.00

H 430 mm wide stair 2 stringers 35 m 0.00

Marble - cappucino flooring in brown colour, polished finish,


laid to pattern on cement screed (screed measured
separately) including adhesive, underlay, colour matched
grouting, sealers, sealants, trims, fixings and accessories
complete as per Manufacturer's recommendation (F-302)

J Stair 2 floor plinth 7 m2 0.00

K 172 mm risers 12 m 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Floor Finishes (Cont'd)

Marble - onyx in polished finish, laid to pattern on cement


screed (screed measured separately) including adhesive,
acoustic underlay, colour matched grouting, sealers,
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (F-303)

A Pooja room 7 m2 0.00

B 450 mm high risers to Pooja room 3 m2 0.00

Dekton tile, 1420 x 1590 mm in Suede antislip finish with


suitble R rating, laid to pattern on cement screed (screed
measured separately) including adhesive, acoustic underlay,
colour matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (F-304)

C Kitchen, Pot wash/ Store, Pantry and Utility 37 m2 0.00

Marble flooring with decorative pearl inlay in polished soft


matte look finish, laid to pattern on cement screed (screed
measured separately) including adhesive, acoustic underlay,
colour matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (F-300/ F-305)

D Central courtyard 60 m2 0.00

E 100 mm high risers to Central courtyard 28 m 0.00

F 60 x 100 mm high steps to Central Courtyard 30 m 0.00

Floor tile; 1200 x 2780 mm in soft R9 finish, laid to pattern


on cement screed (screed measured separately) including
adhesive, acoustic underlay, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-307)

G Guest bathroom 23 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Floor Finishes (Cont'd)

Floor tile; 900 x 1800 x 10 mm thick in natural R9 finish, laid


to pattern on cement screed (screed measured separately)
including adhesive, acoustic underlay, colour matched
grouting, sealers, sealants, trims, fixings and accessories
complete as per Manufacturer's recommendation (F-310)

A Master Bathrooms, Ground floor Washrooms and SPA 103 m2 0.00

Floor tile; 2700 x 1200 mm thick in matt finish, laid to pattern


on cement screed (screed measured separately) including
adhesive, acoustic underlay, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-313)

B Nursery bathroom and Kid's Bathrooms 26 m2 0.00

Floor tile; 600 x 600 mm thick in matt finish, laid to pattern


on cement screed (screed measured separately) including
adhesive, acoustic underlay, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-315)

C Laundry, Server and Storage room 32 m2 0.00

Floor tile; 600 x 1200 mm in polished finish, laid to pattern on


cement screed (screed measured separately) including
adhesive, acoustic underlay, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-316)

D Staff rooms 69 m2 0.00

Floor tile; 800 x 800 mm in matte finish, laid to pattern on


cement screed (screed measured separately) including
adhesive, acoustic underlay, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-318)

E Staff bathrooms 17 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Floor Finishes (Cont'd)

Floor tile; 1400 x 2500 x 20 mm thick in honed finish, laid to


pattern on cement screed (screed measured separately)
including adhesive, acoustic underlay, colour matched
grouting, sealers, sealants, trims, fixings and accessories
complete as per Manufacturer's recommendation (F-320)

A Wine cellar 43 m2 0.00

Wood flooring with planks size (1700 - 2200) x (180 - 200)


mm, laid to pattern on cement screed (screed measured
separately) including timber floor inlay, adhesive, primers
and treatments, finishing, decorations, trims and accessories
complete as per Manufacturer's recommendation (F-400)

B Master bedroom, Guest bedroom, Linet closets 308 m2 0.00

Herringbone wood flooring with super ready parquet 90 mm


wide planks, laid to pattern on cement screed (screed
measured separately) including timber floor inlay, adhesive,
primers and treatments, finishing, decorations, trims and
accessories complete as per Manufacturer's
recommendation (F-401)

C Nursery and Kids bedroom 95 m2 0.00

Wood flooring with planks size (1700 - 2200) x (180 - 200)


mm, laid to pattern on cement screed (screed measured
separately) including timber floor inlay, adhesive, primers
and treatments, finishing, decorations, trims and accessories
complete as per Manufacturer's recommendation (F-402)

D Office 32 m2 0.00

Weaved wood parquet flooring, laid to pattern on cement


screed (screed measured separately) including timber floor
inlay, adhesive, primers and treatments, finishing,
decorations, trims and accessories complete as per
Manufacturer's recommendation (F-403)

E Wine lounge 39 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Floor Finishes (Cont'd)

Brown smoked glass in opaque, toughened/tempered finish,


fixed on cement screed (screed measured separately)
including underlays, perimeter extruded silicone cushion,
sealant, trims and accessories complete as per
Manufacturer's recommendation (F-502)

A Staircase upstand base 8 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Skirting

MDF skirting to receive paint finish (measured separately),


including adhesive, trims and accessories complete as
detailed on Drawings 213-RD-ID-ZZZ-541

A 100 mm high 507 m 0.00

Metal skirting including finishes, adhesive, trims and


accessories complete as detailed on Drawings 213-RD-ID-
ZZZ-542/ 22

B 50 mm high to Wine cellar 11 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Wall Finishes

Travertine marble in filled and polished finish fixed to pattern


including adhesive, colour matched grouting, sealers,
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-301)

General areas (Foyer, Lobby, Corridors, Living room, Dining


A 376 m2 0.00
area, Master bedroom and Common Washroom)

Onyx marble in polished finish fixed to pattern including


adhesive, colour matched grouting, sealers, sealants, trims,
fixings and accessories complete as per Manufacturer's
recommendation (W-303)

B Pooja room 40 m2 0.00

Wall tile; 3000 x 1500 x 6 mm thick in shiny finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-306)

C Guest bathroom 51 m2 0.00

Wall tile; 1200 x 2780 mm size in lappato finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-308)

D Guest bathroom 43 m2 0.00

Wall tile; 1200 x 2780 x 6.5 mm thick in vein cut - fully


lappato finish fixed to pattern including adhesive, colour
matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (W-309)

E Sauna, WC and Shower area in SPA and Master bathroom 208 m2 0.00

Wall tile; 1200 x 2400 x 6 mm thick in lucida finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-310-B)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Wall Finishes (Cont'd)

Wall tile; 1200 x 2400 x 6 mm thick in lucida finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-310-B)

A Washroom 48 m2 0.00

Wall tile; 600 x 1200 x 9.5 mm thick in natural finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-311)

B Master bathroom 28 m2 0.00

Wall tile; 1200 x 2700 mm size in matt finish fixed to pattern


including adhesive, colour matched grouting, sealers,
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-313)

C Nursery and Kid's bathroom 33 m2 0.00

Wall tile; 50 x 250 x 9 mm thick in glossy finsih fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-314)

D Nursery and Kid's bathroom 79 m2 0.00

Wall tiles in suede finish fixed to pattern including adhesive,


colour matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (W-317)

E Kid's bedroom 57 m2 0.00

Wall tile; 800 x 800 mm size matte finsih fixed to pattern


including adhesive, colour matched grouting, sealers,
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-318)

F Staff bathroom 67 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Wall Finishes (Cont'd)

Marble; 3000 x 1500 x 6 mm thick in polished finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-323)

A Office 10 m2 0.00

Marble; 3000 x 1500 x 6 mm thick in polished finish fixed to


pattern including adhesive, colour matched grouting, sealers
sealants, trims, fixings and accessories complete as per
Manufacturer's recommendation (W-324)

B Gym 8 m2 0.00

Himalaya stone fixed to pattern including adhesive, colour


matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation

C Kitchen (By specialist) 7 m2 0.00

Wood veneered cladding panels including substrate,


secondary framing and supports, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (W-404)

D Office and Gym 54 m2 0.00

Wood veneered cladding panels including substrate,


secondary framing and supports, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (W-407)

E Guest bedroom 13 m2 0.00

Wallpaper in nelson pattern including MDF substrate, timber


batten/ aluminium clips secondary framing, adhesive, trims
and accessories complete as per Manufacturer's
recommendation (W-801)

F Office 48 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 12


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

INTERNAL FINISHES (CONT'D)

Wall Finishes (Cont'd)

Wallpaper including MDF substrate, timber batten/


aluminium clips secondary framing, adhesive, trims and
accessories complete as per Manufacturer's
recommendation (W-803)

A Kid's playroom 20 m2 0.00

Fabric wall in suede finish including MDF substrate, timber


batten/ aluminium clips secondary framing, acoustic
treatment where required, adhesive, trims, fittings, fixings
and accessories complete as per Manufacturer's
recommendation and as Detail 7 on Drawing 213-RD-ID-
ZZZ-521 (W-810)

B Cinema 76 m2 0.00

C Extra over for forming 1840 x 2625 mm high hidden door 1 Nr 0.00

Wallpaper in tela pattern including MDF substrate, timber


batten/ aluminium clips secondary framing, adhesive, trims
and accessories complete as per Manufacturer's
recommendation (W-812)

D Golf simulator 26 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 13


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

EXTERNAL FINISHES

Floor Finishes

Outdoor porcelain tiles; 600 x 1200 mm size in natural finish


laid to pattern on cement screed (screed measured
separately) including bedding, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (F-301-E)

A Balconies 27 m2 0.00

B Roof terrace 445 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 14


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

EXTERNAL FINISHES (CONT'D)

Wall Finishes

Travertino navona stone cladding; cut to size in natural


colour, suede finish, mechanically fixed, including framing,
subframing, trims, anchors, adhesives, fasteners, and
sealants, fixing and accessories complete as per
Manufacturer's recommendation (W-300-E)

A To external walls 77 m2 0.00

Fibre cement board; water resistant construction board


directly fixed on insulated block wall to receive decorations
(measured separately), including trims, adhesives,
fasteners, any primers or treatments, fixing and accessories
complete

B To external walls 732 m2 0.00

Fibre cement board moulding; water resistant construction


board to receive decorations (measured separately),
including framing, subframing, trims, adhesives, fasteners,
any primers or treatments, fixing and accessories complete

C Overall size 150 x 450 mm high plinth to external walls 99 m 0.00

Overall size 150 x 840 mm high plinth/ moulding to external


D 28 m 0.00
walls

E Overall size 150 x 925 mm high moulding to external walls 62 m 0.00

F Overall size 150 x 950 mm high moulding to external walls 84 m 0.00

G Overall size 180 x 925 mm high moulding to external walls 13 m 0.00

H Overall size 240 x 950 mm high moulding to external walls 8 m 0.00

J Overall size 250 x 925 mm high moulding to external walls 18 m 0.00

K Overall size 305 x 950 mm high moulding to external walls 3 m 0.00

L Overall size 310 x 925 mm high moulding to external walls 3 m 0.00

M Overall size 310 x 950 mm high moulding to external walls 3 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 15


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

EXTERNAL FINISHES (CONT'D)

Wall Finishes (Cont'd)

Fibre cement board moulding; water resistant construction


board to receive decorations (measured separately),
including framing, subframing, trims, adhesives, fasteners,
any primers or treatments, fixing and accessories complete
(Cont'd)

A Overall size 315 x 925 mm high moulding to external walls 3 m 0.00

B Overall size 315 x 950 mm high moulding to external walls 3 m 0.00

C Overall size 500 x 925 mm high moulding to external walls 29 m 0.00

D Overall size 500 x 950 mm high moulding to external walls 30 m 0.00

E Overall size 1100 x 950 mm high moulding to external walls 82 m 0.00

F Extra over forming gutter, 410 x 200 mm depth 40 m 0.00

Glass fibre reinforced concrete infill panel including finishes


decorations, stiffeners, ties, joints, head restraint, anchors,
reinforcement, metal lathing, fixing and accessories
complete as detailed on Drawing 213-RD-AR-ZZZ-720
(F01)

G Overall size 900 x 2100 mm high 12 No. 0.00

Customized GRP blocks; 300 x 300 x 75 mm thick blocks in


colour to match W201-E in natural finish, including metal
support where required, stiffeners, ties, joints, head restraint,
anchors, reinforcement, metal lathing, any primer or
protective treatment, fixing and accessories complete as
detailed on Drawing 213-RD-AR-ZZZ-405 (W600-E)

H To external walls 55 m2 0.00

J To entrance canopy 117 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 16


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

LIFT CAB FINISHES

Floor Finishes

Marble flooring in off white colour, polished soft matte look


finish, laid to pattern on cement screed (screed measured
separately) including adhesive, acoustic underlay, colour
matched grouting, sealers, sealants, trims, fixings and
accessories complete as per Manufacturer's
recommendation (F-300)

A To floor 3 m2 0.00

Satin brass metal trim to floor including concealed fixings


and accessories as per Manufacturer's recommendation
and as detailed on Drawings 213-RD-ID-ZZZ-570 (F-900)

B To floor 5 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 17


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

LIFT CAB FINISHES (CONT'D)

Wall Finishes

Marble in off white colour, polished soft matte look finish, laid
to pattern including adhesive, colour matched grouting,
sealers, sealants, trims, fixings and accessories complete as
per Manufacturer's recommendation (J-300)

A To walls 3 m2 0.00

14 mm thick mesh laminated glass panel (J-501) with satin


brass (J-900) finished inserts/ trims including substrate,
secondary framing and supports, fixings and accessories
complete as per Manufacturer's recommendation

B To walls 4 m2 0.00

Metal wall cladding in satin brass finish fixed including


substrate, secondary framing and supports, fixings and
accessories complete as per Manufacturer's
recommendation (J-900)

C To walls 6 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 18


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

LIFT CAB FINISHES (CONT'D)

Ceiling Finishes

Decorative ceiling in textured paint in satin finish applied to


Manufacturer's recommendation including ceiling boards /
panels including backing materials as required, fire, acoustic
and smoke assemblies, trims, joint treatments, auxiliary
materials, fixings and accessories complete as per
manufacturer's recommendation (C-202)

A to gypsum board ceilings - lift car 3 m2 0.00

B 100 x 50 mm high size light cove 5 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 19


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

LIFT CAB FINISHES (CONT'D)

Accessories

Wall mounted metal handrail in satin brass finish including


metal support frame, brackets, cover plates, fittings, fixings
and necessary accessories complete as per Manufacturer's
recommendation (J-900)

A To walls 1 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 20


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS

Suspended ceilings have been measured over all lighting


fittings and ceiling grilles etc., with no deduction made,
irrespective of the size of the opening. The rates are to
include for the cost of all curved or straight perimeter
A Note
edgings and trims fixed either to the ceiling or the structure,
forming access panels as required, trimming to light fittings,
speakers, grilles and the like including additional support
framing and hangers.

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 21


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

Internal

Wood veneered ceiling comprising 50 x 200 mm high timber


beams in natural satin finish, including fixed metal studs to
the slab, suspension system, support framing, shadow gaps,
trims and all necessary fixing accessories complete as per
Manufacturer's recommendation and as Detail 10 on
Drawings 213-RD-ID-ZZZ-501 (C-404)

A To ceilings, suspension depth not exceeding 0.50 meter 30 m2 0.00

B 200 mm high bulkhead 25 m 0.00

Wood veneered ceiling comprising 40 x 40 mm high timber


battens in natural satin finish, including fixed metal studs to
the slab, suspension system, support framing, shadow gaps,
trims and all necessary fixing accessories complete as per
Manufacturer's recommendation and as Detail 16 on
Drawings 213-RD-ID-ZZZ-501 (C-407)

C To ceilings, suspension depth of 0.50 to 1.00 meter 77 m2 0.00

Wood veneered ceiling in natural satin finish, including fixed


metal studs to the slab, suspension system, support
framing, shadow gaps, trims and all necessary fixing
accessories complete as per Manufacturer's
recommendation and as Detail 15 on Drawings 213-RD-ID-
ZZZ 501 (C 407)

D To ceilings, suspension depth of 0.50 to 1.00 meter 23 m2 0.00

E Extra over for MDF support panel 5 m2 0.00

F 200 mm high bulkhead 18 m 0.00

G 100 x 50 mm high light cove 18 m 0.00

Wood veneered ceiling in natural satin finish, including fixed


metal studs to the slab, suspension system, support
framing, shadow gaps, trims and all necessary fixing
accessories complete as per Manufacturer's
recommendation and as Detail 13 on Drawings 213-RD-ID-
ZZZ 501 (C 407)

H To ceilings, suspension depth of 0.50 to 1.00 meter 7 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 22


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

Internal (Cont'd)

Wood veneered ceiling in natural satin finish, including fixed


metal studs to the slab, suspension system, support
framing, shadow gaps, trims and all necessary fixing
accessories complete as per Manufacturer's
recommendation and as Detail 13 on Drawings 213-RD-ID-

A 100 mm high bulkhead 10 m 0.00

B 150 mm high bulkhead 11 m 0.00

C 150 x 50 mm high light cove 10 m 0.00

6 mm thick bronzed color beveled edge mirror including


fixed metal studs to the slab, adhesive, backing panel, MDF
reinforcement, shadow gaps, trims and all necessary fixing
accessories complete as per Manufacturer's
recommendation and as Detail 13 on Drawings 213-RD-ID-
ZZZ-501 (C-504)

D To ceilings, suspension depth of 0.50 to 1.00 meter 9 m2 0.00

Translucent fabric sirius ceiling, including shadow gaps,


intermediate fixing profiles,12 mm grooves, trims, angles, all
necessary fixing accessories complete as per
Manufacturer's recommendation and as detailed on Drawing
213-RD-ID-ZZZ-503 (C-601)

E Stretch ceiling (By specialist) 56 m2 0.00

F 10mm thick white painted MDF panel, 150 mm high 18 m 0.00

12.5 mm thick gypsum board ceiling with tapped and filled


joints to receive paint finishes (measured separately),
including fixed metal studs to the slab, suspention system,
shadow gaps, trims, all necessary fixing accessories
complete as per Manufacturer's recommendation and as
detailed on Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-
ZZZ-503 (C-602)

G To ceilings, suspension depth of 0.50 to 1.00 meter 427 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 23


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

Internal (Cont'd)

12.5 mm thick gypsum board ceiling with tapped and filled


joints to receive paint finishes (measured separately),
including fixed metal studs to the slab, suspention system,
shadow gaps, trims, all necessary fixing accessories
complete as per Manufacturer's recommendation and as
detailed on Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-
ZZZ-503 (C-602) (Cont'd)

A 150 mm high bulkhead 22 m 0.00

B 350 mm high bulkhead 13 m 0.00

Metal cladded ceilings in satin brass finish including fixed


metal studs to the slab, support framing, suspension
system, shadow gaps, trims and all necessary fixing
accessories complete as per Manufacturer's
recommendation and as detailed on Drawings 213-RD-ID-
ZZZ-500 to 213-RD-ID-ZZZ-502 (C-900)

C To ceilings, suspension depth of 0.50 to 1.00 meter 21 m2 0.00

Flush plasterboard ceiling with tapped and filled joints to


receive paint finishes (measured separately), including fixed
metal studs to the slab, suspension system, shadow gaps,
trims and all necessary fixing accessories complete as
detailed on Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-
ZZZ-502

D To ceilings, suspension depth not exceeding 0.50 meter 204 m2 0.00

E Extra over for MDF support panel 171 m2 0.00

F To ceilings, suspension depth of 0.50 to 1.00 meter 1,102 m2 0.00

G Extra over for MDF support panel 31 m2 0.00

Extra over for allowing provision for flip down ceiling mounted
H 3 Nr 0.00
TV

J Extra over for forming recesse for LED strip light 10 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 24


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

Internal (Cont'd)

Flush plasterboard ceiling with tapped and filled joints to


receive paint finishes (measured separately), including fixed
metal studs to the slab, suspension system, shadow gaps,
trims and all necessary fixing accessories complete as
detailed on Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-
ZZZ-502 (Cont'd)

A 150 mm high bulkhead 25 m 0.00

B 200 mm high bulkhead 786 m 0.00

C 700 mm high bulkhead to staircase 2 skylight 19 m 0.00

D 900 mm high bulkhead to skylight 14 m 0.00

E 100 x 50 mm high light cove 490 m 0.00

F 100 x 75 mm high light cove 91 m 0.00

G 150 x 50 mm high light cove 67 m 0.00

Flush plasterboard ceiling with tapped and filled joints to


receive paint finishes (measured separately), including fixed
metal studs to the slab, suspension system, acoustic
treatments where required, shadow gaps, trims and all
necessary fixing accessories complete as detailed on
Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-ZZZ-502

H To ceilings, suspension depth not exceeding 0.50 meter 12 m2 0.00

J To ceilings, suspension depth of 0.50 to 1.00 meter 26 m2 0.00

K 100 x 100 mm high light cove 17 m 0.00

Moisture resistant flush plasterboard ceiling with tapped and


filled joints to receive paint finishes (measured separately),
including fixed metal studs to the slab, shadow gaps, trims
and all necessary fixing accessories complete as detailed on
Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-ZZZ-502

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 25


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

Internal (Cont'd)

Moisture resistant flush plasterboard ceiling with tapped and


filled joints to receive paint finishes (measured separately),
including fixed metal studs to the slab, shadow gaps, trims
and all necessary fixing accessories complete as detailed on
Drawings 213-RD-ID-ZZZ-500 to 213-RD-ID-ZZZ-502

A To ceilings, suspension depth not exceeding 0.50 meter 19 m2 0.00

B Extra over for MDF support panel 11 m2 0.00

C To ceilings, suspension depth of 0.50 to 1.00 meter 229 m2 0.00

D Extra over for MDF support panel 35 m2 0.00

E 200 mm high bulkhead 193 m 0.00

F 100 x 50 mm high light cove 99 m 0.00

Coved MDF ceiling to receive paint finishes (measured


separately), including fixed metal studs to the slab, shadow
gaps, trims, all necessary fixing accessories complete as
Detail 12 on Drawings 213-RD-ID-ZZZ-501

To coved ceilings, suspension depth not exceeding 0.50


G 7 m2 0.00
meter, to Spa (measured flat on plan)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 26


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

SUSPENDED CEILINGS (CONT'D)

External

Fibre cement board ceiling, water resistant construction


board to receive decorations (measured separately),
including fixed metal studs to the slab, trims, adhesives,
fasteners, any primers or treatments, fixing and accessories
complete

A To ceilings, suspension depth of 0.50 to 1.00 meter 28 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 27


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

DECORATIONS

Internal

Anti-slip, chemical, abrasion and water resistant epoxy paint


in satin finish on cement sand screed (measured
separately), including primers, treatments, base coats and
undercoats complete as per Manufacturer's
recommendation (F 600)

A To carpark, ramp and pump room 485 m2 0.00

B 50 mm high risers 2 m 0.00

Floor sealer, including primers, treatments, base coats and


undercoats complete as per Manufacturer's
recommendation

C To golf simulator room (to receive finishes by specialist) 20 m2 0.00

Textured paint in satin finish including necessary substate


leveler, primers, treatments, base coats and undercoats
complete as per Manufacturer's recommendation (W-200/ C-
200)

D To walls 555 m2 0.00

E To walls; wet area 31 m2 0.00

F To plasterboard ceilings 53 m2 0.00

Textured paint in satin finish including necessary substate


leveler, primers, treatments, base coats and undercoats
complete as per Manufacturer's recommendation (W-201)

G To walls 361 m2 0.00

Textured paint in satin finish including necessary substate


leveler, primers, treatments, base coats and undercoats
complete as per Manufacturer's recommendation (C-202)

H To plasterboard ceilings 415 m2 0.00

Moisture resistant paint in satin finish, including primers,


treatments, base coats and undercoats complete as per
Manufacturer's recommendation (C-203)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 28


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

DECORATIONS (CONT'D)

Internal (Cont'd)

Moisture resistant paint in satin finish, including primers,


treatments, base coats and undercoats complete as per
Manufacturer's recommendation (C-203)

A To plasterboard ceilings 331 m2 0.00

Textured paint in marmorino white finish including necessary


substate leveler, primers, treatments, base coats and
undercoats complete as per Manufacturer's
recommendation (W-204)

B To walls 82 m2 0.00

Decorative paint in concrete effect finish including primers,


treatments, base coats and undercoats complete as per
Manufacturer's recommendation (W-206)

C To walls 4 m2 0.00

Textured paint in monocouche finish including necessary


substate leveler, primers, treatments, base coats and
undercoats complete as per Manufacturer's
recommendation (W-208/ C-208)

D To walls 51 m2 0.00

E To plasterboard ceilings 37 m2 0.00

F To MDF coved ceilings (measured flat on plan) 7 m2 0.00

Paint in matte finish including primers, treatments, base


coats and undercoats complete as per Manufacturer's
recommendation (C-210)

G To plasterboard ceilings 37 m2 0.00

Paint in satin finish including primers, treatments, base coats


and undercoats complete as per Manufacturer's
recommendation (W-211/ C-211)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 29


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

DECORATIONS (CONT'D)

Internal (Cont'd)

Paint in satin finish including primers, treatments, base coats


and undercoats complete as per Manufacturer's
recommendation (W-211/ C-211)

A To walls 368 m2 0.00

B To walls; wet area 20 m2 0.00

C To plasterboard ceilings 250 m2 0.00

D To slab soffits 48 m2 0.00

E To sloping soffit of stairs 11 m2 0.00

Paint in satin finish including primers, treatments, base coats


and undercoats complete as per Manufacturer's
recommendation (W-212)

F To walls 27 m2 0.00

Paint in satin finish including primers, treatments, base coats


and undercoats complete as per Manufacturer's
recommendation (W-213/ C-213)

G To walls 299 m2 0.00

H To gypsum board ceilings 65 m2 0.00

Paint in 10% gloss finish including primers, treatments, base


coats and undercoats complete as per Manufacturer's
recommendation (C-215)

J To plasterboard ceilings 769 m2 0.00

K To slab soffits 25 m2 0.00

Paint finish including primers, treatments, base coats and


undercoats complete

L To walls in light well 232 m2 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 30


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

DECORATIONS (CONT'D)

Internal (Cont'd)

Paint finish including primers, treatments, base coats and


undercoats complete (Cont'd)

A To plasterboard ceilings 372 m2 0.00

Paint finish, white colour including primers, treatments, base


coats and undercoats complete

B To plasterboard ceilings 56 m2 0.00

Paint finish including primers, treatments, base coats and


undercoats complete as detailed on Drawing 213-RD-ID-
ZZZ-541

C To 100mm high MDF skirting 507 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 31


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

DECORATIONS (CONT'D)

External

Exterior textured paint in silk finish, including necessary


substrate leveler, primers, treatments, base coats and
undercoats complete as per Manufacturer's
recommendation (W-200-E)

A To FC sheet cladded mouldings 603 m2 0.00

B To FC sheet cladded soffits 28 m2 0.00

C To ramp walls 224 m2 0.00

Exterior paint in silk finish applied, including primers,


treatments, base coats and undercoats complete as per
Manufacturer's recommendation (W-201-E)

D To FC sheet cladded plinth/ mouldings 91 m2 0.00

E To FC sheet cladded walls 732 m2 0.00

F To plastered parapet walls 87 m2 0.00

G To plastered parapet coping, width not exceeding 300mm 101 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 32


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION J - FINISHES (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Page: 33


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION J -Page: 1 0.00

BILL 02/SECTION J -Page: 2 0.00

BILL 02/SECTION J -Page: 3 0.00

BILL 02/SECTION J -Page: 4 0.00

BILL 02/SECTION J -Page: 5 0.00

BILL 02/SECTION J -Page: 6 0.00

BILL 02/SECTION J -Page: 7 0.00

BILL 02/SECTION J -Page: 8 0.00

BILL 02/SECTION J -Page: 9 0.00

BILL 02/SECTION J -Page: 10 0.00

BILL 02/SECTION J -Page: 11 0.00

BILL 02/SECTION J -Page: 12 0.00

BILL 02/SECTION J -Page: 13 0.00

BILL 02/SECTION J -Page: 14 0.00

BILL 02/SECTION J -Page: 15 0.00

BILL 02/SECTION J -Page: 16 0.00

BILL 02/SECTION J -Page: 17 0.00

BILL 02/SECTION J -Page: 18 0.00

BILL 02/SECTION J -Page: 19 0.00

BILL 02/SECTION J -Page: 20 0.00

BILL 02/SECTION J -Page: 21 0.00

Carried To Next Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION (CONT'D)

Total Brought Forward from Page No. (Cont'd) 0.00

BILL 02/SECTION J -Page: 22 0.00

BILL 02/SECTION J -Page: 23 0.00

BILL 02/SECTION J -Page: 24 0.00

BILL 02/SECTION J -Page: 25 0.00

BILL 02/SECTION J -Page: 26 0.00

BILL 02/SECTION J -Page: 27 0.00

BILL 02/SECTION J -Page: 28 0.00

BILL 02/SECTION J -Page: 29 0.00

BILL 02/SECTION J -Page: 30 0.00

BILL 02/SECTION J -Page: 31 0.00

BILL 02/SECTION J -Page: 32 0.00

BILL 02/SECTION J -Page: 33 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION J -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES

GENERALLY

Mirror

6 mm thick bevelled edge square shaped mirror in antifog


finish including framing, sub framing, backing panels,
adhesive, trims and all necessary fixing accessories
complete (W-503)

A Overall size 780 x 1200 mm 3 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

GENERALLY (CONT'D)

Sanitary Fittings

Sanitary fittings including all necessary fittings, fixing and


accessories complete all in accordance with
220812_LV48_Sanitaryware Schedule

A Type SW01, Basin mixer 5 Nr 0.00

B Type SW02, WC wall hung 12 Nr 0.00

C Type SW03, Flush plate 12 Nr 0.00

D Type SW03B, Flush plate 3 Nr 0.00

E Type SW04, Hydro brush with connection 9 Nr 0.00

Type SW12, Wall-mounted thermostatic high-capacity mixer


F 5 Nr 0.00
with built-in unit

G Type SW13, Hand shower set 8 Nr 0.00

H Type SW14, Body jets 10 Nr 0.00

J Type SW15, Rain shower system 5 Nr 0.00

K Type SW18, Shower mixer 3 way diverted built in parts 2 Nr 0.00

Type SW19, Showerhead wall mounted with rain/waterfall


L 2 Nr 0.00
feature

M Type SW20, Mixer high spout with control 2 Nr 0.00

N Type SW21, Freestanding basin 2 Nr 0.00

Type SW22, Mixer wall mounted spout with separate mixer


P 2 Nr 0.00
and built in parts

Q Type SW23, Bathtub feestanding 1 Nr 0.00

Type SW24, Bath mixer freestanding with built in part for


R 1 Nr 0.00
standing mixer

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

GENERALLY (CONT'D)

Sanitary Fittings (Cont'd)

Sanitary fittings including all necessary fittings, fixing and


accessories complete all in accordance with
220812_LV48_Sanitaryware Schedule (Cont'd)

A Type SW26, Mixer freestanding with built in parts 3 Nr 0.00

B Type SW27, Freestanding basin 3 Nr 0.00

C Type SW28, Mixer with separate control and built in parts 3 Nr 0.00

D Type SW29, Hydrobrush with connection 3 Nr 0.00

E Type SW33, Bath mixer with diverter deck mounted 1 Nr 0.00

F Type SW34, Shower mixer built in parts 1 Nr 0.00

G Type SW35, Showerhead wall mounted 1 Nr 0.00

Type SW41, Thermostatic mixer with shower head and


H 2 Nr 0.00
automatic diverter

J Type SW42, Basin countertop mounted 3 Nr 0.00

K Type SW45, 2 Hole concealed basin mixer 3 Nr 0.00

L Type SW46, Basin wall hung 3 Nr 0.00

M Type SW47, Water closets 3 Nr 0.00

N Type SW48, Hydrospray kit 3 Nr 0.00

P Type SW51, Shower column with mixer and hand shower 3 Nr 0.00

Q Type SW53, Inset sink 1 Nr 0.00

R Type SW54, Mixer with swivel spout 1 Nr 0.00

S Type SW55, Bar mixer 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

GENERALLY (CONT'D)

Sanitary Fittings (Cont'd)

Sanitary fittings including all necessary fittings, fixing and


accessories complete all in accordance with
220812_LV48_Sanitaryware Schedule (Cont'd)

A Type SW56, Sink 1 Nr 0.00

B Type SW57, Mixer with spout 1 Nr 0.00

C Type SW60, Bottle trap 7 Nr 0.00

D Type SW61, Bottle trap 3 Nr 0.00

E Type SW62, Bottle trap 3 Nr 0.00

F Type SW63, Framed concealed cistern for wall hung WC 15 Nr 0.00

G Type SW64, Inset tub 1 Nr 0.00

H Type SW65, Kitchen sink 1 2 Nr 0.00

J Type SW66, Kitchen sink 2 double square undermount 1 Nr 0.00

K Type SW67, Kitchen sink mixer 2 Nr 0.00

L Type SW68, Kitchen sink 1 pot wash 1 Nr 0.00

M Type SW69, Kitchen sink 2 double square pot wash 1 Nr 0.00

N Type SW70, Kitchen sink mixer pot wash 2 Nr 0.00

P Type SW71, Kitchen sink mixer 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

GENERALLY (CONT'D)

Sanitary Accessories

Sanitary accessories including all necessary fixing and


accessories complete all in accordance with
220812_LV48_Sanitaryware Schedule

A Type SW05, Toilet roll holder 8 Nr 0.00

B Type SW06, Floor drain with tile insert 20 Nr 0.00

C Type SW07, Brush holder 8 Nr 0.00

D Type SW08, Waste bin 9 Nr 0.00

E Type SW09, Wall-mounted robe hook 13 Nr 0.00

F Type SW10, Towel rail 600 mm long 7 Nr 0.00

G Type SW11, Towel rail 300 mm long 5 Nr 0.00

Type SW16, Shower drain linear channel cover with tile


H 7 Nr 0.00
insert 792 mm long

J Type SW17, Towel holder floor standing 2 Nr 0.00

K Type SW25, Towel rail ceiling mounted 1 Nr 0.00

L Type SW30, Toilet roll holder 4 Nr 0.00

M Type SW31, Brush holder wall mounted 2 Nr 0.00

N Type SW32, Waste paper bin 3 Nr 0.00

P Type SW36, Towel rail 460 mm long 5 Nr 0.00

Q Type SW37, Robe hook 5 Nr 0.00

R Type SW38A, Soap holder 4 Nr 0.00

S Type SW39, Floor drain with tile insert 6 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

GENERALLY (CONT'D)

Sanitary Accessories (Cont'd)

Sanitary accessories including all necessary fixing and


accessories complete all in accordance with
220812_LV48_Sanitaryware Schedule (Cont'd)

Type SW40, Shower drain linear channel cover with tile


A 2 Nr 0.00
insert 796 mm long

B Type SW43, Soap and shampoo dispenser 3 Nr 0.00

C Type SW44, Towel ring 2 Nr 0.00

D Type SW49, Toilet roll holder with cover 3 Nr 0.00

E Type SW50, Floor drain with cover 4 Nr 0.00

F Type SW52, Soap shelf 6 Nr 0.00

G Type SW58, Towel rod 600 mm long 3 Nr 0.00

H Type SW59, Shower drain 3 Nr 0.00

J Customized shower shelf to guest bathroom 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

PARTITIONS

Glass Partition

Crystal clear glass partitions (W-500) comprising metal trims


(W-900) including hardware, fittings, fixings and accessories
complete as per Manufacturer's recommondation

A 2600 mm high 21 m 0.00

B Extra over for 700 x 2600 mm door 13 Nr 0.00

Crystal clear glass partitions (W-500) comprising metal trims


(W-902) including hardware, fittings, fixings and accessories
complete as per Manufacturer's recommondation

C 2600 mm high 4 m 0.00

Crystal clear glass partitions (W-500) comprising metal trims


(W-903) including hardware, fittings, fixings and accessories
complete as per Manufacturer's recommondation

D 2050 mm high, above bath tub 2 m 0.00

Mesh laminated glass partitions (W-501) comprising metal


trims (W-900) including hardware, fittings, fixings and
accessories complete as per Manufacturer's
recommondation

E 2600 mm high 4 m 0.00

F Extra over for 700 x 2600 mm door 1 Nr 0.00

14 mm thick mesh laminated glass partitions (J-505) to both


sides of framing cosisting satin brass (J-900) trims including
framing, sub framing, anchoring, concealed supports,
finishing, decorations, fixings and accessories complete

G To Ground floor courtyard 18 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION K - ACCESSORIES (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION K -Page: 1 0.00

BILL 02/SECTION K -Page: 2 0.00

BILL 02/SECTION K -Page: 3 0.00

BILL 02/SECTION K -Page: 4 0.00

BILL 02/SECTION K -Page: 5 0.00

BILL 02/SECTION K -Page: 6 0.00

BILL 02/SECTION K -Page: 7 0.00

BILL 02/SECTION K -Page: 8 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION K -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION L - EQUIPMENT

GENERALLY

Equipment including all necessary fittings, fixing and


accessories complete all in accordance with 220812_LV48 -
White Goods Schedule

A Type WG01, Combi - microwave oven built-in 2 Nr 0.00

B Type WG02, Combi - microwave oven built-in 1 Nr 0.00

C Type WG03, Coffee machine 1 Nr 0.00

D Type WG04, Warming drawer built-in 1 Nr 0.00

E Type WG05, Vario gas wok 1 Nr 0.00

F Type WG06, Vario gas cooktop 1 Nr 0.00

G Type WG07, Domino cooking zone ceramic 1 Nr 0.00

H Type WG08, Integrated vario freezer 1 Nr 0.00

J Type WG09, Integrated vario freezer 1 Nr 0.00

K Type WG10, Integrated canopy extractor 1 Nr 0.00

L Type WG11, Integrated dishwasher 3 Nr 0.00

M Type WG12, Water purifier 1 Nr 0.00

N Type WG13, Wine cooler 2 Nr 0.00

P Type WG14, Wine cooler 10 Nr 0.00

Q Type WG15, Under counter refrigerator 6 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION L -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION L - EQUIPMENT (CONT'D)

GENERALLY (CONT'D)

Equipment including all necessary fittings, fixing and


accessories complete all in accordance with 220812_LV48 -
White Goods Schedule (Cont'd)

A Type WG16, Safe 2 Nr 0.00

B Type WG17, Vapour fire 2 Nr 0.00

C Type WG18, Popcorn machine 1 Nr 0.00

D TV screens 8 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION L -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION L - EQUIPMENT (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION L -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION L -Page: 1 0.00

BILL 02/SECTION L -Page: 2 0.00

BILL 02/SECTION L -Page: 3 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION L -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS

GENERALLY

Loose Furniture

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule

A Type LF01, Customized wooden bench 1 Nr 0.00

B Type LF02, Side table 1 Nr 0.00

C Type LF03, Modular C-shaped sofa 2 Nr 0.00

D Type LF04, Armchair 2 Nr 0.00

E Type LF05, Pouf 2 Nr 0.00

F Type LF06, Pouf 1 Nr 0.00

G Type LF07, Coffee table 2 Nr 0.00

H Type LF08, Coffee table 1 Nr 0.00

J Type LF09, Coffee table 1 Nr 0.00

K Type LF10, Side table 3 Nr 0.00

L Type LF11, Side table 1 Nr 0.00

M Type LF12, Dining chair 10 Nr 0.00

N Type LF13, Customized dining table 1 Nr 0.00

P Type LF14, Bar stool 3 Nr 0.00

Q Type LF15, Dining chair 6 Nr 0.00

R Type LF16, Sofa 1 Nr 0.00

S Type LF17, Armchair 2 Nr 0.00

T Type LF18, Chair 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF19, Desk 1 Nr 0.00

B Type LF20, Chair 2 Nr 0.00

C Type LF21, Side table 1 Nr 0.00

D Type LF22, Coffee table 1 Nr 0.00

E Type LF23, Coffee table 1 Nr 0.00

F Type LF24, Side table 1 Nr 0.00

G Type LF25, Side table 1 Nr 0.00

H Type LF26, Bed king size 1 Nr 0.00

J Type LF27, Night stand 1 Nr 0.00

K Type LF28, Night stand 1 Nr 0.00

L Type LF29, Bed 1 Nr 0.00

M Type LF30, Night stand 2 Nr 0.00

N Type LF31, Bed 1 Nr 0.00

P Type LF32, Bed 1 Nr 0.00

Q Type LF33, Side table 2 Nr 0.00

R Type LF34, Bed 1 Nr 0.00

S Type LF35, Night stand 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF36, Crib 1 Nr 0.00

B Type LF37, Bed 2 Nr 0.00

C Type LF38, Night stand 2 Nr 0.00

D Type LF39, Bed 6 Nr 0.00

E Type LF40, Night stands 6 Nr 0.00

F Type LF42, Console 1 Nr 0.00

G Type LF43, Sofa 2 Nr 0.00

H Type LF44, Coffee table 1 Nr 0.00

J Type LF46, Coffee table 1 Nr 0.00

K Type LF47, Bench 1 Nr 0.00

L Type LF48, Armchair 1 Nr 0.00

M Type LF49, Side table 1 Nr 0.00

N Type LF50, Pouf 1 Nr 0.00

P Type LF51, Chair 1 Nr 0.00

Q Type LF52, L shaped sofa 2 Nr 0.00

R Type LF53, Round table 1 Nr 0.00

S Type LF54, Desk 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF55, Chair 1 Nr 0.00

B Type LF56, Pous 2 Nr 0.00

C Type LF57, Sofa 1 Nr 0.00

D Type LF58, Chair 1 Nr 0.00

E Type LF59, Pouf 1 Nr 0.00

F Type LF60, Coffee table 1 Nr 0.00

G Type LF61, Pouf 1 Nr 0.00

H Type LF62, Bench 1 Nr 0.00

J Type LF63, Armchair 1 Nr 0.00

K Type LF64, Chair 1 Nr 0.00

L Type LF65, Stool 2 Nr 0.00

M Type LF66, Ottoman 1 Nr 0.00

N Type LF67, Love seat 1 Nr 0.00

P Type LF68, Table 1 Nr 0.00

Q Type LF69, Chair 2 Nr 0.00

R Type LF70, Chair 2 Nr 0.00

S Type LF71, L shaped sofa 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF72, Side table 1 Nr 0.00

B Type LF73, Pouf 1 Nr 0.00

C Type LF74, C shaped sofa 1 Nr 0.00

D Type LF75, Armchair 2 Nr 0.00

E Type LF76, Coffee table 1 Nr 0.00

F Type LF77, Side table 1 Nr 0.00

G Type LF78, Side table 2 Nr 0.00

H Type LF79, Side table 1 Nr 0.00

J Type LF80, Side table 2 Nr 0.00

K Type LF81, Pouf 1 Nr 0.00

L Type LF82, Bar stool 2 Nr 0.00

M Type LF83, Bar stool 3 Nr 0.00

N Type LF84, Customized upholstered bar stool 4 Nr 0.00

P Type LF86-A, Armchair 1 Nr 0.00

Q Type LF87, Armchair 2 Nr 0.00

R Type LF88, Sofa 1 Nr 0.00

S Type LF90, Side table 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF93, Sofa 1 Nr 0.00

B Type LF94, Bean bag 1 Nr 0.00

C Type LF95, Coffee table 1 Nr 0.00

D Type LF96, Stool 1 Nr 0.00

E Type LF97, Side table 1 Nr 0.00

F Type LF98, Sofa 1 Nr 0.00

G Type LF99, Pouf 1 Nr 0.00

H Type LF100, Coffee table 1 Nr 0.00

J Type LF101, Coffee table 1 Nr 0.00

K Type LF104, Home theatre seating 6 Nr 0.00

L Type LF105, Massage bed 1 Nr 0.00

M Type LF106, Barber chair 1 Nr 0.00

N Type LF107, Bar chair 2 Nr 0.00

P Type LF108, Armchair 4 Nr 0.00

Q Type LF109, Coffee table 2 Nr 0.00

R Type LF110, Dining table 1 Nr 0.00

S Type LF111, Chair 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Loose Furniture (Cont'd)

Loose furniture including all necessary accessories complete


all in accordance with 220812_LV48_FF&E Schedule
(Cont'd)

A Type LF112, Swing 1 Nr 0.00

B Type LF113, Bench 1 Nr 0.00

C Type LF114, Bench 1 Nr 0.00

D Type LF115, Coffee table 1 Nr 0.00

E Type LF125, Wall unit 1 Nr 0.00

F Type LF126, Pouf 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Rugs

Rugs including all necessary accessories complete all in


accordance with the Specifications and Schedules

A Type LR01, Living room, overall size 7285 x 6745 mm 1 Nr 0.00

B Type LR02, Dining area, overall size 5655 x 2645 mm 1 Nr 0.00

Type LR03, Master bedroom 1, overall size 3000 x 2400


C 1 Nr 0.00
mm

D Type LR04, Master bedroom 1, 3000 mm dia. 1 Nr 0.00

E Type LR05, Guest bed room 1, overall size 3000 x 2400 mm 1 Nr 0.00

F Type LR06, Guest bed room 1, 1800 mm dia. 1 Nr 0.00

G Type LR07, Office area, overall size 3635 x 2480 mm 1 Nr 0.00

H Type LR08, Office area, overall size 2070 x 3060 mm 1 Nr 0.00

Type LR09, Seating area, overall size 4465 x 3145 mm


J 1 Nr 0.00
(Oval shaped)

Type LR10, Master bed room 2, overall size 2400 x 3000


K 1 Nr 0.00
mm

Type LR11, Master bed room 2, overall size 4080 x 3420


L 1 Nr 0.00
mm (Irregular shaped)

Type LR12, Master bed room 3, overall size 2400 x 2980


M 1 Nr 0.00
mm

N Type LR13, Master bed room 3, 3000 mm dia. 1 Nr 0.00

P Type LR14, Kids bed room 1, overall size 2700 x 2225 mm 1 Nr 0.00

Q Type LR15, Kids bed room 2, 2400 mm dia. 1 Nr 0.00

R Type LR16, Kids bed room 2, overall size 1500 x 2400 mm 1 Nr 0.00

S Type LR17, Nursery, 2400 mm dia. 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

GENERALLY (CONT'D)

Rugs (Cont'd)

Rugs including all necessary accessories complete all in


accordance with the Specifications and Schedules (Cont'd)

A Type LR18, Nursery, overall size 3000 x 2000 mm 1 Nr 0.00

B Type LR19, Guest bed room 2, overall size 2400 x 3000 mm 1 Nr 0.00

Type LR20, Golf simulation room, overall size 2965 x 3165


C 1 Nr 0.00
mm

D Type LR21, Kids play room, overall size 3100 x 2200 mm 1 Nr 0.00

E Type LR22, Win lounge room, overall size 3000 x 3000 mm 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

CURTAIN TRACK

Window treatment in minimal rail consisting fabric drapery,


decorative fittings and accessories, trims and tassels
including concealed top rail and support framing, fixings and
accessories complete all in accordance with 220812_LV48 -
Window Treatment Schedule

A Type WT01, Drapery motorized track system - Sheer 31 Nr 0.00

B Type WT02, Drapery motorized track system- Black out 18 Nr 0.00

Proprietary window treatment consisting blinds, decorative


fittings and accessories, operating mechanisms, concealed
supports, fixings and accessories complete all in accordance
with 220812_LV48 - Window Treatment Schedule

C Type WT03, Roller blinds - Motorized 2 Nr 0.00

D Type WT04, Venetian blinds 3 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION M - FURNISHINGS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION M -Page: 1 0.00

BILL 02/SECTION M -Page: 2 0.00

BILL 02/SECTION M -Page: 3 0.00

BILL 02/SECTION M -Page: 4 0.00

BILL 02/SECTION M -Page: 5 0.00

BILL 02/SECTION M -Page: 6 0.00

BILL 02/SECTION M -Page: 7 0.00

BILL 02/SECTION M -Page: 8 0.00

BILL 02/SECTION M -Page: 9 0.00

BILL 02/SECTION M -Page: 10 0.00

BILL 02/SECTION M -Page: 11 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION M -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION P - CONVEYING SYSTEMS

Vertical Transport System

Supply, install, test and commission the elevator lift to


Manufacturer's details

A Passenger lift 1 item 0.00

Sundries

The contractor is to allow for the following incidental work;

B Co-ordinating with other's installations 1 item 0.00

Setting out the works, marking positions of holes, mortices


C 1 item 0.00
and the like

Cutting of forming holes, mortices, chases or the like and


D 1 item 0.00
making good structures and finishing disturbed

Building in or cutting and pinning brackets or the like and


E 1 item 0.00
making good structures and finishings disturbed

All supports which shall include fixings, anchors, insulating


F 1 item 0.00
blocks, anti-vibration devices, and the like

All identification which shall include plates, discs, labels,


G 1 item 0.00
charts, colour coding and the like

All necessary protective painting including removing


H protective coating or wrapping, cleaning or polishing 1 item 0.00
exposed surfaces

Testing and commissioning which shall include operating


J 1 item 0.00
completed installations and providing fuel and power

Providing manufacturers recommended tools and spare


K 1 item 0.00
parts for equipment

Providing all necessary documents including ''as built''


L 1 item 0.00
drawings, operating instructions and maintenance manuals

All builders work in connection with the whole of the


M 1 item 0.00
conveying systems

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION P -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION P - CONVEYING SYSTEMS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION P -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION P -Page: 1 0.00

BILL 02/SECTION P -Page: 2 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION P -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS

DISPOSAL INSTALLATIONS

Rainwater Installations

Above ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 4514; including all necessary supports, fixings
and accessories complete all as Drawings

A 110 mm Diameter pipes 45 m 0.00

Rainwater outlet; complete all in accordance with the


Drawings

B Fixed to 110. mm Diameter pipes 10 Nr 0.00

Rain water discharge point, including discharge plate, pipe


works and all necessary fixings and accessories complete
all in accordance with the Drawings

C Free rainwater discharge point 10 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations

Below ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 4660; including all necessary supports, fixings
and accessories complete all as Drawings

A 32 mm Diameter pipes 8 m 0.00

B 40 mm Diameter pipes 2 m 0.00

C 50 mm Diameter pipes 3 m 0.00

D 82 mm Diameter pipes 23 m 0.00

E 110 mm Diameter pipes 139 m 0.00

F 160 mm Diameter pipes 79 m 0.00

Above ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 4514; including all necessary supports, fixings
and accessories complete all as Drawings

G 50 mm Diameter pipes 20 m 0.00

H 82 mm Diameter pipes 148 m 0.00

J 110 mm Diameter pipes 103 m 0.00

K 160 mm Diameter pipes 16 m 0.00

Above ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 5255; including all necessary supports, fixings
and accessories complete all as Drawings

L 32 mm Diameter pipes 41 m 0.00

M 40 mm Diameter pipes 28 m 0.00

N 50 mm Diameter pipes 14 m 0.00

P 82 mm Diameter pipes 62 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations (Cont'd)

Above ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 5255; including all necessary supports, fixings
and accessories complete all as Drawings (Cont'd)

A 110 mm Diameter pipes 63 m 0.00

B 160 mm Diameter pipes 26 m 0.00

Drain valves; complete all in accordance with the Drawings

C Fixed to 110 mm Diameter pipes 1 Nr 0.00

Gate valves; complete all in accordance with the Drawings

D Fixed to 82 mm Diameter pipes 1 Nr 0.00

Check valves; complete all in accordance with the Drawings

E Fixed to 82 mm Diameter pipes 1 Nr 0.00

Emergency pumping connection; complete all in accordance


with the Drawings

F Fixed to 82 mm Diameter pipes 1 Nr 0.00

Floor cleanout; complete all in accordance with the Drawings

G Fixed to 100 mm Diameter pipes 2 Nr 0.00

H Fixed to 160 mm Diameter pipes 1 Nr 0.00

Cleanout; complete all in accordance with the Drawings

J Fixed to 50 mm Diameter pipes 1 Nr 0.00

K Fixed to 82 mm Diameter pipes 16 Nr 0.00

L Fixed to 110 mm Diameter pipes 21 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations (Cont'd)

Cleanout; complete all in accordance with the Drawings


(Cont'd)

A Fixed to 160 mm Diameter pipes 3 Nr 0.00

Rodding eye; complete all in accordance with the Drawings

B Fixed to 110 mm Diameter pipes 16 Nr 0.00

Vent cowl; complete all in accordance with the Drawings

C Fixed to 82 mm Diameter pipes 2 Nr 0.00

Balcony drain; complete all in accordance with the Drawings

D Fixed to 50 mm Diameter pipes 2 Nr 0.00

Area drain; complete all in accordance with the Drawings

E Fixed to 50 mm Diameter pipes 2 Nr 0.00

Shower channel drain; complete all in accordance with the


Drawings

F 70 mm width 9 m 0.00

Channel grating; complete all in accordance with the


Drawings

G 250 mm width 7 m 0.00

Catch basin; complete with 300 x 300 heavy duty grating


and strainer, all in accordance with the Drawings

H Fixed to 110 mm Diameter pipes; ref CB-1 1 Nr 0.00

J Fixed to 110 mm Diameter pipes; ref CB-2 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations (Cont'd)

Floor trap; complete with chromium plated brass screw


down grating and min. 50 mm dia access plug, all in
accordance with the Drawings

A Fixed to 82 mm Diameter pipes; ref FT 26 Nr 0.00

Sand trap; complete with 10 mm holes sediment bucket,


160 mm dia access cap and 600 x 600 mm M.D recessed
sand trap cover, all in accordance with the Drawing DR_03

B 800 x 800 mm 3 Nr 0.00

Dry gully trap; complete all in accordance with the Drawing


DR_03

C 600 x 600 x 600 mm 3 Nr 0.00

Gully trap; complete with 150 x 150 hopper with frame &
grate, all in accordance with the Drawing DR_03

D 300 x 300 x 560 mm 3 Nr 0.00

Dry manhole; including excavation, backfilling, depositing,


compacting, removal of surplus, blinding, concrete,
formwork, reinforcement, blockwork, internal motar
rendering, waterproofing, manhole cover with frame and all
necessary finishes, pipeworks, fixings and accessories; all in
accordance with Drawings DR 03

E 600 x 600 mm 3 Nr 0.00

Manhole; including excavation, backfilling, depositing,


compacting, removal of surplus, blinding, concrete,
formwork, reinforcement, blockwork, internal motar
rendering, waterproofing, ductile iron cover with frame and
all necessary finishes, pipeworks, fixings and accessories; al
in accordance with Drawings DR 03

Type A manhole, ref MH-01 size 600 x 600 x 650 mm, with
F 1 Nr 0.00
600 x 600 mm light duty ductile iron manhole cover

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations (Cont'd)

Manhole; including excavation, backfilling, depositing,


compacting, removal of surplus, blinding, concrete,
formwork, reinforcement, blockwork, internal motar
rendering, waterproofing, ductile iron cover with frame and
all necessary finishes, pipeworks, fixings and accessories; al
in accordance with Drawings DR 03 (Cont'd)

Type A manhole, ref MH-02 size 600 x 600 x 550 mm, with
A 1 Nr 0.00
600 x 600 mm light duty ductile iron manhole cover and vent

Type A manhole, ref MH-03 size 600 x 600 x 620 mm, with
B 1 Nr 0.00
600 x 600 mm light duty ductile iron manhole cover

Type A manhole, ref MH-04 size 600 x 600 x 670 mm, with
C 1 Nr 0.00
600 x 600 mm heavy duty ductile iron manhole cover

Type A manhole, ref MH-05 size 600 x 600 x 780 mm, with
D 1 Nr 0.00
600 x 600 mm heavy duty ductile iron manhole cover

Type A backdrop manhole, ref MH-06 size 600 x 600 x 860


E mm, with 600 x 600 mm heavy duty ductile iron manhole 1 Nr 0.00
cover

Final inspection chamber; including excavation, backfilling,


depositing, compacting, removal of surplus, blinding,
concrete, formwork, reinforcement, blockwork, internal
motar rendering, waterproofing, ductile iron cover with frame
and all necessary finishes, pipeworks, fixings and
accessories; all in accordance with Drawings DR 100

Type A final inspection chambr, ref MH-07 size 600 x 600 x


F 780 mm, with 600 x 600 mm heavy duty ductile iron manhole 1 Nr 0.00
cover and vent

Lifting station; including excavation, backfilling, depositing,


compacting, removal of surplus, blinding, concrete,
formwork, reinforcement, blockwork, waterproofing, heavy
duty double seal GRP sealing plater with frame and all
necessary finishes, pipeworks, fixings and accessories; all in
accordance with Drawings

G 2000 x 2000 mm lifting station (Measured on plan) 1 Nr 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Soil, Waste and Vent Installations (Cont'd)

Connection to main drainage network including additional


pipe lengths, fittings, excavation, bedding and making good
of all works disturbed complete all as Drawings

A 160 mm diameter 1 No. 0.00

Pumps; complete with driving motor, local control panel,


base and anti-vibration mounting, wiring and controls,
switches/sensors, lifting chain, guide bar, valves ancillaries
and all necessary accessories and connections; complete all
in accordance with the Drawings

Drainage sump pump sets; 1 duty + 1 stand-by; capable of


B 1 Nr 0.00
handling 3 L/s at 2 bar head; ref. SP 1

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Kitchen Waste System

Above ground polyvinyl chloride (uPVC) pipe work and


fittings to BS 5255; including all necessary supports, fixings
and accessories complete all as Drawings

A 40 mm Diameter pipes 3 m 0.00

B 80 mm Diameter pipes 2 m 0.00

Cleanout; complete all in accordance with the Drawings

C Fixed to 82 mm Diameter pipes 1 Nr 0.00

Floor trap; complete with chromium plated brass screw


down grating and min. 50 mm dia access plug, all in
accordance with the Drawings

D Fixed to 82 mm Diameter pipes; ref FT 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

DISPOSAL INSTALLATIONS (CONT'D)

Condensate Drains

Allow for the provision of Condensate pipework system,


including all fittings, accessories and connections, complete
in accordance with the Drawings

A Condensate pipes; diameter varied 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QB - DISPOSAL INSTALLATIONS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QB -Page: 1 0.00

BILL 02/SECTION QB -Page: 2 0.00

BILL 02/SECTION QB -Page: 3 0.00

BILL 02/SECTION QB -Page: 4 0.00

BILL 02/SECTION QB -Page: 5 0.00

BILL 02/SECTION QB -Page: 6 0.00

BILL 02/SECTION QB -Page: 7 0.00

BILL 02/SECTION QB -Page: 8 0.00

BILL 02/SECTION QB -Page: 9 0.00

BILL 02/SECTION QB -Page: 10 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QB -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS

WATER INSTALLATIONS

Cold Water Installations

Below ground Class E, PVC pipes; including fittings, beds


and surrounds, excavation, backfill, disposal of surplus
excavated materials, thrust blocks as required, all necessary
accessories and connections; complete all in accordance
with the Drawings

40 mm diameter pipes in DEWA main connection to water


A 43 m 0.00
tank

Below ground polypropylene-random (PP-R) pipes; including


fittings, beds and surrounds, excavation, backfill, disposal of
surplus excavated materials, thrust blocks as required, all
necessary accessories and connections; complete all in
accordance with the Drawings

B 20 mm diameter pipes 67 m 0.00

C 32 mm diameter pipes 7 m 0.00

D 63 mm diameter pipes 3 m 0.00

Above ground crosslinked polyethylene (PEX) pipes;


including fittings, mineral wool insulation, fixing, supports and
all necessary accessories and connections; complete all in
accordance with the Drawings

E 15 mm diameter pipes 157 m 0.00

F 20 mm diameter pipes 54 m 0.00

Above ground polypropylene-random (PP-R) pipes; including


fittings, mineral wool insulation, fixing, supports and all
necessary accessories and connections; complete all in
accordance with the Drawings

G 20 mm diameter pipes 124 m 0.00

H 25 mm diameter pipes 111 m 0.00

J 32 mm diameter pipes 34 m 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS (CONT'D)

WATER INSTALLATIONS (CONT'D)

Cold Water Installations (Cont'd)

Above ground polypropylene-random (PP-R) pipes; including


fittings, mineral wool insulation, fixing, supports and all
necessary accessories and connections; complete all in
accordance with the Drawings (Cont'd)

A 40 mm diameter pipes 20 m 0.00

B 50 mm diameter pipes 26 m 0.00

C 63 mm diameter pipes 40 m 0.00

Isolation valves; complete all in accordance with the


Drawings

D Fixed to 20 mm diameter pipes 6 Nr 0.00

E Fixed to 25 mm diameter pipes 11 Nr 0.00

F Fixed to 32 mm diameter pipes 2 Nr 0.00

Angle valves; complete all in accordance with the Drawings

G Fixed to 15 mm diameter pipes 50 Nr 0.00

H Fixed to 20 mm diameter pipes 11 Nr 0.00

Hose bib including isolation valve; complete all in


accordance with the Drawings

J Fixed to 20 mm diameter pipes 7 Nr 0.00

Water hammer arrestors; complete all in accordance with


the Drawings

K Fixed to 20 mm diameter pipes 10 Nr 0.00

L Fixed to 25 mm diameter pipes 5 Nr 0.00

M Fixed to 32 mm diameter pipes 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS (CONT'D)

WATER INSTALLATIONS (CONT'D)

Cold Water Installations (Cont'd)

Water meter; including 2 nos. isolation valves; complete all


in accordance with the Drawings

A Fixed to 40 mm diameter pipes 1 Nr 0.00

Water meter manhole; including excavation, backfilling,


depositing, compacting, removal of surplus, blinding,
concrete, formwork, reinforcement, blockwork,
waterproofing, 600 x 600 medium duty cast iron manhole
cover with frame and all necessary finishes, pipeworks,
fixings and accessories; all in accordance with Drawings

B 600 x 600 x 450 mm water meter chamber 1 Nr 0.00

Pumps; complete with driving motor, local control panel,


base and anti-vibration mounting, wiring and controls,
switches/sensors, lifting chain, guide bar, valves ancillaries
and all necessary accessories and connections; complete all
in accordance with the Drawings

Booster pump sets; 1 duty + 1 stand-by; capable of handling


C 1 Nr 0.00
3.25 lps at 2.7 bar head, including pressure vessel

Insulated GRP domestic water tank; including, concrete,


formwork, reinforcement, blockwork, waterproofing, all
necessary finishes, pipeworks, fixings and accessories; all in
accordance with Drawings

D 2000 x 2000 x 2300 mm size, 8000 m3 capacity 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS (CONT'D)

WATER INSTALLATIONS (CONT'D)

Hot Water Installations

Above ground crosslinked polyethylene (PEX) pipes;


including fittings, mineral wool insulation, fixing, supports and
all necessary accessories and connections; complete all in
accordance with the Drawings

A 15 mm Diameter pipes 55 m 0.00

B 20 mm Diameter pipes 39 m 0.00

Above ground polypropylene-random (PP-R) pipes; including


fittings, mineral wool insulation, fixing, supports and all
necessary accessories and connections; complete all in
accordance with the Drawings

C 20 mm Diameter pipes 419 m 0.00

D 25 mm Diameter pipes 67 m 0.00

E 32 mm Diameter pipes 36 m 0.00

F 40 mm Diameter pipes 4 m 0.00

G 50 mm Diameter pipes 21 m 0.00

Isolation valves; complete all in accordance with the


Drawings

H Fixed to 20 mm diameter pipes 36 Nr 0.00

J Fixed to 25 mm diameter pipes 3 Nr 0.00

K Fixed to 50 mm diameter pipes 2 Nr 0.00

Angle valves; complete all in accordance with the Drawings

L Fixed to 15 mm diameter pipes 22 Nr 0.00

M Fixed to 20 mm diameter pipes 13 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS (CONT'D)

WATER INSTALLATIONS (CONT'D)

Hot Water Installations (Cont'd)

Water hammer arrestors; complete all in accordance with


the Drawings

A Fixed to 20 mm diameter pipes 14 Nr 0.00

B Fixed to 25 mm diameter pipes 1 Nr 0.00

Solar water heater system; including all inline ancillaries,


valve assemblies, control panel, enclosure, all necessary
supports, fixings and accessories complete all as Drawings

C Solar water heater system, 310 L 2 Nr 0.00

Hot water circulation pumps; including all inline ancillaries,


valve assemblies, motor, motor control panel, emergency
power electrical wires, conduits, controls and heavy gauge
robust sheet steel enclosure, all necessary supports, fixings
and accessories complete all as Drawings

D 80 L/s, at 2.0 bar head, (one duty and one standby) 1 Set 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QC - WATER INSTALLATIONS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QC -Page: 1 0.00

BILL 02/SECTION QC -Page: 2 0.00

BILL 02/SECTION QC -Page: 3 0.00

BILL 02/SECTION QC -Page: 4 0.00

BILL 02/SECTION QC -Page: 5 0.00

BILL 02/SECTION QC -Page: 6 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QC -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT

SPACE HEATING AND AIR TREATMENT

Air Conditioning Installations

Galvanised sheet steel rectangular ductwork and fittings,


including supports, manufactured and fitted in accordance
with the relevant standards, complete as shown on Drawings

Supply air duct

A Gauge 24 600 m2 0.00

Return air duct

B Gauge 24 40 m2 0.00

Fresh air ductwork

C Gauge 24 200 m2 0.00

25 mm thick 24 kg/m3 aluminium foil faced fiberglass


rigidboard insulation wrapped with 6oz size canvas cloth
and 2 Coates of IVS-30 to ductwork, complete all in
accordance with the Drawings

D Fixed externally to rectangular air ductwork 815 m2 0.00

E Fixed externally to rectangular air ductwork riser 20 m2 0.00

50 mm thick 48 kg/m3 aluminium foil faced fiberglass


rigidboard insulation wrapped with 8oz size canvas cloth
and 2 Coates of IVS-30 to ductwork, complete all in
accordance with the Drawings

F Fixed externally to rectangular air ductwork 4 m2 0.00

0.08 mm thick anodized aluminium cladding including fittings


to ductwork, all in accordance with the Drawings

G Fixed to rectangular air ductwork 838 m2 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

13 mm thick 32 kg/m3 sound liner acoustic lining insulation


to ductwork, complete all in accordance with the Drawings

A Fixed internally to rectangular air ductwork 161 m2 0.00

Volume control dampers to suit duct size, complete in


accordance with the Drawings

B 200 x 150 mm 5 Nr 0.00

C 250 x 150 mm 2 Nr 0.00

D 250 x 200 mm 37 Nr 0.00

E 250 x 250 mm 12 Nr 0.00

F 300 x 200 mm 36 Nr 0.00

G 300 x 250 mm 77 Nr 0.00

H 350 x 200 mm 10 Nr 0.00

J 350 x 250 mm 21 Nr 0.00

K 400 x 200 mm 8 Nr 0.00

L 400 x 250 mm 54 Nr 0.00

M 400 x 300 mm 15 Nr 0.00

N 450 x 300 mm 3 Nr 0.00

P 500 x 250 mm 16 Nr 0.00

Q 500 x 300 mm 11 Nr 0.00

R 550 x 300 mm 4 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Volume control dampers to suit duct size, complete in


accordance with the Drawings (Cont'd)

A 600 x 300 mm 2 Nr 0.00

Sound attenuator, complete in accordance with the


Drawings

B 450 x 400 mm 1 Nr 0.00

C 550 x 400 mm 1 Nr 0.00

Flexible ducts including insulation, complete in accordance


with the Drawings

D 150 mm diameter, 0.0 - 0.5 m length 227 Nr 0.00

E 150 mm diameter, 0.5 - 1.0 m length 75 Nr 0.00

Slot linear supply diffuser, complete all in accordance with


the Drawings

F 2-Slot, 750 mm approximate length 1 Nr 0.00

G 2-Slot, 1000 mm approximate length 4 Nr 0.00

H 2-Slot, 1250 mm approximate length 15 Nr 0.00

J 2-Slot, 1500 mm approximate length 20 Nr 0.00

K 2-Slot, 1750 mm approximate length 7 Nr 0.00

L 2-Slot, 2000 mm approximate length 20 Nr 0.00

M 2-Slot, 2100 mm approximate length 2 Nr 0.00

N 2-Slot, 2250 mm approximate length 6 Nr 0.00

P 2-Slot, 2500 mm approximate length 4 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Slot linear supply diffuser, complete all in accordance with


the Drawings (Cont'd)

A 2-Slot, 2750 mm approximate length 2 Nr 0.00

B 2-Slot, 3000 mm approximate length 1 Nr 0.00

Slot linear return diffuser, complete all in accordance with the


Drawings

C 2-Slot, 750 mm approximate length 15 Nr 0.00

D 2-Slot, 1000 mm approximate length 4 Nr 0.00

E 2-Slot, 1250 mm approximate length 6 Nr 0.00

F 2-Slot, 1500 mm approximate length 20 Nr 0.00

G 2-Slot, 1750 mm approximate length 6 Nr 0.00

H 2-Slot, 2000 mm approximate length 20 Nr 0.00

J 2-Slot, 2100 mm approximate length 2 Nr 0.00

K 2-Slot, 2250 mm approximate length 6 Nr 0.00

L 2-Slot, 2500 mm approximate length 4 Nr 0.00

M 2-Slot, 2750 mm approximate length 2 Nr 0.00

N 2-Slot, 3000 mm approximate length 1 Nr 0.00

Return air grilles, complete all in accordance with the


Drawings

P 400 x 300 mm 1 Nr 0.00

Q 500 x 250 mm 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Fresh air grilles, complete all in accordance with the


Drawings

A 100 x 100 mm 4 Nr 0.00

B 150 x 100 mm 9 Nr 0.00

C 200 x 100 mm 3 Nr 0.00

D 200 x 150 mm 6 Nr 0.00

E 250 x 200 mm 1 Nr 0.00

F 350 x 200 mm 1 Nr 0.00

Supply diffusers, complete all in accordance with the


Drawings

G 450 x 450 mm 3 Nr 0.00

Return diffusers, complete all in accordance with the


Drawings

H 450 x 450 mm 3 Nr 0.00

Supply linear bar grille, complete all in accordance with the


Drawings

J 2000 x 50 mm 2 Nr 0.00

Return linear bar grille, complete all in accordance with the


Drawings

K 2000 x 50 mm 2 Nr 0.00

Fresh air intake with sand trap louver, complete all in


accordance with the Drawings

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Fresh air intake with sand trap louver, complete all in


accordance with the Drawings

A 500 x 400 mm 1 Nr 0.00

Allow for the provision of Laundry extract ductwork, including


accessories and connections, complete in accordance with
the Drawings

B Laundry extract ductwork, including fittings and accessories 1 item 0.00

Fresh air handling units with heat wheel, comprising unit


casing, drip tray, panel filter, bag filter, drive guards, drive
belts, pulleys, drain plugs, fans, coil, wiring to local control
panel, thermostat, sensors, dampers, vibration isolator, and
all necessary accessories as detailed in the equipment
schedule and in accordance with the Drawings

22.2 kW total cooling coil, 946 lps supply air flow, 500 Pa
C 1 Nr 0.00
ESP, ref. FAHU-01

VRF Condensate units comprising unit casing, drip tray, heat


pump, heat exchanger, UV relay, drain plugs, fans, coil,
wiring to local control panel, filter dryer, isolation valve, sight
glass, vibration isolator, and all necessary accessories as
detailed in the equipment schedule and in accordance with
the Drawings

98.7 kW total cooling coil, consisting 3 no of modules , ref.


D 1 Nr 0.00
VRF-ODU-01

70.20 kW total cooling coil, consisting 2 no of modules , ref.


E 1 Nr 0.00
VRF-ODU-02

70.20 kW total cooling coil, consisting 2 no of modules , ref.


F 1 Nr 0.00
VRF-ODU-03

92.5 kW total cooling coil, consisting 3 no of modules , ref.


G 1 Nr 0.00
VRF-ODU-04

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

VRF Condensate units comprising unit casing, drip tray, heat


pump, heat exchanger, UV relay, drain plugs, fans, coil,
wiring to local control panel, filter dryer, isolation valve, sight
glass, vibration isolator, and all necessary accessories as
detailed in the equipment schedule and in accordance with
the Drawings (Cont'd)

A VRF unit for FAHU-01 1 Nr 0.00

Fan coil units, comprising of unit casing, drain pan, cooling


coils, fan motor, filters, wiring, thermostats, sensors,
insulation as required and all necessary accessories and
connections; as detailed in the equipment schedule and in
accordance with the Drawings

Ducted type, 4.9 kW total cooling duty, 253 lps airflow, ref.
B 1 Nr 0.00
FCU-B-01

Ducted type, 3.9 kW total cooling duty, 250 lps airflow, ref.
C 1 Nr 0.00
FCU-B-02

Ducted type, 3.2 kW total cooling duty, 158 lps airflow, ref.
D 1 Nr 0.00
FCU-B-03

Ducted type, 4.9 kW total cooling duty, 253 lps airflow, ref.
E 1 Nr 0.00
FCU-B-04

Ducted type, 9.8 kW total cooling duty, 533 lps airflow, ref.
F 1 Nr 0.00
FCU-B-05

Ducted type, 14.0 kW total cooling duty, 650 lps airflow, ref.
G 2 Nr 0.00
FCU-B-06

Ducted type, 9.8 kW total cooling duty, 533 lps airflow, ref.
H 1 Nr 0.00
FCU-G-01

Ducted type, 4.9 kW total cooling duty, 253 lps airflow, ref.
J 1 Nr 0.00
FCU-G-02

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Fan coil units, comprising of unit casing, drain pan, cooling


coils, fan motor, filters, wiring, thermostats, sensors,
insulation as required and all necessary accessories and
connections; as detailed in the equipment schedule and in
accordance with the Drawings (Cont'd)

Ducted type, 6.2 kW total cooling duty, 320 lps airflow, ref.
A 1 Nr 0.00
FCU-G-03

Ducted type, 7.8 kW total cooling duty, 383 lps airflow, ref.
B 1 Nr 0.00
FCU-G-04

Ducted type, 12.2 kW total cooling duty, 600 lps airflow, ref.
C 1 Nr 0.00
FCU-G-05

Ducted type, 2.5 kW total cooling duty, 150 lps airflow, ref.
D 1 Nr 0.00
FCU-G-06

Ducted type, 12.2 kW total cooling duty, 600 lps airflow, ref.
E 5 Nr 0.00
FCU-G-07

Ducted type, 12.2 kW total cooling duty, 600 lps airflow, ref.
F 1 Nr 0.00
FCU-F-01

Ducted type, 4.9 kW total cooling duty, 253 lps airflow, ref.
G 1 Nr 0.00
FCU-F-02

Ducted type, Ducted type, 9.8 kW total cooling duty, 533 lps
H 1 Nr 0.00
airflow, ref. FCU-F-03

Ducted type, 7.8 kW total cooling duty, 383 lps airflow, ref.
J 1 Nr 0.00
FCU-F-04

Ducted type, 9.8 kW total cooling duty, 533 lps airflow, ref.
K 1 Nr 0.00
FCU-F-05

Ducted type, 14.0 kW total cooling duty, 650 lps airflow, ref.
L 1 Nr 0.00
FCU-F-06

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Fan coil units, comprising of unit casing, drain pan, cooling


coils, fan motor, filters, wiring, thermostats, sensors,
insulation as required and all necessary accessories and
connections; as detailed in the equipment schedule and in
accordance with the Drawings (Cont'd)

Ducted type, 7.8 kW total cooling duty, 383 lps airflow, ref.
A 1 Nr 0.00
FCU-F-07

Ducted type, 14.0 kW total cooling duty, 650 lps airflow, ref.
B 3 Nr 0.00
FCU-F-08

Ducted type, 12.2 kW total cooling duty, 600 lps airflow, ref.
C 1 Nr 0.00
FCU-R-01

Ducted type, 6.2 kW total cooling duty, 350 lps airflow, ref.
D 1 Nr 0.00
FCU-R-02

Ducted type, 4.9 kW total cooling duty, 253 lps airflow, ref.
E 1 Nr 0.00
FCU-R-03

Ducted type, 9.8 kW total cooling duty, 533 lps airflow, ref.
F 1 Nr 0.00
FCU-R-04

Ducted type, 3.9 kW total cooling duty, 250 lps airflow, ref.
G 1 Nr 0.00
FCU-R-05

Ducted type, 7.4 kW total cooling duty, 533 lps airflow, ref.
H 1 Nr 0.00
FCU-R-06

Ducted type, 3.9 kW total cooling duty, 250 lps airflow, ref.
J 1 Nr 0.00
FCU-R-07

Ducted type, 12.2 kW total cooling duty, 600 lps airflow, ref.
K 1 Nr 0.00
FCU-R-08

Copper refrigerant pipe; including fittings and all necessary


fixings and accessories; all in accordance with the drawings
and Drawings

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

SPACE HEATING AND AIR TREATMENT (CONT'D)

Air Conditioning Installations (Cont'd)

Copper refrigerant pipe; including fittings and all necessary


fixings and accessories; all in accordance with the drawings
and Drawings

A Refrigerant pipes; diameter varied 409 m 0.00

19mm thick closed cell rubber insulation wrapped with 6oz


size canvas cloth to refrigerant pipes, complete all in
accordance with the Drawings

B To refrigerant pipes; diameter varied 409 m 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QD - SPACE HEATING AND AIR TREATMENT


(CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QD -Page: 1 0.00

BILL 02/SECTION QD -Page: 2 0.00

BILL 02/SECTION QD -Page: 3 0.00

BILL 02/SECTION QD -Page: 4 0.00

BILL 02/SECTION QD -Page: 5 0.00

BILL 02/SECTION QD -Page: 6 0.00

BILL 02/SECTION QD -Page: 7 0.00

BILL 02/SECTION QD -Page: 8 0.00

BILL 02/SECTION QD -Page: 9 0.00

BILL 02/SECTION QD -Page: 10 0.00

BILL 02/SECTION QD -Page: 11 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QD -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION

EXTRACT VENTILATION

Mechanical Ventilation System

Galvanised sheet steel rectangular ductwork and fittings,


including supports, manufactured and fitted in accordance
with the relevant standards, complete as shown on Drawings

Exhaust air duct

A Gauge 24 242 m2 0.00

25 mm thick 24 kg/m3 aluminium foil faced fiberglass


rigidboard insulation wrapped with 6oz size canvas cloth
and 2 Coates of IVS-30 to ductwork, complete all in
accordance with the Drawings

B Fixed externally to rectangular air ductwork 216 m2 0.00

C Fixed externally to rectangular air ductwork riser 19 m2 0.00

50 mm thick 48 kg/m3 aluminium foil faced fiberglass


rigidboard insulation wrapped with 8oz size canvas cloth and
2 Coates of IVS-30 to ductwork, complete all in accordance
with the Drawings

D Fixed externally to rectangular air ductwork 8 m2 0.00

0.08 mm thick anodized aluminium cladding including fittings


to ductwork, all in accordance with the Drawings

E Fixed to rectangular air ductwork 225 m2 0.00

Volume control dampers to suit duct size, complete in


accordance with the Drawings

F 100 x 100 mm 18 Nr 0.00

G 150 x 100 mm 20 Nr 0.00

H 150 x 150 mm 2 Nr 0.00

J 200 x 100 mm 11 Nr 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION (CONT'D)

EXTRACT VENTILATION (CONT'D)

Mechanical Ventilation System (Cont'd)

Volume control dampers to suit duct size, complete in


accordance with the Drawings (Cont'd)

A 200 x 150 mm 8 Nr 0.00

B 250 x 150 mm 2 Nr 0.00

C 250 x 200 mm 1 Nr 0.00

D 300 x 150 mm 1 Nr 0.00

E 300 x 200 mm 1 Nr 0.00

F 350 x 200 mm 3 Nr 0.00

G 450 x 300 mm 1 Nr 0.00

H 800 x 300 mm 1 Nr 0.00

J 900 x 400 mm 1 Nr 0.00

Sound attenuator, complete in accordance with the


Drawings

K 900 x 400 mm 2 Nr 0.00

Flexible ducts including insulation, complete in accordance


with the Drawings

L 150 mm diameter, 0.0 - 0.5 m length 20 Nr 0.00

M 150 mm diameter, 1.0 - 1.5 m length 2 Nr 0.00

Slot linear exhaust diffuser, complete all in accordance with


the Drawings

N 2-Slot, 500 mm approximate length 24 Nr 0.00

Exhaust air grilles, complete all in accordance with the


Drawings

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION (CONT'D)

EXTRACT VENTILATION (CONT'D)

Mechanical Ventilation System (Cont'd)

Exhaust air grilles, complete all in accordance with the


Drawings

A 200 x 100 mm 5 Nr 0.00

B 250 x 150 mm 3 Nr 0.00

C 300 x 150 mm 1 Nr 0.00

D 300 x 200 mm 1 Nr 0.00

E 450 x 300 mm 1 Nr 0.00

F 800 x 300 mm 1 Nr 0.00

G 900 x 400 mm 1 Nr 0.00

Exhaust air diffusers, complete all in accordance with the


Drawings

H 100 x 100 mm 1 Nr 0.00

J 150 x 100 mm 1 Nr 0.00

K 100 mm dia. 1 Nr 0.00

Return diffusers, complete all in accordance with the


Drawings

L 450 x 450 mm 3 Nr 0.00

Supply linear bar grille, complete all in accordance with the


Drawings

M 2000 x 50 mm 2 Nr 0.00

Return linear bar grille, complete all in accordance with the


Drawings

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION (CONT'D)

EXTRACT VENTILATION (CONT'D)

Mechanical Ventilation System (Cont'd)

Return linear bar grille, complete all in accordance with the


Drawings

A 2000 x 50 mm 2 Nr 0.00

Exhaust air louver, complete all in accordance with the


Drawings

B 300 x 150 mm 1 Nr 0.00

C 450 x 400 mm 1 Nr 0.00

D 900 x 400 mm 1 Nr 0.00

Non return damper to suit duct size, complete in accordance


with the Drawings

E 800 x 300 mm 1 Nr 0.00

Fire rated extract air fans, including motors, diffusers, back


draft shutters, attenuators, and all necessary anti-vibration
mountings and supports, dampers, electrical/control wiring,
conduits and controls, fly nets, weather proof louvers
accessories and connections to ductwork, complete as per
the equipment schedule and in accordance with the
Drawings

F 1800 / 2400 lps flowrate, dual speed type, BEF-02 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION (CONT'D)

EXTRACT VENTILATION (CONT'D)

Kitchen Exhaust System

Allow for the provision of kitchen exhaust ductwork, including


insulation, kitchen extract grille, accessories and
connections, complete in accordance with the Drawings

A Kitchen exhaust ductwork, including fittings and accessories 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QE - EXTRACT VENTILATION (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QE -Page: 1 0.00

BILL 02/SECTION QE -Page: 2 0.00

BILL 02/SECTION QE -Page: 3 0.00

BILL 02/SECTION QE -Page: 4 0.00

BILL 02/SECTION QE -Page: 5 0.00

BILL 02/SECTION QE -Page: 6 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QE -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QF - PROTECTION INSTALLATIONS

PROTECTIVE INSTALLATIONS

Fire Extinguishers

A 2kg ABC Dry powder extinguisher 4 Nr 0.00

B 5lbs CO2 extinguisher 9 Nr 0.00

C Fire blanket 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QF -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)
SECTION QF - PROTECTION INSTALLATIONS
(CONT'D)

Additional items
Any items that may not be covered elsewhere in the Bills of
Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other item necessary to
form a complete installation, must be itemised and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QF -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QF -Page: 1 0.00

BILL 02/SECTION QF -Page: 2 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QF -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QG - SPECIAL INSTALLATION

SPECIAL INSTALLATIONS

Building Management and Control System

Supply, install, test and commission and hand-over the


complete Building Management Systems (BMS) and all
associated automatic controls and monitoring system;
including but not limited to the complete automatic control
and monitoring of HVAC, mechanical, electrical, public
health, all associated interfacing works; complete with
suitable programming system, all associated equipment,
connections, support, fittings and all necessary and ancillary
works to complete the operational control and monitoring of
the whole system; all in accordance with the Drawings

A Generally 1 item 0.00

Gas Installation

Supply, install, test and commission and hand-over the


complete LP Gas supply systems including but not limited to
Meter assembly, detectors, valves, regulators, switches,
pipe and screens with all associated equipment,
connections, support, fittings and all necessary and ancillary
works to complete the operational control and monitoring of
the whole system; all in accordance with the Drawings

B Allow Provisional sum for LP gas installation 1 PS 0.00

C Tenderers markup and general attendance %

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QG -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QG - SPECIAL INSTALLATION (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QG -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QG -Page: 1 0.00

BILL 02/SECTION QG -Page: 2 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QG -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QH - MECHANICAL SUNDRIES

MECHANICAL SUNDRIES

The following are in respect of the whole of the Mechanical


Engineering Installations

Allow for the following and executing to the satisfaction of the


A 1 item 0.00
Engineer

Marking positions of holes, mortices, chases and the like in


B 1 item 0.00
the structure

C Providing samples 1 item 0.00

Co-ordinating with other trades including additional materials


D and labour to produce a fully and operable installation 1 item 0.00
(interfacing work with BMS and fire alarm system)

E Providing all necessary spares and tools 1 item 0.00

F Providing identification, colour coding and labelling 1 item 0.00

Conduct training to the owner's representative in the


G 1 item 0.00
operation, maintenance and service of the whole installation

Provide all attendance necessary during commissioning of


all plant, equipment and apparatus under the Contract, and
H 1 item 0.00
each equipment shall be represented by factory trained
specialists for demonstration

J Specialists for demonstration 1 item 0.00

K Providing shop drawings 1 item 0.00

L Providing "as built" drawings 1 item 0.00

M Providing all necessary supports 1 item 0.00

N Providing all necessary protection 1 item 0.00

P Providing pipeline painting and all associated works 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QH -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QH - MECHANICAL SUNDRIES (CONT'D)

MECHANICAL SUNDRIES (CONT'D)

The following are in respect of the whole of the Mechanical


Engineering Installations (Cont'd)

A Providing operation and maintenance manuals 1 item 0.00

Testing and commissioning, including making good all


B defects and re-testing as necessary and leaving all in sound 1 item 0.00
and perfect working order or completion

Providing pipe sleeves for all pipes and ducts passing


C 1 item 0.00
through floors, walls and ceiling

Providing all fire sealing around collars, pipes, ducts and the
D 1 item 0.00
like and passing through fire rated floor, walls and ceiling

Providing maintenance for all mechanical installations for the


E 1 item 0.00
period stated in the Drawings

F Providing service ducts for pipe risers 1 item 0.00

G Providing all builder's work 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QH -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION QH - MECHANICAL SUNDRIES (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QH -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION QH -Page: 1 0.00

BILL 02/SECTION QH -Page: 2 0.00

BILL 02/SECTION QH -Page: 3 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION QH -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS

ELECTRICAL INSTALLATIONS

Low Voltage Distribution

Allow for connection to 2 No. DEWA meter including IP rated


cabinet enclosure complete with all necessary equipment,
accessories and coordination with DEWA; complete all as
Drawings and instructions

A Connection DEWA meter cabinet 2 Nr 0.00

Main Distribution Panel board; including all necessary


connections, framework, enclosures, supports, conduit,
trunking, trays, fixings and accessories; complete all as
Drawings

B MDB-1, TCL - 199.74KW, MD - 169.77KW 1 Nr 0.00

C MDB-2, TCL - 179.10KW, MD - 152.23KW 1 Nr 0.00

Distribution Panel board; iincluding all necessary


connections, framework, enclosures, supports, conduit,
trunking, trays, fixings and accessories; complete all as
Drawings

D DB-BF L, TCL - 9.98KW 1 Nr 0.00

E DB-BF P, TCL - 49.20KW 1 Nr 0.00

F DB-GF L, TCL - 16.985KW 1 Nr 0.00

G DB-GF P, TCL - 27.10KW 1 Nr 0.00

H DB-FF L, TCL - 20.395KW 1 Nr 0.00

J DB-FF P, TCL - 20.30KW 1 Nr 0.00

K DB-RF L, TCL - 10.71KW 1 Nr 0.00

L DB-RF P, TCL - 24.90KW 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Low Voltage Distribution (Cont'd)

XLPE/SWA/PVC Copper cable to include ECC, drawn into


and including conduit, cable tray, required termination glands
complete all as Drawings

From Meter Cabinet to MDB-1; 1x 4C 300 mm2


A 1 Item 0.00
XLPE/SWA/PVC + 1C 150 mm2

From Meter Cabinet to MDB-2; 1x 4C 300 mm2


B 1 Item 0.00
XLPE/SWA/PVC + 1C 150 mm2

From MDB-1 to DB-BF L; 1x 4C 10 mm2 XLPE/SWA/PVC


C 1 Item 0.00
+ 1C 10 mm2

From MDB-1 to DB-BF P; 1x 4C 35 mm2 XLPE/SWA/PVC


D 1 Item 0.00
+ 1C 25 mm2

From MDB-1 to DB-GF L; 1x 4C 10 mm2 XLPE/SWA/PVC


E 1 Item 0.00
+ 1C 10 mm2

From MDB-1 to DB-GF P; 1x 4C 16 mm2 XLPE/SWA/PVC


F 1 Item 0.00
+ 1C 16 mm2

From MDB-1 to VRF-1; 1x 4C 25 mm2 XLPE/SWA/PVC +


G 1 Item 0.00
1C 16 mm2

From MDB-1 to LIFT; 1x 4C 10 mm2 XLPE/SWA/PVC + 1C


H 1 Item 0.00
10 mm2

From MDB-1 to Swimming pool; 1x 4C 25 mm2


J 1 Item 0.00
XLPE/SWA/PVC + 1C 16 mm2

From MDB-2 to DB-FF L; 1x 4C 16 mm2 XLPE/SWA/PVC +


K 1 Item 0.00
1C 16 mm2

From MDB-2 to DB-FF P; 1x 4C 16 mm2 XLPE/SWA/PVC


L 1 Item 0.00
+ 1C 16 mm2

From MDB-2 to DB-RF L; 1x 4C 10 mm2 XLPE/SWA/PVC


M 1 Item 0.00
+ 1C 10 mm2

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Low Voltage Distribution (Cont'd)

XLPE/SWA/PVC Copper cable to include ECC, drawn into


and including conduit, cable tray, required termination glands
complete all as Drawings (Cont'd)

From MDB-2 to DB-RF P; 1x 4C 16 mm2 XLPE/SWA/PVC


A 1 Item 0.00
+ 1C 16 mm2

From MDB-2 to VRF-3; 1x 4C 16 mm2 XLPE/SWA/PVC +


B 1 Item 0.00
1C 16 mm2

From MDB-2 to VRF-4; 1x 4C 25 mm2 XLPE/SWA/PVC +


C 1 Item 0.00
1C 16 mm2

From MDB-2 to VRF-2; 1x 4C 16 mm2 XLPE/SWA/PVC +


D 1 Item 0.00
1C 16 mm2

From MDB-2 to FAHU CU; 1x 4C 10 mm2 XLPE/SWA/PVC


E 1 Item 0.00
+ 1C 10 mm2

From MDB-2 to FAHU; 1x 4C 6 mm2 XLPE/SWA/PVC + 1C


F 1 Item 0.00
6 mm2

Isolators connected to Main distribution Panel board


complete with framework, enclosures, supports, conduit,
trunking, tray and all necessary accessories complete all as
Drawings

G TP isolator IP65, for FAHU; ref. MDB-2 1 Nr 0.00

H TP isolator IP65, for FAHU CU; ref. MDB-2 1 Nr 0.00

J TP isolator IP65, for Lift; ref. MDB-1 1 Nr 0.00

K TP isolator IP65, for Swimming pool; ref. MDB-1 1 Nr 0.00

L TP isolator IP65, for VRF-1; ref. MDB-1 1 Nr 0.00

M TP isolator IP65, for VRF-2; ref. MDB-2 1 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Low Voltage Distribution (Cont'd)

Isolators connected to Main distribution Panel board


complete with framework, enclosures, supports, conduit,
trunking, tray and all necessary accessories complete all as
Drawings (Cont'd)

A TP isolator IP65, for VRF-3; ref. MDB-2 1 Nr 0.00

B TP isolator IP65, for VRF-4; ref. MDB-2 1 Nr 0.00

Isolators connected to Distribution Panel board complete


with framework, enclosures, supports, conduit, trunking, tray
and all necessary accessories complete all as Drawings

C TP isolator IP65, for gate barrier; ref. DB BF P 1 Nr 0.00

D TP isolator IP65, for pump room; ref. DB BF P 2 Nr 0.00

E TP isolator IP65, for transfer pump; ref. DB BF P 1 Nr 0.00

F TP isolator IP65, for gate; ref. DB GF P 1 Nr 0.00

G TP isolator IP65, for roof top; ref. DB RF P 4 Nr 0.00

Lighting Control Panel; including framework, enclosures,


supports, conduit, trunking, tray and all necessary
accessories complete all as Drawings

H Lighting control panel for basement floor 1 Nr 0.00

J Lighting control panel for ground floor 1 Nr 0.00

K Lighting control panel for first floor 1 Nr 0.00

L Lighting control panel for roof floor 1 Nr 0.00

Lighting Switches; including all necessary connections,


fixings and accessories; complete all as Drawings

M Lighting Switches (provisional ) 116 Nr 0.00


To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Small Power Installation

Wiring in approved cables, drawing into and including


conduit where required, complete with boxes, fittings and
supporting brackets, including main cable trunking/tray;
complete all as Drawings Drawings

From distribution board to

A 13A 2 pole & earth weatherproof switch socket outlet points 31 Nr 0.00

B 13A double socket single switched outlet points 64 Nr 0.00

C 13A single socket single switched outlet points 83 Nr 0.00

D 13A double floor socket outlet points 5 Nr 0.00

E 15A socket outlet points 2 Nr 0.00

F 20A socket outlet with DP switch points 2 Nr 0.00

G 32A TP industrial socket points 4 Nr 0.00

H Switched fused spur outlet points 38 Nr 0.00

J Curtain socket points 28 Nr 0.00

K Cooker socket points 2 Nr 0.00

L 300L roof solar water heater points placed on roof top 2 Nr 0.00

Accessories including fixings and connections complete all


as Drawings

M 13A 2 pole & earth weatherproof switch socket outlets 31 Nr 0.00

N 13A double socket single switched outlets 64 Nr 0.00

P 13A single socket single switched outlets 83 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Small Power Installation (Cont'd)

Accessories including fixings and connections complete all


as Drawings (Cont'd)

A 13A double floor socket outlets 5 Nr 0.00

B 15A socket outlets 2 Nr 0.00

C 20A socket outlet with DP switches 2 Nr 0.00

D 32A TP industrial sockets 4 Nr 0.00

E Switched fused spur outlets 38 Nr 0.00

F Curtain sockets 28 Nr 0.00

G Cooker sockets 2 Nr 0.00

H 300L roof solar water heaters placed on roof top 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

General Lighting Installation

Cables, conduits and trunking between distribution boards,


lighting points and switches in concealed work below
suspended ceilings and surface mounted above suspended
ceilings; complete all as Drawings

A Lighting control panel for basement floor 1 Nr 0.00

B Lighting control panel for ground floor 1 Nr 0.00

C Lighting control panel for first floor 1 Nr 0.00

D Lighting control panel for roof floor 1 Nr 0.00

E Lighting Switches (provisional ) 116 Nr 0.00

Lighting control panel and accessories including switches,


cover plates and switch plates, grids, earth terminals, phase
barriers and all other components and final connection
complete all as Drawings

F Lighting control panel for basement floor 1 Nr 0.00

G Lighting control panel for ground floor 1 Nr 0.00

H Lighting control panel for first floor 1 Nr 0.00

J Lighting control panel for roof floor 1 Nr 0.00

K Lighting Switches (provisional ) 116 Nr 0.00

Cables, conduits and trunking between distribution boards,


lighting points and switches in concealed work below
suspended ceilings and surface mounted above suspended
ceilings; complete all as Drawings

L Lighting points 600 Nr 0.00

M Linear lighting points 277 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 7


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

General Lighting Installation (Cont'd)

Cables, conduits and trunking between distribution boards,


lighting points and switches in concealed work below
suspended ceilings and surface mounted above suspended
ceilings; complete all as Drawings (Cont'd)

A External lighting points 25 Nr 0.00

Light fittings including fixings, lamps and connections


complete all as Drawings

Ref. L1 - Surface mounted weatherproof lighting fixture,


B 10 Nr 0.00
IP66, 38W

C Ref. L2 - Recessed downlight fixture, IP54, 8W 40 Nr 0.00

Ref. L3 - Ceiling recessed adjustable trimless downlight,


D 91 Nr 0.00
IP20, 10.5W

Ref. L4 - Ceiling recessed adjustable trimless downlight,


E 194 Nr 0.00
IP54, 7.3W

Ref. L5.1 - Ceiling recessed trimless linear light fixture, IP44,


F 9 Nr 0.00
58W

Ref. L5.2 - Ceiling recessed trimless linear light fixture, IP44,


G 5 Nr 0.00
29W

Ref. L6 - Ceiling recessed adjustable trimless downlight,


H 12 Nr 0.00
IP20, 10.5W

ref. L7 - Ceiling recessed adjustable trimless downlight,


J 10 Nr 0.00
IP20, 10.5W

Ref. L8 - Surface recessed mounted linear fixture, IP20,


K 34 Nr 0.00
33W

L Ref. L9.1 - Recessed mounted puck light, IP20, 2W 2 Nr 0.00

Ref. L9.2 - Ceiling recessed adjustable trimless downlight,


M 12 Nr 0.00
IP54, 7.3W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 8


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

General Lighting Installation (Cont'd)

Light fittings including fixings, lamps and connections


complete all as Drawings (Cont'd)

A Ref. L10 - Recessed mounted trimless spotlight, IP20, 8.6W 14 Nr 0.00

B Ref. L13 - Floor recessed uplight, IP68, 3W 16 Nr 0.00

C Ref. L14 - Recessed mounted track, IP20, 13W 13 Nr 0.00

D Ref. L16 - Recessed mounted track, IP20, 9.6W 7 Nr 0.00

E Ref. L17 - Track mounted spolight, IP20, 14.4W 64 Nr 0.00

F Ref. L18 - Wall recessed light fixture, IP20, 3W 6 Nr 0.00

G Lighting ref. LX 4 Nr 0.00

H Ref. L11 - Ceiling recessed linear LED, IP65, 16W/m 73 m 0.00

Ref. L12 - Recessed wall to ceiling mounted linear light,


J 64 m 0.00
IP20, 28.9W/m

K Ref. TR - Ceiling recessed mounted track, IP20 20 m 0.00

L Ref. L17 track - Mounted inside the cove light, IP20 38 m 0.00

Ref. L17 LED - Surface mounted LED strip with profile and
M 74 m 0.00
opal diffuser for cove, IP20, 9.6W

N Lighting ref. LS1 165 m 0.00

Ref. LS1.1 - Surface mounted LED strip with profile and opal
P 603 m 0.00
diffuser for cove, IP20, 9.6W

Ref. LS1.2 - Surface mounted LED strip with profile and opal
Q 108 m 0.00
diffuser for cove, IP65, 9.6W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 9


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

General Lighting Installation (Cont'd)

Light fittings including fixings, lamps and connections


complete all as Drawings (Cont'd)

Ref. LS2.1 - Surface mounted LED strip with profile and opal
A 119 m 0.00
diffuser for cove, IP20, 9.6W

Ref. LS2.2 - Surface mounted dual bend flexible neon with


B 63 m 0.00
bendable bracket IP67, 9W

Ref. LS3 - Surface mounted dual bend flexible neon with


C 127 m 0.00
bendable bracket IP67, 9W

Ref. LS4 - Surface mounted LED strip with profile and opal
D 20 m 0.00
diffuser for handrail, IP20, 9.6W

Ref. LS5 - Surface mounted LED strip with profile and opal
E 111 m 0.00
diffuser, IP20, 9.6W

F Ref. LS6 - LED light to stretched ceiling , IP20, 80W 57 m2 0.00

G Wall light for boundary wall 17 Nr 0.00

H Lighting for roof top 8 Nr 0.00

J Allow for strip light in BU310 joinery 1 Item 0.00

K Allow for strip light in BU303 joinery 1 Item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 10


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Emergency Lighting Installation

Cables, conduits and trunking between distribution boards,


lighting points and switches in concealed work below
suspended ceilings and surface mounted above suspended
ceilings; complete all as Drawings

A Emergency lighting points 8 Nr 0.00

Emergency light fittings including fixings, lamps and


connections complete in accordance with the Specifications

B Emergency lighting ref. E1 8 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 11


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Specialist Lighting Installation

Cables, conduits and trunking between distribution boards,


lighting points and switches in concealed work below
suspended ceilings and surface mounted above suspended
ceilings; complete all as Drawings

A Lighting points; pendant lights 44 Nr 0.00

B Lighting points; surface mounted lights 2 Nr 0.00

C Lighting points; wall lights 48 Nr 0.00

D Lighting points; table lamp lights 6 Nr 0.00

E Lighting points; floor lamp lights 9 Nr 0.00

Specialist light fittings including fixings, lamps and


connections complete in accordance with the Drawings

Ref. CL01 - Decorative pendant lighting fixture for pooja


F 1 Nr 0.00
room, IP40, 6.5W

Ref. CL02 - Decorative pendant lighting fixture for breakfast


G 1 Nr 0.00
area, IP20, 35W

Ref. CL03 - Decorative pendant lighting fixture for breakfast


H 1 Nr 0.00
area, IP20, 37W

Ref. CL04 - Decorative pendant lighting fixture for dining,


J 3 Nr 0.00
IP20

Ref. CL05 - Decorative pendant lighting fixture for office,


K 1 Nr 0.00
IP20, 37W

Ref. CL06 - Decorative pendant lighting fixture for GF


L 1 Nr 0.00
master bedroom, IP20, 2W

Ref. CL07 - Decorative pendant lighting fixture for GF


M 1 Nr 0.00
master bedroom, IP20, 2W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 12


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Specialist Lighting Installation (Cont'd)

Specialist light fittings including fixings, lamps and


connections complete in accordance with the Drawings
(Cont'd)

Ref. CL08 - Decorative pendant lighting fixture for GF


A 2 Nr 0.00
master bedroom, IP 40, 15W

Ref. CL09 - Decorative pendant lighting fixture for guest


B 4 Nr 0.00
washroom, IP20, 3.6W

Ref. CL10 - Decorative pendant lighting fixture for GF guest


C 1 Nr 0.00
bathroom, IP20, 2W

Ref. CL11 - Decorative pendant lighting fixture for FF master


D 2 Nr 0.00
bedroom 02, IP20, 9W

Ref. CL12 - Decorative pendant lighting fixture for FF master


E 2 Nr 0.00
bathroom 02, IP20, 7W

Ref. CL13 - Decorative pendant lighting fixture for FF master


F 2 Nr 0.00
bedroom 02, IP20, 5W

Ref. CL14 - Decorative surface mounted lighting fixture for


G 1 Nr 0.00
nursery, IP20, 4W

Ref. CL15 - Decorative pendant lighting fixture for nursery


H 1 Nr 0.00
bathroom, IP20, 5W

Ref. CL16 - Decorative pendant lighting fixture for FF guest


J 1 Nr 0.00
bedroom 02, IP20, 3.5W

Ref. CL17 - Decorative pendant lighting fixture for FF guest


K 2 Nr 0.00
bedroom 02, IP20

Ref. CL18 - Decorative surface mounted lighting fixture for


L 1 Nr 0.00
kid's bedroom 02, IP20, 4W

Ref. CL19 - Decorative pendant lighting fixture for spa, IP20,


M 2 Nr 0.00
4W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 13


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Specialist Lighting Installation (Cont'd)

Specialist light fittings including fixings, lamps and


connections complete in accordance with the Drawings
(Cont'd)

A Ref. CL20 - Decorative pendant lighting fixture for gym, IP20 6 Nr 0.00

Ref. CL21 - Decorative pendant lighting fixture for wine


B 1 Nr 0.00
lounge, IP20, 2W

Ref. CL22 - Decorative pendant lighting fixture for wine


C 1 Nr 0.00
cellar, IP20, 10W

Ref. CL23 - Decorative pendant lighting fixture for wine


D 1 Nr 0.00
cellar, IP20, 30W

Ref. CL24 - Decorative pendant lighting fixture for maids


E 3 Nr 0.00
bathroom, IP20, 3W

Ref. CL25 - Decorative pendant lighting fixture for kitchen,


F 3 Nr 0.00
IP20, 8.2W

G Ref. CL26 - Decorative pendant chandelier, IP20 1 Nr 0.00

Ref. WL01 - Decorative wall lighting fixture for foyer & RF,
H 4 Nr 0.00
IP20

Ref. WL02 - Decorative wall lighting fixture for general area,


J 12 Nr 0.00
IP20, 22W

Ref. WL03 - Decorative wall lighting fixture for guest


K 2 Nr 0.00
washrooms, IP20, 8W

Ref. WL04 - Decorative wall lighting fixture for GF guest


L 1 Nr 0.00
bathroom 01, IP20, 4.5W

Ref. WL05 - Decorative wall lighting fixture for FF master


M 1 Nr 0.00
bedroom 03, IP20, 4W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 14


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Specialist Lighting Installation (Cont'd)

Specialist light fittings including fixings, lamps and


connections complete in accordance with the Drawings
(Cont'd)

Ref. WL06 - Decorative wall lighting fixture for kid's bedroom


A 6 Nr 0.00
& nursery, IP20, 7.5W

Ref. WL08 - Decorative wall lighting fixture for wine lounge,


B 4 Nr 0.00
IP20, 7W

Ref. WL09 - Decorative wall lighting fixture for cinema, IP20,


C 4 Nr 0.00
4W

Ref. WL10 - Decorative wall lighting fixture for gym, IP20,


D 2 Nr 0.00
5W

E Ref. WL11 - Decorative wall lighting fixture for spa, IP20, 2W 2 Nr 0.00

Ref. WL12.1 - Decorative wall lighting fixture for GF master


F 2 Nr 0.00
bed room, IP20, 1W

Ref. WL12.2 - Decorative wall lighting fixture for GF guest


G 2 Nr 0.00
bedroom, IP20, 1W

Ref. WL13 - Decorative wall lighting fixture for maid's room,


H 6 Nr 0.00
IP20, 7W

Ref. TL01 - Decorative table lamp for GF master bedroom,


J 1 Nr 0.00
IP20, 16W

Ref. TL02 - Decorative table lamp for GF guest bedroom


K 1 Nr 0.00
01, IP20, 28W

Ref. TL03 - Decorative table lamp for FF master bedroom


L 1 Nr 0.00
02, IP20, 4W

Ref. TL04 - Decorative table lamp for FF master bedroom


M 1 Nr 0.00
02, IP20, 4W

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 15


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Specialist Lighting Installation (Cont'd)

Specialist light fittings including fixings, lamps and


connections complete in accordance with the Drawings
(Cont'd)

Ref. TL05 - Decorative table lamp for FF Guest bedroom


A 1 Nr 0.00
02, IP20

B Ref. TL06 - Decorative table lamp for wine lounge, IP20, 6W 1 Nr 0.00

C Ref. FL01 - Decorative floor lamp for living room, IP20, 54W 1 Nr 0.00

D Ref. FL02 - Decorative floor lamp for living room, IP20, 6W 1 Nr 0.00

E Ref. FL03 - Decorative floor lamp for office, IP20, 43.2W 1 Nr 0.00

Ref. FL04 - Decorative floor lamp for GF master bedroom


F 1 Nr 0.00
01, IP20, 77W

Ref. FL05 - Decorative floor lamp for FF guest bedroom 02,


G 1 Nr 0.00
IP20, 21W

Ref. FL06 - Decorative floor lamp for FF master bedroom


H 1 Nr 0.00
02, IP20, 60W

Ref. FL07 - Decorative floor lamp for FF guest bedroom 02,


J 1 Nr 0.00
IP44

Ref. FL08 - Decorative floor to ceiling system for kids play


K 2 Nr 0.00
room, IP20

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 16


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Facade Lighting Installation

Note-
Refer to refer to the document SKY_LV48_Facade
Concept_20220811_R0

Allow Provisional Sum for Facade light fittings including


fixings, lamps and connections; complete with cables,
conduits and trunking between distribution boards, lighting
points and switches in concealed work below suspended
ceilings and surface mounted above suspended ceilings;
complete all as Drawings

A Facade lighting point installation 1 PS 0.00

B Tenderers markup and general attendance %

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 17


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Automation System Installation

Equipment and devices complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray; complete all as
Drawings

Touch panel for controlling automation, AV and BGM points


A note
measured under AV system installation

B Occupancy / Motion senor 26 Nr 0.00

C Daylight sensor 8 Nr 0.00

D Sensor module 8 Nr 0.00

E Wired keypad 46 Nr 0.00

F Curtain control module 25 Nr 0.00

Allow provisional sum for supply and installation of Home


Automation system additional equipment and accessories as
G 220812_LV48-Wiring Schedules and Home Automation PS
drawings to complete the operational control and monitoring
of the whole system as Project requirement

Tenderers markup and general attendance on Home


H %
Automation system additional work

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 18


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Earthing and Bonding System Installation

Complete electrical grounding and bonding system with


connectors terminals, bonding jumpers, earth cables, earth
rods, earth inspection pits with test links and all accessories
required to complete grounding system for electrical and
communication equipment

A Earthing and bonding system installation 1 Item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 19


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

ELECTRICAL INSTALLATIONS (CONT'D)

Lightning Protection System Installation

Lightning protection system complete with connectors


terminals, conductors, bonding jumpers and all accessories
required to complete the system

A Electrical lightning protection system 1 Item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 20


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RA - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Page: 21


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION RA -Page: 1 0.00

BILL 02/SECTION RA -Page: 2 0.00

BILL 02/SECTION RA -Page: 3 0.00

BILL 02/SECTION RA -Page: 4 0.00

BILL 02/SECTION RA -Page: 5 0.00

BILL 02/SECTION RA -Page: 6 0.00

BILL 02/SECTION RA -Page: 7 0.00

BILL 02/SECTION RA -Page: 8 0.00

BILL 02/SECTION RA -Page: 9 0.00

BILL 02/SECTION RA -Page: 10 0.00

BILL 02/SECTION RA -Page: 11 0.00

BILL 02/SECTION RA -Page: 12 0.00

BILL 02/SECTION RA -Page: 13 0.00

BILL 02/SECTION RA -Page: 14 0.00

BILL 02/SECTION RA -Page: 15 0.00

BILL 02/SECTION RA -Page: 16 0.00

BILL 02/SECTION RA -Page: 17 0.00

BILL 02/SECTION RA -Page: 18 0.00

BILL 02/SECTION RA -Page: 19 0.00

BILL 02/SECTION RA -Page: 20 0.00

BILL 02/SECTION RA -Page: 21 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RA -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS

COMMUNICATION INSTALLATIONS

AV System Installation

Equipment and accessories complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray, all in
accordance with the Drawings

A 42U AV/BGM rack 2 Nr 0.00

B Ceiling speaker 68 Nr 0.00

C Floor mounted speaker 21 Nr 0.00

D Floor mounted subwoofer 4 Nr 0.00

E Sound bar 3 Nr 0.00

F Touch panel for controlling AV, BGM and automation 23 Nr 0.00

G TV LED display with lift + swivel bracket 85" 2 Nr 0.00

H TV LED display with push + pull bracket 55" 2 Nr 0.00

J TV LED display with push + pull bracket 65" 5 Nr 0.00

K TV LED display with push + pull bracket 75" 2 Nr 0.00

L TV LED display with push + pull bracket 85" 1 Nr 0.00

Projector with fixed bracket + monitorized projector screen


M 1 Nr 0.00
190"

Allow for Tvs & sound bars in basement floor (Refer to AV-
N 1 item 0.00
301)

Allow for media interface panel audio & video input with
P 1 item 0.00
avoip encoder in roof floor cinema room (Refer to AV-301)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

COMMUNICATION INSTALLATIONS (CONT'D)

AV System Installation (Cont'd)

Equipment and accessories complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray, all in
accordance with the Drawings (Cont'd)

Allow for cinema rack in roof floor cinema room (Refer to


A 1 item 0.00
AV-301)

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

COMMUNICATION INSTALLATIONS (CONT'D)

SCS System Installation

Equipment and accessories complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray, all in
accordance with the Drawings

A 42U IT rack 1 Nr 0.00

B Single RJ45 outlet for data at low level 21 Nr 0.00

C Single RJ45 outlet for touch panel at low level 21 Nr 0.00

D Single RJ45 outlet for biometric at low level 8 Nr 0.00

E Single RJ45 outlet for access control at low level 2 Nr 0.00

F Single RJ45 outlet for intercom at low level 4 Nr 0.00

G Single RJ45 outlet for CCTV at mid level 9 Nr 0.00

H Dual RJ45 outlet for data at low level 50 Nr 0.00

J Quad RJ45 outlet for data at low level 3 Nr 0.00

K Single RJ45 outlet for WAP installed on ceiling 29 Nr 0.00

L Single RJ45 outlet for CCTV at high level 7 Nr 0.00

M Dual RJ45 outlet for data at high level 1 Nr 0.00

N Quad RJ45 outlet for data at high level 3 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

COMMUNICATION INSTALLATIONS (CONT'D)

Security System

Equipment and devices complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray, all in
accordance with the Drawings

A Access control panel 1 Nr 0.00

B Access control reader 2 Nr 0.00

C Biometric reader 7 Nr 0.00

D CCTV camera connected to comms room via CAT6A cable 15 Nr 0.00

E Door contact for monitoring 2 Nr 0.00

F Electric Lock with door monitoring 5 Nr 0.00

G Push to exit button 5 Nr 0.00

H Video intercom system (indoor system) 1 Nr 0.00

J Video intercom system (Outdoor system) 3 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 4


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

COMMUNICATION INSTALLATIONS (CONT'D)

Fire Detection and Alarm System

Equipment and devices complete as described, wiring in


approved cables, drawing into and including conduit where
required, complete with boxes, fittings and supporting
brackets, including main cable trunking/tray, all in
accordance with the Drawings

A Addressable fire alarm smoke detector 25 Nr 0.00

B Addressable fire alarm smoke detectors with sounder 11 Nr 0.00

C Addressable heat detector 3 Nr 0.00

D Addressable main fire alarm control panel 1 Nr 0.00

E Control module 2 Nr 0.00

F Fire alarm sounder with flasher weatherproof 4 Nr 0.00

G Fire alarm sounder 4 Nr 0.00

H Monitor module 2 Nr 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 5


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RB - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Page: 6


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION RB -Page: 1 0.00

BILL 02/SECTION RB -Page: 2 0.00

BILL 02/SECTION RB -Page: 3 0.00

BILL 02/SECTION RB -Page: 4 0.00

BILL 02/SECTION RB -Page: 5 0.00

BILL 02/SECTION RB -Page: 6 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RB -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RC - ELECTRICAL ENGINEERING


INSTALLATIONS

Sundries and Work Incidental to the Electrical Engineering


Installations

Identification

Allow for all necessary identification, including plates, discs,


A 1 item 0.00
labels, charts and colour coding all complete as described

Testing and commissioning

Allow for all necessary testing and commissioning, including


sterilizing and testing completed installations and all
B 1 item 0.00
necessary fuel, water and power for the commissioning
process.

Disposal

C Allow for disposal of water used in connection with the works 1 item 0.00

Tools and Spares

Allow for all necessary tools including loose keys and


D 1 item 0.00
consumables

Spares

Allow for five percent (5%) of lamps used on the project


E (BOH lighting) including emergency and instrumentation 1 item 0.00
lamps

Allow for five percent (5%) of all lighting types (FOH interior,
F Landscape & Façade lighting) including miscellaneous items 1 item 0.00
like drivers and connecting clips

Allow for other necessary spares in accordance with the


G 1 item 0.00
Contract Documents and Specifications

Documents

Allow for all necessary documents including as-built


H drawings, operating instructions and maintenance manuals 1 item 0.00
(4) sets paper prints including one (1) set of negatives

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RC -Page: 1


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RC - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

Training

Allow for training of owner's maintenance staff to the


A 1 item 0.00
satisfaction of the Owner

Builder's Work

B Provide all necessary builder's work as required 1 item 0.00

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RC -Page: 2


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

SECTION RC - ELECTRICAL ENGINEERING


INSTALLATIONS (CONT'D)

Additional items

Any items that may not be covered elsewhere in the Bills of


Quantities which the tenderer deemed to be necessary in
order to carry out the works in full compliance with the
Drawings, Specifications and any other items necessary to
form a complete installation, must be itemized and priced
below. The tenderer may provide additional sheets for this
purpose if necessary. All items under this section must be
summarized under a separate cover.

A ____________________________________ item

B ____________________________________ item

C ____________________________________ item

To Collection 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RC -Page: 3


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

COLLECTION

Total Brought Forward from Page No.

BILL 02/SECTION RC -Page: 1 0.00

BILL 02/SECTION RC -Page: 2 0.00

BILL 02/SECTION RC -Page: 3 0.00

Carried To Bill Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02/SECTION RC -Collection


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

BILL 02 - MAIN VILLA

BILL SUMMARY

Total Brought Forward from Page No.

SECTION B - SITE WORK 0.00

SECTION C - CONCRETE WORK 0.00

SECTION D - MASONRY 0.00

SECTION E - METALWORK 0.00

SECTION F - WOODWORK 0.00

SECTION G - THERMAL & MOISTURE PROTECTION 0.00

SECTION H - DOORS AND WINDOWS 0.00

SECTION J - FINISHES 0.00

SECTION K - ACCESSORIES 0.00

SECTION L - EQUIPMENT 0.00

SECTION M - FURNISHINGS 0.00

SECTION P - CONVEYING SYSTEMS 0.00

SECTION QB - DISPOSAL INSTALLATIONS 0.00

SECTION QC - WATER INSTALLATIONS 0.00

SECTION QD - SPACE HEATING AND AIR TREATMENT 0.00

SECTION QE - EXTRACT VENTILATION 0.00

SECTION QF - PROTECTION INSTALLATIONS 0.00

SECTION QG - SPECIAL INSTALLATION 0.00

SECTION QH - MECHANICAL SUNDRIES 0.00

Carried To Next Page 0.00

BILL 02 - MAIN VILLA BILL 02 -Summary


CLIENT NAME TBC
xxxxxxxxxx
BILLS OF QUANTITIES
xxxxxxxxxx
Rate Amount
Item Description Quantity Unit
(AED) (AED)

BILL 02 - MAIN VILLA

BILL SUMMARY (CONT'D)

Total Brought Forward from Page No. (Cont'd) 0.00

SECTION RA - ELECTRICAL ENGINEERING


0.00
INSTALLATIONS

SECTION RB - ELECTRICAL ENGINEERING


0.00
INSTALLATIONS

SECTION RC - ELECTRICAL ENGINEERING


0.00
INSTALLATIONS

Carried To General Summary Page 0.00

BILL 02 - MAIN VILLA BILL 02 -Summary