Loads as per NSCP 2015

Dead Loads
Concrete Weight 23.6 kN/m3
Superimposed Dead Loads
Partition Loads:
Concrete Masonry units with both faces plastered and fully grouted
200mm thk CHB 4.36 kPa (per m ht of wall)
100mm thk CBH 3.17 kPa (per m ht of wall)
Ceiling Loads:
9mm thk Gypsum board 0.072 kPa
Suspended steel channel system 0.10 kPa
20mm thk insulation foam 0.018 kPa
Metal Roofing 0.26kPa
Metal Roof Frame System
Floor Finishes
Ceramic tiles on 13mm mortar bed 0.77 kPa
Hardwood flooring 0.19 kPa
Utilities 0.02 kPa
Live Loads (Residential type occupancy)
Basic floor areas 1.9 kPa
Exterior balconies 2.9 kPa
Roof Live Load 1.0 kPa
Wind Loads – Basic wind speed considered for type IV occupancy 260 kph
directionality factor 0.85
surface roughness B
Exposure category B
idc
Earthquake Loads
Occupancy Category IV
Seismic Importance Factor, I = 1.0
Soil Type SD
Seismic Zone 4, Z = 0.40

Seismic Source Type A


Na = 5km:1.2 10km:1.0 6.6km: 1.136
Nv = 5km:1.6 10km:1.2 6.6km: 1.472
Ca = 1.1 * .44 = .484
Cv=0.94208
Ts = 0.7786
T = 0.36871
T/Ts=0.4736
bahala na etabs nakakatamad to

Total Loads per floor

Floor SuperimposedDL Remark LL Remark Roof Loads


11.99~12kN/m Wall UDL bms 1.9 kPa interiors SDL – 0.75
2F 0.115 kPa Wall area ld 2.9 kPa exteriors ceiling +roof
0.905 kPa part. wall + flr fn +u +utilities
10.68 kN/m Wall UDL bms 1.9 kPa interiors RLL – 1.0
3F 0.085 Wall area ld 2.9 kPa exteriors
1.047 kPa wall+flr fn+u+ceilin
CONCRETE SECTIONS
MATERIAL PROPERTIES
4000 psi CONCRETE TO BE USED
GR40 REBARS FOR MAIN REINF 16mm and larger
GR33 REBARS FOR TIES AND STR smaller than 16mm
C1 300X400
20MM MAIN BARS 6
12MM TIES @ 150MM OC
C2 400X400
20MM MAIN BARS 8
12MM TIES @ 150MM OC