DSE9462 ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
DUAL OUTPUT INTELLIGENT BATTERY CHARGER BS EN 61000-6-2
24V 15A & 12V 10A EMC Generic Immunity Standard for the
Industrial Environment
BS EN 61000-6-3
EMC Generic Emission Residential
Requirements
BS EN 61000-6-4
EMC Generic Emission Standard for the
Industrial Environment

OPERATING TEMPERATURE RANGE


BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
The DSE9462 is a robust, lightweight, To give added durability, reliability BS EN 60068-2-2
dual output, intelligent battery and silent operation, the charger Bb/Be Dry Heat +80 oC
* Refer to de-rating curve in the DSE9462
charger, designed for on-board utilises modern, solid state design Operator Manual
vehicle use and applications that are technology with no moving parts.
VIBRATION
using multiple batteries or loads. The BS EN 60068-2-6
charger can be programmed for Ten sweeps in each of three
different charging curves to maximise major axes
5 Hz to 8 Hz ar +/-7.5 mm,
battery life. 8 Hz to 500 Hz at 2 gn

HUMIDITY
The DSE9462 is programmed using BS EN 60068-2-30
the user-friendly DSE Configuration Db Damp Heat Cyclic 20/55 oC
Suite PC software via USB. at 95% RH 48 Hours
BS EN 60068-2-78
Cab Damp Heat Static 40 oC
The charger is mounted to the at 93% RH 48 Hours
chassis using the fixing holes that are
SHOCK
built into the case. The charger’s BS EN 60068-2-27
stylish design includes four coloured Three shocks in each of three major axes
LEDs to indicate charging status and 15 gn in 11 mS

fault conditions.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF


BATTERY CHARGER APPLICATIONS
PC J1939

1ph
N
2 2

CHARGE OUTPUTS USB PORT REMOTE VOLTAGE CANBUS AC POWER SUPPLY


SENSING

COMPATIBLE WITH VOLTS


ALL DSE MODULES

DSE9462
7

OTHER

TEMPERATURE SENSORS CONFIGURABLE INPUTS

PT1000 ONLY

2 2

ISSUE 1
®

DSEPower

DSE9462
SPECIFICATION

AC SUPPLY
VOLTAGE RANGE

DUAL OUTPUT INTELLIGENT BATTERY CHARGER 90 V to 305 V (L-N)

24V 15A & 12V 10A FREQUENCY RANGE


48 Hz to 64 Hz (L-N)

MAXIMUM INPUT CURRENT


6.0 A Max

DC OUTPUTS
CHANNEL 1
15 A DC at 24 V DC

CHANNEL 2
10 A DC at 12 V DC

RIPPLE AND NOISE


2% x Vo

EFFICIENCY AND POWER FACTOR


>90% at 0.9 pf

REGULATION
LINE
<0.5% x Vo

LOAD
1% x Vo

TEMPERATURE SENSOR INPUTS


NUMBER
2

TYPE
PT1000

PROTECTIONS
ADVANCED FEATURES • Output short circuit and polarity KEY BENEFITS Short Circuit
DC Under & Over Voltage
• Intelligent two, three and four stage inversion with auto recovery • Fully flexible to maximise the life of
DC Over Current
charging profiles • Automatic power de-rating at high the battery Reverse Polarity
• Remote voltage sensing to ambient temperatures. • Suitable for a wide range of Over Temperature
compensate for voltage drop • Optional battery temperature battery types (chemistries) AC Under & Over Voltage

• Fully independent, Adjustable compensation using PT1000 • Switched mode design


DIMENSIONS
current limit on both charge temperature sensor • Minimum 90% efficiency OVERALL
outputs; Output 1 (24 V) max 15 A, throughout full operating range 290 mm x 157 mm x 67 mm
Output 2 (12 V) max 10 A • No external intervention for
WEIGHT
• Can be used as a battery charger, manual mode
1.84 kg
power supply or both at the same Automatic Boost Mode • Multiple chargers can be linked
time • Boosts and equalises cell charge together to provide larger current OPERATING TEMPERATURE RANGE

-22 °F to +131 °F
output -30 oC to +70 oC
• Automatic or manual boost and improving battery performance and
storage charge functions to help life • Can be permenantly connected to
maintain battery condition Power Save Mode battery and AC supply. No need to STORAGE TEMPERATURE RANGE

-22 °F to +158 °F
disconnect through high load -30 oC to +70 oC
• Digital microprocessor technology • Once the battery is fully charged
the chargers switch to eco-power conditions.
• Low output ripple
• Comes supplied with an EU
• Four LEDs indication. to save energy
specified captive 2 m mains cable.
Communication
Full Protection • Can be integrated into external
• AC input under voltage systems through J1939 using
• AC input over voltage CANBUS
• Battery charger output over • Fully configurable via DSE
voltage Configuration Suite PC
• Battery charger output over Software
current
• Battery low voltage detection

RELATED MATERIALS
TITLE PART NO’S
DSE9400 Series Configuration Suite PC Software Manual 057-159
DSE Configuration Suite Installation & Operator Manual 057-151
DSE9462 Installation Instructions 053-189
DSE9462 Operator Manual 057-255

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-206/02/16(1)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

You might also like