NO. OF BLOWS 10 30 65
0.00 0 0 0 0 0 0
0.50 16 94.02 14 82.26 15 88.14
1.00 24 141.02 28 164.53 37 217.41
1.50 26 152.72 37 217.41 54 317.30
2.00 30 176.28 45 264.42 66 387.82
2.50 33 193.91 51 299.61 74 434.82
3.00 35 205.66 56 329.06 84 493.58
4.00 38 223.29 63 370.19 100 587.60
5.00 41 240.92 70 411.32 117 687.49
7.50 56 329.06 83 487.71 128 752.13
10.00 73 428.95 92 540.59 144 846.14
12.50 85 499.46 103 605.23 154 904.90
Table 1
500
400
Load in kg
300
200
100
0
1 2 3 4 5 6 7 8 9 10 11 12
Penetration in mm
Figure 1
2
FAKULTI KEJURUTERAAN AWAM
UNIVERSITI TEKNOLOGI MARA LABORATORY REPORT
600
500
400
Loadinkg
300
200
100
0
0.00 0.50 1.00 1.50 2.00 2.50 3.00 4.00 5.00 7.50 10.00 12.50
Penetration in mm
Figure 2
500
400
300
200
100
0
0.00 0.50 1.00 1.50 2.00 2.50 3.00 4.00 5.00 7.50 10.00 12.50
Penetration in mm
Figure 3
3
FAKULTI KEJURUTERAAN AWAM
UNIVERSITI TEKNOLOGI MARA LABORATORY REPORT
30
25
20
CBR
15
10
0
87.09 97.91 101.65
% MDD
Figure 4
At 97% MDD, CBR is 20.70%
PENETRATION BLOWS % MAX CBR % MDD
2.5 mm 10 14.8 87.09
2.5 mm 30 21.9 97.91
5.0 mm 65 33.33 101.65
4
FAKULTI KEJURUTERAAN AWAM
UNIVERSITI TEKNOLOGI MARA LABORATORY REPORT
Discussion
Conclusion
References
1. DETERMINATION OF CBR https://www.youtube.com/watch?
v=0cAE4cSKo_s&feature=youtu.be
2. CALIFORNIA BEARING RATIO TEST
http://www.iricen.gov.in/LAB/res/pdf/test-07.pdf