You are on page 1of 12

1 2 3 4 5 6 7

MAKKAH

MAKKAH

A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
A AR-205 A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900
600 1800 400 2150 1200 1200 1200 1200 1200 1200 1200 1200 2150 2100 2000 1000 1200 1200 1200 3800 1100 900 900 900 700
400 300 300 300 300 300 300 300 300 300 400 200 300 300 300 300 300

SLOPE 1:12
1800 1200 650 3570 2300 600 KEY PLAN

2050
UP NOTES
+0.60 1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
F.F.L
+0.32 +0.60 01
NOTED.
W1 W1 W1 W1 W1 W1 W1 W1 01 SLOPE 1:12

1320
400
AR-702 F.F.L F.F.L W2 W2 W2
AR-601
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR

200
400
A1.1 A1.1 BEFORE PREPARATION OF SHOP DRAWING.
X1 EQ. 1200 1200 1200 1200 1200 1200 1200 1200 EQ. CW 02 CW 03 G19 X1 3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL

1200
+0.60

1900
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
1900
300 300 300 300 300 420 300
1850

1850
F.F.L

1800
UP
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
UP
A1.1 A1.1
300

300
ANY ITEM ON IT.

540
X2 G18 X2 4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM

1200
1800 200
300
200 200 150
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF

4800
1200

1200

300
16000 2500 3000 3200 3200 1900 4350
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO

2380
300

‫ﻛﻬﺮﺑـــــــﺎء‬
500 2000 500 ELEC. RM THE STRUCTURE ABOVE

1200
GR-09 ‫وﺿـــﻮء‬ 5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
1200

300
4700

4700
8200

2000
ABLUTION ‫ﺣﻤﺎﻣﺎت‬

7350
8700
GR-13 REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
300

G15 TOILETS

9400
B GR-08 BEARING ON EITHER END. B

1200
SLOPE 1:12
UP

‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬ 6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE


1200

300
200
1000

1200
ENTRANCE LOBBY G17 SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
300

A1.1 GR-11
A1.1 APPROVED MINERAL WOOL OR INTUMINESCENT FOAM

3600
‫ﻣﺨﺰن‬

1200
X3 +0.60 STORAGE 5250 X3 SEALANT.
1200

F.F.L GR-10

1650
2000
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
1900

1900
3300
300

300
STRUCTURAL DRAWINGS.

1200
A1.1 A1.1 8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
X4 G16
X4
1400

W3
OF FLOOR DRAINS AND FLOOR CLEANOUTS .

200
1100

1100
1000

600
500 1500
A1.1 A1.1 9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
600 800

X5 X5 AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS

200
15700 2800 520
200
600

400 1800 900 200 , STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

2000

2000

2000
G07 G04 G01
‫ﻏﺮﻓـــﺔ ا ﻣـــﺎم‬
1400

1400

IMAM RM 01 ABBREVIATIONS
GR-12 AR-203
4000

4000
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002
7800

600
200

1000

1000

1000
10000
‫ﺣــﻮش اﻟﻤﺴــﺠﺪ‬ LEGEND
COURT
FOR LEGENDS REFER TO DWG. NO. AR00-002

2000
GR-02
11

G08 UP
A1.1 A1.1
00

200 26800

10000
2200

2000

2000
8200

G05 G02
X6 ‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬ X6 REFERENCES

26800
28200

400 +0.60

27400
01 ‫ﺣـــﺮم اﻟﻤﺴـــﺠﺪ‬ F.F.L ENTRANCE LOBBY
AR-206 UP PRAYER HALL GR-07
GR-01 +0.60

1000

1000

1000
F.F.L
950
4000

4000
+0.60
C 01 F.F.L C
1000

AR-204 G20
1650

2000

2000

2000
G09 G06 G03
400 1800 900
0 1 2 4 6 8 10m
650

800 650

A1.1 A1.1

200
SCALE 1:100 GRAPHIC SCALE
X7 X7

1000

600
1100

1100
200
1400

A1.1 A1.1

200
ISSUE STATUS

2600
X8 X8
300

1200 300 1200 300 1200 300 1200


CW 04
FOR REVISION FOR APPROVAL FOR CONSTRUCTION

1000
G14 G13
1900

1900
1700
‫ﺻــــــﺎﻟﺔ ﺗﻮزﻳــــــﻊ‬
FOR TENDER AS BUILT FOR INFO.

2225
LOBBY
1200

UP

200
A1.1 GR-05 A1.1
300

X9 200
X9

4200
200
1500
200

SLOPE 1:12
5700 3200 2525 2175 4700
1200

‫ﻣﺼـــــــﻠﻰ ﻛﺒـــــــﻴﺮات‬
2500

2500
OLD WOMEN PRAYER HALL
300

1975
‫ﺣﻤﺎﻣﺎت‬
600

GR-03 G21 TOILETS

5200
6400
8700

GR-06

200
A1.1 A1.1

200

8100
1200

1500

X10 G12 X10 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
300

6300
1500 900
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

300
2200

2000

2200
2500
1200

3700
1600 900 1100 900 1200 REV DATE REVISION DESCRIPTION CKD APR

200
300

1200
‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬
A1.1 120
ENTRANCE LOBBY A1.1
3200

X11 16000 UP GR-04


4700
X11

300
1200

W4 W4

1500
SLOPE 1:12
1850

1850
300 300 300 300 300 420 300 +0.60
1900

EQ. 1200 1200 1200 1200 1200 1200 1200 1200 EQ. G11

1200
CW 01
F.F.L
A1.1 A1.1
3220
D D
650
400

X12 X12

200
01
SLOPE 1:12 G10 W2 W2 W2 02

2120
W1 W1 W1 W1 W1 W1 W1 W1 AR-701 AR-601
1900

1620 3500 5450


3990

3990
600

01
AR-703
UP
1250 5020 650 5450 600
A1.1 A1.1
X13 X13
2470

2470
G22

A1.1 A1.1
X14 X14

400 300 300 300 300 300 300 300 300 300 300 300 300 300 200
600 1800 400 2150 1200 1200 1200 1200 1200 1200 1200 1200 2150 1600 900 1100 900 1200 1200 2400 1600 1500 2300 900 900 900 500
3250 13950 2350 5950 3400 2700 1300 900 4900
39100

E
GROUND FLOOR PLAN E
01
AR-201
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

GROUND FLOOR PLAN AR(A1-1) 101


01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

MAKKAH
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
AR-205

A A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900
2920 17400 1200 900 1100 900 1200 3600 1450 900 1450 900 900 850 900 850 900 900

KEY PLAN
NOTES
01
AR-702
W5 W5 W5
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
NOTED.

400

400
A1.1 W4 A1.1 2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
X1 1800 450 900 X1 BEFORE PREPARATION OF SHOP DRAWING.
1850 1800 1800

1850
‫ﺣﻤﺎم‬ 3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL

1700
1450 900 1450 700 900 200 TOILET
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &

2600
UP

A1.1 200 200


MZ-04 A1.1
1000 EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
X2 X2

800
800 M06 ANY ITEM ON IT.
‫ﻣﻜﺘﺒــــــــــﺔ‬

200
400
16000 LIBRARY 4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
MZ-02

6300
16400
200 200 200 THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
5300 3200 5800 3800

5700
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
4700

4700
8200
THE STRUCTURE ABOVE
9880

8700

9500
‫ﺳـــﻄﺢ‬ 5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST

4300
‫ﻏﺮﻓــﺔ ﺣــﺎرس‬

6400
ROOF UP GUARD RM REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF

5400
B MZ-03 BEARING ON EITHER END. B
+5.90 1000 2151
6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE
A1.1 A1.1

200
T.O.S M04
M02 SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
X3 X3

600
+6.00 APPROVED MINERAL WOOL OR INTUMINESCENT FOAM

450
900 1250
1900

1900
1700
F.F.L SEALANT.
M01 M03

1000
3200 5800 M05
200 7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
A1.1 A1.1

200

200
STRUCTURAL DRAWINGS.
X4 2920 X4

600
2500 900 1100 900 11200 8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
1100

1100
1100

300
1800
A1.1 A1.1

1600
OF FLOOR DRAINS AND FLOOR CLEANOUTS .
X5 X5

200
9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE

600

600
200 320
16600 3200 1880 AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
2600

1200

1200
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM
01
AR-203
4000

4000
ABBREVIATIONS

600

600
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

1200

1200
‫ﻣﺼــــــﻠﻰ اﻟﻨﺴــــــﺎء‬
WOMEN PRAYER HALL
A1.1 MZ-01 A1.1 LEGEND
27600

10000

10000

10000
8440

9400

8400
7800

6800

6800

600

600
X6 ‫ﺳـــﻄﺢ‬ X6 FOR LEGENDS REFER TO DWG. NO. AR00-002
28200

ROOF ‫ﺳـــﻄﺢ‬

27400
01 REFERENCES

1200

1200
+6.00 ROOF
AR-206
+5.65
T.O.S F.F.L +5.90
T.O.S

600

600
4000

4000
01

1200

1200
AR-204
C C

600

600
A1.1 A1.1 0 1 2 4 6 8 10m

200
1600
X7 X7

1800
2500 900 1100 900 2200 1600 7400

300
1100
1100

1100
SCALE 1:100 GRAPHIC SCALE

600
A1.1 A1.1

200

250
X8 M08 X8
W4 W4 M10 ISSUE STATUS

200
1000
M07
1900

1900
2000
450
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
M11
A1.1 A1.1 FOR TENDER AS BUILT FOR INFO.

200
X9 M09 X9
200 200 200 200
800 4300 3200 2500 2200 4900
‫ﺑﻬـــــﻮ‬
2500

2500
‫ﺳـــﻄﺢ‬

6400

6400

2000
LOBBY ‫ﺣﻤﺎم‬
ROOF TOILET
MZ-06 M12

9500
+5.90 MZ-05
8700
9880

A1.1 T.O.S A1.1

200
8200

8200
X10 +6.00 X10
F.F.L
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
2200

2000

2200
2000
1100 900 500 00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.
A1.1 A1.1
X11 UP
X11 REV DATE REVISION DESCRIPTION CKD APR
W4 4700
1850

1850
1900
400

A1.1 A1.1
400

3400
D
X12 X12 D
01 W5 W5 W5 03
1000 900 900 900 1000
AR-701 AR-601

300 300
3990

3990
3270

3270

01
2760 AR-703

A1.1 A1.1
X13 X13
2760

2760
2470

2470
A1.1 A1.1
X14 X14

300 300
2920 17400 5300 3600 1100 900 2700 1000 900 900 900 1000
3250 13950 2350 5950 3400 2700 1300 900 4900
39100

01
E AR-201 MEZZANINE FLOOR PLAN E
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

MEZZANINE FLOOR PLAN


01 SCALE 1-100
AR(A1-1) 102

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

MAKKAH
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
AR-205

A A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900
17640 5180 3600 3680 6440

KEY PLAN
NOTES
01
AR-702
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
NOTED.
A1.1 A1.1 2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR

778

778
X1 X1

200
200
10783 200 BEFORE PREPARATION OF SHOP DRAWING.
1850 3200 4000 5800

1850
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL

600

600
200
UP
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
A1.1 A1.1

200
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
X2 X2

1467

1467
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF

6750
‫ﺳـــﻄﺢ‬
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO

8600
4700

4700
THE STRUCTURE ABOVE

2621

2621
ROOF
‫ﺳـــﻄﺢ‬

9740
+10.90 +10.60 +10.90
ROOF 5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
T.O.S T.O.S T.O.S +10.60 768 REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
366
UP

B T.O.S B
BEARING ON EITHER END.
300 +10.70 6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE
A1.1 F.F.L A1.1

1316
1000 SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
X3 16800 +10.90
T.O.S
X3
APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
CW 05
1900

1900
R01 SEALANT.

200

1118
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO

200
A1.1 A1.1
STRUCTURAL DRAWINGS.
X4 X4
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
1100

1100
A1.1 A1.1 OF FLOOR DRAINS AND FLOOR CLEANOUTS .
X5 X5 9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
CW 05 CW 05 AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
200 200 420
6000 4000 6400 15180 , STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM
01
AR-203
4000

4000
ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

A1.1 A1.1 LEGEND


28440

27000
CW 05 10000 CW 05

10000
15867

15867

8160
FOR LEGENDS REFER TO DWG. NO. AR00-002

13350
X6 ‫ﺳـــﻄﺢ‬ X6
28200

27600
ROOF

27400
01 REFERENCES
AR-206 +10.60
T.O.S
4000

4000
01
AR-204
C C
CW 05 CW 05

A1.1 A1.1 0 1 2 4 6 8 10m


X7 X7
1100

1100
A1.1 A1.1 SCALE 1:100 GRAPHIC SCALE
200

X8 X8
ISSUE STATUS

1118
1900

1900
CW 05
FOR REVISION FOR APPROVAL FOR CONSTRUCTION

200
R02
A1.1 A1.1 FOR TENDER AS BUILT FOR INFO.

1316
724 1837 11677 1837 724
X9 +10.90 X9

629
T.O.S
366
‫ﺳـــﻄﺢ‬
R03 768
2500

2500
ROOF

300
200
+10.60

9740
629
T.O.S 3200 600 1100 3000 4900
A1.1 A1.1
2621

2621

200
8600

‫ﺧـــــــﺪﻣﺎت ﻣﻴﻜﺎﻧﻴﻜﻴـــــــﺔ‬

300
X10 +10.90 +10.90
‫ﺧﺪﻣﺎت‬
MECHANICAL RM X10

3000
SERVICES

4221

1200
T.O.S

6300
T.O.S RF-02
FR-01
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
2200

2200
+10.70
F.F.L
+10.70 00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

300
1100 900
1467

1467

571
A1.1 F.F.L A1.1
200

CKD APR
200

X11 X11 REV DATE REVISION DESCRIPTION

300
W4
600

600
1850

1850
508 2100 10783 2100 508

850
200 200 200 200
A1.1 A1.1
778

778
200

200

D
X12 X12 D
01
AR-701
3990

3990
01
AR-703

A1.1 A1.1
X13 X13
2470

2470
A1.1 A1.1
X14 X14

313
17640 5180 3600 1100 900 2587 5220
3250 13950 2350 5950 3400 2700 1300 900 4900
39100

01
E AR-201 ROOF PLAN E
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

ROOF PLAN
01 SCALE 1-100
AR(A1-1) 103

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

MAKKAH
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
AR-205

A A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900

KEY PLAN
NOTES
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
NOTED.
A1.1 A1.1 2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
X1 X1 BEFORE PREPARATION OF SHOP DRAWING.
1850

1850
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
A1.1 A1.1
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
X2 X2
ANY ITEM ON IT.
‫ﺳـــﻄﺢ‬ 4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
ROOF

6400
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
+13.60 (CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
T.O.S
4700

4700
THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B 3200 BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE


A1.1 A1.1
SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
X3 X3
APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
1900

1900
SEALANT.
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
A1.1 A1.1
STRUCTURAL DRAWINGS.
X4 X4
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
1100

1100
A1.1 A1.1 OF FLOOR DRAINS AND FLOOR CLEANOUTS .
X5 X5 9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM
01
AR-203
4000

4000
ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002
‫ﺳـــﻄﺢ‬
A1.1
ROOF
A1.1 LEGEND

11000
X6 +13.60 X6 FOR LEGENDS REFER TO DWG. NO. AR00-002
28200

T.O.S

27400
01 REFERENCES
AR-206
4000

4000
01
AR-204
C C
5000
A1.1 A1.1 0 1 2 4 6 8 10m
X7 X7
1100

1100
A1.1 A1.1 SCALE 1:100 GRAPHIC SCALE
X8 X8
ISSUE STATUS
1900

1900
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
A1.1 A1.1 FOR TENDER AS BUILT FOR INFO.
X9 X9
2500

2500
‫ﺳـــﻄﺢ‬
A1.1 ROOF A1.1
X10 +13.60
X10

3000
6400
T.O.S
8100 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
2200

2200
3200 4900 00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.
A1.1 A1.1
X11 X11 REV DATE REVISION DESCRIPTION CKD APR
1850

1850
A1.1 A1.1
D
X12 X12 D
3990

3990
A1.1 A1.1
X13 X13
2470

2470
A1.1 A1.1
X14 X14

3250 13950 2350 5950 3400 2700 1300 900 4900


39100

01
E AR-201 UPPER ROOF PLAN E
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

UPPER ROOF PLAN


01 SCALE 1-100
AR(A1-1) 104

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

01
AR-703
KEY PLAN
NOTES
BRONZE HILAL 1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
UNIT WITH
SCREW END NOTED.
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &

3400
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
THE STRUCTURE ABOVE

1500
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE

2900
30 mm SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
THICKNESS
DARK APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
BROWN SEALANT.
STONE
CLADDING 7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO

1000
STRUCTURAL DRAWINGS.
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE

600
OF FLOOR DRAINS AND FLOOR CLEANOUTS .
9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND

7550
FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES

30000
30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING

+13.60
T.O.S
C C

1100
0 1 2 4 6 8 10m

600

1400
3000

3000
SCALE 1:100 GRAPHIC SCALE
+10.60
T.O.S ISSUE STATUS
FOR REVISION FOR APPROVAL FOR CONSTRUCTION

3200

3100
FOR TENDER AS BUILT FOR INFO.

4000

9500
7800

7800

7800

7820
4600

4600
800
1400
13250

13950
13450

13450
+6.00
12450

F.F.L
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.

11350
2400

4000
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

3900
W1 W1 W1 W1 W1 W1 W1 W1

REV DATE REVISION DESCRIPTION CKD APR

200
200
CW 01
ALUMINUM CANOPY
1630

800
CW 04
7350
3000

3000
5400

5400
800
5850

1400
4200

D D

3800
3000
3000

2650
1200

1200

2050
450

450

450

450

450
450

450
700
30 mm THICKNESS DARK BROWN STONE CLADDING 30 mm THICKNESS DARK BROWN STONE CLADDING 30 mm THICKNESS DARK BROWN STONE CLADDING ALUMINUM CANOPY

E
ELEVATION 01 E

ELEVATION 01 AR-A1-1-201
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

KEY PLAN
NOTES
BRONZE HILAL 1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
UNIT WITH NOTED.
SCREW END
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE


30 mm SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
THICKNESS APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
DARK
BROWN
SEALANT.
STONE 7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
CLADDING STRUCTURAL DRAWINGS.
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
OF FLOOR DRAINS AND FLOOR CLEANOUTS .
9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND
FOR LEGENDS REFER TO DWG. NO. AR00-002
30 mm THICKNESS WHITE STONE CLADDING

REFERENCES

30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING

+13.60
T.O.S
C C

0 1 2 4 6 8 10m

SCALE 1:100 GRAPHIC SCALE


3000

3000
+10.60
T.O.S ISSUE STATUS
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
FOR TENDER AS BUILT FOR INFO.
3100

4000

7800

7800
4600

4600
800
13950

13450
+6.00

12450
F.F.L 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
2700
11350

00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.


4000

W1 W1 W1 W1 W1 W1 W1 W1 W3
REV DATE REVISION DESCRIPTION CKD APR
CW 03 CW 02
ALUMINUM CANOPY
1200
7350

3000
5400

5400
800

D D

4650
3450
2650

1200
450

450

450
30 mm THICKNESS DARK BROWN STONE CLADDING ALUMINUM CANOPY 30 mm THICKNESS DARK BROWN STONE CLADDING 30 mm THICKNESS DARK BROWN STONE CLADDING

E
ELEVATION 02 E

ELEVATION 02 AR-A1-1-202
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

01
AR-703
KEY PLAN
NOTES
BRONZE HILAL 1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE

1786
UNIT WITH
SCREW END NOTED.
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND

3400
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
1500 THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B 30 mm BEARING ON EITHER END. B
THICKNESS 6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE
DARK
2900

BROWN SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER


STONE APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
CLADDING
SEALANT.
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
STRUCTURAL DRAWINGS.
1000

8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE


600

OF FLOOR DRAINS AND FLOOR CLEANOUTS .


9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND
7550

30 mm THICKNESS WHITE STONE CLADDING FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES
30150

30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING

+13.60
T.O.S
C C

0 1 2 4 6 8 10m
600

2600

2600
SCALE 1:100 GRAPHIC SCALE
3000

3000
+10.60
T.O.S ISSUE STATUS
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
FOR TENDER AS BUILT FOR INFO.
W6 W6 W6 W6 W6

3900
7800

4600

4600
6900

6900
7900

7900
13950

+6.00
F.F.L
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.

3000
11350

11350
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

REV DATE REVISION DESCRIPTION CKD APR


200

200
200

ALUMINUM CANOPY ALUMINUM CANOPY


1650

800

800
5400

5400
650

D D
3800
3000

3000
3450

3450
2200

G22 G03 G02 G01


450
450

450

450

450
150

150

30 mm THICKNESS DARK BROWN STONE CLADDING ALUMINUM CANOPY 30 mm THICKNESS DARK BROWN STONE CLADDING

E
ELEVATION 03 E

ELEVATION 03 AR-A1-1-203
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

01
KEY PLAN
AR-703

NOTES
BRONZE HILAL
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE

1786
UNIT WITH
SCREW END NOTED.
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &

3400
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO

1500
THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE

2900
30 mm
THICKNESS
SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
DARK APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
BROWN SEALANT.
STONE
CLADDING 7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO

1000
STRUCTURAL DRAWINGS.
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE

600
OF FLOOR DRAINS AND FLOOR CLEANOUTS .
9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

30 mm THICKNESS WHITE STONE CLADDING


ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND

7550
FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES

30150
30 mm THICKNESS WHITE STONE CLADDING 30 mm THICKNESS WHITE STONE CLADDING

+13.60
T.O.S
C C

1000
0 1 2 4 6 8 10m

600
3000

3000
SCALE 1:100 GRAPHIC SCALE
+10.60
T.O.S
ISSUE STATUS
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
FOR TENDER AS BUILT FOR INFO.
6600
7800

7800

7800
4600

4600
30 mm THICKNESS WHITE STONE CLADDING
13950

13950
+6.00
12450

12450

12450
F.F.L
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

REV DATE REVISION DESCRIPTION CKD APR

1650
5400

5400
5850

D D
4650

4650
30 mm THICKNESS DARK
BROWN STONE

3000
CLADDING
450

450

150
30 mm THICKNESS DARK BROWN STONE CLADDING 30 mm THICKNESS DARK BROWN STONE CLADDING 30 mm THICKNESS DARK BROWN STONE CLADDING

E
ELEVATION 04 E

ELEVATION 04 AR-A1-1-204
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

KEY PLAN
NOTES
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
NOTED.
01
AR-703 2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
BRONZE HILAL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &

1786
UNIT WITH
SCREW END EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
3400 THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE


1500

SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER


APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
SEALANT.
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
STRUCTURAL DRAWINGS.
2900

30 mm
THICKNESS
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
DARK OF FLOOR DRAINS AND FLOOR CLEANOUTS .
BROWN 9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
STONE
CLADDING AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
1000

, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM


600

ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND
FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES
7550

C C

0 1 2 4 6 8 10m
30150

30 mm THICKNESS WHITE STONE CLADDING

+13.60
SCALE 1:100 GRAPHIC SCALE
T.O.S
500

ISSUE STATUS
600

FOR REVISION FOR APPROVAL FOR CONSTRUCTION

3500
‫ﺧﺪﻣﺎت‬
3000

SERVICES FOR TENDER AS BUILT FOR INFO.


FR-01
+10.60
T.O.S
200

200
800

800

800
‫ﻣﺼــــــﻠﻰ اﻟﻨﺴــــــﺎء‬
WOMEN PRAYER HALL
30 mm MZ-01
7800

THICKNESS 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.


4600

WHITE
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.
3600

3600

3600
STONE
CLADDING
REV DATE REVISION DESCRIPTION CKD APR
14100

M01
+6.00
F.F.L
300

300

D D
1500

1500

CW 01 CW 02
300

3600
1650

5400
650

‫ﺣــﻮش اﻟﻤﺴــﺠﺪ‬
3600

COURT
3300

3300
30 mm G08 GR-02
G14 G07
THICKNESS

1800
2200

DARK
BROWN
450

STONE
150

150

150

CLADDING

E
SECTION 01 E

SECTION 01 AR-A1-1-301
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

A A

KEY PLAN
NOTES
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE
NOTED.
2. ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR
BEFORE PREPARATION OF SHOP DRAWING.
3. THESE DRAWINGS MUST BE READ IN CONJUNCTION WITH ALL
OTHER ARCHITECTURAL AND ENGINEERING DRAWINGS &
EQUIPMENT DOCUMENTS RELATED TO THE SAME SHEET AND
ANY ITEM ON IT.
4. ALL MASONRY WALLS ( FIRE RATED )MUST BE EXTEND FROM
THE TOP OF THE FLOOR SLAB TO UNDER THE SIDE OF ROOF
(CONCRETE SLAB OR BEAM ) AND SHALL BE SEALED TIGHT TO
THE STRUCTURE ABOVE
5. ALL DOOR OPENINGS IN WALLS ARE TO HAVE PRECAST
REINFORCED CONCRETE LINTELS WITH MIN. 200MM OF
B BEARING ON EITHER END. B

6. ALL OPENINGS IN 1 HOUR WALLS, EXCEPT DOORS, SHALL BE


SEALED TIGHT WITH FIRE RATED, WHICH SHOULD BE EITHER
APPROVED MINERAL WOOL OR INTUMINESCENT FOAM
SEALANT.
7. FOR EXACT OPENINGS SIZE AND LOCATION REFER TO
STRUCTURAL DRAWINGS.
8. REFER TO DRAINAGE DRAWINGS FOR EXACT LOCATION & SIZE
OF FLOOR DRAINS AND FLOOR CLEANOUTS .
9. ARCHITECTURAL ZERO LEVEL IS EQUAL TO +150.50 ON SITE
AND CONTRACTOR SHOULD COORDINATE ALL ROADS LEVELS
, STAIRS , SITE ENTRANCES, AND ANY RELEVANT ITEM

ABBREVIATIONS
FOR ABBREVIATIONS REFER TO DWG. NO. AR00-002

LEGEND
FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES

+13.60
C C
T.O.S 200
0 1 2 4 6 8 10m
600

CW 05

SCALE 1:100 GRAPHIC SCALE


3000

3000
1600

CW 05 CW 05 R01
ISSUE STATUS
2000

+10.60

840
T.O.S
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
FOR TENDER AS BUILT FOR INFO.

2500
2000

1060
1400

3900
1200
4600

4600
1400
‫ﻣﺼــــــﻠﻰ اﻟﻨﺴــــــﺎء‬
WOMEN PRAYER HALL

1400
3300

MZ-01

14100
13600

+6.00 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.

1700
1000
F.F.L
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.

3000
‫ﺣـــﺮم اﻟﻤﺴـــﺠﺪ‬
W1 W1 W1 W1 W1 PRAYER HALL W1 W1 W1 REV DATE REVISION DESCRIPTION CKD APR
1100

1200
1800
GR-01
8600

200
ALUMINUM CANOPY
3000
5400

5400
D D
‫ﺣــﻮش اﻟﻤﺴــﺠﺪ‬

4100
‫ﻏﺮﻓـــﺔ ا ﻣـــﺎم‬ ‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬

3800
IMAM RM 3600 COURT ENTRANCE LOBBY
GR-12 GR-02 GR-07
1200
450

450
150

150
450
150
E
SECTION 02 E

SECTION 02 AR-A1-1-302
01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

MAKKAH

A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
A AR-205 A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900

KEY PLAN
NOTES
‫ﻛﻬﺮﺑـــــــﺎء‬
ELEC. RM
C1 B.O.S GR-09 C1 B.O.S

A1.1 A1.1
X1 X1
1850

1850
A1.1 A1.1
X2 ‫ﺣﻤﺎﻣﺎت‬
TOILETS
X2
GR-08
C3+2.75
ABBREVIATIONS
C2+3.60
CEILING
‫وﺿـــﻮء‬
CODE DESCRIPTION
4700

4700
ABLUTION
GR-13 C1 ACRYLIC PAINT ON CEMENT PLASTER.
B ‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬ C3+2.75 B
ENTRANCE LOBBY C2 ACRYLIC PAINT ON 12 MM THK.GYPSUM BOARD .
GR-11 ‫ﺣﻤﺎﻣﺎت‬
C2+3.60 TOILETS
ACRYLIC PAINT ON 12 MM THK.
A1.1 ‫ﻣﺨﺰن‬ GR-08 A1.1 C3
WEATHERPROOF GYPSUM BOARD .
X3 STORAGE C3+2.75 X3
GR-10
C4 600x600 MM PVC CEILING TILES.
1900

1900
C1 B.O.S
600 x 600 MM PHARMACEUTICAL CEILING(Clean
A1.1 A1.1 C5
Room™ FL panels).
X4 X4
1100

1100
C6 WATER PROOFING PAINT ON CEMENT PLASTER.
A1.1 A1.1
X5 X5 C7 E.S ( EXPOSED STRUCTURE ).
‫ﻏﺮﻓـــﺔ ا ﻣـــﺎم‬
IMAM RM C8 EPOXY PAINT.
GR-12
01 C9 WATER TIGHT CONCRETE.
C1 B.O.S ‫ﺣــﻮش اﻟﻤﺴــﺠﺪ‬ AR-203
4000

4000
C2+3.60 COURT
GR-02 COVE LIGHT
B.O.S ... BOTTOM OF SLAB
C2+3.60 E.S ... EXPOSED STRUCTURE
CEILING FINISH CEILING LEVEL
A1.1 A1.1 C0+00.00
‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬ GIDE LINE
X6 ENTRANCE LOBBY X6
28200

GR-07 LEGEND

27400
01
AR-206 C2+4.10 FOR LEGENDS REFER TO DWG. NO. AR00-002

REFERENCES
4000

4000
C 01 C
AR-204

0 1 2 4 6 8 10m
A1.1 A1.1
SCALE 1:100 GRAPHIC SCALE
X7 X7
1100

1100
A1.1 A1.1 ISSUE STATUS
X8 X8
‫ﺻــــــﺎﻟﺔ ﺗﻮزﻳــــــﻊ‬ FOR REVISION FOR APPROVAL FOR CONSTRUCTION
LOBBY
1900

1900
GR-04 FOR TENDER AS BUILT FOR INFO.
‫ﻣﺼـــــــﻠﻰ ﻛﺒـــــــﻴﺮات‬
A1.1 OLD WOMEN PRAYER HALL C2+3.60 A1.1
X9 GR-03 X9
C2+3.60
‫ﺣﻤﺎﻣﺎت‬
2500

2500
TOILETS
GR-06
A1.1 C3+2.75 A1.1
X10 X10 00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.
2200

2200
REV DATE REVISION DESCRIPTION CKD APR
A1.1 A1.1
X11 X11
1850

1850
D A1.1 A1.1 D
X12 ‫ﺻـــﺎﻟﺔ دﺧـــﻮل‬ X12
ENTRANCE LOBBY
C1 B.O.S GR-04 C2+3.60
3990

3990
A1.1 A1.1
X13 X13
2470

2470
A1.1 A1.1
X14 X14

3250 13950 2350 5950 3400 2700 1300 900 4900


39100

E
GROUND FLOOR REFLECTED CEILING PLAN E
01
AR-201
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

GROUND FLOOR REFLECTED CEILING PLAN AR(A1-1) 401


01 SCALE 1-100

1-100
1 2 3 4 5 6 7
1 2 3 4 5 6 7

MAKKAH

MAKKAH
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 01 Y5 Y6 Y7 Y8 Y9 Y10
AR-202
01
AR-205

A A

39100
3250 13950 2350 5950 3400 2700 1300 900 4900

KEY PLAN
‫ﻣﻜﺘﺒــــــــــﺔ‬
LIBRARY NOTES
C1 B.O.S C2+3.60 MZ-02

A1.1 A1.1
X1 X1
1850

1850
‫ﺣﻤﺎم‬
TOILET
A1.1 MZ-04 A1.1
X2 C3+2.75 X2

ABBREVIATIONS
4700

4700
CEILING
CODE DESCRIPTION
‫ﻏﺮﻓــﺔ ﺣــﺎرس‬
GUARD RM C1 ACRYLIC PAINT ON CEMENT PLASTER.
B MZ-03 B
C2 ACRYLIC PAINT ON 12 MM THK.GYPSUM BOARD .
A1.1 C2+3.60 A1.1
X3 X3 ACRYLIC PAINT ON 12 MM THK.
C3
WEATHERPROOF GYPSUM BOARD .
1900

1900
C4 600x600 MM PVC CEILING TILES.
A1.1 A1.1
X4 X4 C5
600 x 600 MM PHARMACEUTICAL CEILING(Clean
1100

1100
Room™ FL panels).
A1.1 A1.1
X5 X5 C6 WATER PROOFING PAINT ON CEMENT PLASTER.

C7 E.S ( EXPOSED STRUCTURE ).


01 C8 EPOXY PAINT.
AR-203
4000

4000
C9 WATER TIGHT CONCRETE.
‫ﺣـــﺮم اﻟﻤﺴـــﺠﺪ‬ COVE LIGHT
‫ﻣﺼــــــﻠﻰ اﻟﻨﺴــــــﺎء‬
PRAYER HALL B.O.S ... BOTTOM OF SLAB
WOMEN PRAYER HALL
GR-01
A1.1 MZ-01 A1.1 E.S ... EXPOSED STRUCTURE
CEILING FINISH CEILING LEVEL
X6 X6 C0+00.00
28200

C2+8.80 C2+3.60 GIDE LINE

27400
01
AR-206 LEGEND
FOR LEGENDS REFER TO DWG. NO. AR00-002
4000

4000
01
AR-204 REFERENCES
C C

A1.1 A1.1 0 1 2 4 6 8 10m


X7 X7
1100

1100
A1.1 A1.1 SCALE 1:100 GRAPHIC SCALE
X8 X8
ISSUE STATUS
1900

1900
FOR REVISION FOR APPROVAL FOR CONSTRUCTION
A1.1 A1.1 FOR TENDER AS BUILT FOR INFO.
X9 ‫ﺣﻤﺎم‬ X9
TOILET
MZ-05
2500

2500
C3+2.75
A1.1 A1.1
X10 X10
00 DEC 2022 ISSUED FOR TENDER H.I. M.H.
2200

2200
00 NOV 2022 ISSUED FOR APPROVAL H.I. M.H.
A1.1 A1.1
X11 X11 REV DATE REVISION DESCRIPTION CKD APR
‫ﺑﻬـــــﻮ‬
1850

1850
LOBBY
MZ-06 C2+3.60
A1.1 A1.1
D
X12 X12 D
C1 B.O.S
3990

3990
A1.1 A1.1
X13 X13
2470

2470
A1.1 A1.1
X14 X14

3250 13950 2350 5950 3400 2700 1300 900 4900


39100

01
E AR-201 MEZZANINE FLOOR REFLECTED CEILING PLAN
E
A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1 A1.1
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10

MEZZANINE FLOOR REFLECTED CEILING PLAN


01 SCALE 1-100
AR(A1-1) 402

1-100
1 2 3 4 5 6 7

You might also like