Professional Documents
Culture Documents
Name of Work:- C/o Mahila barrack (for 08 occuptions) with attached toilet and SO's Room at BOP Murar of 18 (Now 108 ) BN BSF under
SHQ BSF Jaisalmer (S) FTR Rasthanja .
SLNo Description Qty Unit Rate Amount
2 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and disposal of
surplus excavated soil as directed, within a lead of 50 m.All
kinds of soil.
septic tank SOS 1.00 3.70 2.15 1.50 11.93
11.93 cum 166.40 1985.15
4 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :1:4:8 (1 Cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm
nominal size)
SOS UNDER INTERLOCKING BLOCKS 1.00 61.50 3.79 0.15 34.94
1.00 8.94 23.20 0.15 31.10
1.00 4.67 11.60 0.15 8.12
sos flooring base 6.00 4.50 3.60 0.10 9.72
1.00 14.24 1.20 0.10 1.71
-5.00 1.43 0.15 0.10 -0.11
SOS PLINTH PROTECTION 2.00 17.37 0.90 0.10 3.13
2.00 9.69 0.90 0.10 1.74
septic tank SOS 1.00 3.70 2.15 1.50 11.93
102.28 cum 4478.15 458025.18
19 Add for plaster drip course/ groove in plastered surface or
moulding to R.C.C. projections.
SOS 2.00 17.37 34.74
2.00 11.42 22.84
5.00 4.73 23.65
2.00 2.34 4.68
85.91 metre 34.15 2933.83
20 Half brick masonry with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in superstructure
0.00
above plinth level up to floor V level.Cement mortar 1:4 (1
cement :4 coarse sand)
septic tank SOS 2.00 1.25 1.50 3.75
3.75 sqm 684.20 2565.75
21 Extra for providing and placing in position 2 Nos 6mm dia.
3.75 sqm 56.85 213.00
M.S. bars at every third course of half brick masonry.
22 Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with :Cement mortar 1:6 (1 cement : 6
coarse sand)
septic tank SOS 2.00 3.70 0.45 1.50 5.00
5.00 cum 4326.45 21632.25
29 Providing and fixing ISI marked flush door shutters
conforming to IS: 2202 (Part I) decorative type, core of
block board construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with vertical grains or
cross bands and face veneers on both faces of shutters.35
mm thick including ISI marked Stainless Steel butt hinges
with necessary screws.
SOS 5.00 0.90 2.15 9.68
9.68 sqm 2488.95 24080.59
30 Providing and fixing ISI marked flush door shutters
conforming to IS: 2202 (Part I) decorative type, core of
block board construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with vertical grains or
cross bands and face veneers on both faces of shutters.25
mm thick (for cupboard) including ISI marked nickel plated
bright finished M.S. Piano hinges IS : 3818 marked with
necessary screws.
SOS 5.00 1.22 1.82 1.00 11.10
11.10 sqm 2129.10 23633.01
31 Providing and fixing curtain rods of 1.25 mm thick
chromium plated brass plate, with two chromium plated
brass brackets fixed with C.P. brass screws and wooden
plugs, etc., wherever necessary complete :25 mm dia
SOS 5.00 1.25 6.25
5.00 0.80 4.00
5.00 1.10 5.50
5.00 1.20 6.00
almirah 5.00 0.70 3.50
25.25 metre 463.85 11712.21
32 Providing and fixing M.S. grills of required pattern in frames
of windows etc. with M.S. flats, square or round bars etc.
including priming coat with approved steel primer all
complete.Fixed to steel windows by welding
SOS 5.00 0.90 9.00 1.120 45.36
5.00 0.60 9.00 1.120 30.24
passage w 2.00 1.20 9.00 1.120 24.19
ventilators 5.00 0.60 3.00 1.120 10.08
109.87 kg 104.65 11497.90
34 Providing and fixing ISI marked oxidised M.S. tower bolt
black finish, (Barrel type) with necessary screws etc.
complete :200x10 mm
SOS 5.00 2.00 10.00
10.00 each 51.05 510.50
35 Providing and fixing oxidised M.S. hasp and staple (safety
type) conforming to IS : 363 with necessary screws etc.
complete :150 mm
SOS 5.00 2.00 10.00
10.00 each 23.05 230.50
36 Providing and fixing oxidised M.S. casement stays (straight
peg type) with necessary screws etc. complete.250 mm
weighing not less than 150 gms
SOS 5.00 2.00 10.00
10.00 each 26.85 268.50
37 Providing and fixing aluminium sliding door bolts, ISI
marked anodised (anodic coating not less than grade AC 10
as per IS : 1868), transparent or dyed to required colour or
shade, with nuts and screws etc. complete :250x16 mm
SOS 5.00 1.00 5.00
5.00 each 189.20 946.00
38 Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS
: 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :250x10 mm
SOS 5.00 2.00 10.00
10.00 each 88.10 881.00
39 Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS
: 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :200x10 mm
SOS 5.00 2.00 10.00
10.00 each 76.15 761.50
40 Providing and fixing aluminium tower bolts, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS
: 1868 ) transparent or dyed to required colour or shade, with
necessary screws etc. complete :150x10 mm
SOS 5.00 2.00 10.00
10.00 each 64.30 643.00
41 Providing and fixing aluminium handles, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS
: 1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :125 mm
SOS 5.00 2.00 10.00
18.00 2.00 36.00
46.00 each 51.10 2350.60
42 Providing and fixing aluminium hanging floor door stopper,
ISI marked, anodised (anodic coating not less than grade AC
10 as per IS : 1868) transparent or dyed to required colour
and shade, with necessary screws etc. complete.Twin rubber
stopper
SOS 5.00 1.00 5.00
MH 5.00 1.00 5.00
10.00 each 38.00 380.00
43 Providing and fixing magnetic catcher of approved quality in
cupboard / ward robe shutters, including fixing with
necessary screws etc. complete.Double strip (horizontal
type)
SOS 5.00 2.00 10.00
10.00 each 21.50 215.00
44 Providing and fixing Fiber Glass Reinforced plastic (FRP)
Door Frames of cross-section 90 mm x 45 mm having single
rebate of 32 mm x 15 mm to receive shutter of 30 mm
thickness .The laminate shall be moulded with fire resistant
grade unsaturated polyester resin and chopped mat. Door
frame laminate shall be 2 mm thick and shall be filled with
suitable wooden block in all the three legs. The frame shall
be covered with fiber glass from all sides. M.S. stay shall be
provided at the bottom to steady the frame.
SOS 5.00 4.95 24.75
24.75 metre 415.50 10283.63
45 Providing and fixing to existing door frames.30 mm thick
Glass Fibre Reinforced Plastic (FRP) panelled door shutter
of required colour and approved brand and manufacture,
made with fire - retardant grade unsaturated polyester resin,
moulded to 3 mm thick FRP laminate for forming hollow
rails and styles, with wooden frame and suitable blocks of
seasoned wood inside at required places for fixing of
fittings, cast monolithically with 5 mm thick FRP laminate
for panels conforming to IS: 14856, including fixing to
frames.
SOS 5.00 0.71 2.10 7.46
7.46 metre 2187.35 16306.69
47 Providing and fixing factory made ISI marked steel glazed
doors, windows and ventilators, side /top /centre hung, with
beading and all members such as F7D, F4B, K11 B and K12
B etc. complete of standard rolled steel sections, joints
mitred and flash butt welded and sash bars tenoned and
riveted, including providing and fixing of hinges, pivots,
including priming coat of approved steel primer, but
excluding the cost of other fittings, complete all as per
approved design, (sectional weight of only steel members
shall be measured for payment).Fixing with 15x3 mm lugs
10 cm long embedded in cement concrete block 15x10x10
cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size)
SOS 5.00 2.00 1.20 2.28 27.36
5.00 2.00 0.85 2.28 19.38
5.00 4.00 1.16 2.28 52.90
5.00 4.00 0.38 2.28 17.33
5.00 2.00 1.20 2.28 12.00
5.00 2.00 0.58 2.28 5.80
2.00 2.00 1.20 2.28 4.80
2.00 2.00 1.18 2.28 4.72
2.00 4.00 1.16 2.28 9.28
2.00 4.00 0.38 2.28 3.04
V 5.00 2.00 0.60 1.42 6.00
5.00 2.00 0.58 1.42 5.80
168.40 kg 113.60 19130.69
48 Extra for providing and fixing steel beading of size 10 x 10 x
1.6 mm (box type), approved shape and section with screws
instead of glazing clips and metal sash putty, in steel doors,
windows, ventilators and composite units.
SOS 5.00 4.00 1.20 24.00
5.00 16.00 0.30 24.00
5.00 2.00 0.60 6.00
5.00 4.00 1.20 24.00
2.00 4.00 1.20 9.60
2.00 8.00 0.40 6.40
5.00 0.60 0.90 2.70
5.00 4.00 0.60 12.00
108.70 metre 38.35 4168.65
49 Providing and fixing T-iron frames for doors, windows and
ventilators of mild steel Tee-sections, joints mitred and
welded, including fixing of necessary butt hinges and screws
and applying a priming coat of approved steel primer.Fixing
with 15x3 mm lugs 10 cm long embedded in cement
concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size)
SOS 6.00
6.00 8634.10 51804.60
110 Making connection of drain or sewer line with existing
manhole including breaking into and making good the walls,
floors with cement concrete 1:2:4 mix (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) cement
SOS 5.00
plastered on both sides with cement mortar 1:3 (1 cement : 3
coarse sand), finished with a floating coat of neat cement
and making necessary channels for the drain etc. complete
:For pipes 100 to 250 mm diameter
MH 3.00
8.00 each 391.15 3129.20
111 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks and S.W. drain
pipe 100 mm diameter, 1.8 m long complete as per standard
designWith common burnt clay F.P.S. (non modular) bricks
of class designation 7.5
SOS 1.00
1.00 each 20681.55 20681.55
112 Grading roof for water proofing treatment withCement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone 1.00 15.54 9.69 0.05 7.53
aggregate 20 mm nominal size)
SOS septic tank 1.00 3.70 2.15 0.05 0.40
7.93 cum 5583.80 44279.53
70 6 mm plaster on cement concrete or reinforced cement
concrete work with white cement based polymer modified
self curing mortar of approved make as per the direction of
Engineer-In-Charge.
SOS septic tank 1.00 3.70 2.15 7.96
7.96 sqm 146.45 1165.74
EX 1 Jaisalmer stone slab flooring over 20 mm (average)
thick base laid over and jointed with grey cement
slurry mixed with pigment to match the shade of the
slab, including rubbing and polishing complete with
base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
:
SOS W SILL 9.00 0.90 0.25 2.03
2.00 1.20 0.25 0.60
5.00 0.60 0.25 0.75
AL 5.00 1.45 0.45 3.26
5.00 1.45 0.45 3.26
SOS PLINTH PROTECTION 2.00 17.37 0.90 31.27
2.00 9.69 0.90 17.44
58.61 sqm 1300.00 76193.00
E2 Providing wood work in frames of doors, windows,
clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash
fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately). Sal wood