Project:

BLOK TAMBAHAN PUSAT


Calculation Sheet KHIDMAT AGENSI ANTIDADAH
KEBANGSAAN
(PKAADK) DAERAH JASIN
Title: Step (2) : Sizing of sediment basin Design by: VNA
Date: 6/7/2011
REF. CALCULATION REMARK

MSMA e) SIZING Of EMERGENCY SPILLWAY


2000

Sec 39.7.6© The emergency spillway must be designed for a 10 year ARI flood
The sill level must be set a minimum 300 mm above the basin top water level.

To simplify the calculations, the following assumptions are made:


ꞏ assume riser pipe flow is orifice flow through the top of the pipe only
ꞏ riser pipe head is 300 mm, i.e. the height between the top of the pipe and the spillway
crest level

Qspillway = Q10 – Qriser

Q10 = 0.06 m3/s


1/2
Eq.20.2; Qriser = Cd Ao (2g Ho)

Orifice discharge coefficient Cd = 0.62 Cd


Gravity g= 9.81 m/s²
Orifice size Do = 50 mm or 0.05 m Do
Efective head from ctr Ho = 0.3 m Ho
opening
Outlet riser size D= 300 mm or 0.3 m
so; Ao = 0.07071
Qriser = 0.106 m³/s

so that; Qspillway = -0.050 m³/s

Eq.20.9; Qspillway = CSP . B. Hp1.5

use trial & error;


Spillway basewidth, B= 1 m
Chart 20.2; Spillway discharge coef. CSP = 1.57
Effective spillway head, HP = 0.2 m

so that; Qspillway = 0.140 m³/s > -0.050 m³/s OK!

Therefore, the total basin depth including the spillway is 1.20 m


(y1 + y2 + sill level + Hp)

Confidential 25/5/2022 Silt Trap (4)1 of 1