CorrTran MV
141
approx. 31
26
Thread for direct
mounting only
51
¾ NPT compression thread
CMCM
Ø 19
32
Function
24 V DC
alternatively
US-HI-321
HART-
Modem
or
communicator
Communication
resistance (> 250 Ω)
CorrTran MV 1 2 3
I+ I- GND
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 1
Technical data Corrosion Monitoring CorrTran MV
CMCM
General specifications
Equipment architecture 4 ... 20 mA output with HART protocol
Series CorrTran MV
Input characteristics
Measured variable Corrosion update time:
- general, localized and conductance: 21 minutes
- general and conductance: 4 minutes
- local and conductance: 17 minutes
Output characteristics
Output signal 4 ... 20 mA with HART protocol
Signal on alarm error information can be accessed via the following interfaces:
- current output (configurable)
- digital interface
Output damping 0, 1, 2, 5, 10, 20, 50 s
Load minimum load for HART communication: 250 Ω
Auxiliary energy
Electrical connection 4 ... 20 mA with HART, 2-wire
Supply voltage 2-wire HART (standard):
- current consumption 4 ... 22.5 mA
- min. terminal voltage 11 V (at 20 mA) without alarm / (at 22.5 mA) with alarm
- max. terminal voltage 30 V
Current consumption 4 ... 22.5 mA
Connectable load max. load at 24 V DC: 575 Ω with high alarm/650 Ω without high alarm
Terminal assignment see section electrical connection
Performance characteristics
Maximum measured error Excitation voltage < 0.05% of full span
Corrosion current measurement <0.2% of full span
Configuration The adjustments and scaling can be done using a handheld terminal or the operating software.
General corrosion rate:
- range: max. 1000 mils/year, default 40 mils/year
- Zero/span adjustments available with HART
Localized corrosion (pitting) factor:
- default: 0.0 ... 1.0
- low pitting: 0.0 ... 0.3
- high pitting: 0.3 ... 1.0
Alarm configuration output signal when measurement is out of range:
- none
- high (22.5 mA), autoreset (default)
- high (22.5 mA), manual reset
Factory settings B value (Stern Geary value): 25.6 mV
K value (corrosion constant): 11800 (2e- in reaction)
Response time depends on configuration
- min. 4 min
- max. - 21 min
Operating conditions
Installation conditions see Technical Information
Ambient conditions
Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
Process conditions
Process temperature stainless steel probe:
- direct mounting: max. 121 °C (250 °F)
Release date 2011-05-20 19:51 Date of issue 2011-05-21 T38356_ENG.xml
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 2
Technical data Corrosion Monitoring CorrTran MV
CMCM
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 3
Technical data Corrosion Monitoring CorrTran MV
CMCM
Dimensions
Ø 28
Extended cable for 96 96
remote mounting
length
1.8 or 3.6 m
76
80
160
¾ NPT
Ø 18
19
76
Direct mounting
Remote mounting
Ø 29
Ø 60
26
29 20
70
min.
25.4 min.
Thread for direct Thread for direct 50.4 Thread for direct
mounting only mounting only mounting only
Thickness
ANSI B 16.5
51 51 standard
51
Ø 19 Ø 19 Ø 19
Adjustable epoxy glass Adjustable stainless steel Fixed stainless steel Stainless steel probe
probe and electrode** probe and electrode** probe and electrode with fixed flange
* Standard lengths are 204 mm (8"), 305 mm (12"), 458 mm (18"), 611 mm (24") and 763 mm (30").
Minimum length is 178 mm (7") and the maximum length is 763 mm (30").
Insertion lengths for fixed probes are specified in 5 mm or 0.2" increments.
Release date 2011-05-20 19:51 Date of issue 2011-05-21 T38356_ENG.xml
** All adjustable probes include a safety retaining bracket which must be used in all pressurized applications.
Additional information
Operation of CorrTran MV
CorrTran MV multivariable output via HART allows monitoring of general corrosion, localized corrosion, and conductivity using
one transmitter. To utilize all three variables, a HART-compatible device must be used. If none is available, the US-HIM interface
unit will integrate the three variables into separate, independent 4 mA ... 20 mA outputs. Using HART, the primary variable "PV",
the secondary variable "SV", and the tertiary variable "TV" are available, and the user has the option of making either general
or localized corrosion as the primary variable. Conductance cannot be changed and always is the tertiary variable.
Because of the unique algorithm of the calculation method, the Stern-Geary B value is automatically updated during every
measurement cycle. No calibrating in the field or updating this value is required. Through the HART signal, the updated B value
can be acquired.
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 4
Technical data Corrosion Monitoring CorrTran MV
CMCM
Conductance
Measurement: Siemens
Range: not adjustable
Measurement cycle
The measurement cycle is the amount of time needed to calculate the corrosion rates and output through the device. This
measurement cycle varies depending on the types of corrosion being measured and can be user set:
• general, localized, and conductance: 21 minutes
• general and conductance: 4 minutes
• localized and conductance: 17 minutes
Adjustment for these variables can be achieved through any HART-compatible device using the CorrTran MV DD or with
PACTwareTM: Pepperl+Fuchs latest generation of configuration software that makes it easy to program equipment from
Pepperl+Fuchs via HART.
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 5
Technical data Corrosion Monitoring CorrTran MV
CMCM
Accessories
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 6
Technical data Corrosion Monitoring CorrTran MV
CMCM
C M C M – – – A 2 I H – –
* This information is required for all fixed probes. Insertion length includes 1.25" standard electrode length.
Release date 2011-05-20 19:51 Date of issue 2011-05-21 T38356_ENG.xml
** Probe length does not include 1.25" standard electrode length. Probe length is ≥ 2" plus insertion length.
*** Other process connections are available on request.
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany