You are on page 1of 4

List of Abbreviations for UE Systems’ DMS Software

Modules:

STM – Stethoscope Module


SCM – Scanning Module
RAS – Remote Access Sensor
RMT – Remote Magnetic Transducer
LRM – Long Range Module
UWC – Ultra Waveform Concentrator
FLX – Flexible Airborne Module or Teleflex Extendible Probe
OTH – Any other module that may be used or introduced later

The following may be changed Under “File” “Configure Lists”

Generic:
Test Results:
BAD- Failed
CHK- Recheck or check with another method
NE – Not Entered
Ok- Good, no action needed

Bearing:
Test Results
INP -Inspect again, another method possibly
LUB -Lubrication Needed
NE – Not Entered
Other- Other
REP – Replace
Type (of bearing)
NE – Not Entered
Grease Type (What type of grease is being used)
Mineral Base
Polyurea
Synthetic
Grease Viscosity (What viscosity of Grease is being used)
100
150
220
460

TRAINING THE
WORLD
One Plant at a Time
Electrical:
Test Result
ARC – Item is Arcing
COR – Item is producing Corona
MEC – Item is mechanical vibrating, not producing a discharge
NE – Not Entered
NIS – Not In Service
OK – Item is Good, No Action Needed
OTH – Other
PD – Item is producing Partial Discharge
TRK – Item is producing Tracking
Location
NE – Not Entered
Item Component
BSR - Busbar
DCT - Duct
INS – Insulator
NE – Not Entered
SGR – Switch Gear
TER – Terminal
TFR – Transformer
Voltage – Choose voltage of Component Scanned

Leak:
Test Result
CHK – Check again or with another method
LEK – Item is Leaking
NE – Not Entered
OK – Item is not Leaking
Application
ARGN – Argon
CAIR – Compressed Air
NE – Not Entered
NITR – Nitrogen
OTHR- Other types of Gasses or Applications
Distance
The distance the decibel reading was taken.
This distance should always be 15 inches from tip of rubber focusing probe to leak site if
using The Compressed Gas Loss Calculations from UE Systems, Inc.

TRAINING THE
WORLD
One Plant at a Time
Leak: (Continued)

Distance (metric)
The distance the decibel reading was taken.
This distance should always be 31 centimeters from tip of rubber focusing probe to leak
site if using The Compressed Gas Loss Calculations from UE Systems, Inc.

Steam:
Test Result
BLW – The trap is blowing by meaning it is not cycling and in the open/exhaust position
LEK – Trap is Leaking but still cycling
NE – Not Entered
NIS – Trap is Not In Service
OK – Trap is Functioning Properly
OTH – Other Result
PLG – Trap is plugged, no steam or condensate is moving through trap
SIZ – Sizing Issue to Application
Manufacturer
ARM- Armstrong
BES – Bestobell
NE – Not Entered
NIC – Nicholson
SAR – Spirex Sarco
YAR – Yarborough
Model
NE – Not Entered
OTH – Other Than Listed
Application
AH – Air Handler
HE – Heat Exchange
NE – Not Entered
PRO – Process Steam
RAD – Radiator
SM – Steam Main
TR – Trace Steam
Model
NE – Not Entered
OTH – Other Than Listed
Operational Type
FT – Float and Thermostatic (F&T)
IB – Inverted Bucket
NE – Not Entered
TD – Thermodynamic
TH - Thermostatic

TRAINING THE
WORLD
One Plant at a Time
Steam: (Continued)

Pipe Size
The diameter of the pipe in standard measurement
Pipe Size
The diameter of the pipe in metric measurement
Orifice Size
The diameter of the orifice in the steam trap in standard measurement
Orifice Size (metric)
The diameter of the orifice in the steam trap in metric measurement

Valve:
Type
BFY -Butterfly Valve
BLL – Ball Valve
GTE – Gate Valve
NE – Not Entered
Other – Another type of valve
Application
NE – Not Entered
UNK – Unknown Application for the valve
Pipe Size
The diameter of the pipe in standard measurement
Pipe Size
The diameter of the pipe in metric measurement

TRAINING THE