CASE - 1
Hanging load (w) = 10 TON
100 KN
Ultimate Load ( By considering 1.5 safety factor ) (W) = 150 KN
CASE - 2
Hanging load (w) = 8 TON
80 KN
Ultimate Load ( By considering 1.5 safety factor ) (W) = 120 KN
CASE - 3
Hanging load (w) = 5 TON
50 KN
Ultimate Load ( By considering 1.5 safety factor ) (W) = 75 KN
CASE - 4
Hanging load (w) = 3 TON
30 KN
Ultimate Load ( By considering 1.5 safety factor ) (W) = 45 KN
CASE - 5
Hanging load (w) = 2 TON
20 KN
Ultimate Load ( By considering 1.5 safety factor ) (W) = 30 KN
Required welding length (l) = 31.746032 MM
Ultimate welding length requirement for Dynamic Load (L) = 158.73016 MM