You are on page 1of 1

Stud Back to back studs

10g or 12 g screws,
as per Engineering 10g or 12 g screws,
as per Engineering
Anchor and holdown
as per Engineering Anchor and holdown
as per Engineering

Bottom Plate Extra 10g screw


to each stud
Folded Plate

Large Washer Load bearing walls


Holdown Bracket

Stud Stud

10g or 12 g screws,
as per Engineering

Anchor and holdown


Concrete Nail with
as per Engineering
Washer

Bottom Plate
ma
x. 60m
Bottom Plate
m

Non-Load bearing walls


Holdown Bracket

Note: concrete anchors


can be used instead of
Note: Consult with Engineer concrete nails
for each connection FC-W14: Wall Panel to Foundation Connection

07-12-2018 RGA
23/40
TYPICAL DETAILS FRAME STRUCTURES 02-11-2018
1 : 75