You are on page 1of 66

Footing Design: Design Calculation Page 1 of 66

FOOTING DESIGN CALCULATIONS


Project Name : IFSU
Client Name : IFSU
Engineer Name : ANMJR
Design File : C:\Users\63917\Documents\ANMJR\PROJECTS\ANMJR-2023-
IFSU\RCDC\FOOTING.rcdx
Analysis File : C:\Users\63917\Documents\ANMJR\PROJECTS\ANMJR-2023-
IFSU\STAAD ANALYSIS\IFSU.std
Analysis Last Modified : 19/01/2023 10:42:40 pm

Definitions:
1. A = Plan area of footing base in sqmm
2. Ast (min) = Area of longitudinal reinforcement as per code cl. 7.12.2.1
in sqmm
3. Ast Prv = Area of tensile reinforcement provided in sqmm
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment
and minimum % steel provided by user and as per code cl
7.12.2.1 in sqmm
5. Av = Area of shear reinforcement required in sqmm
6. AvPrv = Area of shear reinforcement provided in sqmm
7. A1 = Bearing area of footing at slope of 1:2 in sqmm
8. A2 = C/s Area of column in sqmm
9. B = Width of footing base in mm
10. Beff = Effective width of footing in mm
11. Boff = Footing offset along B in mm
12. BoffB = Footing offset along B above column in plan
13. BoffT = Footing offset along B below column in plan
14. B1 = Width of sloped footing at top in mm
15. ColOff = Column offset in sloped footing in mm
16. D = Depth of footing in mm
17. d = Effective Depth of footing in mm
18. Dfd = Depth of founding layer in m
19. Dw = Ground water level in m
20. Ec = Modulus of elasticity of concrete in N/sqmm
21. Es = Modulus of elasticity of steel in N/sqmm
22. Foss = Safety factor against sliding
23. Fosu = Safety factor against uplift
24. Fst = Stress in steel in N/sqmm
25. F'c = Characteristic strength of concrete in N/sqmm
26. L = Length of footing base in mm
27. Leff = Effective length of footing in mm
28. Loff = Footing offset along L in mm
29. LoffL = Footing offset along L on left side of column

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 2 of 66

30. LoffR = Footing offset along L on right side of column


31. L1 = Length of sloped footing at top in mm
32. Mx = Bending Moment along column D in kN-m
33. Mex = Eccentricity moment along column D
34. Mxx = Total Bending Moment along column D (Mx + Mex)
35. My = Bending Moment along column B in kN-m
36. Mey = Eccentricity moment along column B
37. Myy = Total Bending Moment along column B (My + Mey)
38. Muy = Factored moment along column B in kN-m
39. Mux = Factored moment along column D in kN-m
40. Netdown = Net downward load in kN
41. OB = Maximum permissible offset on bottom side of column
42. OL = Maximum permissible offset on left side of column
43. OR = Maximum permissible offset on right side of column
44. OT = Maximum permissible offset on top side of column
45. P = Axial load for footing sizing in kN
46. P1 = Soil pressure at corner 1 in kN/sqm
47. P2 = Soil pressure at corner 2 kN/sqm
48. P3 = Soil pressure at corner 3 kN/sqm
49. P4 = Soil pressure at corner 4 kN/sqm
50. Ntot = Design vertical load on footing in kN
51. q = Surcharge Load in kN/sqm
52. sp = Spacing Between bars at outer most layer in mm
53. SPu = Upward Soil Pressure in kN/sqm
54. SPuL = Upward Soil Pressure from left
55. SPuR = Upward Soil Pressure from right
56. SPuB = Upward Soil Pressure from bottom
57. SPuT = Upward Soil Pressure from top
58. Temp1 = Peak Hydration temperature in Degree
59. Temp2 = Seasonal Temperature Variations in Degree
60. Vs Capacity = Shear strength capacity of provided shear reinforcement
kN
61. Vu = Design shear force in kN
62. Vus = Strength of shear reinforcement in kN
63. Vx = Shear along major axis in kN
64. Vy = Shear along minor axis in kN
65. Waterpr = Upward water pressure in kN/sqm
66. Waterup = Upward force due to water in kN/sqm
67. WFoot = Add. Wt. due to difference in concrete and soil density in
kN
68. WFootc = Weight of footing and column with concrete density in
kN
69. WSoil = Weight of soil covering footing area in kN
70. Zx =

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 3 of 66

Section modulus of footing base along L in mm3


71. Zy = Section modulus of footing base along B in mm3
72. Vs = Nominal shear strength provided by shear reinforcement,
in KN
73. Vc = Nominal shear strength provided by concrete in kN
74. Cx = Width of column in mm
75. Cy = Length of Column in mm
76. Pcr(axial) = Design pressure at the critical section kN/sqm
77. Φ = Strength reduction factor in shear
78. Φ1 = Strength reduction factor in concrete bearing
79. Φ1Pnb = Bearing strength of column in kN

Code References:
ACI  318M:2011
Sr.No. Item Clause / Table
1. Ptmax : 10.3.5
2. Ptmin : 7.12.2.1/10.5.4
3. Vc : 11.11.2.1
4. Av : 11.4.7.2
5. Max Stirrup Spacing : 11.4.5.1
6. Vs : 11.4.7.9

Design Code : ACI 318M - 2011


Footing No : FC1
Column No : C1 ( 300mm X 300mm)
Analysis No : 54

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 4 of 66

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1000mm X 1000mm X 300mm
Effective Self Weight = 7.50 KN

Offset Along L (Loff) = 350 mm


Offset Along B (Boff) = 350 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 154.47 kN
P = Pcomb + Effective Self Weight x 0.9
P = 161.22 kN
Mx = 7.75 kNm
My = -1.71 kNm
P/A = 161.22 kN/sqm
Mx/Zx = 46.49 kN/sqm
My/Zy = -10.28 kN/sqm
Maximum Soil Pressure = 217.98 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 154.47 kN
P = Pcomb + Effective Self Weight x 0.9
P = 161.22 kN
Mx = 7.75 kNm
My = -1.71 kNm
P/A = 161.22 kN/sqm
Mx/Zx = 46.49 kN/sqm
My/Zy = -10.28 kN/sqm
Minimum Soil Pressure = 104.45 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 5 of 66

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
Mux = 12.05 kNm
Muy = -2.66 kNm
P/A = 240.28 kN/sqm
Mx/Zx = 72.31 kN/sqm
My/Zy = -15.99 kN/sqm

Deff = 217 mm
Beff = 1000 mm
SPu = 328.59 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 20.13 kNm
Ast Rqd = 825 sqmm
Ast (min) = 825 sqmm
Ast Prv = 5 - #16 @ 250
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
Mux = 12.05 kNm
Muy = -2.66 kNm
P/A = 240.28 kN/sqm
Mx/Zx = 72.31 kN/sqm
My/Zy = -15.99 kN/sqm

Deff = 201 mm
Leff = 1000 mm
SPu = 328.59 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 20.13 kNm
Ast Rqd = 825 sqmm
Ast (min) = 825 sqmm
Ast Prv = 5 - #16 @ 250
= 1005 sqmm
Distributed Across Total Length

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 6 of 66

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
Mux = 12.05 kNm
Muy = -2.66 kNm
P/A = 240.28 kN/sqm
Mx/Zx = 72.31 kN/sqm
My/Zy = -15.99 kN/sqm

Deff = 217 mm
Beff = 1000 mm
SPu = 328.59 kN/sqm
Vu = SPu X (Loff - d) X B
= 43.70 kN
φVc = 132.35 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
Mux = 12.05 kNm
Muy = -2.66 kNm
P/A = 240.28 kN/sqm
Mx/Zx = 72.31 kN/sqm
My/Zy = -15.99 kN/sqm

Deff = 201 mm
Leff = 1000 mm
SPu = 328.59 kN/sqm
Vu = SPu X (Boff - d) X L
= 48.96 kN
φVc = 122.59 kN
Vu < φVc

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 7 of 66

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
Mux = 12.05 kNm
Muy = -2.66 kNm
P/A = 240.28 kN/sqm
Mx/Zx = 72.31 kN/sqm
My/Zy = -15.99 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 328.59 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 243.46 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 240.28 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1 sqm
A1 > Base Area
Thus, A1 = 1
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.3333
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 8 of 66

Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC2
Column No : C2 ( 300mm X 300mm)
Analysis No : 53

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1250mm X 1250mm X 300mm
Effective Self Weight = 11.72 KN

Offset Along L (Loff) = 475 mm


Offset Along B (Boff) = 475 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 252.60 kN
P = Pcomb + Effective Self Weight x 0.9
P = 263.15 kN
Mx = -4.17 kNm
My = -1.8 kNm
P/A = 168.41 kN/sqm
Mx/Zx = -12.82 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 9 of 66

My/Zy = -5.52 kN/sqm


Maximum Soil Pressure = 186.76 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 252.60 kN
P = Pcomb + Effective Self Weight x 0.9
P = 263.15 kN
Mx = -4.17 kNm
My = -1.8 kNm
P/A = 168.41 kN/sqm
Mx/Zx = -12.82 kN/sqm
My/Zy = -5.52 kN/sqm
Minimum Soil Pressure = 150.07 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
Mux = -6.49 kNm
Muy = -2.8 kNm
P/A = 251.48 kN/sqm
Mx/Zx = -19.95 kN/sqm
My/Zy = -8.59 kN/sqm

Deff = 217 mm
Beff = 1250 mm
SPu = 280.01 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 39.49 kNm
Ast Rqd = 1031 sqmm
Ast (min) = 1031 sqmm
Ast Prv = 6 - #16 @ 250
= 1206 sqmm
Distributed Across Total Width

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 10 of 66

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
Mux = -6.49 kNm
Muy = -2.8 kNm
P/A = 251.48 kN/sqm
Mx/Zx = -19.95 kN/sqm
My/Zy = -8.59 kN/sqm

Deff = 201 mm
Leff = 1250 mm
SPu = 280.01 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 39.49 kNm
Ast Rqd = 815 sqmm
Ast (min) = 1031 sqmm
Ast Prv = 6 - #16 @ 300
= 1206 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
Mux = -6.49 kNm
Muy = -2.8 kNm
P/A = 251.48 kN/sqm
Mx/Zx = -19.95 kN/sqm
My/Zy = -8.59 kN/sqm

Deff = 217 mm
Beff = 1250 mm
SPu = 280.01 kN/sqm
Vu = SPu X (Loff - d) X B
= 90.30 kN
φVc = 160.95 kN
Vu < φVc

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 11 of 66

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
Mux = -6.49 kNm
Muy = -2.8 kNm
P/A = 251.48 kN/sqm
Mx/Zx = -19.95 kN/sqm
My/Zy = -8.59 kN/sqm

Deff = 201 mm
Leff = 1250 mm
SPu = 280.01 kN/sqm
Vu = SPu X (Boff - d) X L
= 95.90 kN
φVc = 150.22 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
Mux = -6.49 kNm
Muy = -2.8 kNm
P/A = 251.48 kN/sqm
Mx/Zx = -19.95 kN/sqm
My/Zy = -8.59 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 280.01 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 12 of 66

= 364.98 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 392.93 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.56 sqm
A1 > Base Area
Thus, A1 = 1.56
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 4.1633
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC3
Column No : C3 ( 300mm X 300mm)
Analysis No : 45

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 13 of 66

Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1050mm X 1050mm X 300mm
Effective Self Weight = 8.27 KN

Offset Along L (Loff) = 375 mm


Offset Along B (Boff) = 375 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 189.58 kN
P = Pcomb + Effective Self Weight x 0.9
P = 197.02 kN
Mx = -0.97 kNm
My = -2.19 kNm
P/A = 178.7 kN/sqm
Mx/Zx = -5.04 kN/sqm
My/Zy = -11.34 kN/sqm
Maximum Soil Pressure = 195.08 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 189.58 kN
P = Pcomb + Effective Self Weight x 0.9
P = 197.02 kN
Mx = -0.97 kNm
My = -2.19 kNm
P/A = 178.7 kN/sqm
Mx/Zx = -5.04 kN/sqm
My/Zy = -11.34 kN/sqm
Minimum Soil Pressure = 162.33 kN/sqm
> 0

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 14 of 66

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
Mux = -1.51 kNm
Muy = -3.4 kNm
P/A = 267.48 kN/sqm
Mx/Zx = -7.83 kN/sqm
My/Zy = -17.64 kN/sqm

Deff = 217 mm
Beff = 1050 mm
SPu = 292.95 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 21.63 kNm
Ast Rqd = 866 sqmm
Ast (min) = 866 sqmm
Ast Prv = 5 - #16 @ 265
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
Mux = -1.51 kNm
Muy = -3.4 kNm
P/A = 267.48 kN/sqm
Mx/Zx = -7.83 kN/sqm
My/Zy = -17.64 kN/sqm

Deff = 201 mm
Leff = 1050 mm
SPu = 292.95 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 21.63 kNm
Ast Rqd = 866 sqmm
Ast (min) = 866 sqmm
Ast Prv = 5 - #16 @ 265
= 1005 sqmm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 15 of 66

Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
Mux = -1.51 kNm
Muy = -3.4 kNm
P/A = 267.48 kN/sqm
Mx/Zx = -7.83 kN/sqm
My/Zy = -17.64 kN/sqm

Deff = 217 mm
Beff = 1050 mm
SPu = 292.95 kN/sqm
Vu = SPu X (Loff - d) X B
= 48.60 kN
φVc = 137.11 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
Mux = -1.51 kNm
Muy = -3.4 kNm
P/A = 267.48 kN/sqm
Mx/Zx = -7.83 kN/sqm
My/Zy = -17.64 kN/sqm

Deff = 201 mm
Leff = 1050 mm
SPu = 292.95 kN/sqm
Vu = SPu X (Boff - d) X L
= 53.52 kN
φVc = 127.00 kN

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 16 of 66

Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
Mux = -1.51 kNm
Muy = -3.4 kNm
P/A = 267.48 kN/sqm
Mx/Zx = -7.83 kN/sqm
My/Zy = -17.64 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 292.95 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 247.08 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 294.9 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.1 sqm
A1 > Base Area
Thus, A1 = 1.1
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.496
Thus, Modification Factor = 2
Φ1 = 0.65

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 17 of 66

Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area


= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC4
Column No : C4 ( 300mm X 300mm)
Analysis No : 44

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 900mm X 900mm X 300mm
Effective Self Weight = 6.08 KN

Offset Along L (Loff) = 300 mm


Offset Along B (Boff) = 300 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 112.65 kN
P = Pcomb + Effective Self Weight x 0.9
P = 118.12 kN
Mx = -2.07 kNm
My = -1.85 kNm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 18 of 66

P/A = 145.82 kN/sqm


Mx/Zx = -17.06 kN/sqm
My/Zy = -15.2 kN/sqm
Maximum Soil Pressure = 178.08 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 112.65 kN
P = Pcomb + Effective Self Weight x 0.9
P = 118.12 kN
Mx = -2.07 kNm
My = -1.85 kNm
P/A = 145.82 kN/sqm
Mx/Zx = -17.06 kN/sqm
My/Zy = -15.2 kN/sqm
Minimum Soil Pressure = 113.57 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
Mux = -3.22 kNm
Muy = -2.87 kNm
P/A = 216.34 kN/sqm
Mx/Zx = -26.53 kN/sqm
My/Zy = -23.65 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 266.51 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 10.79 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300
= 804 sqmm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 19 of 66

Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
Mux = -3.22 kNm
Muy = -2.87 kNm
P/A = 216.34 kN/sqm
Mx/Zx = -26.53 kN/sqm
My/Zy = -23.65 kN/sqm

Deff = 201 mm
Leff = 900 mm
SPu = 266.51 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 10.79 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300
= 804 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
Mux = -3.22 kNm
Muy = -2.87 kNm
P/A = 216.34 kN/sqm
Mx/Zx = -26.53 kN/sqm
My/Zy = -23.65 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 266.51 kN/sqm
Vu = SPu X (Loff - d) X B
= 19.91 kN

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 20 of 66

φVc = 119.64 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
Mux = -3.22 kNm
Muy = -2.87 kNm
P/A = 216.34 kN/sqm
Mx/Zx = -26.53 kN/sqm
My/Zy = -23.65 kN/sqm

Deff = 201 mm
Leff = 900 mm
SPu = 266.51 kN/sqm
Vu = SPu X (Boff - d) X L
= 23.75 kN
φVc = 110.82 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
Mux = -3.22 kNm
Muy = -2.87 kNm
P/A = 216.34 kN/sqm
Mx/Zx = -26.53 kN/sqm
My/Zy = -23.65 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 266.51 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 21 of 66

Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 146.83 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 175.23 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 0.81 sqm
A1 > Base Area
Thus, A1 = 0.81
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC5
Column No : C5 ( 300mm X 300mm)
Analysis No : 56

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 22 of 66

Live Load Reduction = 0 %


Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 900mm X 900mm X 300mm
Effective Self Weight = 6.08 KN

Offset Along L (Loff) = 300 mm


Offset Along B (Boff) = 300 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 95.61 kN
P = Pcomb + Effective Self Weight x 0.9
P = 101.07 kN
Mx = 1.37 kNm
My = 1.06 kNm
P/A = 124.78 kN/sqm
Mx/Zx = 11.3 kN/sqm
My/Zy = 8.75 kN/sqm
Maximum Soil Pressure = 144.83 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 95.61 kN
P = Pcomb + Effective Self Weight x 0.9
P = 101.07 kN
Mx = 1.37 kNm
My = 1.06 kNm
P/A = 124.78 kN/sqm
Mx/Zx = 11.3 kN/sqm
My/Zy = 8.75 kN/sqm
Minimum Soil Pressure = 104.73 kN/sqm
> 0

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 23 of 66

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
Mux = 2.14 kNm
Muy = 1.65 kNm
P/A = 183.6 kN/sqm
Mx/Zx = 17.58 kN/sqm
My/Zy = 13.61 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 214.79 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 8.7 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300
= 804 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
Mux = 2.14 kNm
Muy = 1.65 kNm
P/A = 183.6 kN/sqm
Mx/Zx = 17.58 kN/sqm
My/Zy = 13.61 kN/sqm

Deff = 201 mm
Leff = 900 mm
SPu = 214.79 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 8.7 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 24 of 66

= 804 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
Mux = 2.14 kNm
Muy = 1.65 kNm
P/A = 183.6 kN/sqm
Mx/Zx = 17.58 kN/sqm
My/Zy = 13.61 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 214.79 kN/sqm
Vu = SPu X (Loff - d) X B
= 16.05 kN
φVc = 119.64 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
Mux = 2.14 kNm
Muy = 1.65 kNm
P/A = 183.6 kN/sqm
Mx/Zx = 17.58 kN/sqm
My/Zy = 13.61 kN/sqm

Deff = 201 mm
Leff = 900 mm
SPu = 214.79 kN/sqm
Vu = SPu X (Boff - d) X L
= 19.14 kN

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 25 of 66

φVc = 110.82 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
Mux = 2.14 kNm
Muy = 1.65 kNm
P/A = 183.6 kN/sqm
Mx/Zx = 17.58 kN/sqm
My/Zy = 13.61 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 214.79 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 118.33 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 148.72 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 0.81 sqm
A1 > Base Area
Thus, A1 = 0.81
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3
Thus, Modification Factor = 2
= 0.65

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 26 of 66

Φ1
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC6
Column No : C6 ( 300mm X 300mm)
Analysis No : 58

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 950mm X 950mm X 300mm
Effective Self Weight = 6.77 KN

Offset Along L (Loff) = 325 mm


Offset Along B (Boff) = 325 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 149.07 kN
P = Pcomb + Effective Self Weight x 0.9
P = 155.16 kN
Mx = -0.72 kNm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 27 of 66

My = -0.9 kNm
P/A = 171.92 kN/sqm
Mx/Zx = -5.05 kN/sqm
My/Zy = -6.26 kN/sqm
Maximum Soil Pressure = 183.24 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 149.07 kN
P = Pcomb + Effective Self Weight x 0.9
P = 155.16 kN
Mx = -0.72 kNm
My = -0.9 kNm
P/A = 171.92 kN/sqm
Mx/Zx = -5.05 kN/sqm
My/Zy = -6.26 kN/sqm
Minimum Soil Pressure = 160.61 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 231.89 kN
Mux = -1.12 kNm
Muy = -1.39 kNm
P/A = 256.94 kN/sqm
Mx/Zx = -7.86 kN/sqm
My/Zy = -9.74 kN/sqm

Deff = 217 mm
Beff = 950 mm
SPu = 274.55 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 13.77 kNm
Ast Rqd = 783 sqmm
Ast (min) = 783 sqmm
Ast Prv = 5 - #16 @ 300

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 28 of 66

= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 231.89 kN
Mux = -1.12 kNm
Muy = -1.39 kNm
P/A = 256.94 kN/sqm
Mx/Zx = -7.86 kN/sqm
My/Zy = -9.74 kN/sqm

Deff = 201 mm
Leff = 950 mm
SPu = 274.55 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 13.77 kNm
Ast Rqd = 783 sqmm
Ast (min) = 783 sqmm
Ast Prv = 5 - #16 @ 300
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 231.89 kN
Mux = -1.12 kNm
Muy = -1.39 kNm
P/A = 256.94 kN/sqm
Mx/Zx = -7.86 kN/sqm
My/Zy = -9.74 kN/sqm

Deff = 217 mm
Beff = 950 mm
SPu = 274.55 kN/sqm
Vu = SPu X (Loff - d) X B

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 29 of 66

= 28.17 kN
φVc = 127.75 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 231.89 kN
Mux = -1.12 kNm
Muy = -1.39 kNm
P/A = 256.94 kN/sqm
Mx/Zx = -7.86 kN/sqm
My/Zy = -9.74 kN/sqm

Deff = 201 mm
Leff = 950 mm
SPu = 274.55 kN/sqm
Vu = SPu X (Boff - d) X L
= 32.34 kN
φVc = 118.33 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 232.4 kN
Mux = -0.87 kNm
Muy = -1.19 kNm
P/A = 257.5 kN/sqm
Mx/Zx = -6.12 kN/sqm
My/Zy = -8.34 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 30 of 66

= 271.96 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 174.98 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 232.4 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 0.9 sqm
A1 > Base Area
Thus, A1 = 0.9
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.1623
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC7
Column No : C7 ( 300mm X 300mm)
Analysis No : 48

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 31 of 66

Permissible SBC Increase for = 50 %


Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1300mm X 1300mm X 300mm
Effective Self Weight = 12.68 KN

Offset Along L (Loff) = 500 mm


Offset Along B (Boff) = 500 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 247.08 kN
P = Pcomb + Effective Self Weight x 0.9
P = 258.48 kN
Mx = 2.97 kNm
My = -4.27 kNm
P/A = 152.95 kN/sqm
Mx/Zx = 8.12 kN/sqm
My/Zy = -11.67 kN/sqm
Maximum Soil Pressure = 172.74 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 247.08 kN
P = Pcomb + Effective Self Weight x 0.9
P = 258.48 kN
Mx = 2.97 kNm
My = -4.27 kNm
P/A = 152.95 kN/sqm
Mx/Zx = 8.12 kN/sqm
My/Zy = -11.67 kN/sqm
Minimum Soil Pressure = 133.16 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 32 of 66

> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 450.19 kN
Mux = 3.85 kNm
Muy = -4.92 kNm
P/A = 266.38 kN/sqm
Mx/Zx = 10.5 kN/sqm
My/Zy = -13.45 kN/sqm

Deff = 217 mm
Beff = 1300 mm
SPu = 290.34 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 47.18 kNm
Ast Rqd = 1072 sqmm
Ast (min) = 1072 sqmm
Ast Prv = 6 - #16 @ 260
= 1206 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 450.19 kN
Mux = 3.85 kNm
Muy = -4.92 kNm
P/A = 266.38 kN/sqm
Mx/Zx = 10.5 kN/sqm
My/Zy = -13.45 kN/sqm

Deff = 201 mm
Leff = 1300 mm
SPu = 290.34 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 47.18 kNm
Ast Rqd = 978 sqmm
Ast (min) = 1072 sqmm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 33 of 66

Ast Prv = 6 - #16 @ 300


= 1206 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 450.19 kN
Mux = 3.85 kNm
Muy = -4.92 kNm
P/A = 266.38 kN/sqm
Mx/Zx = 10.5 kN/sqm
My/Zy = -13.45 kN/sqm

Deff = 217 mm
Beff = 1300 mm
SPu = 290.34 kN/sqm
Vu = SPu X (Loff - d) X B
= 106.81 kN
φVc = 166.77 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 450.19 kN
Mux = 3.85 kNm
Muy = -4.92 kNm
P/A = 266.38 kN/sqm
Mx/Zx = 10.5 kN/sqm
My/Zy = -13.45 kN/sqm

Deff = 201 mm
Leff = 1300 mm
SPu = 290.34 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 34 of 66

Vu = SPu X (Boff - d) X L
= 112.85 kN
φVc = 155.61 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 450.19 kN
Mux = 3.85 kNm
Muy = -4.92 kNm
P/A = 266.38 kN/sqm
Mx/Zx = 10.5 kN/sqm
My/Zy = -13.45 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 290.34 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 415.45 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 450.19 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.69 sqm
A1 > Base Area
Thus, A1 = 1.69
Modification Factor = SquareRoot(A1/A2)  < = 2

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 35 of 66

SquareRoot(A1/A2) = 4.3333
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC8
Column No : C8 ( 300mm X 300mm)
Analysis No : 47

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1400mm X 1400mm X 300mm
Effective Self Weight = 14.70 KN

Offset Along L (Loff) = 550 mm


Offset Along B (Boff) = 550 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 292.21 kN
P = Pcomb + Effective Self Weight x 0.9

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 36 of 66

P = 305.44 kN
Mx = -1.4 kNm
My = -4.31 kNm
P/A = 155.83 kN/sqm
Mx/Zx = -3.07 kN/sqm
My/Zy = -9.42 kN/sqm
Maximum Soil Pressure = 168.32 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 292.21 kN
P = Pcomb + Effective Self Weight x 0.9
P = 305.44 kN
Mx = -1.4 kNm
My = -4.31 kNm
P/A = 155.83 kN/sqm
Mx/Zx = -3.07 kN/sqm
My/Zy = -9.42 kN/sqm
Minimum Soil Pressure = 143.35 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 505.73 kN
Mux = -1.94 kNm
Muy = -4.97 kNm
P/A = 258.02 kN/sqm
Mx/Zx = -4.25 kN/sqm
My/Zy = -10.87 kN/sqm

Deff = 217 mm
Beff = 1400 mm
SPu = 273.14 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 57.84 kNm
Ast Rqd = 1110 sqmm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 37 of 66

Ast (min) = 1155 sqmm


Ast Prv = 6 - #16 @ 280
= 1206 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 505.73 kN
Mux = -1.94 kNm
Muy = -4.97 kNm
P/A = 258.02 kN/sqm
Mx/Zx = -4.25 kN/sqm
My/Zy = -10.87 kN/sqm

Deff = 201 mm
Leff = 1400 mm
SPu = 273.14 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 57.84 kNm
Ast Rqd = 1204 sqmm
Ast (min) = 1155 sqmm
Ast Prv = 6 - #16 @ 280
= 1206 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 505.73 kN
Mux = -1.94 kNm
Muy = -4.97 kNm
P/A = 258.02 kN/sqm
Mx/Zx = -4.25 kN/sqm
My/Zy = -10.87 kN/sqm

Deff = 217 mm
Beff = 1400 mm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 38 of 66

SPu = 273.14 kN/sqm


Vu = SPu X (Loff - d) X B
= 127.34 kN
φVc = 178.42 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 505.73 kN
Mux = -1.94 kNm
Muy = -4.97 kNm
P/A = 258.02 kN/sqm
Mx/Zx = -4.25 kN/sqm
My/Zy = -10.87 kN/sqm

Deff = 201 mm
Leff = 1400 mm
SPu = 273.14 kN/sqm
Vu = SPu X (Boff - d) X L
= 133.45 kN
φVc = 166.40 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 505.73 kN
Mux = -1.94 kNm
Muy = -4.97 kNm
P/A = 258.02 kN/sqm
Mx/Zx = -4.25 kN/sqm
My/Zy = -10.87 kN/sqm

Deff = 209 mm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 39 of 66

Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 273.14 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 464.58 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 505.73 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.96 sqm
A1 > Base Area
Thus, A1 = 1.96
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 4.6667
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC9
Column No : C9 ( 300mm X 300mm)
Analysis No : 46

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 40 of 66

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1150mm X 1150mm X 300mm
Effective Self Weight = 9.92 KN

Offset Along L (Loff) = 425 mm


Offset Along B (Boff) = 425 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 223.97 kN
P = Pcomb + Effective Self Weight x 0.9
P = 232.89 kN
Mx = -1.78 kNm
My = -3.52 kNm
P/A = 176.1 kN/sqm
Mx/Zx = -7.04 kN/sqm
My/Zy = -13.9 kN/sqm
Maximum Soil Pressure = 197.04 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 223.97 kN
P = Pcomb + Effective Self Weight x 0.9
P = 232.89 kN
Mx = -1.78 kNm
My = -3.52 kNm
P/A = 176.1 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 41 of 66

Mx/Zx = -7.04 kN/sqm


My/Zy = -13.9 kN/sqm
Minimum Soil Pressure = 155.16 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
Mux = -2.78 kNm
Muy = -5.48 kNm
P/A = 263.44 kN/sqm
Mx/Zx = -10.95 kN/sqm
My/Zy = -21.62 kN/sqm

Deff = 217 mm
Beff = 1150 mm
SPu = 296.01 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 30.74 kNm
Ast Rqd = 948 sqmm
Ast (min) = 948 sqmm
Ast Prv = 5 - #16 @ 290
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
Mux = -2.78 kNm
Muy = -5.48 kNm
P/A = 263.44 kN/sqm
Mx/Zx = -10.95 kN/sqm
My/Zy = -21.62 kN/sqm

Deff = 201 mm
Leff = 1150 mm
SPu = 296.01 kN/sqm
Mu = SPu X L X Boff X Boff / 2

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 42 of 66

= 30.74 kNm
Ast Rqd = 948 sqmm
Ast (min) = 948 sqmm
Ast Prv = 5 - #16 @ 290
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
Mux = -2.78 kNm
Muy = -5.48 kNm
P/A = 263.44 kN/sqm
Mx/Zx = -10.95 kN/sqm
My/Zy = -21.62 kN/sqm

Deff = 217 mm
Beff = 1150 mm
SPu = 296.01 kN/sqm
Vu = SPu X (Loff - d) X B
= 70.80 kN
φVc = 147.01 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
Mux = -2.78 kNm
Muy = -5.48 kNm
P/A = 263.44 kN/sqm
Mx/Zx = -10.95 kN/sqm
My/Zy = -21.62 kN/sqm

Deff = 201 mm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 43 of 66

Leff = 1150 mm
SPu = 296.01 kN/sqm
Vu = SPu X (Boff - d) X L
= 76.25 kN
φVc = 136.87 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
Mux = -2.78 kNm
Muy = -5.48 kNm
P/A = 263.44 kN/sqm
Mx/Zx = -10.95 kN/sqm
My/Zy = -21.62 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 296.01 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 314.78 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 348.39 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.32 sqm
A1 > Base Area
Thus, A1 = 1.32

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 44 of 66

Modification Factor = SquareRoot(A1/A2)  < = 2


SquareRoot(A1/A2) = 3.8297
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC10
Column No : C10 ( 300mm X 300mm)
Analysis No : 60

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 950mm X 950mm X 300mm
Effective Self Weight = 6.77 KN

Offset Along L (Loff) = 325 mm


Offset Along B (Boff) = 325 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 145.23 kN

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 45 of 66

P = Pcomb + Effective Self Weight x 0.9


P = 151.32 kN
Mx = -0.17 kNm
My = -1.27 kNm
P/A = 167.67 kN/sqm
Mx/Zx = -1.19 kN/sqm
My/Zy = -8.9 kN/sqm
Maximum Soil Pressure = 177.75 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 145.23 kN
P = Pcomb + Effective Self Weight x 0.9
P = 151.32 kN
Mx = -0.17 kNm
My = -1.27 kNm
P/A = 167.67 kN/sqm
Mx/Zx = -1.19 kN/sqm
My/Zy = -8.9 kN/sqm
Minimum Soil Pressure = 157.58 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 229.81 kN
Mux = 0.01 kNm
Muy = -1.77 kNm
P/A = 254.63 kN/sqm
Mx/Zx = 0.1 kN/sqm
My/Zy = -12.39 kN/sqm

Deff = 217 mm
Beff = 950 mm
SPu = 267.11 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 13.4 kNm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 46 of 66

Ast Rqd = 783 sqmm


Ast (min) = 783 sqmm
Ast Prv = 5 - #16 @ 300
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 229.81 kN
Mux = 0.01 kNm
Muy = -1.77 kNm
P/A = 254.63 kN/sqm
Mx/Zx = 0.1 kN/sqm
My/Zy = -12.39 kN/sqm

Deff = 201 mm
Leff = 950 mm
SPu = 267.11 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 13.4 kNm
Ast Rqd = 783 sqmm
Ast (min) = 783 sqmm
Ast Prv = 5 - #16 @ 300
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 229.81 kN
Mux = 0.01 kNm
Muy = -1.77 kNm
P/A = 254.63 kN/sqm
Mx/Zx = 0.1 kN/sqm
My/Zy = -12.39 kN/sqm

Deff = 217 mm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 47 of 66

Beff = 950 mm
SPu = 267.11 kN/sqm
Vu = SPu X (Loff - d) X B
= 27.41 kN
φVc = 127.75 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 229.81 kN
Mux = 0.01 kNm
Muy = -1.77 kNm
P/A = 254.63 kN/sqm
Mx/Zx = 0.1 kN/sqm
My/Zy = -12.39 kN/sqm

Deff = 201 mm
Leff = 950 mm
SPu = 267.11 kN/sqm
Vu = SPu X (Boff - d) X L
= 31.47 kN
φVc = 118.33 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 229.81 kN
Mux = 0.01 kNm
Muy = -1.77 kNm
P/A = 254.63 kN/sqm
Mx/Zx = 0.1 kN/sqm
My/Zy = -12.39 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 48 of 66

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 267.11 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 171.87 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 229.81 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 0.9 sqm
A1 > Base Area
Thus, A1 = 0.9
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.1623
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC11
Column No : C11 ( 300mm X 300mm)
Analysis No : 61

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 49 of 66

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 900mm X 900mm X 300mm
Effective Self Weight = 6.08 KN

Offset Along L (Loff) = 300 mm


Offset Along B (Boff) = 300 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 138.58 kN
P = Pcomb + Effective Self Weight x 0.9
P = 144.05 kN
Mx = -1.94 kNm
My = -0.43 kNm
P/A = 177.84 kN/sqm
Mx/Zx = -15.96 kN/sqm
My/Zy = -3.51 kN/sqm
Maximum Soil Pressure = 197.3 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 138.58 kN
P = Pcomb + Effective Self Weight x 0.9
P = 144.05 kN
Mx = -1.94 kNm
My = -0.43 kNm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 50 of 66

P/A = 177.84 kN/sqm


Mx/Zx = -15.96 kN/sqm
My/Zy = -3.51 kN/sqm
Minimum Soil Pressure = 158.37 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
Mux = -3.02 kNm
Muy = -0.66 kNm
P/A = 266.14 kN/sqm
Mx/Zx = -24.82 kN/sqm
My/Zy = -5.46 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 296.41 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 12 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300
= 804 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
Mux = -3.02 kNm
Muy = -0.66 kNm
P/A = 266.14 kN/sqm
Mx/Zx = -24.82 kN/sqm
My/Zy = -5.46 kN/sqm

Deff = 201 mm
Leff = 900 mm
SPu = 296.41 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 51 of 66

Mu = SPu X L X Boff X Boff / 2


= 12 kNm
Ast Rqd = 742 sqmm
Ast (min) = 742 sqmm
Ast Prv = 4 - #16 @ 300
= 804 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
Mux = -3.02 kNm
Muy = -0.66 kNm
P/A = 266.14 kN/sqm
Mx/Zx = -24.82 kN/sqm
My/Zy = -5.46 kN/sqm

Deff = 217 mm
Beff = 900 mm
SPu = 296.41 kN/sqm
Vu = SPu X (Loff - d) X B
= 22.14 kN
φVc = 119.64 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
Mux = -3.02 kNm
Muy = -0.66 kNm
P/A = 266.14 kN/sqm
Mx/Zx = -24.82 kN/sqm
My/Zy = -5.46 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 52 of 66

Deff = 201 mm
Leff = 900 mm
SPu = 296.41 kN/sqm
Vu = SPu X (Boff - d) X L
= 26.41 kN
φVc = 110.82 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
Mux = -3.02 kNm
Muy = -0.66 kNm
P/A = 266.14 kN/sqm
Mx/Zx = -24.82 kN/sqm
My/Zy = -5.46 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 296.41 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 163.3 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 215.57 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 0.81 sqm
A1 > Base Area

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 53 of 66

Thus, A1 = 0.81
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC12
Column No : C12 ( 300mm X 300mm)
Analysis No : 51

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1100mm X 1100mm X 300mm
Effective Self Weight = 9.08 KN

Offset Along L (Loff) = 400 mm


Offset Along B (Boff) = 400 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 54 of 66

Pcomb = 184.88 kN
P = Pcomb + Effective Self Weight x 0.9
P = 193.04 kN
Mx = 2.78 kNm
My = 5.24 kNm
P/A = 159.54 kN/sqm
Mx/Zx = 12.54 kN/sqm
My/Zy = 23.61 kN/sqm
Maximum Soil Pressure = 195.68 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 184.88 kN
P = Pcomb + Effective Self Weight x 0.9
P = 193.04 kN
Mx = 2.78 kNm
My = 5.24 kNm
P/A = 159.54 kN/sqm
Mx/Zx = 12.54 kN/sqm
My/Zy = 23.61 kN/sqm
Minimum Soil Pressure = 123.4 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 307.25 kN
Mux = 3.67 kNm
Muy = 6.58 kNm
P/A = 253.93 kN/sqm
Mx/Zx = 16.55 kN/sqm
My/Zy = 29.66 kN/sqm

Deff = 217 mm
Beff = 1100 mm
SPu = 300.14 kN/sqm
Mu = SPu X B X Loff X Loff / 2

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 55 of 66

= 26.41 kNm
Ast Rqd = 907 sqmm
Ast (min) = 907 sqmm
Ast Prv = 5 - #16 @ 275
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 307.25 kN
Mux = 3.67 kNm
Muy = 6.58 kNm
P/A = 253.93 kN/sqm
Mx/Zx = 16.55 kN/sqm
My/Zy = 29.66 kN/sqm

Deff = 201 mm
Leff = 1100 mm
SPu = 300.14 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 26.41 kNm
Ast Rqd = 907 sqmm
Ast (min) = 907 sqmm
Ast Prv = 5 - #16 @ 275
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 307.25 kN
Mux = 3.67 kNm
Muy = 6.58 kNm
P/A = 253.93 kN/sqm
Mx/Zx = 16.55 kN/sqm
My/Zy = 29.66 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 56 of 66

Deff = 217 mm
Beff = 1100 mm
SPu = 300.14 kN/sqm
Vu = SPu X (Loff - d) X B
= 60.42 kN
φVc = 142.01 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 307.25 kN
Mux = 3.67 kNm
Muy = 6.58 kNm
P/A = 253.93 kN/sqm
Mx/Zx = 16.55 kN/sqm
My/Zy = 29.66 kN/sqm

Deff = 201 mm
Leff = 1100 mm
SPu = 300.14 kN/sqm
Vu = SPu X (Boff - d) X L
= 65.70 kN
φVc = 131.54 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 307.25 kN
Mux = 3.67 kNm
Muy = 6.58 kNm
P/A = 253.93 kN/sqm
Mx/Zx = 16.55 kN/sqm
My/Zy = 29.66 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 57 of 66

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 300.14 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 285.41 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 307.25 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1.21 sqm
A1 > Base Area
Thus, A1 = 1.21
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.6667
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC13
Column No : C13 ( 300mm X 300mm)
Analysis No : 50

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 58 of 66

Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1200mm X 1200mm X 300mm
Effective Self Weight = 10.80 KN

Offset Along L (Loff) = 450 mm


Offset Along B (Boff) = 450 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 219.83 kN
P = Pcomb + Effective Self Weight x 0.9
P = 229.55 kN
Mx = -0.59 kNm
My = 5.52 kNm
P/A = 159.41 kN/sqm
Mx/Zx = -2.03 kN/sqm
My/Zy = 19.16 kN/sqm
Maximum Soil Pressure = 180.6 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 219.83 kN
P = Pcomb + Effective Self Weight x 0.9
P = 229.55 kN
Mx = -0.59 kNm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 59 of 66

My = 5.52 kNm
P/A = 159.41 kN/sqm
Mx/Zx = -2.03 kN/sqm
My/Zy = 19.16 kN/sqm
Minimum Soil Pressure = 138.21 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 358.58 kN
Mux = -0.84 kNm
Muy = 6.86 kNm
P/A = 249.01 kN/sqm
Mx/Zx = -2.91 kN/sqm
My/Zy = 23.82 kN/sqm

Deff = 217 mm
Beff = 1200 mm
SPu = 275.74 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 33.5 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv = 5 - #16 @ 300
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 358.58 kN
Mux = -0.84 kNm
Muy = 6.86 kNm
P/A = 249.01 kN/sqm
Mx/Zx = -2.91 kN/sqm
My/Zy = 23.82 kN/sqm

Deff = 201 mm
Leff = 1200 mm
SPu = 275.74 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 60 of 66

Mu = SPu X L X Boff X Boff / 2


= 33.5 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv = 5 - #16 @ 300
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 358.58 kN
Mux = -0.84 kNm
Muy = 6.86 kNm
P/A = 249.01 kN/sqm
Mx/Zx = -2.91 kN/sqm
My/Zy = 23.82 kN/sqm

Deff = 217 mm
Beff = 1200 mm
SPu = 275.74 kN/sqm
Vu = SPu X (Loff - d) X B
= 77.10 kN
φVc = 152.56 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 358.58 kN
Mux = -0.84 kNm
Muy = 6.86 kNm
P/A = 249.01 kN/sqm
Mx/Zx = -2.91 kN/sqm
My/Zy = 23.82 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 61 of 66

Deff = 201 mm
Leff = 1200 mm
SPu = 275.74 kN/sqm
Vu = SPu X (Boff - d) X L
= 82.39 kN
φVc = 142.26 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 4


Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)
Pu = 358.58 kN
Mux = -0.84 kNm
Muy = 6.86 kNm
P/A = 249.01 kN/sqm
Mx/Zx = -2.91 kN/sqm
My/Zy = 23.82 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 275.74 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 325.63 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 4
Combination
Critical Load Combination = [7] : 1.2 (LOAD 1: DL) +1.6
(LOAD 2: LL)
Pu = 358.58 kN
A2 = 0.09 sqm
A1 = 2.25 sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 62 of 66

Base Area = 1.44 sqm


A1 > Base Area
Thus, A1 = 1.44
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2011


Footing No : FC14
Column No : C14 ( 300mm X 300mm)
Analysis No : 49

Concrete Grade : C20


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 1.5 M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 220 kN/sqm
Permissible SBC Increase for EQ = 50 %
Permissible SBC Increase for = 50 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %

Cross Section designed by : Maximum pressure

Footing Type : Pad


Footing Size (L x B x D) : 1000mm X 1000mm X 300mm
Effective Self Weight = 7.50 KN

Offset Along L (Loff) = 350 mm


Offset Along B (Boff) = 350 mm

Check For Maximum Soil Pressure:

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 63 of 66

Critical Analysis Load = 7


Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 152.41 kN
P = Pcomb + Effective Self Weight x 0.9
P = 159.16 kN
Mx = -1.16 kNm
My = 5.57 kNm
P/A = 159.16 kN/sqm
Mx/Zx = -6.99 kN/sqm
My/Zy = 33.43 kN/sqm
Maximum Soil Pressure = 199.58 kN/sqm
Allowable Soil Pressure = 1x220 kN/sqm
= 220 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 7
Combination
Critical Load Combination = [5] : 0.9 (LOAD 1: DL)
Pcomb = 152.41 kN
P = Pcomb + Effective Self Weight x 0.9
P = 159.16 kN
Mx = -1.16 kNm
My = 5.57 kNm
P/A = 159.16 kN/sqm
Mx/Zx = -6.99 kN/sqm
My/Zy = 33.43 kN/sqm
Minimum Soil Pressure = 118.74 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
Mux = -1.81 kNm
Muy = 8.67 kNm
P/A = 237.09 kN/sqm
Mx/Zx = -10.87 kN/sqm
My/Zy = 52.01 kN/sqm

Deff = 217 mm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 64 of 66

Beff = 1000 mm
SPu = 299.96 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 18.37 kNm
Ast Rqd = 825 sqmm
Ast (min) = 825 sqmm
Ast Prv = 5 - #16 @ 250
= 1005 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
Mux = -1.81 kNm
Muy = 8.67 kNm
P/A = 237.09 kN/sqm
Mx/Zx = -10.87 kN/sqm
My/Zy = 52.01 kN/sqm

Deff = 201 mm
Leff = 1000 mm
SPu = 299.96 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 18.37 kNm
Ast Rqd = 825 sqmm
Ast (min) = 825 sqmm
Ast Prv = 5 - #16 @ 250
= 1005 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
Mux = -1.81 kNm
Muy = 8.67 kNm
P/A = 237.09 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 65 of 66

Mx/Zx = -10.87 kN/sqm


My/Zy = 52.01 kN/sqm

Deff = 217 mm
Beff = 1000 mm
SPu = 299.96 kN/sqm
Vu = SPu X (Loff - d) X B
= 39.89 kN
φVc = 132.35 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
Mux = -1.81 kNm
Muy = 8.67 kNm
P/A = 237.09 kN/sqm
Mx/Zx = -10.87 kN/sqm
My/Zy = 52.01 kN/sqm

Deff = 201 mm
Leff = 1000 mm
SPu = 299.96 kN/sqm
Vu = SPu X (Boff - d) X L
= 44.69 kN
φVc = 122.59 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Analysis Load = 3


Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
Mux = -1.81 kNm
Muy = 8.67 kNm
P/A = 237.09 kN/sqm

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023
Footing Design: Design Calculation Page 66 of 66

Mx/Zx = -10.87 kN/sqm


My/Zy = 52.01 kN/sqm

Deff = 209 mm
Leff = 509 mm
Beff = 509 mm
SPu = Max Pressure
= 299.96 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 222.25 kN
φVn = 713.625 kN
φVc = 470.993 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 3
Combination
Critical Load Combination = [6] : 1.4 (LOAD 1: DL)
Pu = 237.09 kN
A2 = 0.09 sqm
A1 = 2.25 sqm
Base Area = 1 sqm
A1 > Base Area
Thus, A1 = 1
Modification Factor = SquareRoot(A1/A2)  < = 2
SquareRoot(A1/A2) = 3.3333
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 1989 kN
Φ1Pnb > Pu, Hence Safe.

file:///C:/Users/63917/AppData/Local/Temp/tmp37F1.tmp 03/03/2023