You are on page 1of 56

FOOTING DESIGN CALCULATIONS

Project : 1001
Name
Client : ERIK_HERNANDEZ
Name
Engineer : MRHII
Name
Design : C:\Users\Eagle_roger\OneDrive\Desktop\3_Storey_cantilever\BASEMENT_SUB_STRUCTURE_-
File Footing-1.rcdx
Analysis : C:\Users\Eagle_roger\OneDrive\Desktop\3_Storey_cantilever\BASEMENT_SUB_STRUCTURE_.STD
File
Analysis : 06/03/2024 6:08:11 pm
Last
Modified

Definitions:
1. A = Plan area of footing base in 'sqmm'
2. Ast (min) = Area of longitudinal reinforcement as per code in 'sqmm'
3. Ast Prv = Area of tensile reinforcement provided in 'sqmm'
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment
and minimum % steel provided by user and as per code in
'sqmm'
5. Av = Area of shear reinforcement required in 'sqmm/m'
6. AvPrv = Area of shear reinforcement provided in 'sqmm/m'
7. A1 = Bearing area of footing at slope of 1:2 in 'sqmm'
8. A2 = C/s Area of column in 'sqmm'
9. B = Width of footing base in 'mm'
10. Beff = Effective width of footing in 'mm'
11. Boff = Footing offset along B in 'mm'
12. BoffB = Footing offset along B above column in plan in 'mm'
13. BoffT = Footing offset along B below column in planin 'mm'
14. B1 = Width of sloped footing at top in 'mm'
15. ColOff = Column offset in sloped footing in 'mm'
16. Cx = Width of column in 'mm'
17. Cy = Length of Column in 'mm'
18. D = Depth of footing in 'mm'
19. d = Effective Depth of footing in 'mm'
20. Dfd = Depth of founding layer in 'm'
21. Dw = Ground water level in 'm'
22. Ec = Modulus of elasticity of concrete in 'N/sqmm'
23. Es = Modulus of elasticity of steel in 'N/sqmm'
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in 'N/sqmm'
27. F'c = Characteristic strength of concrete in 'N/sqmm'

06/03/2024 21:00:44 pm 1/56


28. Icr = Moment of Inertia of concrete crack section in 'mm4'
29. L = Length of footing base in 'mm'
30. Leff = Effective length of footing in 'mm'
31. Loff = Footing offset along L in 'mm'
32. LoffL = Footing offset along L on left side of column in 'mm'
33. LoffR = Footing offset along L on right side of column in 'mm'
34. L1 = Length of sloped footing at top in 'mm'
35. Mcr = Cracking Moment
36. Mx = Bending Moment along column D in 'kNm'
37. Mex = Eccentricity moment along column D
38. Mxx = Total Bending Moment along column D (Mx + Mex)
39. My = Bending Moment along column B in 'kNm'
40. Mey = Eccentricity moment along column B
41. Myy = Total Bending Moment along column B (My + Mey)
42. Muy = Factored moment along column B in 'kNm'
43. Mux = Factored moment along column D in 'kNm'
44. Netdown = Net downward load in 'kN'
45. OB = Maximum permissible offset On bottom side Of column
46. OL = Maximum permissible offset On left side Of column
47. Or = Maximum permissible offset On right side Of column
48. OT = Maximum permissible offset On top side Of column
49. P = Axial load For footing sizing In 'kN'
50. Pcr(axial) = Design pressure at the critical section in 'kN/sqm'
51. P1 = Soil pressure at corner 1 In 'kN/sqm'
52. P2 = Soil pressure at corner 2 'kN/sqm'
53. P3 = Soil pressure at corner 3 'kN/sqm'
54. P4 = Soil pressure at corner 4 'kN/sqm'
55. q = Surcharge Load In 'kN/sqm'
56. sp = Spacing Between bars at outer most layer In 'mm'
57. SPu = Upward Soil Pressure In 'kN/sqm'
58. SPuL = Upward Soil Pressure from left
59. SPuR = Upward Soil Pressure from right
60. SPuB = Upward Soil Pressure from bottom
61. SPuT = Upward Soil Pressure from top
62. Temp1 = Peak Hydration temperature In Degree
63. Temp2 = Seasonal Temperature Variations In Degree
64. Vs Capacity = Shear strength capacity Of provided shear reinforcement
'kN'
65. Vs = Nominal shear strength provided by shear reinforcement, in
'kN'
66. Vc = Nominal shear strength provided by concrete in 'kN'
67. Vu = Design shear force in 'kN'
68. Vus = Strength of shear reinforcement in 'kN'
69. Vx = Shear along major axis in 'kN'
70. Vy = Shear along minor axis in 'kN'

06/03/2024 21:00:44 pm 2/56


71. Waterpr = Upward water pressure in 'kN/sqm'
72. Waterup = Upward force due to water in 'kN/sqm'
73. WFoot = Add. Wt. due to difference in concrete and soil density in
'kN'
74. WFootc = Weight of footing and column with concrete density in 'kN'
75. WSoil = Weight of soil covering footing area in 'kN'
76. y = Neutral axis depth.
77. Zx = Section modulus of footing base along L in 'mm4'
78. Zy = Section modulus of footing base along B in 'mm4'
79. Φ = Strength reduction factor in shear
80. Φ1 = Strength reduction factor in concrete bearing
81. Φ1Pnb = Bearing strength of column in 'kN'

Code References:
NSCP C101 - 2015
Sr.No. Item Clause / Table
1. Ptmax : 407.3.3.1, 408.3.3.1, 409.3.3.1
2. Ptmin : 407.6.1.1 & 408.6.1.1/407.7.2.3
3. Vc : 422.6.5
4. Av : 422.5.10.5 & 422.6.7
5. Max Stirrup Spacing : 409.7.6.2 & 410.7.6.5
6. Vs : 422.5.1.2
7. fs,perm : 424.3.2.1
8. fc,perm : 422.2.2.4.1
9. Wcr : Eq 1-2 ( ACI 224R-01)

Design Code : NSCP C101 - 2015


Footing No : FC3
Column No : C3 ( 850mm X 850mm)
Analysis No : 4

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %

06/03/2024 21:00:44 pm 3/56


Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 4000mm X 4000mm X 650mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 260 kN
Soil Weight, S1 = 371.24 kN
Total Weight, W1 = F1 + S1
= 631.24 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 156 kN
Soil Weight, S2 = 359.02 kN
Weight of Water (Submerged column),
= 0.58 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 514.44 kN
Offset Along L (Loff) = 1575 mm
Offset Along B (Boff) = 1575 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [17] : (LOAD 9: DL) +0.75 (LOAD 10: LL)
+0.525 (LOAD 3: EQ-X+E)
Pcomb = 2328.45 kN
P = Pcomb + W1
P = 2959.69 kN
Mx = -449.62 kNm
My = -239.18 kNm
P/A = 184.98 kN/sqm
Mx/Zx = -42.15 kN/sqm
My/Zy = -22.42 kN/sqm
Maximum Soil Pressure = 249.56 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Critical Load Combination = [33] : 0.6 (LOAD 9: DL)
+0.7 (LOAD 3: EQ-X+E)
Pcomb = 1214.85 kN
P = Pcomb + W2 x 0.6

06/03/2024 21:00:44 pm 4/56


P = 1523.52 kN
Mx = -393 kNm
My = -209.74 kNm
P/A = 95.22 kN/sqm
Mx/Zx = -36.84 kN/sqm
My/Zy = -19.66 kN/sqm
Minimum Soil Pressure = 38.71 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 3729.2 kN
Mux = -783.78 kNm
Muy = -425.76 kNm
P/A = 233.07 kN/sqm
Mx/Zx = -73.48 kN/sqm
My/Zy = -39.91 kN/sqm

Deff = 602 mm
Beff = 4000 mm
SPu = 306.55 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1520.89 kNm
Ast Rqd = 10532.35 sqmm
Ast (min) = 5200 sqmm
Ast Prv (Distributed Across Total Width) = 35 - #20 @ 120
= 10995.6 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 30 - #12 @ 140 c/c
= 3393 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 212
Critical Load Combination = [77] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 7: EQ-Z+E)
Pu = 3951.04 kN
Mux = -531.67 kNm
Muy = -421.99 kNm
P/A = 246.94 kN/sqm
Mx/Zx = -49.84 kN/sqm
My/Zy = -39.56 kN/sqm

06/03/2024 21:00:44 pm 5/56


Deff = 586 mm
Leff = 4000 mm
SPu = 286.5 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 1421.41 kNm
Ast Rqd = 10107.07 sqmm
Ast (min) = 5200 sqmm
Ast Prv (Distributed Across Total Length) = 33 - #20 @ 125
= 10367.28 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total Length) = 30 - #12 @ 140 c/c
= 3393 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 602 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 3729.2 kN
Mux = -783.78 kNm
Muy = -425.76 kNm
P/A = 233.07 kN/sqm
Mx/Zx = -73.48 kN/sqm
My/Zy = -39.91 kN/sqm

Deff = 602 mm
Beff = 4000 mm
SPu = 306.55 kN/sqm
Vu = SPu X (Loff - d) X B
= 1193.11 kN
φVc = 1487.53 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 586 mm
Critical Analysis Load Combination = 212
Critical Load Combination = [77] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 7: EQ-Z+E)
Pu = 3951.04 kN

06/03/2024 21:00:44 pm 6/56


Mux = -531.67 kNm
Muy = -421.99 kNm
P/A = 246.94 kN/sqm
Mx/Zx = -49.84 kN/sqm
My/Zy = -39.56 kN/sqm

Deff = 586 mm
Leff = 4000 mm
SPu = 286.5 kN/sqm
Vu = SPu X (Boff - d) X L
= 1133.4 kN
φVc = 1435.77 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 297 mm

Critical Analysis Load Combination = 207


Critical Load Combination = [72] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 2: EQ+X-E)
Pu = 4199.51 kN
Mux = -108.51 kNm
Muy = -95.37 kNm
P/A = 262.47 kN/sqm
Mx/Zx = -10.17 kN/sqm
My/Zy = -8.94 kN/sqm

Deff = 594 mm
Leff = 1444 mm
Beff = 1444 mm
Punching Perimeter = 5776 mm
Punching Area = 3430944 sqmm
SPu = Average Pressure
= 262.47 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 3652.22 kN
φVn = 5850.87 kN
φVc = 3861.57 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm

06/03/2024 21:00:44 pm 7/56


= 0.05% X 650 X 500
= 162.5 sqmm

Asfr Prv = 3-#10


= 235.62 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 207
Critical Load Combination = [72] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 2: EQ+X-E)
Pu = 4199.51 kN
A2 = 0.72 sqm
A1 = 11.9 sqm
Base Area = 16 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4.0654
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 16510.14 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC4
Column No : C4 ( 2000mm X 300mm)
MESHED
Analysis No :
SURFACE 2-2

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %

06/03/2024 21:00:44 pm 8/56


Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 6100mm X 4400mm X 500mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 335.5 kN
Soil Weight, S1 = 708.48 kN
Total Weight, W1 = F1 + S1
= 1043.98 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 201.3 kN
Soil Weight, S2 = 648.13 kN
Weight of Water (Submerged column),
= 1.38 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 848.05 kN
Offset Along L (Loff) = 2050 mm
Offset Along B (Boff) = 2050 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [5] : (LOAD 9: DL) +0.7 (LOAD 3: EQ-X+E)
Pcomb = 963.66 kN
P = Pcomb + W1
P = 2007.64 kN
Mx = 1396.13 kNm
My = 9.97 kNm
P/A = 74.8 kN/sqm
Mx/Zx = 51.16 kN/sqm
My/Zy = 0.51 kN/sqm
Maximum Soil Pressure = 126.47 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [33] : 0.6 (LOAD 9: DL) +0.7 (LOAD 3: EQ-
X+E)
Pcomb = 571.4 kN
P = Pcomb + W2 x 0.6
P = 1080.23 kN

06/03/2024 21:00:44 pm 9/56


Mx = 1138.05 kNm
My = 5.63 kNm
P/A = 44.63 kN/sqm
Mx/Zx = 41.71 kN/sqm
My/Zy = 0.29 kN/sqm
Minimum Soil Pressure = -1.75 kN/sqm
< 0
Uplift condition = Short edge uplift
Area of loss of contact = 0.49 sqm
= 1.814 %
< 2 %
Corner pressure P1 = -1.22 kN/sqm
Corner pressure P2 = 82.27 kN/sqm
Corner pressure P3 = 81.69 kN/sqm
Corner pressure P4 = -1.81 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge 1 = 0.13 m
Along long edge 2 = 0.09 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1631.35 kN
Mux = 2153.66 kNm
Muy = 17.06 kNm
P/A = 60.78 kN/sqm
Mx/Zx = 78.93 kN/sqm
My/Zy = 0.87 kN/sqm

Deff = 452 mm
Beff = 4400 mm
SPu = 139.71 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1291.65 kNm
Ast Rqd = 12080.2 sqmm
Ast (min) = 4400 sqmm
Ast Prv (Distributed Across Total Width) = 40 - #20 @ 115
= 12566.4 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.814 %
Weight of footing per unit area (W1) = D X Concrete Density

06/03/2024 21:00:44 pm 10/56


= 12.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 27 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 39.5 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 110.65 mm
Moment along L = W X (LOCL^2) X B / 2
= 1.06 kNm
Effective width = B
= 4400 mm
Pt = 0.22 %
Ast Calculated = 4400 sqmm
Ast Provided = 40 - #12 @ 115 c/c
= 4524 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 213
Critical Load Combination = [78] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 8: EQ-Z-E)
Pu = 2194.3 kN
Mux = 1123.58 kNm
Muy = 34.51 kNm
P/A = 81.75 kN/sqm
Mx/Zx = 41.18 kN/sqm
My/Zy = 1.75 kN/sqm

Deff = 436 mm
Leff = 6100 mm
SPu = 83.51 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 1070.38 kNm
Ast Rqd = 10189.72 sqmm
Ast (min) = 6100 sqmm
Ast Prv (Distributed Across Total Length) = 52 - #16 @ 120
= 10455.12 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.814 %
Weight of footing per unit area (W1) = D X ConDen
= 12.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 27 kN/sqm
Total downward weigth per unit area (W) = W1 + W2

06/03/2024 21:00:44 pm 11/56


= 39.5 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 79.82 mm
Moment along B = W X (LOCB^2) X L / 2
= 0.77 kNm
Effective width = L
= 6100 mm
Pt = 0.23 %
Ast Calculated = 6100 sqmm
Ast Provided = 55 - #12 @ 115 c/c
= 6220.5 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 452 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1631.35 kN
Mux = 2153.66 kNm
Muy = 17.06 kNm
P/A = 60.78 kN/sqm
Mx/Zx = 78.93 kN/sqm
My/Zy = 0.87 kN/sqm

Deff = 452 mm
Beff = 4400 mm
SPu = 139.71 kN/sqm
Vu = SPu X (Loff - d) X B
= 982.3 kN
φVc = 1245.52 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 436 mm
Critical Analysis Load Combination = 213
Critical Load Combination = [78] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 8: EQ-Z-E)
Pu = 2194.3 kN
Mux = 1123.58 kNm
Muy = 34.51 kNm

06/03/2024 21:00:44 pm 12/56


P/A = 81.75 kN/sqm
Mx/Zx = 41.18 kN/sqm
My/Zy = 1.75 kN/sqm

Deff = 436 mm
Leff = 6100 mm
SPu = 83.51 kN/sqm
Vu = SPu X (Boff - d) X L
= 822.17 kN
φVc = 1584.66 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 222 mm

Critical Analysis Load Combination = 213


Critical Load Combination = [78] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 8: EQ-Z-E)
Pu = 2194.3 kN
Mux = 1123.58 kNm
Muy = 34.51 kNm
P/A = 81.75 kN/sqm
Mx/Zx = 41.18 kN/sqm
My/Zy = 1.75 kN/sqm

Deff = 444 mm
Leff = 2444 mm
Beff = 744 mm
Punching Perimeter = 6376 mm
Punching Area = 2830944 sqmm
SPu = Average Pressure
= 81.75 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 2045.64 kN
φVn = 4827.67 kN
φVc = 2133.83 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 500 X 500
= 125 sqmm

06/03/2024 21:00:44 pm 13/56


Asfr Prv = 2-#10
= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 213
Critical Load Combination = [78] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 8: EQ-Z-E)
Pu = 2194.3 kN
A2 = 0.6 sqm
A1 = 9.2 sqm
Base Area = 26.84 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.9158
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 13710.84 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC5
Column No : C5 ( 850mm X 850mm)
Analysis No : 67

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure

06/03/2024 21:00:44 pm 14/56


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 3600mm X 3600mm X 550mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 178.2 kN
Soil Weight, S1 = 319.4 kN
Total Weight, W1 = F1 + S1
= 497.6 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 106.92 kN
Soil Weight, S2 = 297.37 kN
Weight of Water (Submerged column),
= 1.3 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 402.99 kN
Offset Along L (Loff) = 1375 mm
Offset Along B (Boff) = 1375 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [5] : (LOAD 9: DL) +0.7 (LOAD 3: EQ-X+E)
Pcomb = 1779 kN
P = Pcomb + W1
P = 2276.6 kN
Mx = 400.83 kNm
My = -266.46 kNm
P/A = 175.66 kN/sqm
Mx/Zx = 51.55 kN/sqm
My/Zy = -34.27 kN/sqm
Maximum Soil Pressure = 261.48 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Critical Load Combination = [33] : 0.6 (LOAD 9: DL)
+0.7 (LOAD 3: EQ-X+E)
Pcomb = 1013.67 kN
P = Pcomb + W2 x 0.6
P = 1255.47 kN
Mx = 326.27 kNm
My = -206.14 kNm
P/A = 96.87 kN/sqm
Mx/Zx = 41.96 kN/sqm

06/03/2024 21:00:44 pm 15/56


My/Zy = -26.51 kN/sqm
Minimum Soil Pressure = 28.4 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 3063.04 kN
Mux = 618.94 kNm
Muy = -415.74 kNm
P/A = 236.35 kN/sqm
Mx/Zx = 79.6 kN/sqm
My/Zy = -53.46 kN/sqm

Deff = 502 mm
Beff = 3600 mm
SPu = 315.94 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1075.19 kNm
Ast Rqd = 8972.11 sqmm
Ast (min) = 3960 sqmm
Ast Prv (Distributed Across Total Width) = 29 - #20 @ 130
= 9110.64 sqmm

Top Steel Along L:


Ast Prv (Distributed Across Total Width) = 33 - #10 @ 115 c/c
= 2591.82 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 212
Critical Load Combination = [77] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 7: EQ-Z+E)
Pu = 3203.57 kN
Mux = 337.57 kNm
Muy = -412.37 kNm
P/A = 247.19 kN/sqm
Mx/Zx = 43.41 kN/sqm
My/Zy = -53.03 kN/sqm

Deff = 486 mm
Leff = 3600 mm
SPu = 300.22 kN/sqm
Mu = SPu X L X Boff X Boff / 2

06/03/2024 21:00:44 pm 16/56


= 1021.69 kNm
Ast Rqd = 8811.52 sqmm
Ast (min) = 3960 sqmm
Ast Prv (Distributed Across Total Length) = 29 - #20 @ 130
= 9110.64 sqmm

Top Steel Along B:


Ast Prv (Distributed Across Total Length) = 33 - #10 @ 115 c/c
= 2591.82 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 502 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 3063.04 kN
Mux = 618.94 kNm
Muy = -415.74 kNm
P/A = 236.35 kN/sqm
Mx/Zx = 79.6 kN/sqm
My/Zy = -53.46 kN/sqm

Deff = 502 mm
Beff = 3600 mm
SPu = 315.94 kN/sqm
Vu = SPu X (Loff - d) X B
= 992.94 kN
φVc = 1119.79 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 486 mm
Critical Analysis Load Combination = 212
Critical Load Combination = [77] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 7: EQ-Z+E)
Pu = 3203.57 kN
Mux = 337.57 kNm
Muy = -412.37 kNm
P/A = 247.19 kN/sqm
Mx/Zx = 43.41 kN/sqm
My/Zy = -53.03 kN/sqm

06/03/2024 21:00:44 pm 17/56


Deff = 486 mm
Leff = 3600 mm
SPu = 300.22 kN/sqm
Vu = SPu X (Boff - d) X L
= 960.83 kN
φVc = 1081.77 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 247 mm

Critical Analysis Load Combination = 207


Critical Load Combination = [72] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 2: EQ+X-E)
Pu = 3446.8 kN
Mux = 6.3 kNm
Muy = -85.29 kNm
P/A = 265.96 kN/sqm
Mx/Zx = 0.81 kN/sqm
My/Zy = -10.97 kN/sqm

Deff = 494 mm
Leff = 1344 mm
Beff = 1344 mm
Punching Perimeter = 5376 mm
Punching Area = 2655744 sqmm
SPu = Average Pressure
= 265.96 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 2966.39 kN
φVn = 4528.9 kN
φVc = 2989.07 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 550 X 500
= 137.5 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

06/03/2024 21:00:44 pm 18/56


Load Transfer Check For Load Transfer From Column To Footing
Critical Analysis Load Combination = 207
Critical Load Combination = [72] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 2: EQ+X-E)
Pu = 3446.8 kN
A2 = 0.72 sqm
A1 = 9.3 sqm
Base Area = 12.96 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.594
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 16510.14 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC6
Column No : C6 ( 5500mm X 300mm)
MESHED
Analysis No :
SURFACE 3-2

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

06/03/2024 21:00:44 pm 19/56


Footing Type : Pad
Footing Size (L x B x D) : 9950mm X 4750mm X 525mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 620.32 kN
Soil Weight, S1 = 1211.01 kN
Total Weight, W1 = F1 + S1
= 1831.33 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 372.19 kN
Soil Weight, S2 = 1117.51 kN
Weight of Water (Submerged column),
= 3.38 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 1486.32 kN
Offset Along L (Loff) = 2225 mm
Offset Along B (Boff) = 2225 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [7] : (LOAD 9: DL) -0.7 (LOAD 1: EQ+X+E)
Pcomb = 2722.39 kN
P = Pcomb + W1
P = 4553.72 kN
Mx = -1938.31 kNm
My = 87.62 kNm
P/A = 96.35 kN/sqm
Mx/Zx = -24.73 kN/sqm
My/Zy = 2.34 kN/sqm
Maximum Soil Pressure = 123.42 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [31] : 0.6 (LOAD 9: DL) +0.7 (LOAD 1:
EQ+X+E)
Pcomb = -163.22 kN
P = Pcomb + W2 x 0.6
P = 728.57 kN
Mx = -1230.52 kNm
My = -30.54 kNm
P/A = 19.8 kN/sqm
Mx/Zx = -15.7 kN/sqm
My/Zy = -0.82 kN/sqm

06/03/2024 21:00:44 pm 20/56


Minimum Soil Pressure = -1.1 kN/sqm
< 0
Uplift condition = Corner uplift
Area of loss of contact = 0.58 sqm
= 1.227 %
< 2 %
Corner pressure P1 = 0.52 kN/sqm
Corner pressure P2 = 31.95 kN/sqm
Corner pressure P3 = 30.3 kN/sqm
Corner pressure P4 = -1.13 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge = 3.25 m
Along short edge = 0.36 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
Mux = -3283.34 kNm
Muy = 133.81 kNm
P/A = 90.37 kN/sqm
Mx/Zx = -41.89 kN/sqm
My/Zy = 3.58 kN/sqm

Deff = 477 mm
Beff = 4750 mm
SPu = 132.26 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1555.09 kNm
Ast Rqd = 13782.76 sqmm
Ast (min) = 4987.5 sqmm
Ast Prv (Distributed Across Total Width) = 45 - #20 @ 110
= 14137.2 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.227 %
Weight of footing per unit area (W1) = D X Concrete Density
= 13.12 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 26.55 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 39.67 kN/sqm

06/03/2024 21:00:44 pm 21/56


Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 122.09 mm
Moment along L = W X (LOCL^2) X B / 2
= 1.4 kNm
Effective width = B
= 4750 mm
Pt = 0.22 %
Ast Calculated = 4988 sqmm
Ast Provided = 45 - #12 @ 110 c/c
= 5089.5 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
Mux = -3283.34 kNm
Muy = 133.81 kNm
P/A = 90.37 kN/sqm
Mx/Zx = -41.89 kN/sqm
My/Zy = 3.58 kN/sqm

Deff = 461 mm
Leff = 9950 mm
SPu = 93.95 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 2313.81 kNm
Ast Rqd = 20957.52 sqmm
Ast (min) = 10447.5 sqmm
Ast Prv (Distributed Across Total Length) = 68 - #20 @ 150
= 21362.88 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.227 %
Weight of footing per unit area (W1) = D X ConDen
= 13.12 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 26.55 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 39.67 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 58.28 mm
Moment along B = W X (LOCB^2) X L / 2

06/03/2024 21:00:44 pm 22/56


= 0.67 kNm
Effective width = L
= 9950 mm
Pt = 0.23 %
Ast Calculated = 10448 sqmm
Ast Provided = 96 - #12 @ 105 c/c
= 10857.6 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 477 mm
Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
Mux = -3283.34 kNm
Muy = 133.81 kNm
P/A = 90.37 kN/sqm
Mx/Zx = -41.89 kN/sqm
My/Zy = 3.58 kN/sqm

Deff = 477 mm
Beff = 4750 mm
SPu = 132.26 kN/sqm
Vu = SPu X (Loff - d) X B
= 1098.16 kN
φVc = 1416.68 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 461 mm
Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
Mux = -3283.34 kNm
Muy = 133.81 kNm
P/A = 90.37 kN/sqm
Mx/Zx = -41.89 kN/sqm
My/Zy = 3.58 kN/sqm

Deff = 461 mm

06/03/2024 21:00:44 pm 23/56


Leff = 9950 mm
SPu = 93.95 kN/sqm
Vu = SPu X (Boff - d) X L
= 1648.91 kN
φVc = 2775.49 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 234 mm

Critical Analysis Load Combination = 209


Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
Mux = -3283.34 kNm
Muy = 133.81 kNm
P/A = 90.37 kN/sqm
Mx/Zx = -41.89 kN/sqm
My/Zy = 3.58 kN/sqm

Deff = 469 mm
Leff = 5969 mm
Beff = 769 mm
Punching Perimeter = 13476 mm
Punching Area = 6320244 sqmm
SPu = Average Pressure
= 90.37 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 3856.26 kN
φVn = 10778.06 kN
φVc = 4064.31 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 525 X 500
= 131.25 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing

06/03/2024 21:00:44 pm 24/56


Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 4: EQ-X-E)
Pu = 4271.07 kN
A2 = 1.65 sqm
A1 = 18.24 sqm
Base Area = 47.26 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.3248
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 37704.81 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC7
Column No : C7 ( 5500mm X 300mm)
MESHED
Analysis No :
SURFACE 5-2

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad

06/03/2024 21:00:44 pm 25/56


Footing Size (L x B x D) : 11900mm X 6700mm X 350mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 697.64 kN
Soil Weight, S1 = 2318.98 kN
Total Weight, W1 = F1 + S1
= 3016.61 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 418.58 kN
Soil Weight, S2 = 2022.27 kN
Weight of Water (Submerged column),
= 6.27 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 2434.58 kN
Offset Along L (Loff) = 3200 mm
Offset Along B (Boff) = 3200 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [10] : (LOAD 9: DL) -0.7 (LOAD 4: EQ-X-E)
Pcomb = 1252.15 kN
P = Pcomb + W1
P = 4268.76 kN
Mx = -1977.04 kNm
My = -18.73 kNm
P/A = 53.54 kN/sqm
Mx/Zx = -12.5 kN/sqm
My/Zy = -0.21 kN/sqm
Maximum Soil Pressure = 66.25 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [34] : 0.6 (LOAD 9: DL) +0.7 (LOAD 4: EQ-X-
E)
Pcomb = -948.7 kN
P = Pcomb + W2 x 0.6
P = 512.05 kN
Mx = -1011.03 kNm
My = 72.39 kNm
P/A = 10.8 kN/sqm
Mx/Zx = -6.39 kN/sqm
My/Zy = 0.81 kN/sqm
Minimum Soil Pressure = -0.78 kN/sqm
< 0

06/03/2024 21:00:44 pm 26/56


Uplift condition = Corner uplift
Area of loss of contact = 1.24 sqm
= 1.558 %
< 2 %
Corner pressure P1 = 0.84 kN/sqm
Corner pressure P2 = 13.65 kN/sqm
Corner pressure P3 = 12 kN/sqm
Corner pressure P4 = -0.81 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge = 3.3 m
Along short edge = 0.75 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 1844.56 kN
Mux = -3308.81 kNm
Muy = -18.69 kNm
P/A = 23.14 kN/sqm
Mx/Zx = -20.92 kN/sqm
My/Zy = -0.21 kN/sqm

Deff = 302 mm
Beff = 6700 mm
SPu = 44.06 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1511.42 kNm
Ast Rqd = 22030.92 sqmm
Ast (min) = 4690 sqmm
Ast Prv (Distributed Across Total Width) = 45 - #25 @ 155
= 22089.15 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.558 %
Weight of footing per unit area (W1) = D X Concrete Density
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)

06/03/2024 21:00:44 pm 27/56


= 185.4 mm
Moment along L = W X (LOCL^2) X B / 2
= 4.43 kNm
Effective width = B
= 6700 mm
Pt = 1.15 %
Ast Calculated = 23185 sqmm
Ast Provided = 45 - #25 @ 145 c/c
= 22089.15 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 1844.56 kN
Mux = -3308.81 kNm
Muy = -18.69 kNm
P/A = 23.14 kN/sqm
Mx/Zx = -20.92 kN/sqm
My/Zy = -0.21 kN/sqm

Deff = 286 mm
Leff = 11900 mm
SPu = 23.34 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 1422.36 kNm
Ast Rqd = 21042.75 sqmm
Ast (min) = 8330 sqmm
Ast Prv (Distributed Across Total Length) = 105 - #16 @ 115
= 21111.3 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.558 %
Weight of footing per unit area (W1) = D X ConDen
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 104.39 mm
Moment along B = W X (LOCB^2) X L / 2
= 2.49 kNm
Effective width = L

06/03/2024 21:00:44 pm 28/56


= 11900 mm
Pt = 1.29 %
Ast Calculated = 44046 sqmm
Ast Provided = 90 - #25 @ 135 c/c
= 44178.3 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 302 mm
Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 1844.56 kN
Mux = -3308.81 kNm
Muy = -18.69 kNm
P/A = 23.14 kN/sqm
Mx/Zx = -20.92 kN/sqm
My/Zy = -0.21 kN/sqm

Deff = 302 mm
Beff = 6700 mm
SPu = 44.06 kN/sqm
Vu = SPu X (Loff - d) X B
= 855.49 kN
φVc = 1385.81 kN
Vu < φVc
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 38.45 kN/sqm
Deff = 302 mm
Beff = 6700 mm
Vu = q x Loff X B X 1.2
= 989.24 kN
φVc = 1399.78 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 286 mm
Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1844.56 kN

06/03/2024 21:00:44 pm 29/56


Mux = -3308.81 kNm
Muy = -18.69 kNm
P/A = 23.14 kN/sqm
Mx/Zx = -20.92 kN/sqm
My/Zy = -0.21 kN/sqm

Deff = 286 mm
Leff = 11900 mm
SPu = 23.34 kN/sqm
Vu = SPu X (Boff - d) X L
= 809.53 kN
φVc = 2126.42 kN
Vu < φVc

One Way Shear Along B (Tension Case):


At face of Column
Soil + Surcharge Load,q = 38.45 kN/sqm
Deff = 286 mm
Leff = 11900 mm
Vu = q x Boff X L X 1.2
= 1757.01 kN
φVc = 2418.84 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 147 mm

Critical Analysis Load Combination = 206


Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 1844.56 kN
Mux = -3308.81 kNm
Muy = -18.69 kNm
P/A = 23.14 kN/sqm
Mx/Zx = -20.92 kN/sqm
My/Zy = -0.21 kN/sqm

Deff = 294 mm
Leff = 5794 mm
Beff = 594 mm
Punching Perimeter = 12776 mm
Punching Area = 3756144 sqmm
SPu = Average Pressure

06/03/2024 21:00:44 pm 30/56


= 23.14 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 1764.94 kN
φVn = 6405.44 kN
φVc = 2415.43 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -1267.03 kN
Deff = 294 mm
Leff = 5500 mm
Beff = 300 mm
Punching Perimeter = 11600 mm
Punching Area = 3410400 sqmm
Vu = 1267.03 kN
φVc = 5815.83 kN
Vu < φVc
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 350 X 500
= 87.5 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 1844.56 kN
A2 = 1.65 sqm
A1 = 11.73 sqm
Base Area = 79.73 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 2.6663
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area

06/03/2024 21:00:44 pm 31/56


= 37704.81 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC8
Column No : C8 ( 2000mm X 300mm)
MESHED
Analysis No :
SURFACE 4-2

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 7000mm X 5300mm X 350mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 324.62 kN
Soil Weight, S1 = 1084.05 kN
Total Weight, W1 = F1 + S1
= 1408.68 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 194.77 kN
Soil Weight, S2 = 945.35 kN
Weight of Water (Submerged column),
= 2.28 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 1137.84 kN
Offset Along L (Loff) = 2500 mm

06/03/2024 21:00:44 pm 32/56


Offset Along B (Boff) = 2500 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [12] : (LOAD 9: DL) +0.7 (LOAD 6: EQ+Z-E)
Pcomb = 112.01 kN
P = Pcomb + W1
P = 1520.69 kN
Mx = -274.54 kNm
My = 2.09 kNm
P/A = 40.99 kN/sqm
Mx/Zx = -6.34 kN/sqm
My/Zy = 0.06 kN/sqm
Maximum Soil Pressure = 47.4 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [41] : 0.6 (LOAD 9: DL) +0.7 (LOAD 7: EQ-
Z+E)
Pcomb = -523.18 kN
P = Pcomb + W2 x 0.6
P = 159.53 kN
Mx = 184.9 kNm
My = -15.43 kNm
P/A = 8.68 kN/sqm
Mx/Zx = 4.27 kN/sqm
My/Zy = -0.47 kN/sqm
Minimum Soil Pressure = -0.44 kN/sqm
< 0
Uplift condition = Corner uplift
Area of loss of contact = 0.47 sqm
= 1.271 %
< 2 %
Corner pressure P1 = 0.5 kN/sqm
Corner pressure P2 = 9.05 kN/sqm
Corner pressure P3 = 8.1 kN/sqm
Corner pressure P4 = -0.46 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge = 2.53 m
Along short edge = 0.37 m

Design For Bending:


Bottom Reinforcement Along L:

06/03/2024 21:00:44 pm 33/56


Critical Analysis Load Combination = 108
Critical Load Combination = [54] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 6: EQ+Z-E)
Pu = 218.24 kN
Mux = -374.19 kNm
Muy = 4.82 kNm
P/A = 5.88 kN/sqm
Mx/Zx = -8.65 kN/sqm
My/Zy = 0.15 kN/sqm

Deff = 302 mm
Beff = 5300 mm
SPu = 14.53 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 240.61 kNm
Ast Rqd = 3710 sqmm
Ast (min) = 3710 sqmm
Ast Prv (Distributed Across Total Width) = 48 - #10 @ 115
= 3769.92 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.271 %
Weight of footing per unit area (W1) = D X Concrete Density
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 88.97 mm
Moment along L = W X (LOCL^2) X B / 2
= 0.81 kNm
Effective width = B
= 5300 mm
Pt = 0.67 %
Ast Calculated = 10754 sqmm
Ast Provided = 48 - #16 @ 100 c/c
= 9650.88 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 107
Critical Load Combination = [53] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 5: EQ+Z+E)
Pu = 231.63 kN

06/03/2024 21:00:44 pm 34/56


Mux = -196.7 kNm
Muy = 5.23 kNm
P/A = 6.24 kN/sqm
Mx/Zx = -4.54 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 286 mm
Leff = 7000 mm
SPu = 6.4 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 140.07 kNm
Ast Rqd = 4900 sqmm
Ast (min) = 4900 sqmm
Ast Prv (Distributed Across Total Length) = 65 - #10 @ 110
= 5105.1 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.271 %
Weight of footing per unit area (W1) = D X ConDen
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 67.36 mm
Moment along B = W X (LOCB^2) X L / 2
= 0.61 kNm
Effective width = L
= 7000 mm
Pt = 0.75 %
Ast Calculated = 15101 sqmm
Ast Provided = 50 - #20 @ 145 c/c
= 15708 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 302 mm
Critical Analysis Load Combination = 108
Critical Load Combination = [54] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 6: EQ+Z-E)
Pu = 218.24 kN
Mux = -374.19 kNm
Muy = 4.82 kNm

06/03/2024 21:00:44 pm 35/56


P/A = 5.88 kN/sqm
Mx/Zx = -8.65 kN/sqm
My/Zy = 0.15 kN/sqm

Deff = 302 mm
Beff = 5300 mm
SPu = 14.53 kN/sqm
Vu = SPu X (Loff - d) X B
= 169.24 kN
φVc = 921.52 kN
Vu < φVc
One Way Shear Along L (Tension Case):
At face of column
Soil + Surcharge Load,q = 38.45 kN/sqm
Deff = 302 mm
Beff = 5300 mm
Vu = q x Loff X B X 1.2
= 611.36 kN
φVc = 1010.57 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 286 mm
Critical Analysis Load Combination = 107
Critical Load Combination = [53] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 5: EQ+Z+E)
Pu = 231.63 kN
Mux = -196.7 kNm
Muy = 5.23 kNm
P/A = 6.24 kN/sqm
Mx/Zx = -4.54 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 286 mm
Leff = 7000 mm
SPu = 6.4 kN/sqm
Vu = SPu X (Boff - d) X L
= 99.23 kN
φVc = 1157.59 kN
Vu < φVc

One Way Shear Along B (Tension Case):

06/03/2024 21:00:44 pm 36/56


At face of Column
Soil + Surcharge Load,q = 38.45 kN/sqm
Deff = 286 mm
Leff = 7000 mm
Vu = q x Boff X L X 1.2
= 807.45 kN
φVc = 1285.04 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 147 mm

Critical Analysis Load Combination = 107


Critical Load Combination = [53] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
(LOAD 5: EQ+Z+E)
Pu = 231.63 kN
Mux = -196.7 kNm
Muy = 5.23 kNm
P/A = 6.24 kN/sqm
Mx/Zx = -4.54 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 294 mm
Leff = 2294 mm
Beff = 594 mm
Punching Perimeter = 5776 mm
Punching Area = 1698144 sqmm
SPu = Average Pressure
= 6.24 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 223.13 kN
φVn = 2895.88 kN
φVc = 1279.98 kN
No Shear
Vu < φVc Reinforcement
Required

Design For Punching Shear (Tension Case):


At face of column
Pu = -972.76 kN
Deff = 294 mm
Leff = 2000 mm
Beff = 300 mm

06/03/2024 21:00:44 pm 37/56


Punching Perimeter = 4600 mm
Punching Area = 1352400 sqmm
Vu = 972.76 kN
φVc = 2306.28 kN
Vu < φVc
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 350 X 500
= 87.5 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 107
Critical Load Combination = [53] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 5: EQ+Z+E)
Pu = 231.63 kN
A2 = 0.6 sqm
A1 = 5.78 sqm
Base Area = 37.1 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.1038
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 13710.84 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC9
Column No : C9 ( 2000mm X 300mm)
MESHED
Analysis No :
SURFACE 6-2

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

06/03/2024 21:00:44 pm 38/56


Density of Soil = 18 kN/cum
Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 6300mm X 4600mm X 350mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 253.57 kN
Soil Weight, S1 = 842.89 kN
Total Weight, W1 = F1 + S1
= 1096.46 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 152.14 kN
Soil Weight, S2 = 735.04 kN
Weight of Water (Submerged column),
= 2.28 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 884.91 kN
Offset Along L (Loff) = 2150 mm
Offset Along B (Boff) = 2150 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [5] : (LOAD 9: DL) +0.7 (LOAD 3: EQ-X+E)
Pcomb = 757.6 kN
P = Pcomb + W1
P = 1854.06 kN
Mx = -1335.43 kNm
My = 2.07 kNm
P/A = 63.98 kN/sqm
Mx/Zx = -43.89 kN/sqm
My/Zy = 0.09 kN/sqm
Maximum Soil Pressure = 107.96 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

06/03/2024 21:00:44 pm 39/56


Check For Minimum Soil Pressure:
Footing designed with loss of contact
Critical Load Combination = [33] : 0.6 (LOAD 9: DL) +0.7 (LOAD 3: EQ-
X+E)
Pcomb = 472.61 kN
P = Pcomb + W2 x 0.6
P = 1003.55 kN
Mx = -1081.92 kNm
My = 1.15 kNm
P/A = 39.01 kN/sqm
Mx/Zx = -35.56 kN/sqm
My/Zy = 0.05 kN/sqm
Minimum Soil Pressure = -0.98 kN/sqm
< 0
Uplift condition = Short edge uplift
Area of loss of contact = 0.39 sqm
= 1.338 %
< 2 %
Corner pressure P1 = -0.9 kN/sqm
Corner pressure P2 = 70.25 kN/sqm
Corner pressure P3 = 70.14 kN/sqm
Corner pressure P4 = -1 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge 1 = 0.09 m
Along long edge 2 = 0.08 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
Mux = -2059.25 kNm
Muy = 3.55 kNm
P/A = 44.43 kN/sqm
Mx/Zx = -67.67 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 302 mm
Beff = 4600 mm
SPu = 112.11 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 1191.9 kNm
Ast Rqd = 17648.64 sqmm

06/03/2024 21:00:44 pm 40/56


Ast (min) = 3220 sqmm
Ast Prv (Distributed Across Total Width) = 36 - #25 @ 135
= 17671.32 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.338 %
Weight of footing per unit area (W1) = D X Concrete Density
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 84.29 mm
Moment along L = W X (LOCL^2) X B / 2
= 0.63 kNm
Effective width = B
= 4600 mm
Pt = 0.23 %
Ast Calculated = 3220 sqmm
Ast Provided = 36 - #10 @ 115 c/c
= 2827.44 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
Mux = -2059.25 kNm
Muy = 3.55 kNm
P/A = 44.43 kN/sqm
Mx/Zx = -67.67 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 286 mm
Leff = 6300 mm
SPu = 44.59 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 649.32 kNm
Ast Rqd = 9536.08 sqmm
Ast (min) = 4410 sqmm
Ast Prv (Distributed Across Total Length) = 48 - #16 @ 135
= 9650.88 sqmm

06/03/2024 21:00:44 pm 41/56


Top Steel Along B:
Percentage loss of contact (LOC) = 1.338 %
Weight of footing per unit area (W1) = D X ConDen
= 8.75 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 29.7 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.45 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 61.55 mm
Moment along B = W X (LOCB^2) X L / 2
= 0.46 kNm
Effective width = L
= 6300 mm
Pt = 0.24 %
Ast Calculated = 4410 sqmm
Ast Provided = 59 - #10 @ 110 c/c
= 4633.86 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 302 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
Mux = -2059.25 kNm
Muy = 3.55 kNm
P/A = 44.43 kN/sqm
Mx/Zx = -67.67 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 302 mm
Beff = 4600 mm
SPu = 112.11 kN/sqm
Vu = SPu X (Loff - d) X B
= 953 kN
φVc = 983.4 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 286 mm

06/03/2024 21:00:44 pm 42/56


Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
Mux = -2059.25 kNm
Muy = 3.55 kNm
P/A = 44.43 kN/sqm
Mx/Zx = -67.67 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 286 mm
Leff = 6300 mm
SPu = 44.59 kN/sqm
Vu = SPu X (Boff - d) X L
= 523.67 kN
φVc = 1106.3 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 147 mm

Critical Analysis Load Combination = 208


Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
Mux = -2059.25 kNm
Muy = 3.55 kNm
P/A = 44.43 kN/sqm
Mx/Zx = -67.67 kN/sqm
My/Zy = 0.16 kN/sqm

Deff = 294 mm
Leff = 2294 mm
Beff = 594 mm
Punching Perimeter = 5776 mm
Punching Area = 1698144 sqmm
SPu = Average Pressure
= 44.43 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 1227.13 kN
φVn = 2895.88 kN
φVc = 1279.98 kN

06/03/2024 21:00:44 pm 43/56


No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 350 X 500
= 87.5 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 3: EQ-X+E)
Pu = 1287.68 kN
A2 = 0.6 sqm
A1 = 5.78 sqm
Base Area = 28.98 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 3.1038
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 13710.84 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC14
Column No : C14 ( 850mm X 850mm)
Analysis No : 72

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm

06/03/2024 21:00:44 pm 44/56


Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 3350mm X 3350mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 84.17 kN
Soil Weight, S1 = 321.3 kN
Total Weight, W1 = F1 + S1
= 405.47 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 50.5 kN
Soil Weight, S2 = 276.15 kN
Weight of Water (Submerged column),
= 3.11 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 323.54 kN
Offset Along L (Loff) = 1250 mm
Offset Along B (Boff) = 1250 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [6] : (LOAD 9: DL) +0.7 (LOAD 4: EQ-X-E)
Pcomb = 239.03 kN
P = Pcomb + W1
P = 644.49 kN
Mx = 108.98 kNm
My = -173.46 kNm
P/A = 57.43 kN/sqm
Mx/Zx = 17.39 kN/sqm
My/Zy = -27.68 kN/sqm
Maximum Soil Pressure = 102.51 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [34] : 0.6 (LOAD 9: DL) +0.7 (LOAD 4: EQ-X-

06/03/2024 21:00:44 pm 45/56


E)
Pcomb = 144.68 kN
P = Pcomb + W2 x 0.6
P = 338.81 kN
Mx = 102.24 kNm
My = -124.97 kNm
P/A = 34.57 kN/sqm
Mx/Zx = 16.32 kN/sqm
My/Zy = -19.94 kN/sqm
Minimum Soil Pressure = -6.07 kN/sqm
< 0
Uplift condition = Corner uplift
Area of loss of contact = 0.17 sqm
= 1.498 %
< 2 %
Corner pressure P1 = 33.79 kN/sqm
Corner pressure P2 = 66.59 kN/sqm
Corner pressure P3 = 26.53 kN/sqm
Corner pressure P4 = -6.27 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge = 0.52 m
Along short edge = 0.64 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 419.48 kN
Mux = 157.89 kNm
Muy = -278.36 kNm
P/A = 37.38 kN/sqm
Mx/Zx = 25.2 kN/sqm
My/Zy = -44.43 kN/sqm

Deff = 252 mm
Beff = 3350 mm
SPu = 62.58 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 163.77 kNm
Ast Rqd = 2683.3 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total Width) = 35 - #10 @ 100
= 2748.9 sqmm

06/03/2024 21:00:44 pm 46/56


Top Steel Along L:
Percentage loss of contact (LOC) = 1.498 %
Weight of footing per unit area (W1) = D X Concrete Density
= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 30.6 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.1 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 50.18 mm
Moment along L = W X (LOCL^2) X B / 2
= 0.16 kNm
Effective width = B
= 3350 mm
Pt = 0.24 %
Ast Calculated = 2010 sqmm
Ast Provided = 35 - #10 @ 135 c/c
= 2748.9 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 416.31 kN
Mux = 102.81 kNm
Muy = -316.36 kNm
P/A = 37.1 kN/sqm
Mx/Zx = 16.41 kN/sqm
My/Zy = -50.49 kN/sqm

Deff = 236 mm
Leff = 3350 mm
SPu = 87.59 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 229.23 kNm
Ast Rqd = 4075.16 sqmm
Ast (min) = 2010 sqmm
Ast Prv (Distributed Across Total Length) = 21 - #16 @ 170
= 4222.26 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.498 %
Weight of footing per unit area (W1) = D X ConDen

06/03/2024 21:00:44 pm 47/56


= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 30.6 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.1 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 50.18 mm
Moment along B = W X (LOCB^2) X L / 2
= 0.16 kNm
Effective width = L
= 3350 mm
Pt = 0.25 %
Ast Calculated = 2010 sqmm
Ast Provided = 26 - #10 @ 135 c/c
= 2042.04 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 209
Critical Load Combination = [74] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 4: EQ-X-E)
Pu = 419.48 kN
Mux = 157.89 kNm
Muy = -278.36 kNm
P/A = 37.38 kN/sqm
Mx/Zx = 25.2 kN/sqm
My/Zy = -44.43 kN/sqm

Deff = 252 mm
Beff = 3350 mm
SPu = 62.58 kN/sqm
Vu = SPu X (Loff - d) X B
= 209.21 kN
φVc = 495.73 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +

06/03/2024 21:00:44 pm 48/56


(LOAD 3: EQ-X+E)
Pu = 416.31 kN
Mux = 102.81 kNm
Muy = -316.36 kNm
P/A = 37.1 kN/sqm
Mx/Zx = 16.41 kN/sqm
My/Zy = -50.49 kN/sqm

Deff = 236 mm
Leff = 3350 mm
SPu = 87.59 kN/sqm
Vu = SPu X (Boff - d) X L
= 297.52 kN
φVc = 485.27 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 211


Critical Load Combination = [76] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 6: EQ+Z-E)
Pu = 424.81 kN
Mux = 103.13 kNm
Muy = -96.71 kNm
P/A = 37.85 kN/sqm
Mx/Zx = 16.46 kN/sqm
My/Zy = -15.43 kN/sqm

Deff = 244 mm
Leff = 1094 mm
Beff = 1094 mm
Punching Perimeter = 4376 mm
Punching Area = 1067744 sqmm
SPu = Average Pressure
= 37.85 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 379.5 kN
φVn = 1820.85 kN
φVc = 1201.76 kN
No Shear
Vu < φVc Reinforcement
Required

06/03/2024 21:00:44 pm 49/56


Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 300 X 500
= 75 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 211
Critical Load Combination = [76] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 6: EQ+Z-E)
Pu = 424.81 kN
A2 = 0.72 sqm
A1 = 4.2 sqm
Base Area = 11.22 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 2.4152
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 16510.14 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : NSCP C101 - 2015


Footing No : FC15
Column No : C15 ( 850mm X 850mm)
Analysis No : 73

Concrete Grade : C21


Steel Grade : Fy276
Clear Cover : 40 mm
Dfd : 2m
Dw : 1.27 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Gross Bearing Capacity = 236 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 0 %

06/03/2024 21:00:44 pm 50/56


Live Load Reduction = 0 %
Permissible area of loss of contact = 2 %

Design cross section by Consider overburden : Average pressure


pressure
Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 4350mm X 4350mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 141.92 kN
Soil Weight, S1 = 556.92 kN
Total Weight, W1 = F1 + S1
= 698.84 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 85.15 kN
Soil Weight, S2 = 478.66 kN
Weight of Water (Submerged column),
= 3.11 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 560.7 kN
Offset Along L (Loff) = 1750 mm
Offset Along B (Boff) = 1750 mm

Check For Maximum Soil Pressure:


Critical Load Combination = [5] : (LOAD 9: DL) +0.7 (LOAD 3: EQ-X+E)
Pcomb = 115.87 kN
P = Pcomb + W1
P = 814.71 kN
Mx = 59.52 kNm
My = -349.55 kNm
P/A = 43.06 kN/sqm
Mx/Zx = 4.34 kN/sqm
My/Zy = -25.48 kN/sqm
Maximum Soil Pressure = 72.87 kN/sqm
Allowable Soil Pressure = (1.25 X 200) + 36 kN/sqm
= 286 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Load Combination = [33] : 0.6 (LOAD 9: DL) +0.7 (LOAD 3: EQ-
X+E)
Pcomb = 58.1 kN
P = Pcomb + W2 x 0.6

06/03/2024 21:00:44 pm 51/56


P = 394.52 kN
Mx = 53.88 kNm
My = -275.42 kNm
P/A = 25.23 kN/sqm
Mx/Zx = 3.93 kN/sqm
My/Zy = -20.08 kN/sqm
Minimum Soil Pressure = -3.15 kN/sqm
< 0
Uplift condition = Corner uplift
Area of loss of contact = 0.32 sqm
= 1.67 %
< 2 %
Corner pressure P1 = 36.99 kN/sqm
Corner pressure P2 = 44.93 kN/sqm
Corner pressure P3 = 4.67 kN/sqm
Corner pressure P4 = -3.27 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge = 0.35 m
Along short edge = 1.79 m

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 302.21 kN
Mux = -90.07 kNm
Muy = -150.28 kNm
P/A = 15.97 kN/sqm
Mx/Zx = -6.57 kN/sqm
My/Zy = -10.95 kN/sqm

Deff = 252 mm
Beff = 4350 mm
SPu = 22.54 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 150.12 kNm
Ast Rqd = 2610 sqmm
Ast (min) = 2610 sqmm
Ast Prv (Distributed Across Total Width) = 34 - #10 @ 135
= 2670.36 sqmm

Top Steel Along L:


Percentage loss of contact (LOC) = 1.67 %

06/03/2024 21:00:44 pm 52/56


Weight of footing per unit area (W1) = D X Concrete Density
= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 30.6 kN/sqm
Total downward weigth per unit area (W) = W1 + W2
= 38.1 kN/sqm
Component of footing length subjected to
= (LOC / 100) X L
LOC (LOCL)
= 72.64 mm
Moment along L = W X (LOCL^2) X B / 2
= 0.44 kNm
Effective width = B
= 4350 mm
Pt = 0.24 %
Ast Calculated = 2610 sqmm
Ast Provided = 34 - #10 @ 135 c/c
= 2670.36 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 3: EQ-X+E)
Pu = 209.68 kN
Mux = 86.77 kNm
Muy = -543.2 kNm
P/A = 11.08 kN/sqm
Mx/Zx = 6.32 kN/sqm
My/Zy = -39.6 kN/sqm

Deff = 236 mm
Leff = 4350 mm
SPu = 50.68 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 337.55 kNm
Ast Rqd = 6036.71 sqmm
Ast (min) = 2610 sqmm
Ast Prv (Distributed Across Total Length) = 31 - #16 @ 145
= 6232.86 sqmm

Top Steel Along B:


Percentage loss of contact (LOC) = 1.67 %
Weight of footing per unit area (W1) = D X ConDen
= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 30.6 kN/sqm

06/03/2024 21:00:44 pm 53/56


Total downward weigth per unit area (W) = W1 + W2
= 38.1 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 72.64 mm
Moment along B = W X (LOCB^2) X L / 2
= 0.44 kNm
Effective width = L
= 4350 mm
Pt = 0.25 %
Ast Calculated = 2610 sqmm
Ast Provided = 34 - #10 @ 135 c/c
= 2670.36 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 252 mm
Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 302.21 kN
Mux = -90.07 kNm
Muy = -150.28 kNm
P/A = 15.97 kN/sqm
Mx/Zx = -6.57 kN/sqm
My/Zy = -10.95 kN/sqm

Deff = 252 mm
Beff = 4350 mm
SPu = 22.54 kN/sqm
Vu = SPu X (Loff - d) X B
= 146.86 kN
φVc = 632.25 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 236 mm
Critical Analysis Load Combination = 208
Critical Load Combination = [73] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 3: EQ-X+E)
Pu = 209.68 kN
Mux = 86.77 kNm

06/03/2024 21:00:44 pm 54/56


Muy = -543.2 kNm
P/A = 11.08 kN/sqm
Mx/Zx = 6.32 kN/sqm
My/Zy = -39.6 kN/sqm

Deff = 236 mm
Leff = 4350 mm
SPu = 50.68 kN/sqm
Vu = SPu X (Boff - d) X L
= 333.75 kN
φVc = 639.69 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 122 mm

Critical Analysis Load Combination = 206


Critical Load Combination = [71] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL)
+(LOAD 1: EQ+X+E)
Pu = 302.21 kN
Mux = -90.07 kNm
Muy = -150.28 kNm
P/A = 15.97 kN/sqm
Mx/Zx = -6.57 kN/sqm
My/Zy = -10.95 kN/sqm

Deff = 244 mm
Leff = 1094 mm
Beff = 1094 mm
Punching Perimeter = 4376 mm
Punching Area = 1067744 sqmm
SPu = Average Pressure
= 15.97 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 283.1 kN
φVn = 1820.85 kN
φVc = 1201.76 kN
No Shear
Vu < φVc Reinforcement
Required
Design Of Face Reinforcement
Asfr = SFR % X D X 500, mm
= 0.05% X 300 X 500

06/03/2024 21:00:44 pm 55/56


= 75 sqmm

Asfr Prv = 2-#10


= 157.08 sqmm

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 206
Critical Load Combination = [71] : 1.68 (LOAD 9: DL)
+0.5 (LOAD 10: LL) +
(LOAD 1: EQ+X+E)
Pu = 302.21 kN
A2 = 0.72 sqm
A1 = 4.2 sqm
Base Area = 18.92 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 2.4152
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X
Column Area
= 16510.14 kN
Φ1Pnb > Pu, Hence Safe.

06/03/2024 21:00:44 pm 56/56