You are on page 1of 3

CRUSHING TEST REPORT

NF EN 12390-3
CONTRACTOR Zerock Number CTR 004 MIX DESIGN
PROJECT 1st Agri Hub PART OF STRUCTURE Geolab TRIAL MIX ✘

POURING DATE 6/2/2023 ORIGIN OF CONCRETE Geolab INFORMATION

TEMPERATURE - SIZE OF SPECIMEN 16 x 32 cm NUMBER OF SPECIMEN 2

COMPOSITION OF CONCRETE CEMENT WATER SAND GRAVEL 1 GRAVEL 2 ADMIXTURE SLUMP TEST SPECIFIED

TYPE 42,5N LCDE 0/5 5/12,5 16/25 ADMIX150 SLUMP TEST 0' 9,5 cm
THEORICAL (Kg/m3) 385.12 178.78 705.98 476.54 582.44 5.78 SLUMP TEST 30'
PRATICAL - - - - - - SLUMP TEST 60'

COMPACTION Vibration CURING Water immersion

COMPRESSIVE
SPECIMEN AGE WEIGHT DENSITY LOAD
CRUSHING DATE STRENGHT FAILURE
REFERENCE
(J) (Kg) (T/m3) (KN) MPa AVERAGE
TM07 4 6/6/2023 15.74 2.45 434.43 21.61 Correct
TM08 4 6/6/2023 15.66 2.44 377.52 18.78 20.19 Correct

Remarks :

GEOLAB ENI CONGO ZEROCK


Roulé
Concassé

Correct
Incorrect
Pervibration