CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 006
Project JETTY EXTENSION AREA
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Zakem
Mix Design Trial Mix Control ✘ Information

Temperature weather /
- Size of specimen 160 x 320 mm
concrete
Pouring date 12/9/2023 Slump test at 0' -
Mix Design Code -
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type - - - - - -
Quantity(Kg/m3) - - - - - -
Part of Structure
Concrete Piping Support Foundation (Pedestal)

Number notification Date of receipt 12/13/2023

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3) Unit Average
FL046 15.52 2.51 409.34 20.36
FL047 7 12/16/2023 15.54 2.63 411.14 20.45 20.13
FL048 15.52 2.37 393.66 19.58
FL049 15.68 2.44 489.12 24.33
FL050 14 12/23/2023 15.46 2.40 507.87 25.26 23.93
FL051 15.46 2.40 446.53 22.21

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ZEROCK FRIEDLANDER ENI CONGO

Name

Signature

Date