CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 013
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature weather /
27,9 / 31,5 °C Size of specimen 160 x 320 mm
concrete
Pouring date 6/23/2023 Slump test at 0' 15 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

Oil Storage Tank / Footing / C5_Multiseed 2

30A100_RFI_24 EXT
Number notification Date of receipt 6/26/2023
30A100_RFI_55 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3) Unit Average
AH085 15.98 2.48 569.19 28.31
AH086 7 6/30/2023 16.12 2.51 608.44 30.26 28.82
AH087 16.00 2.49 560.90 27.90
AH088 16.10 2.50 787.96 39.19
AH089 28 7/21/2023 16.10 2.50 731.05 36.36 37.03
AH090 16.26 2.53 714.50 35.54
AH091
AH092 56 8/18/2023 N/A
AH093

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date