CONCRETE COMPRESSIVE STRENGHT TEST REPORT NF EN 12390-3

Number of Test Report 210


Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 23.7/ 28.2 °C Size of specimen (16 x 32 cm) x 3


Pouring date 15/11/2023 Slump test at 0' 16 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
3
Quantity(Kg/m ) 450 178.78 574 260 1018 4
Part of Structure

Heliport; Utilities shed compressor; Boiler / Footing / -Section 05; -IF03_A-B; IF04_A-B; IF05_A-B; IF06_A-B;
IF07_A-B; -TR_Air Base

Number notification 30A100_RFI_264 EXT Date of receipt 22/11/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1060 15.80 2.46 495.23 24.63
AH1061 7 22/11/2023 15.68 2.44 481.47 23.95 23.96
AH1062 15.66 2.44 468.45 23.30

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date

Number notification 30A100_RFI_..... EXT Date of receipt 22/11/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1063
AH1064 28 13/12/2023
AH1065

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature