You are on page 1of 1

NOTES

+9,000 +9,000
1. This drawing is protected under the copyright
Act. & cannot be used or reproduced
in part or in whole without authors consent.
2. All dimensions to be checked on site. Written

oor Level 3 Fourth Floor Level


dimension rules over scaled dimension.
Any discrepancy in dimensions to be reported
to Architect before any work commences.
3. All construction works to comply with the
latest K.B.S. standard codes of practice.
4. P.V. denotes permanent ventilation & must
be provided above all doors & windows except
doors to WC's.
5. All walls less 200mm thick to be reinforced

Ac Space
with hoop iron at every course.

420 6. D.P.C. denotes one layer of bituminous felt and

Gypsum drop ceiling @ 420 mm from slab


should be provided under all external walls.
7. Water meter to be 300mm above ground level.

soffit to approval
8. All r.c works to Structural Engineer's details. Depth
of foundation to be determined on site,but should
not be less than 700mm.
9. Provide one row of (600x600x50)mm precast
conc. paving slabs around the building unless
otherwise stated.
10. Heavy duty polythene sheeting and
anti-termite treatment to be provided on
under ground floor slab.
11. Plinth level to be minimum 300mm from
Shower unit complete with complete proposed parking level or existing ground level.
12. All surface beds to be casted on well

accessories to M.E's specification


compacted & well consolidated filling.
13. Depth of foundation trenches to be minimum
600mm below reduced groud level.
14. All service pipes to be minimum 450mm below
reduced ground level.
15. All inspection chambers(I.C.) within building,
drive-way & parking areas to be heavy duty,double
seal air tight covers while drains in the same areas
to be PVC pipes encased in 150mm concrete
surround.
16. All dimensions are in milimeters (mm) unless
otherwise stated.

REVISIONS

Date Descriptions

600 X800 mm bewel edged looking mirror to


2,760

M.E's specifications
2,340

Project:

PROPOSED ELITE TOWER,


PLOT LR NUMBER 209/2144/1.,
ON WESTLANDS ROAD,
WESTLANDS, NAIROBI,

WHD with complete accessories to M.E's Client:


specifications M/S. VAAL DEVELOPMENT
& INVESTMENTS
PO BOX 20227-00100
1,085

NAIROBI, KENYA
Client's signature:.......................................
850

Subject:
WC with complete accessories to M.E's INTERIOR DETAILS
specifications Title:

L[74] 03 Caretaker studio Washroom Elevation 03

Wall tiling of 300 x 300 mm finish to M.E 's


+6,000 specifications +6,000 Consultant

evel [F6] 2 L[--]07 Reception Level [F6]


Floor tiling finish of 420 x420 mm Ceramiv
tiles to approval.
L[74] 03 Caretaker studio Washroom Elevation 03

Drawn by: - Checked by: -

MANGENI AHMED

Scale on A3: 1:20 Job no.


Drg no. 132:7
Date: 12/21/2022

GSPublisherVersion 0.0.100.100

You might also like