PANEL BOX SCHEDULE OF LOADS E L E C T R I C A L

ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL


N O T E S
BE DONE IN
NO. LOADS OCPD SIZE OF WIRE
ACCORDANCE WITH THESE PLANS AND SPECIFICATION AND THE APPLICABLE
CKT. LOAD VA/CKT AMPS PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
OF VOLTS
NO. DESCRIPTION OUTLETS VA AMPS AT AWG mm²
ITS RULES & REGULATION OF THE LOCAL POWER COMPANY. THE ELECTRICAL
WORK SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED
E L E C T R I C A L S Y M B O L S PROFESSIONAL ELECTRICAL ENGINEER.
2 LO 6 300 230 1.30 15 14 TW 2 - 2.0 mm²
CONVENIENCE OUTLET S3 3-GANG SWITCH
ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE THHN
3 CO 4 800 3.13 20 12 TW 2 - 3.5 mm² UNLESS OTHERWISE INDICATED. USE PHELPS DODGE OR COLUMBIA BRAND.

WEATHER PROOF C.O.


S3w THREE- WAY SWITCH
WP THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION
4 REF 1 800 3.48 20 10 TW 2 - 5.5 mm² OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY.
PINLIGHTS/ CANNISTER GROUND

5 ACU 1 1,000 4.35 30 10 TW 2 - 5.5 mm² ALL FEEDERS AND BRANCH CIRCUIT HOMERUNS SHALL BE INSTALLED
WALL LAMPS SERVICE ENTRANCE AS INDICATED ON THE PLANS. BRANCH CIRCUIT HOMERUN WIRES SHALL
BE INSTALLED IN INDIVIDUAL HOMERUNS CONDUITS.

6 SPARE 1 1,000 4.35 30 10 TW 2 - 5.5 mm²


INCANDESCENT CIRCUIT BREAKER ANY DISCREPANCY IN LOCATION & RATING OF EQUIPMENT AND/OR APPARATUS
TO SHALL BE VERIFIED WITH THE OWNER OR HIS AUTHORIZE REPRESENTATIVE
AND CHANGES SHALL BE DONE ACCORDINGLY.
7 CIRCUIT HOMERUN
FLOURESCENT
ALL MATERIALS AND EQUIPMENT TO BE USE AND INSTALLED SHALL BE
8 REFRIGERATOR/RANGE CABLE
BRAND NEW, OF THE APPROVE TYPE FOR THE LOCATION & PURPOSE INTENDED.

ALL POWER AND CONVENIENCE OUTLETS SHALL BE GROUNDING TYPES.


TOTAL 3,900 VA 16.61 AMP THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS :
AIR CONDITION UNIT TELEPHONE
ACU

TOTAL CONNECTED LOAD: 16.61 AMP LIGHT SWITCHES = 1.40 MTRS. ABOVE FINISH FLOOR LINE
S1 1- GANG SWITCH M KILOWATT HOUR METER CONVENIENCE OUTLETS = 0.30M. ABOVE FINISH FLOOR LINE
DEMAND FACTOR: 80% PANEL BOARD AND CABINETS = 1.40 ABOVE FINISH FLOOR LINE

S2 2- GANG SWITCH PANEL BOARD


DEMAND LOAD: 13.28 AMP PB

WIRING IN CONDUIT WIRING IN CONDUIT USE 2-8.0 mm2 TW


PB PROTECTION: 2P, 40 AT MCCB CONCEALED IN WALL CONCEALED IN GROUND 2 WIRES 60 HERTZ

SERVICE ENTRANCE: USE 2-8.0 mm2 TW IN 34" RSC PIPE

USE 43"" RSC PIPE

5.00 USE - 34"


ENTRANCE CAP

VERIFY HEIGHT
2 1
MAIN METER BOX M
LO 6
f S1f
d
5 15AT 60AT
PB 4 3 WEATHER PROOF
5.00

5.00

4 S3cde
REF
20 AT 20 AT
CO 4
60AT CIRCUIT BREAKER
c a 3 SPARE
30 AT
6 5
30 AT
ACU
ENCLOSURE

S2ab 8 7
VERIFY HEIGHT

b
GRND.

0.50 4.50 USE -3/4" PVC


M PB DIAGRAM CONDUIT PIPE
SCALE: N.D.T.S

NAT. GRND. LN.

LIGHTING & POWER LAYOUT


SCALE : 1:100 MTRS.

RISER DIAGRAM
SCALE: N.D.T.S

SCHOOL SUBJECT PLATE TITLE STUDENT PLATE NO. PLATE SCORE

UNIVERSITY OF PANGASINAN ARC 041 CAGUIOA, CLARENCE R.


PHINMA EDUCATIONAL NETWORK SPECIFICATION WRITING & QUANTITY SURVEYING ONE (1) BEDROM BUNGALOW
DEPARTMENT

DEPARTMENT OF ARCHITECTURE
SCHEDULE / SECTION
UP-FC1-BSAR4-
FOR
SPECIFICATION WRITING & QUANTITY SURVEYING
INSTRUCTOR
4
COLLEGE OF ENGINEERING AND ARCHITECTURE BLCK 02 AR. J.I.S.B