Classification of Building
• Group A: Residential
• Group B: Assembly
• Group C: Educational
• Group E: Commercial
• Group F: Office
• Group G: Industries
• Group H: Storage
5/23/2022 2
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 3
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Exit Doors
• exit door, inclusive of frame, shall be less than 1m in width
and 2.1m in height
5/23/2022 4
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Exit Doors
5/23/2022 5
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Exit Doors
5/23/2022 6
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Exit Doors
5/23/2022 7
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 8
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 9
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 10
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Plinth
Minimum plinth height shall be 450mm from the existing road
level for all buildings.
• Height
• 2.4m measured from the surface of the floor to the lowest point
of the ceiling [bottom of slab]
Light &Ventilations
5/23/2022 12
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 13
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Lift
• at least two lifts shall be made for high rise building [above
8 stories or 25m in height].
5/23/2022 14
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Lift
5/23/2022 15
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Basements
5/23/2022 16
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Parking
• The minimum height clearance for indoor parking space
shall not be less than 2.2m.
• For common parking, area allocated for each car shall not
be less than 2.5m X 4.5m.
• Parking area allocated for each bike and scooter shall not
be less than 1.25 sq.m while the same for the cycle shall
not be less than 1 sq.m
Parking
5/23/2022 18
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Medium Rise:
5/23/2022 19
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 20
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
• Ramps
• Minimum gradient of1:8 [7 degrees]for the difference in
height not more than 450mm
• Minimum gradient of 1:12 [5 degrees]for the difference
in height more than 450mm
5/23/2022 21
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 22
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 23
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
✓900mm wide
✓1600mm deep
5/23/2022 24
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
Lifts
• The minimum required size of disabled accessible lift
are provided under part 2.2.4
• Height of the controls from the floor level of the lift car
shall be at most 1066mm
5/23/2022 25
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 27
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 28
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 29
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 30
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 31
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
5/23/2022 32
TRAINING PROGRAM ON REVISED NEPAL NATIONAL BUILDING CODE AND
OTHER BYELAWS
THANK YOU
5/23/2022 33