You are on page 1of 9

C-FIX 1.117.0.

0
Database version
2023.6.16.16.1
Date
17/07/2023

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Injection system FIS EM plus
Injection resin FIS EM Plus 390 S
Fixing element Threaded rod FIS A M 16 x 200 8.8,
zinc plated steel, Property Class 8.8
Calculated anchorage 100 mm
depth

Design Data Determined by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Input data

Design method Design method ENSO Bonded


Base material C35/45, EN 206
Concrete condition Non-cracked, dry hole
Temperature range 43 °C long term temperature, 72 °C short term temperature
Reinforcement Normal or no reinforcement. Straight edge reinforcement
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Annular gap filled
Type of loading Permanent-Transient/Static
Base plate location Base plate with non bearing layer, e.g. grout pad., g = 50 mm
calc. lever arm l = 58 mm
Degree of restraint αM = 2.0
Mortar compression strength: 40.0 N/mm²
Base plate geometry 340 mm x 440 mm x 15 mm
Profile type Rectangular hollow tube cold formed (200100x10)

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 -4.20 0.00 7.10 -21.60 0.00 0.00 Permanent-Transient/Static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 0.00 1.78 0.00 1.78
2 0.00 1.78 0.00 1.78
3 28.90 1.78 0.00 1.78
4 28.90 1.78 0.00 1.78

max. concrete compressive strain : 0.17 ‰


max. concrete compressive stress : 5.9 N/mm²
Resulting tensile actions : 57.80 kN , X/Y position ( 0 / -160 )
Resulting compression actions : 62.00 kN , X/Y position ( 0 / 199 )

Resistance to tension loads

Proof Action Capacity Utilisation βN


kN kN %
Steel failure * 28.90 84.00 34.4
Combined pull-out and concrete cone failure 57.80 93.32 61.9
Concrete cone failure 57.80 74.17 77.9

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

* Most unfavourable anchor

Steel failure

( NRd,s )

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
126.00 1.50 84.00 28.90 34.4

βN,s
Anchor no. % Group N° Decisive Beta
1 0.0 1 βN,s;1
2 0.0 2 βN,s;2
3 34.4 3 βN,s;3
4 34.4 4 βN,s;4

Combined pull-out and concrete cone failure

( NRd,p )

Eq. (5.2)

Eq. (5.2a)

Eq. (7.14a)

Eq. (7.15)

Eq. (7.16)

Eq. (5.2e)

Eq. (5.2f)

Eq. (5.2g)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Eq. (5.2h)

Eq. (5.2i)

NRk,p γMp NRd,p NSd βN,p


kN kN kN %
139.98 1.50 93.32 57.80 61.9

βN,p
Anchor no. % Group N° Decisive Beta
3, 4 61.9 1 βN,p;1

Concrete cone failure

( NRd,c )

Eq. (5.3)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

Eq. (5.3e)

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
111.25 1.50 74.17 57.80 77.9

βN,c
Anchor no. % Group N° Decisive Beta
3, 4 77.9 1 βN,c;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure with lever arm * 1.78 4.86 36.6
Concrete pry-out failure 3.55 148.34 2.4
Concrete edge failure 7.10 47.72 14.9

* Most unfavourable anchor

Steel failure with lever arm

( VRd,s )

Eq. (5.6/a)

VRk,s γMs VRd,s VSd βVs


kN kN kN %
6.07 1.25 4.86 1.78 36.6

βVs
Anchor no. % Group N° Decisive Beta
1 24.0 1 βVs;1
2 24.0 2 βVs;2
3 36.6 3 βVs;3
4 36.6 4 βVs;4

Concrete pry-out failure

( VRd,cp )

Eq. (5.7a)

Eq. (5.3)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Eq. (5.3e)

VRk,cp γMcp VRd,cp VSd βV,cp


kN kN kN %
222.51 1.50 148.34 3.55 2.4

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 2.4 1 βV,cp;1
3, 4 2.4 2 βV,cp;2

Concrete edge failure

( VRd,c )

Eq. (5.8)

Eq. (5.8a)

Eq. (5.8b/c)

Eq. (5.8e)

Eq. (5.8f)

Eq. (10.2-5f)

Eq. (5.8h)

VRk,c γMc VRd,c VSd βV,c


kN kN kN %
71.59 1.50 47.72 7.10 14.9

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

βV,c
Anchor no. % Group N° Decisive Beta
1, 2 8.4 1 βV,c;1
3, 4 14.9 2 βV,c;2

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 34.4 Steel failure with lever arm * 36.6
Combined pull-out and concrete cone failure 61.9 Concrete pry-out failure 2.4
Concrete cone failure 77.9 Concrete edge failure 14.9

* Most unfavourable anchor

Resistance to combined tensile and shear loads


Utilisation steel
Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

Utilisation concrete Proof successful


Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 15 mm

Profile type Rectangular hollow tube cold formed (200100x10)

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Installation data
Anchor
Anchor system fischer Injection system FIS EM
plus
Injection resin FIS EM Plus 390 S (other cartridge Art.-No. 544154
sizes available)
Fixing element Threaded rod FIS A M 16 x 200 8.8, Art.-No. 517939
zinc plated steel, Property Class 8.8

Accessories FIS MR Plus Art.-No. 545853


FIS Extension tube 9mm Art.-No. 48983
Dispenser FIS DM S Art.-No. 511118
Compressed-air cleaning tool Art.-No. 93286
compressed air (oil-free), min. 6 bar By job site
BSD 18 Art.-No. 1493
SDS Chuck with internal thread M8 Art.-No. 530332
Quattric II 18/200/250 Art.-No. 549956
or alternatively
FHD 18/320/450 Art.-No. 546600
Hammer drilling with or without
suction
Alternative cartdriges FIS EM Plus 585 S Art.-No. 544166
FIS EM Plus 1500 S Art.-No. 544173
The shown cartdriges are
alternative to the highlighted
one above with the same approval
number.

Installation details
Thread diameter M 16
Drill hole diameter d0 = 18 mm
Drill hole depth h2 = 165 mm
Calculated anchorage hef = 100 mm
depth
Drilling method Hammer drilling
Drill hole cleaning 2 times blowing (compressed air),
2 times brushing,
2 times blowing (compressed air)
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Maximum torque Tinst,max = 60.0 Nm
Socket size 24 mm
Base plate thickness t = 15 mm
Grout thickness g ≤ 50 mm
Total fixing thickness tfix ≤ 65 mm
Tfix,max
Volume of resin per drill 20 ml/10 scale divisions
hole

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8
C-FIX 1.117.0.0
Database version
2023.6.16.16.1
Date
17/07/2023

Base plate details


Base plate material A36
Base plate thickness t = 15 mm
Clearance hole in base df=20 mm
plate

Attachment
Profile type Rectangular hollow tube
cold formed (200100x10)

Anchor coordinates

x y
Anchor no. mm mm
1 -110 160
2 110 160
3 -110 -160
4 110 -160

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 9