You are on page 1of 74

Pos : 2 /Allgemei n/ATEX ( Standar d-Modul e)/(CD) D ec kblatt - ATEX-Ausführung @ 21\mod_1464176558716_41.

doc m @ 239472 @ @ 1

Pos : 4 /D osi ergeräte/D ec kblatt/(CD) D ec kblatt D okID _453 - DD SR V3 (neu) @ 21\mod_1461832101460_0.doc m @ 235304 @ @ 1

ATEX execution
Supplementary information in the technical
description “The ATEX execution“ has to be
observed!

OPERATING INSTRUCTIONS
(DDW-) DDSR XX
Save this document for future reference
Pos : 7 /Allgemei n/Spezi elleM odule (Forts etzung, Leerz eile us w.)/--------------------- Seitenumbruc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1
Pos : 8.1 /Allgemei n/Impressum/(CD) Impr ess um - T eil 1 (Betriebs anl eitung) @ 17\mod_1455199186473_41.doc m @ 212570 @ @ 1

Imprint

Device assignment
Device names: (DDW-) DDSR xx
Device variant: HYD ATEX

Document
Document status: Original
Type of document: Operating instructions
File designation: e2120453
Document ID: 453
Revision: 2.0.1
Date: 16-06-21
Editor: Brabender Technologie GmbH & Co. KG
Copyright: © 2016, Brabender Technologie GmbH & Co. KG

Pos : 8.2 /Allgemei n/Impressum/(CD) Impr ess um - T eil 2 (Sc hutz ver mer k gemäß DIN EN 16016) @ 17\mod_1455200027460_41.doc m @ 212628 @ @ 1

Copyright (according to DIN EN ISO 16016)


No part of this document may be reproduced, transmitted, sold or disclosed
without prior permission. In the event of contraventions, compensation for
damages will be claimed. All rights reserved with regard to patent claims or
submission of design or utility patent.
Pos : 8.3 /Allgemei n/Impressum/(CD) Impr ess um - T eil 3 (Bestandteil des Gerätes) @ 17\mod_1455200143059_41.doc m @ 212656 @ @ 1

Save this document for future reference


The document is an integral part of the device stated above. It has to be saved
completely, ready to hand and close to the device for future reference.
Pos : 8.4 /Allgemei n/Spezi elleM odule (Forts etz ung, Leerzeil e us w.)/--------------------- Seitenumbruc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

2 Safety ©Operating instructions (DDW-) DDSR xx


Pos : 8.5 /Allgemei n/I mpressum/(CD) Impr ess um - T eil 4 (Inhalts verz eichnis) @ 17\mod_1455200241435_41.doc m @ 212684 @ @ 1

Table of contents

Imprint ........................................................................................................ 2
1. Safety ................................................................................................... 5
Use of the device.......................................................................................... 6
Safety instructions........................................................................................ 8
Specifications for the operating licence of the device.......................... 8
Qualification of the operating personnel ............................................. 8
Dangerous contact voltages on the device........................................... 8
Disconnection of the device ................................................................. 9
Discharge of residual energy storages .................................................. 9
Earthing of the device ........................................................................... 9
Sound level............................................................................................ 9
Sharp-edged components................................................................... 10
Specifications for the operation of a screw feeder ............................ 10
Specifications for the operation of an agitator................................... 10
Warnings on the device ...................................................................... 11
Residual dangers ........................................................................................ 12
2. The description of the device .............................................................. 14
Description of the construction of the device ........................................... 15
Component groups of the device............................................................... 18
The hopper.......................................................................................... 18
Feeding organ and feed drive ............................................................. 21
The weighing of the device ................................................................. 24
Technical data ............................................................................................ 26
3. Mounting ........................................................................................... 27
Mounting instructions................................................................................ 28
Place of the installation.............................................................................. 29
Mounting work........................................................................................... 30
Installation on site .............................................................................. 30
Connection inlet/outlet ...................................................................... 30
Connection ventilation/deaeration .................................................... 31
Electrical mounting work ........................................................................... 32
4. Commissioning ................................................................................... 40
Notes on commissioning ............................................................................ 41

©Operating instructions (DDW-) DDSR xx Safety 3


Process of commissioning .......................................................................... 42
Step 1: Tests on the device ............................................................ 42
Step 2: Connection of supply media .............................................. 42
Step 3: Verification of the sense of rotation ................................. 42
Step 4: Verification and adjustment of the weighing .................... 43
Step 5: Determination of the feed rate ......................................... 45
Product feeding .......................................................................................... 47
Step 6: Adaptation of the feed rate............................................... 49
5. Decommissioning................................................................................ 50
6. Alarm cut-outs .................................................................................... 51
Causes of malfunction ................................................................................ 52
7. Maintenance ...................................................................................... 54
Notes on carrying out maintenance .......................................................... 55
List of components ..................................................................................... 56
Care and inspection ................................................................................... 58
Cleaning of the device ................................................................................ 60
Specifications for cleaning .................................................................. 60
Description of the cleaning processes ................................................ 61
Assembly/disassembly of individual components ..................................... 63
Disassembly twin screw ...................................................................... 63
Vertical outlet with screw bearing ...................................................... 64
Assembly twin screw .......................................................................... 64
Disassembly of the agitator ................................................................ 65
Assembly of the agitator ..................................................................... 66
Exchange of shaft sealing rings ........................................................... 67
Adjustment of speed monitoring ........................................................ 70
8. Storage and disposal ........................................................................... 71
Storage of the device, of individual assemblies ......................................... 72
Disposal of the device, of individual components ..................................... 73
Index ......................................................................................................... 74

Pos : 10 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

4 Safety ©Operating instructions (DDW-) DDSR xx


Pos : 11 /Allgemein/Übersc hriften Sic herheit/(CD) Ü bersc hrift 1 - Sic her hei t @ 17\mod_1455200510026_41.doc m @ 212740 @ 1 @ 1

1. Safety

Pos : 13 /D osierger äte/Sic herheit/(CD) 1. Seite - Inhalt Sic her hei t @ 17\mod_1455200636780_41.doc m @ 212768 @ @ 1

This chapter describes the use of the device and the safety instructions for the
use of the device.

Content of the chapter “safety”:


Subject Page
Use of the device 6
Safety instructions 8
Residual danger 12
Pos : 15 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Safety 5


Pos : 16 /Allgemein/Übersc hriften Sic herheit/(CD) Ü bersc hrift 2 - Die Verwendung des Ger ätes @ 17\mod_1455201556748_41.doc m @ 212796 @ 2 @ 1

Use of the device

Pos : 18 /D osierger äte/Sic herheit/D okID _453 - (DD W-) DD SR/Ver wendung - Bes ti mmungsgemäß e Verwendung DDSR @ 5\mod_1369213869591_41.doc m @ 93816 @ @ 1

Intended purpose The “DDSR xx“ is a feeder for the feeding of bulk solids that can be fed by
means of a twin screw (feeding device) and a trough agitator. The product is
filled into the hopper, from there it is conveyed into the agitator trough, where
an agitator rotates vertically to provide a better filling ratio of the screw. The
rotating screw transports the product to the outlet of the device from where it
falls freely into the downstream equipment. The screw is driven by a drive
motor (= feed drive) that is controlled by means of a suitable drive controller.
The working point of the device, the feed rate (= product quantity/unit of time)
is adjusted by means of the determination of the speed of the feed drive. The
trough agitator is driven by the 2nd drive motor of the device and during the
feeding operation, the standard system operation is with a constant speed.

Pos : 20 /D osierger äte/Sic herheit/Ver wendung - Geeignete Produkte für Schnec ke+Rühr wer k @ 2\mod_1348033005803_41.doc m @ 62787 @ @ 1

Appropriate products Bulk solids (no liquids) with the following product characteristics are
appropriate for being discharged/fed with the device:
• Suitable size of product particles
• Appropriate flowability
• Free from contamination, foreign bodies etc.
• No ignition capability due to friction or strokes
• No explosive characteristics
• No change of the product characteristics due to
- the feeding operation
- the operation of an agitator
• No inadmissibly high wear of the machine parts in contact with the
product

Pos : 23 /D osierger äte/Sic herheit/(CD) Ver wendung - Vorgaben für den Eins atz bereic h ATEX @ 22\mod_1465969446503_41.doc m @ 241313 @ @ 1

Specifications The standard dimensioning of the device requires the following environmental
for the use and operating data for the field of application:

Temperature: 0°C to +40°C


Humidity: up to 85% without condensation
Medium: Air or inert gas
Wind/draught: < 0.3 m/s
Max. underpressure/overpressure: 2 mbar (20mm water column)
Product temperature: 0°C to +40°C
Voltage supply: AC 230/400V
Pos : 25 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

6 Safety ©Operating instructions (DDW-) DDSR xx


Use of the device, continuation

Pos : 26 /D osierger äte/Sic herheit/Ver wendung - Benötigte Baugruppen für den Betrieb @ 1\mod_1336986445173_41.doc m @ 47422 @ @ 1

Required component Electrical assemblies are required for the following control functions (minimum
groups for the operation requirement):
• Start/stop of the operation of the device
• Determination of the working point of the device (= speed setting)
Pos : 27 /D osierger äte/Sic herheit/(CD) Ver wendung - Benötigte Baugruppen für den Betri eb (Er wei ter ung Ver wi egung @ 17\mod_1455203361213_41.doc m @ 212937 @ @ 1

Advanced demands during weighing


The weighing of the device requires other or additional assemblies for its
operation:
• An additional evaluation unit is required, if the weighing is employed as
filling level monitoring.
• A feeding controller type Congrav® or a system with comparable functions
is required for the operation of a loss-in-weight feeder (“DDW-…”).

Pos : 29 /D osierger äte/Sic herheit/(CD) Ver wendung - Anpass ung an den kundensei tigen Ei nsatz ber eich @ 17\mod_1455203480864_41.doc m @ 212965 @ @ 1

Adaptation to the The device is dimensioned according to the application conditions known
application on site when awarding the contract. They result from the customer’s indications
concerning
• the products employed and their characteristics,
• the environmental and operating conditions,
• the desired feed rate range.

Adaptations to the field of application on site are listed in the order


confirmation and are a component of the intended use of the device.

Modification of the field of application on site


If the field of application on site is changed, a new release of the operation by
the manufacturer is required.

Pos : 31 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Safety 7


Pos : 32 /Allgemein/Übersc hriften Sic herheit/(CD) Ü bersc hrift 2 - Sic her hei tshi nweise @ 17\mod_1455203572470_41.doc m @ 212993 @ 2 @ 1

Safety instructions

Pos : 34 /D osierger äte/Sic herheit/(CD) Sicherheit - Vorgaben für die Betriebs erlaubnis des Ger ätes @ 17\mod_1455203696103_41.doc m @ 213021 @ 3 @ 1

Specifications for the operating licence of the device


Any operation shall be permitted only if the following specifications have been
complied with:
• The indications on the operating instruction have been complied with.
• Mounting, commissioning have been carried out correctly.
• The device must only be used for its intended purpose.
• The device is maintained regularly.
• For necessary repairs original spare parts of the manufacturer or spare
parts with identical technical characteristics have to be employed (has to
be enabled by the manufacturer).

Pos : 36 /D osierger äte/Sic herheit/(CD) Sicherheit - Qualifi kati on Bedienpers onal @ 17\mod_1455203777210_41.doc m @ 213049 @ 3 @ 1

Qualification of the operating personnel


The following qualifications are required for the operating personnel:
• Trained on the device and its operation
• Authorised to carry out the required operations
• Knowledge of the regulations concerning the operator protection
• Knowledge of the actual operating conditions as far as the device and its
environment are concerned

Pos : 38 /D osierger äte/Sic herheit/(CD) Sicherheit - Berührungsgefährliche Spannungen am Ger ät @ 17\mod_1455203864743_41.doc m @ 213077 @ 3 @ 1

Dangerous contact voltages on the device


Dangerous contact voltages are required for the operation of the device. The
following specifications have to be respected for the protection of the
operating personnel:
• The device must not be operated with freely accessible terminals.
• Before commencing any work on the electrical connections, you must first
disconnect the device from the mains.
• The device must not be operated with damaged electrical components.
Damaged component groups have to be repaired or exchanged immediately.
Pos : 39 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

8 Safety ©Operating instructions (DDW-) DDSR xx


Safety instructions, continuation

Pos : 41 /D osierger äte/Sic herheit/(CD) Sicherheit - Definiti on Freisc halten @ 17\mod_1455203984960_41.docm @ 213105 @ 3 @ 1

Disconnection of the device


Below you will find the term "disconnection". "Disconnection" means:
• Disconnect the device from all supply media.
Definition! • Protection against unauthorised reconnection.
• Discharge all kinds of energy stocks (manually or due to sufficient dwell
times).

Pos : 43 /D osierger äte/Sic herheit/(CD) Sicherheit - Entl eer ung von R estenergies peic her @ 17\mod_1455204057736_41.doc m @ 213133 @ 3 @ 1

Discharge of residual energy storages


Depending on the execution different storages of residual energy may be
mounted to the device. The table lists measures for the discharge of energy
storages:
Type Component (example) Measure
Electric Condenser, coil Observe the discharge time
Mechanic Spring Relieving
Pneumatic Compressed air line Deaeration
Thermic Dissipator, surface Observe the cooling time

Pos : 45 /D osierger äte/Sic herheit/(CD) Sicherheit - Er dung des Gerätes @ 17\mod_1455204453440_41.doc m @ 213161 @ 3 @ 1

Earthing of the device


The device must only be operated with a correct earthing. The main earth
connection point is connected to the equipotential bonding on site in a
standard-compliant manner. Earth connections between the device and
Marking of the main earth assembled components that have been mounted in our works must not be
connection point interrupted or removed on site.

Pos : 47 /D osierger äte/Sic herheit/(CD) Sicherheit - Geräusc hpegel @ 17\mod_1455204522675_41.doc m @ 213189 @ 3 @ 1

Sound level
The sound level of the device is < 70dB (acc. to DIN45635)

Pos : 48 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Safety 9


Safety instructions, continuation

Pos : 50 /D osierger äte/Sic herheit/(CD) Sicherheit - Sc harfkantige Bauteile ( Sc hnec ke+Rühr wer k) @ 17\mod_1455204685074_41.doc m @ 213217 @ 3 @ 1

Sharp-edged components
The device has sharp-edged components that present a danger of injury (cuts)
even if the drive is not on:
• the vertically rotating agitator
• the screw

Pos : 52 /D osierger äte/Sic herheit/(CD) Sicherheit - Vorgaben für den Betrieb einer Schnec kendosier ung @ 17\mod_1455204747367_41.doc m @ 213245 @ 3 @ 1

Specifications for the operation of a screw feeder


• A screw must only be operated with a mounted screw pipe. A freely
rotating screw has considerable potential for injury.
• A screw must only be operated with a screw pipe with appropriate
dimensions. An inappropriate combination screw-screw pipe may cause
operational failures and damage to the device.
• The combination screw-screw pipe must only be employed for suitable
product. If you employ an inappropriate product (e.g. too large grain size)
this might cause operational failures and damage to the device.
• If the screw is not filled with product the screw must only be operated
with low speed. A higher speed might lead to radial deflections of the
screw and cause damage to the device.

Pos : 53 /D osierger äte/Sic herheit/(CD) Sicherheit - Vorgaben für den Betrieb eines R ührwer ks @ 21\mod_1461832537928_41.doc m @ 235331 @ 3 @ 1

Specifications for the operation of an agitator


• In case of a feeding device that is equipped with an agitator an operation
without agitator is not allowed, because
- an agitator that is not rotating in the product range impedes the free
product flow.
- an uneven filling ratio of the feeding device and bridging in the
product zone might cause interruptions of operation.
• For a special agitator design with a controlled speed (speed controller) the
speed settings have to guarantee a safe operation of the device.
Pos : 55 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

10 Safety ©Operating instructions (DDW-) DDSR xx


Safety instructions, continuation

Pos : 56 /D osierger äte/Sic herheit/(CD) Sicherheit - War nhi nweis e am Ger ät @ 17\mod_1455204870282_41.doc m @ 213273 @ 3 @ 1

Warnings on the device


Sources of danger are marked by the standardised warning symbols on the
device. Additionally the following warning symbols are employed:

Before the start of any work the device has to be disconnected from the mains
and protected against unauthorised reconnection.
In case of non-respect there is a considerable danger of injuries caused by
Disconnect the device
dangerous voltages.
from the mains

Marks the allowed sense of rotation for the drive motor.


Allowed sense of In case of non-respect the rotating component groups risk to be torn out of
rotation their fastening during the operation.

Pos : 58 /D osierger äte/Sic herheit/D okID _445 - (DD W-) MT/(CD) Sicherheit - War nhi nweis e am Ger ät R ührwer k @ 17\mod_1455204944883_41.doc m @ 213301 @ @ 1

Do not put arms/fingers into the rotating agitator and use long-shafted gloves
during work on the agitator at standstill.
In case of non-respect there is a considerable danger of injuries caused by the
Disconnect the device
sharp-edged agitator.
from the mains

Pos : 60 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Safety 11


Pos : 61 /Allgemein/Übersc hriften Sic herheit/(CD) Ü bersc hrift 2 - Res tgefahren @ 17\mod_1455205045090_41.doc m @ 213329 @ 2 @ 1

Residual dangers

Pos : 63 /D osierger äte/Sic herheit/(CD) R estg efahr - Einl eitung @ 1\mod_1336654135295_41.doc m @ 46625 @ @ 1

This paragraph describes the possible dangers that might occur in an


admissible field of application and that might be caused by external influences,
e.g. carelessness or connections to equipment on site.
Pos : 65 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/-----> Leerz eile (F ormat: verstec kter T ext) <----- @ 4\mod_1358837888992_0.doc m @ 79738 @ @ 1

Pos : 67 /D osierger äte/Sic herheit/(CD) R estg efahr - Fr emdkör per @ 17\mod_1455205235164_41.docm @ 213357 @ @ 1

Foreign bodies Danger: Foreign bodies in the product area of the device
Effects: • Operational failures
• Damage of the device
Measures: • Employ clean product
• Circumspection/special care must be taken when
working on the device
Pos : 68 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/- -----> Leerz eile (F or mat: T ext) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 70 /D osierger äte/Sic herheit/(CD) R estg efahr - Produkts tau @ 18\mod_1455205397540_41.doc m @ 213385 @ @ 1

Product jam Danger: No free product flow


Effects: • Operational failures
• Damage of the device
Measures: • The free product flow into the device and out of the
device has to be guaranteed
• Stop the operation of the device if connected
equipment on site is troubled
Pos : 71 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/- -----> Leerz eile (F or mat: T ext) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 73 /D osierger äte/Sic herheit/(CD) R estg efahr - Produktwec hsel @ 18\mod_1455205503188_41.doc m @ 213413 @ @ 1

Product change Danger: Wrong equipment of the device


Effects: • Operational failures
• Damage of the device
Measures: • Operation only with approved products
• Management of product/device equipment
• Conversion has to be carried out completely/with
special care
Pos : 74 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/- -----> Leerz eile (F or mat: T ext) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 76 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

12 Safety ©Operating instructions (DDW-) DDSR xx


Residual dangers, continuation

Pos : 77 /D osierger äte/Sic herheit/(CD) R estg efahr - Nic ht ausr eichende Be-/Entlüftung @ 18\mod_1455205628712_41.doc m @ 213441 @ @ 1

Insufficient Danger: No pressure compensation in the product vessel


aeration/deaeration Effects: • The product discharge (feeding) causes a negative
pressure in the vessel.
• Product refilling causes an overpressure in the vessel.
• Pressure loads may cause operational failures or
damage of the device.
Measures: • The device must only be operated with an adequate
aeration.
• Cleaning intervals of aeration filter units have to be
adjusted to the degree of contamination.
• Stop the operation of the device if connected
equipment on site (e.g. vacuum systems) is troubled.
Pos : 78 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/- -----> Leerz eile (F or mat: T ext) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 79 /D osierger äte/Sic herheit/(CD) R estg efahr - Sc hnelllös bare Verbindung en mit Sicherheitss chalter @ 21\mod_1463474929149_41.doc m @ 237242 @ @ 1

Optional quick release When using quick release fastenings for the fastening of a component the
fastenings position of this component has to be monitored by a safety switch, if the
disassembly/the opening of the component causes a hazard for the operating
personnel by opening of the component (e.g. by freely rotating components).
During the disassembly/opening of the component the operating release of
the device is locked by means of the safety switch (electric interlocking chain)
and thus prevents the hazard. The safety switch detects/monitors
• the allowed mounting position of the component,
• but not the correct mounting of the connection.

Danger: Wrong understanding of security of the operating


personnel
Effects: Improper use
Measures: Train the operating personnel. Quick release fastenings
always have to be mounted correctly. I.e.:
• tighten with sufficient attraction force.
• always tighten completely (all connections).

Pos : 81 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Safety 13


Pos : 82 /Allgemein/Übersc hriften Gerätebeschr eibung/(CD) Überschrift 1 - Di e Besc hrei bung des Gerätes @ 18\mod_1455205787572_41.doc m @ 213469 @ 1 @ 1

2. The description of the device

Pos : 84 /D osierger äte/Gerätebesc hrei bung/(CD) 1. Seite - Inhalt Ger ätebesc hrei bung @ 18\mod_1455205992968_41.doc m @ 213497 @ @ 1

This chapter describes the construction and the function of the device and of
individual component groups.

Content of the chapter “device descriptions”:


Subject Page
Construction of the device 15
Component groups of the device 18
Technical data 26
Pos : 86 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/--------------------- Seitenumbr uc h -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

14 The description of the device ©Operating instructions (DDW-) DDSR xx


Pos : 87 /Allgemein/Übersc hriften Gerätebeschr eibung/(CD) Überschrift 2 - Bes chr eibung des Ger äteaufbaus @ 18\mod_1455259270003_41.doc m @ 213534 @ 2 @ 1

Description of the construction of the device

Pos : 90 /D osierger äte/Gerätebesc hrei bung/DokID _453 - (DD W-) DDSR xx (20 < xx < 80)/(CD) Aufbau - Abbil dung DDSR 40B HYD ( neu) @ 21\mod_1461833276338_0.doc m @ 235359 @ @ 1

Pos : 94 /D osierger äte/Gerätebesc hrei bung/DokID _453 - (DD W-) DDSR xx (20 < xx < 80)/(CD) Aufbau - Legende DD SR40 V3 (neu) @ 21\mod_1461833992403_41.doc m @ 235440 @ @ 1

Legend The illustration shows the design of a DDSR40B. The markings in the
illustration have the following meaning:
No Meaning
1 Product supply on site
2 Flexible connection
3 Connecting branch, refilling
4 Hopper cover
5 Drive motor agitator

©Operating instructions (DDW-) DDSR xx The description of the device 15


6 Drive motor screw
7 Junction box
8 Agitator trough
9 Proximity switch (speed monitoring)
10 Sealing of twin-shaft gearing
11 Mounting plate
12 Weighing system
13 Outlet, downstream connection point
14 Flexible connection of vertical outlet
15 Vertical outlet
16 Cover vertical outlet
17 Twin screw
18 Front agitator trough (demountable; “cleaning hole“)
19 Agitator
20 Hopper
21 Filter bag (ventilation/exhaust)
Pos : 97 /Allgemein/Speziell eModul e (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abs chnittforts etzung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

16 The description of the device ©Operating instructions (DDW-) DDSR xx


Description of the construction of the device, continuation

Pos : 98 /D osierger äte/Gerätebesc hrei bung/DokID _453 - (DD W-) DDSR xx (20 < xx < 80)/(CD) Aufbau - Erläuterung z ur Baugröße @ 21\mod_1463552405853_41.doc m @ 237362 @ @ 1

Explanation on the The agitator trough has two zones, the actual
construction size and agitator zone (a) and the screw zone (b). The
the execution indication of the construction size “xx“ in the
identification “DDSR xx“ means that the agitators
and screws of the series “xx“ may be employed
for this device.
The identification “xxB“ marks an execution with
a screw of the series “xx“ and an agitator trough
of the next larger series.

Example:
Device Agitator/trough Screw
DDSR40 Series 40 Series 40
DDSR40B Series 60 Series 40

Pos : 100 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx The description of the device 17


Pos : 101 /Allgemein/Ü berschriften Ger ätebesc hrei bung/(CD) Ü bersc hrift 2 - Die Baugruppen des Ger ätes @ 18\mod_1455259642907_41.doc m @ 213616 @ 2 @ 1

Component groups of the device

Pos : 103 /Allgemein/Ü berschriften Ger ätebesc hrei bung/Ü bers chrift 3 - Der Behälter @ 1\mod_1336740811312_41.doc m @ 47027 @ 3 @ 1

The hopper
Pos : 105 /Dosi ergeräte/Gerätebes chr eibung/Behälter - Ei nlei tung @ 1\mod_1336740864120_41.doc m @ 47053 @ @ 1

The hopper stores the product to be fed, in a next step the product is
conveyed to the feeding unit.

Pos : 106 /Dosi ergeräte/Gerätebes chr eibung/Behälter - Sic herheits einric htung @ 1\mod_1336741028034_41.doc m @ 47079 @ @ 1

Safety equipment The hopper is a protective device. It prevents the operator from putting
hands/fingers into the rotating component groups of the device. The protective
function is obtained by different measures (combinations are possible):
• the size of the hopper
• a mounted safety grid
• a safe screwing of the hopper or the hopper cover.
Pos : 108 /Dosi erg eräte/Gerätebes chr eibung/(CD) Behälter - Vorsic ht fr eiz ugänglic her Produktber eich @ 18\mod_1455260070212_41.doc m @ 213644 @ @ 1

Freely accessible product zone (open hopper)


» The operating personnel risks to get injured by rotating components
when reaching into the product zone.
Attention
» Foreign objects might enter the product zone and cause damage to
the device.
» Damage of the device and the environment caused by dust or other
product characteristics.
The operation of the device is only allowed, if
- hopper and hopper cover have been mounted correctly,
- existing connections have been carried out correctly and are
operationally reliable.
Pos : 110 /Dosi ergeräte/Gerätebes chr eibung/(CD) Behälter - Sc hutzgitter allgemei n @ 18\mod_1455260213468_41.doc m @ 213672 @ @ 1

Protective grid The hopper is equipped with a protective grid, if


• the hopper cover is not screwed tightly (e.g. loose and/or flap function)
and
• the construction size of the hopper cannot prevent from reaching into
rotating components.

The protective grid does not replace a hopper cover


The operation of the device is only allowed if the hopper cover is closed. The
protective grid does not offer sufficient protection against foreign objects and
soiling.
Pos : 112 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.) /(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

18 The description of the device ©Operating instructions (DDW-) DDSR xx


Component groups of the device, continuation

The hopper, continuation


Pos : 113 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/(CD Behälter - Befes tigung V1 @ 21\mod_1463557947739_41.doc m @ 237389 @ @ 1

Fastening Executions for the fastening of the hopper or of the hopper cover:
Type of construction Type of fastening
Standard Screwing
Optional Clamping lock for quick/easy opening

Sealing
Sealing material is employed between the components. The sealing is adjusted
via the tensioning force of the screwing or of the clamping lock.

Pos : 114 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/(CD) Behälter - Befestigung V3 (neu) @ 21\mod_1461837911559_41.doc m @ 235467 @ @ 1

Fastening Hopper
As a rule, the hopper is fixed by a clamp connection to the screw/agitator
trough. A sealing material is employed between both components, if the
tightening force of the screw connection is sufficient the connection is tight.

Hopper cover
A clamp connection permits to fasten the hopper cover to the hopper. A
sealing material is employed between both components, if the tightening force
of the screw connection is sufficient the connection is tight.
Exception :
Hopper cover fits loosely

Pos : 115 /Dosi ergeräte/Gerätebes chr eibung/D okID_458 - (DD W-) F W40/Behälter - Sicherheit: Positi onsüber wac hung @ 10\mod_1406204758518_41.doc m @ 144882 @ @ 1

Safety: With the use of a quick-release clamping fastener or a corresponding


Position monitoring application the correct mounting position will be monitored (e.g. magnetic
switch). During the electrical assembly of the device the position monitoring
signal is integrated into an electrical interlocking chain for the operating
release of the device.

Pos : 116 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

©Operating instructions (DDW-) DDSR xx The description of the device 19


Component groups of the device, continuation

The hopper, continuation


Pos : 117 /Dosi ergeräte/Gerätebes chr eibung/Behälter - Sic herheit: Mec hanisc he Verriegel ung @ 14\mod_1435210404729_41.doc m @ 195721 @ @ 1

Safety: A quick-release clamping connection may also be equipped with a mechanical


Mechanical locking lock. This lock permits to fix the clamping connection after closing and thus
prevents inadvertent opening of the clamping connection. The execution and
the use of a mechanical lock is a function of the corresponding type of
clamping connection and may be combined as a function of the corresponding
type of clamping connection with an electrical position monitoring.

Pos : 119 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

20 The description of the device ©Operating instructions (DDW-) DDSR xx


Component groups of the device, continuation

Pos : 120 /Allgemein/Ü berschriften Ger ätebesc hrei bung/Ü bers chrift 3 - Dosier organ und Dosierantri eb @ 1\mod_1336973989337_41.doc m @ 47211 @ 3 @ 1

Feeding organ and feed drive


Pos : 123 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/(CD) D osi erorgan, D osi erantrieb - Abbildung V3 ( neu) @ 21\mod_1461844795032_0.doc m @ 235548 @ @ 1

Pos : 125 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - D osi erantrieb AC-Motor @ 2\mod_1339147829964_41.doc m @ 53058 @ @ 1

Feed drive A threephase motor (1) is employed as feed drive. The threephase motor is
operated by means of a suitable drive controller (frequency converter). The
adjustment of the motor to the drive controller and the field of application is
made by means of the parameterisation of the drive controller. Thus, the
parameterisation is part of the dimensioning of the device.
The working point of the device is adjusted by means of the determination of
the operating speed (=speed specification) of the feed drive. The speed
specification is a function of the execution of the drive controller and is made
by means of an analogue or serial control signal.

Pos : 126 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - Dr ehzahlüberwac hung (indukt. NS) @ 2\mod_1339150639196_41.doc m @ 53085 @ @ 1

Speed monitoring The speed monitoring is provided by an inductive proximity switch (2) the
pulses of which are evaluated by a suitable electrical unit. The speed
monitoring has the function to monitor the specified limit values, minimum
and maximum speed.

Observe the execution!


• Standard for a loss-in-weight feeder (“DDW-“)
• Optional for all other executions
Pos : 128 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx The description of the device 21


Component groups of the device, continuation

Pos : 129 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - Sc hnec ke (+ R ührwer k) @ 4\mod_1363865159889_41.doc m @ 87132 @ @ 1

Screw The product is conveyed by means of a screw (3) that is driven by the feed
(feeding device) drive. The rotating movement of the screw generates a product feed that
conveys the product out of the agitator trough (6) to the end of the screw pipe
(4). The dimensioning of the screw (type, pitch, diameter etc.) in combination
with the dimensioning of the screw pipe determines the field of application
and work of the feeding device.

Pos : 130 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - Tr ogrührwer k (s epar ater Antrieb) @ 4\mod_1361877943464_41.docm @ 83107 @ @ 1

Trough agitator A vertically rotating agitator (7) that permits to improve the filling ratio of the
feeding device rotates in the agitator trough. The agitator is driven by a
separate drive motor (8) and rotates with a constant speed.

Pos : 131 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - Tr ogrührwer k ( Sonder aus führung: Dr ehz ahlgereg elt) @ 5\mod_1371105896758_41.doc m @ 96465 @ @ 1

Special design
As a special design the drive motor is speed controlled via a drive controller.
The adjustment of the motor to the drive controller and the field of application
is made by means of the parameterisation of the drive controller. Thus, the
parameterisation is part of the dimensioning of the device.

Pos : 132 /Dosi ergeräte/Gerätebes chr eibung/D osi erorgan, D osi erantrieb - Verti kal er Ausl auf Schutz ei nrichtung @ 4\mod_1358870828387_41.doc m @ 79898 @ @ 1

Vertical outlet The vertical outlet (5) as end piece of the screw pipe is to be considered as
protective equipment and prevents from reaching into the rotating screw.
With an execution that is not equipped with a vertical outlet the protection has
to be achieved by the connection/installation on site (e.g. safety distance).

Pos : 133 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/D osi erorgan, D osi erantrieb - das Getriebe @ 9\mod_1401102212997_41.doc m @ 132629 @ @ 1

The gear The drive shafts of the twin screw (3) are driven by the drive motor (1) via a
twin-shaft gearing. The transmission of the gear determines the working range
of the device and is part of the dimensioning of the device. The gear features
lifetime lubrication and a mounting flange connects the gear to the screw
trough where the twin screw operates.

Pos : 134 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

22 The description of the device ©Operating instructions (DDW-) DDSR xx


Component groups of the device, continuation

Feeding organ and feed drive, continuation


Pos : 136 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/(CD) D osi erorgan, D osi erantrieb - Abdic htung Antriebs well en V3 ( neu) @ 21\mod_1461848649086_41.doc m @ 235629 @ @ 1

Radial packing rings on Up to size “40“ the devices are equipped with a twin-shaft gearing (1), that is
the twin-shaft gearing connected to the trough via the sealing plate (2).

The sealing of the drive shafts is made


by means of two radial packing rings
(3) that are inserted in the sealing
plate. In case of a leakage the product
leaks out along the drive shaft behind
the radial packing rings and collects
below the product outlet opening (4).

Bearing and sealing of The drive shafts are supported in a bearing block
the drive shafts (2). The sealing in the bearing block is executed as
follows
• a radial packing ring (1) for the sealing of the
drive shaft for the agitator.
• Two radial packing rings (3) for the sealing of
the drive shafts of the twin screw.

In case of leaking shaft sealings product leaks out


via the product outlet openings (4). The product
falls downward and forms a deposit below the
bearing block in zone (A) (with an agitator the
product falls on the cover of the twin-shaft
gearing).
Pos : 137 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/D osi erorgan, D osi erantrieb - Kaltleiter, T emper aturüber wac hung @ 9\mod_1400767811676_41.doc m @ 132160 @ @ 1

Temperature monitoring In case of a demand for a temperature monitoring of the drive shafts a PTC
resistor (K) is mounted and connected to an external evaluation unit.
Pos : 139 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx The description of the device 23


Component groups of the device, continuation

Pos : 140 /Allgemein/Ü berschriften Ger ätebesc hrei bung/Ü bers chrift 3 - Die Ver wiegung des Gerätes @ 1\mod_1337003622751_41.doc m @ 47528 @ 3 @ 1

The weighing of the device


Pos : 143 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/(CD) Ver wi egung - Abbildung V3 (neu) @ 21\mod_1461916358173_0.doc m @ 235716 @ @ 1

Pos : 145 /Dosi ergeräte/Gerätebes chr eibung/D okID_453 - (DD W-) DD SR xx (20 < xx < 80)/Verwi egung - Aufbau und Funktion @ 5\mod_1370941674392_41.doc m @ 95856 @ @ 1

Design and function For weighing, the feeding device is mounted on a weighing system. The
weighing system permits to sense the product weight, it is then available as
electrical weighing signal for further evaluation. The product weight is
computed from the difference (actual weight – empty weight of the device).
The most important fields of application for weighing are
• the execution as loss-in-weight feeder (DDW-….)
• the monitoring of hopper filling level (MS-…)

Pos : 150 /Dosi ergeräte/Gerätebes chr eibung/(CD) Ver wi egung - Sc hutz einric htung: Trans portsic herung V1 @ 18\mod_1455261353626_41.doc m @ 213840 @ @ 1

Protective equipment: The transport catch (6) connects the base plate (8) with the mounting plate (9)
Transport catch and thus und relieves the weighing system (7). It protects the weighing system
against inadmissible loads and torsions during a transport and/or during
mounting/maintenance work.

Transport catches
Execution - are red metal elements the number and shape of which
are a function of the design of the device.
Use - are always completely fastened and loosened.
- are kept within reach of the place of use of the device.
Fastening - are fastened before the start of any work on the device
or a transport of the device.
Loosening - are loosened before the start of the operation.

Pos : 152 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

24 The description of the device ©Operating instructions (DDW-) DDSR xx


Component groups of the device, continuation

The weighing of the device, continuation


Pos : 153 /Dosi ergeräte/Gerätebes chr eibung/Verwi egung - Schutz einric htung: Vi brati onsdämpfung ( m. M ass eplatte) @ 1\mod_1337068199043_41.doc m @ 47691 @ @ 1

Protective equipment: Vibration isolation mounting pads (5) are mounted below the base plate (8),
Vibration isolation they permit to absorb disturbing influences at the place of the installation.
mounting pads If this measure is not sufficient, the device has to be mounted on a mass plate.
The absorption effect of the combination of vibration isolation and heavy load
is considerably higher.
Pos : 155 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/-----> Leerzeil e (For mat: vers tec kter Text) <----- @ 4\mod_1358837888992_0.doc m @ 79738 @ @ 1

Pos : 157 /Allg emein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx The description of the device 25


Pos : 158 /Allgemein/Ü berschriften T ec hnis che D aten/(CD) Übersc hrift 2 - T ec hnische D aten @ 18\mod_1455261815701_41.doc m @ 213868 @ 2 @ 1

Technical data

Pos : 161 /Dosi ergeräte/Sic her hei t/(CD) Ver wendung - Vorgaben für den Ei ns atz ber eich AT EX @ 22\mod_1465969446503_41.doc m @ 241313 @ @ 1

Specifications The standard dimensioning of the device requires the following environmental
for the use and operating data for the field of application:

Temperature: 0°C to +40°C


Humidity: up to 85% without condensation
Medium: Air or inert gas
Wind/draught: < 0.3 m/s
Max. underpressure/overpressure: 2 mbar (20mm water column)
Product temperature: 0°C to +40°C
Voltage supply: AC 230/400V
Pos : 162 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 164 /Dosi ergeräte/Gerätebes chr eibung/(CD) T ec hnis che D aten - D osierger ät D oppel-Sc hnec ke ( d=1mm) @ 20\mod_1460473321703_41.doc m @ 223061 @ @ 1

Feeding device Data for the execution of the device:

Sound level: < 70dB(A)


Feeding device: Twin screw
Drive: ac drive
Drive controller: Frequency converter
Operating range: 2% - 99% x nominal speed
Speed monitoring: Pulse scanning via proximity switch
Scanning distance: d = 1 mm

Pos : 166 /Dosi ergeräte/Gerätebes chr eibung/T ec hnische D aten - T ypensc hild @ 9\mod_1396429355087_41.doc m @ 129458 @ @ 1

Nameplate The nameplate indicates the type of device, the machine number and the year
of construction of the device.
Clear marking of the device:
Pos : 168 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1
Machine number

26 The description of the device ©Operating instructions (DDW-) DDSR xx


Pos : 169 /Allgemein/Ü berschriften M ontag ear bei ten/(CD) Ü bersc hrift 1 - Montage @ 18\mod_1455262104728_41.doc m @ 213924 @ 1 @ 1

3. Mounting

Pos : 171 /Dosi ergeräte/Montage/(CD) 1. Seite - Inhalt Montage des Ger ätes @ 18\mod_1455262217853_41.doc m @ 213952 @ @ 1

This chapter describes the mounting work required to make the system ready
for operation.

The descriptions were formulated in a very general manner and only take into
account the standard assemblies of the manufacturer.

Content of the chapter “mounting”:


Subject Page
Mounting instructions 28
Place of the installation 29
Mounting work 30
Electrical mounting work 32
Pos : 173 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 27


Pos : 174 /Allgemein/Ü berschriften M ontag ear bei ten/(CD) Ü bersc hrift 2 - Montagehinweis e @ 20\mod_1458814824491_41.doc m @ 221286 @ 2 @ 1

Mounting instructions

Pos : 176 /Dosi ergeräte/Montage/M ontag ehi nweise - Ac htung akti ve Versorgungs medi en @ 1\mod_1337088095962_41.doc m @ 48067 @ @ 1

Connection work with supply media being active


» Danger caused by dangerous life voltage
» Danger caused by uncontrolled actions during the connection of the
Attention
supply medium
Therefore
- Connections shall only be made to connection points that are
disconnected from the corresponding supply medium.

Pos : 178 /Dosi ergeräte/Montage/M ontag ehi nweise - Montageaus führung @ 9\mod_1396440111803_41.docm @ 129493 @ @ 1

Assembly execution Make sure to observe the following points for mounting:
• Horizontal alignment
• Max. 2mm offset for the connection of the device to equipment on site
• Connection of the device to an equipment on site via a flexible connection
The following connections are allowed (direction of view is the direction of the
product flow):
• From a smaller cross-section to a larger cross-section
• Both product lines have the same cross-section.

Pos : 180 /Dosi ergeräte/Montage/M ontag ehi nweise - Montageunter brec hung @ 1\mod_1337149955238_41.docm @ 48410 @ @ 1

Interruption of To be observed in case of an interruption of mounting:


mounting
• Protect the device against foreign bodies.
• Mark that the device is partly mounted.
• Protect the device against an unauthorised commissioning.

Pos : 182 /Dosi ergeräte/Montage/(CD) M ontag ehi nweis e - M ontagehilfs mittel @ 18\mod_1455262813551_41.doc m @ 213980 @ @ 1

Mounting tools The following auxiliaries are required for mounting:


Work equipment Auxiliary equipment:
General locksmith’s tools Cover tarpaulin
General electrician’s tools Lining sheets
Level Cleaning rag
Suitable detergents

Pos : 184 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

28 Mounting ©Operating instructions (DDW-) DDSR xx


Pos : 185 /Allgemein/Ü berschriften M ontag ear bei ten/(CD) Ü bersc hrift 2 - Der Aufstellungs ort @ 18\mod_1455262977776_41.doc m @ 214008 @ 2 @ 1

Place of the installation

Pos : 187 /Dosi ergeräte/Montage/Aufstellungsort - Eig ensc haften @ 1\mod_1337090202416_41.doc m @ 48145 @ @ 1

Characteristics The place of the installation has the following characteristics:


• corresponds to the valid standards
• stable, dry, free from vibrations and sufficiently suitable to take weight
• protected against weather conditions
• permissible ambient temperature
• free from oils, fats, gases, vapours etc.
• no explosive atmosphere

Pos : 189 /Dosi ergeräte/Montage/Aufstellungsort - Auss tattung @ 1\mod_1337090618165_41.doc m @ 48171 @ @ 1

Equipment The place of the installation has to be equipped as follows:


• sufficient illumination
• sufficiently dimensioned for all necessary workflow paths
• possibilities for connecting the required supply media

Pos : 191 /Dosi ergeräte/Montage/Aufstellungsort - Trans por t z um Aufstellungs ort @ 1\mod_1337091181947_41.doc m @ 48197 @ @ 1

Transport to the place of Suitable lifting equipment (fork lift truck, crane, etc.) permits to transport the
the installation following items to the place of the installation.
Pos : 193 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 29


Pos : 195 /Allgemein/Ü berschriften M ontag ear bei ten/(CD) Ü bersc hrift 2 - Montagearbeiten @ 18\mod_1455263162784_41.doc m @ 214036 @ 2 @ 1

Mounting work

Pos : 197 /Dosi ergeräte /Montage/M ontag ear bei ten - Hi nweis fl exibl e Anbindung @ 1\mod_1337146873564_41.doc m @ 48384 @ @ 1

Flexible connection
The connection of solid/rigid product/media lines must not cause any
disturbances of operation. Therefore the connection to equipment on site has
to be carried out in a flexible manner between a downstream connection point
on the device and a fixed point on site. The description of the connection of
the inlet/outlet shows the principle of the flexible connection.

Pos : 199 /Dosi ergeräte/Montage/M ontag ear bei ten - Aufstellung (Ü3) @ 4\mod_1361356030395_41.doc m @ 82332 @ 3 @ 1

Installation on site
Assembly of the device at the place of the installation:
1. Transport the device to the place of the installation.
2. Align the device at the place of the installation.
3. Align the device in horizontal position.
4. Screw the device to the floor construction.

Pos : 201 /Dosi ergeräte/Montage/(CD) M ontag ear beiten - Anschl uss Ei n-/Auslauf - T eil1 (Ü 3) @ 18\mod_1455263963688_41.doc m @ 214064 @ 3 @ 1

Connection inlet/outlet
The connection of the inlet/outlet of the device to equipment on site has to be
executed in a flexible manner. The materials for a flexible connection are
delivered with the device.
The illustration shows the construction principle of a flexible connection of two
product line ends to a step bellow:

No Meaning
1 Line 1
2 Clamping ring 1
3 Step bellow
4 Clamping ring 2
5 Line 2
Pos : 202 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

30 Mounting ©Operating instructions (DDW-) DDSR xx


Mounting work, continuation

Connection inlet/outlet, continuation


Pos : 203 /Dosi ergeräte/Montage/M ontag ear bei ten - Anschl uss Ei n-/Ausl auf - T eil2 @ 9\mod_1396441922303_41.doc m @ 129605 @ @ 1

1. Slide the step bellow over line1.


2. Fix the step bellow by means of fastening strap1.
3. Slide fastening strap2 over the step bellow.
4. Slide the step bellow over line2.
5. Fix the step bellow by means of fastening strap2.
Pos : 204 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 205 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 207 /Dosi ergeräte/Montage/M ontag ear bei ten - Anschl uss Be-/Entl üftung @ 8\mod_1391604429472_41.doc m @ 125534 @ 3 @ 1

Connection ventilation/deaeration
As standard, a filter bag is supplied for the
ventilation/deaeration of the device. The filter bag is
pulled over the vent pipe and fixed by means of a
clamping fastener. Due to its design the filter bag can
stand upright without further auxiliaries. The
venting/deaeration is made via the fabric surface of
the filter bag.

Pos : 208 /Dosi ergeräte/Montage/M ontag ear bei ten - Be- /Entl üftung Alternati ve Abs augung @ 4\mod_1358926610417_41.doc m @ 80037 @ @ 1

On-site vacuum system


As an alternative the aeration/deaeration can be provided by a vacuum system
on site. The connection of the vacuum system to the vent pipe is made in a
flexible manner (e.g. sleeve) or without contact (e.g. suction funnel).

The suction must not interfere with the feeding operation!


If the suction is too strong it might cause an operational failure. Therefore, the
following has to be observed for the adjustment of the suction:
As strong as necessary and as light as possible!

Pos : 210 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 31


Pos : 211 /Allgemein/Ü berschriften M ontag ear bei ten/(CD) Ü bersc hrift 2 - El ektrisc he Montagearbeiten @ 18\mod_1455266520093_41.doc m @ 214092 @ 2 @ 1

Electrical mounting work

Pos : 213 /Dosi ergeräte/Montage/E-Montagearbeiten - Ac htung berührungsgefährliche Spannung @ 1\mod_1337154364433_41.docm @ 48488 @ @ 1

Voltages that are hazardous upon contact


» Danger caused by dangerous life voltages
» Danger caused by improper execution of the work
Attention
Therefore
- Employ trained electrical personnel.
- After the connection work the junction boxes have to be closed
correctly.

Pos : 215 /Dosi ergeräte/Montage/E-Montagearbeiten - Kl emmenkästen @ 4\mod_1361366654211_41.doc m @ 82439 @ @ 1

Junction boxes The connection of the electrical assemblies in junction boxes is provided in our
works in order to facilitate the connection on site. The junction boxes are
marked “-JB n” (n= 1, 2, 3,…). The following assignments apply to the junction
boxes
• The marking ”-JB 1“is reserved for the junction box of the weighing system
and is only employed, if the device is mounted on a weighing system.
• The electrical assemblies of the device are connected in the junction boxes
“-JB 2,3,4,…“. The number is adapted to demand.
• In case of a standard execution the terminals are connected according to
the determined terminal assignment of the junction boxes.
• Executions that deviate from the standard are described in the specific
wiring plans related to the order. Due to the specific execution a deviation
from the standard terminal assignments is possible. The wiring plans are a
separate document and complement the operating instructions.

Pos : 218 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

32 Mounting ©Operating instructions (DDW-) DDSR xx


Electrical mounting work, continuation

Pos : 219 /Steuer ung en/ISC pl us - Sys tem/Montage/M ontag e Arbeiten - Metallisc he Kabel verschr aubung en @ 0\mod_1317894743356_41.doc m @ 12256 @ @ 1

Cable screwings The following illustration shows the correct use of the metallic cable screwings.

The cable is isolated according to the illustration and inserted into the cable
screwing. The screening (A) is pushed over the metal cap (M), then the
screwing is tightened.

Pos : 221 /Dosi ergeräte/Montage/E-Montagearbeiten - Aufbau einer Verrieg elungs kette @ 4\mod_1361429762268_41.doc m @ 82558 @ @ 1

Establishment of an An interlocking chain is an electrical cabling,


interlocking chain
• that takes into account additional start conditions for the start enable of
the feeding operation (e.g. closed circuit breaker or operational readiness
of the connected equipment).
• that stops the feeding operation immediately, if one operating condition is
not complied with (e.g. tripping of a circuit breaker).

The implementation of an interlocking chain is a function of the hardware used


on site (programmable logic controller, relay etc.) and has to comply with the
applicable regulations concerning the safety of man and machine. When using
a feeding controller type Congrav® the feeding is operated via the feeding
controller. Depending on the hardware execution of the Congrav® different
possibilities are available for the establishment of an interlocking chain.

Pos : 223 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 33


Electrical mounting work, continuation

Pos : 225 /Dosi ergeräte/Montage/(CD) E-Montagearbeiten - Ansc hluss pl an und Geräteausführ ung ( ohne ISC) @ 21\mod_1461916860964_41.doc m @ 235743 @ @ 1

Wiring plan and Please find below the different wiring plans for the electrical connection of the
execution of the device device. Each wiring plan is designed for a specific execution of the device.

Connection plan Execution of the device


Congrav® Type: Loss-in-weight feeder (DDW-…)
Operation: Feeding controller Congrav® (e.g. CB plus)
Characteristic: Congrav® in control cabinet
Volumetric Type: Standard device
Operation: Start/stop + OP specification
Characteristic: OP specification via potentiometer or
control signal (e.g. 0-10VDC)
Pos : 226 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

34 Mounting ©Operating instructions (DDW-) DDSR xx


Electrical mounting work, continuation

Pos : 230 /Steuer ung en/Standard- Anschl uss pläne/Ansc hl usspl äne - CBplus mit 1 D osi ergerät + 1 Motor @ 12\mod_1420700522120_41.doc m @ 175643 @ @ 1

Wiring plan CB plus

Pos : 232 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 35


Electrical mounting work, continuation

Pos : 234 /Steuer ung en/Standard- Anschl uss pläne/(CD) Ansc hlusspl äne - Ansc hlus spl an Legende (C Bpl us) 1. Sc hal tschr ank @ 18\mod_1455271484666_41.doc m @ 214204 @ @ 1

Wiring plan CBplus Identifications (“ident.”) used in the connection plan “CBplus“ :
legend
Components in the control cabinet/box:
Ident. Meaning
F Protection
FC Frequency converter
CB plus Feeding controller CB plus
DI Digital inputs (DI1-4)
DO Digital outputs (DO1-4)
K2,3,4 External relay in the control cabinet
GND Ground potential
Pos : 235 /Steuer ung en/Standard- Anschl uss pläne/(CD) Ansc hlusspl äne - Ansc hlus spl an Legende (C Bpl us) 2. D osi ergerät @ 18\mod_1455271639568_41.doc m @ 214232 @ @ 1

Components of the metering feeder:


Ident. Meaning
JB1 Junction box: connection of the load cell
JB2 Junction box: connection of assemblies, supply
M1 Drive motor of the feeding device
B2 Load cell
B5 Speed monitoring
Pos : 237 /Steuer ung en/Standard- Anschl uss pläne/(CD) Ansc hlusspl äne - Ansc hlus spl an Legende (C Bpl us) 3. Bedi enung @ 18\mod_1455267614746_41.doc m @ 214148 @ @ 1

Components for the operation:


Marking Meaning
OP1 T Operating unit Congrav® OP1 T
Pos : 239 /Dosi ergeräte/Montage/(CD) E-Montagearbeiten - Legende Kabelfarben @ 18\mod_1455271783967_41.doc m @ 214260 @ @ 1

Cable colours Abbreviations (Abbr.) used for the cable colours in the wiring plans:
Abbr. Colour Abbr. Colour Abbr. Colour
BN Brown GN Green BU/WH Blue/White
BK Black GY Grey WH/BU White/Blue
BU Blue PK Rose GNYE Green/yellow
WH White RD Red
VT Violet YE Yellow

Pos : 240 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

36 Mounting ©Operating instructions (DDW-) DDSR xx


Electrical mounting work, continuation

Pos : 244 /Dosi ergeräte/Montage/E-Montagearbeiten - Ansc hlus spl an Rühr wer ks motor @ 4\mod_1361371625432_41.doc m @ 82523 @ @ 1

Connection of separate The separate agitator motor (-M2) is


agitator motor connected via a motor protection relay (-
Q1) to the voltage supply. The electrical
cabling of the contactor coil (-K1M) permits
to actuate the agitator motor. The cabling
is executed in such a manner that
- the agitator drive starts, if the feeding
operation is started and all conditions
for an existent interlocking chain (e.g.
circuit breaker) have been complied
with.
- the agitator motor stops, if the feeding
operation is stopped.

Pos : 246 /Dosi ergeräte/Montage/E-Montagearbeiten - Ansc hlus spl an vol umetrisch @ 4\mod_1363872163112_41.doc m @ 87240 @ @ 1

Connection plan In “volumetric” operation the


volumetric feed drive (M) is controlled via a
frequency converter (A2) that
permits to adjust the operating
speed via a potentiometer (P1).
The device will feed with this
operating speed as soon as it is
enabled (switch S1). The
frequency converter is no
component of the device but is
mounted in a control cabinet or
similar and connected on the
device to the feed drive via the
junction box (JB2).

Pos : 247 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 37


38 Mounting ©Operating instructions (DDW-) DDSR xx
Electrical mounting work, continuation

Pos : 248 /Dosi ergerä te/Montage/(CD) E-Montagearbeiten - Ansc hluss pl an vol umetrisch Legende @ 18\mod_1455272263360_41.docm @ 214288 @ @ 1

Legend Explanation of the markings employed (“ident.“):


Ident. Meaning
Q1 Main switch, maintenance switch
F1 Fuse
S1 Switch “operating release”
P1 Potentiometer “speed specification“
A2 Frequency converter type “FC-Vx“
A2.1 Frequency converter I/O module “standard“
JB2 Junction box on the device
M Feed drive
B3 PTC thermistor (if available)
Pos : 250 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Mounting 39


Pos : 251 /Allgemein/Ü berschriften Inbetriebnahme/(CD) Überschrift 1 - Inbetriebnahme @ 18\mod_1455272424075_41.doc m @ 214316 @ 1 @ 1

4. Commissioning

Pos : 253 /Dosi ergeräte/Inbetriebnahme/(CD) 1. Seite - Inhalt Inbetriebnahme des Ger ätes @ 18\mod_1455272509876_41.doc m @ 214344 @ @ 1

This chapter describes the activities required for the commissioning of the device.

The descriptions were formulated in a very general manner and only take into
account the standard assemblies of the manufacturer.

Content of the chapter “commissioning”:

Subject Page
Notes on commissioning 41
Commissioning sequence 42
Product feeding 47
Pos : 255 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

40 Commissioning ©Operating instructions (DDW-) DDSR xx


Pos : 256 /Allgemein/Ü berschriften Inbetriebnahme/(CD) Überschrift 2 - Hi nweis e für die Inbetriebnahme @ 18\mod_1455272710059_41.doc m @ 214372 @ 2 @ 1

Notes on commissioning

Pos : 258 /Dosi ergeräte/Inbetriebnahme/(CD) InbetriebnahmeHinweise - War nhi nweis gefährliche Pr odukteigensc haften @ 19\mod_1457452574735_41.doc m @ 219391 @ @ 1

Product with hazardous characteristics


» Danger due to leakages or malfunctions of the device
Danger Therefore
- Employ a replacement product with non-hazardous, otherwise
identical product characteristics.
- Take all necessary security measures, if no replacement product is
available.
Pos : 260 /Dosi ergeräte/Inbetriebnahme/Inbetri eb nahmeHinweis e - Pr oduktdosi erung @ 14\mod_1434106641660_41.doc m @ 193196 @ @ 1

Product feeding During commissioning the product feeding is started for the computation of
the feed rate of the device. An active product feeding requires
• a sufficient product quantity,
• free product flow into/out of the device,
• a receptacle for collecting the product quantity that has been fed. For this
purpose two possibilities are available
1. Feeding into downstream parts of the installation
2. Feeding into a collecting receptacle (possibly requires an additional
bypass line)

Pos : 262 /Dosi ergeräte/Inbetriebnahme/Inbetri ebnahmeHinweis e - U nterbrechnung der Inbetriebnahme @ 1\mod_1337593978614_41.doc m @ 48786 @ @ 1

Interruption of Commissioning is interrupted, if


commissioning
• there are problems during commissioning.
• it is required to correct the assembly of the device or other connected
equipment.

Corrections of the assembly


In case of corrections of the assembly make sure to observe the specifications
and notes on the mounting of the device.
Pos : 264 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Commissioning 41


Pos : 265 /Allgemein/Ü berschriften Inbetriebnahme/(CD) Überschrift 2 - Abl auf der Inbetriebnahme @ 18\mod_1455272900929_41.doc m @ 214400 @ 2 @ 1

Process of commissioning

Pos : 267 /Allgemein/Ü berschriften Inbetriebnahme/Übersc hrift 3 - Prüfungen am Gerät @ 1\mod_1337599806399_41.docm @ 48891 @ 3 @ 1

Step 1: Tests on the device


Pos : 269 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Pr üfung enGer ät Prüfpunkte @ 1\mod_1337605002030_41.doc m @ 48917 @ @ 1

Commissioning must only be carried out, if the following specifications are duly
fulfilled.
1. Has all mounting work been finished?
2. Have all supply media been connected?
3. Are all supply media available as required?
4. Sufficient product quantities are available.
5. All foreign bodies and contaminations have been removed.
6. All necessary measures to ensure the safety of operations have been
taken.
7. The device and the other equipment required are ready for operation.
8. Sample measurements can be carried out.

Pos : 271 /Allgemein/Ü berschriften Inbetriebnahme/Übersc hrift 3 - Vers orgungsmedien z usc hal ten @ 1\mod_1337613686310_41.doc m @ 49050 @ 3 @ 1

Step 2: Connection of supply media


Pos : 273 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Vers orgungs medi en zuschalten @ 1\mod_1337613757838_41.doc m @ 49077 @ @ 1

1. Connect all supply media.


2. Warm up of approx. 30 min.
3. Continue the commissioning.

Pos : 275 /Allgemein/Ü berschriften Inbetriebnahme/Übersc hrift 3 - Prüfungen der Dr ehric htung @ 1\mod_1337607373039_41.doc m @ 48943 @ 3 @ 1

Step 3: Verification of the sense of rotation


Pos : 277 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Pr üfungDrehrichtung Drehs trommotor @ 1\mod_1337607471774_41.doc m @ 48970 @ @ 1

Fehler!Fehler! A direction arrow marks the prescribed sense of rotation on each drive motor.
Unbekanntes During this step the sense of rotation is checked by means of a visual check.
Schalterargument. 1. Enter a small speed (~10%).
2. Start the device and check the sense of rotation.
3. Stop the device.

In case of a wrong sense of rotation the sense of rotation has to be changed.


4. Switch off the power supply.
5. Protection against unauthorised reconnection.
6. Exchange two of the connection lines (U, V, W), (e.g. U, V).
7. Switch on the voltage supply.

Pos : 279 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

42 Commissioning ©Operating instructions (DDW-) DDSR xx


Process of commissioning, continuation

Pos : 280 /Allgemein/Ü berschriften Inbetriebnahme/(CD) Überschrift 3 - Prüfungen und Abgleic h der Ver wiegung @ 1\mod_1337613324289_41.docm @ 49023 @ 3 @ 1

Step 4: Verification and adjustment of the


weighing
Pos : 282 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Pr üfung und Abgleich Ver wiegung 1 Hi nweis Kontrollgewic hte @ 2 \mod_1340799994787_41.doc m @ 58190 @ @ 1

Observe the execution!


Leave out this step your feeder is not equipped with a weighing system.

Known control weights


For testing the weighing system you need three known test weights (ideally,
10%, 50% and 90% of the weighing range of the load cell).

Evaluation unit
A suitable evaluation unit is required for weighing. The evaluation unit is
connected to the weighing system and processes the weight signal e.g. for a
weight display.

Pos : 284 /Dosi ergeräte/Inbetriebnahme/(CD) AblaufInbetriebnahme - Pr üfung und Abgleich Ver wiegung 2 Trans portsicherung l ösen V1 @ 21\mod_1464159559980_41.doc m @ 239360 @ @ 1

Loosen the transport Loosen the transport catch completely according to the description (see page
catch 24).

Pos : 286 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Pr üfung und Abgleich Ver wiegung 3 Fr eigängig keit @ 1\mod_1337690451657_41.doc m @ 49134 @ @ 1

Free motion Check the free motion of the weighing system:


1. Read the weight loading of the weighing system.
2. Place an additional weight on the weighing system.
3. Take off the additional weight.
4. Read the weight loading of the weighing system.

The test is completed, if the weight values (1) and (4) are identical. If the two
values differ from each other make sure to find and eliminate the cause for the
missing motion. Possible causes:
• The transport catch has not been loosened completely.
• The flexible connection of the inlet/outlet is not sufficient.
• The weighing system is impeded by foreign bodies/contamination.
• The cabling of the assemblies of the device, the adjustment of the overload
protection screw or other executions of the device are inaccurate.

Pos : 288 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

©Operating instructions (DDW-) DDSR xx Commissioning 43


Process of commissioning, continuation

Step 4: Verification and adjustment of the


weighing, continuation
Pos : 289 /Dosi ergeräte/Inbetriebnahme/(CD) AblaufInbetriebnahme - Pr üfung und Abgleich Ver wiegung 4 H ebelfaktor @ 19\mod_1456324635670_41.doc m @ 217464 @ @ 1

Lever factor The lever factor (LF) permits to adjust the weight display of the evaluation unit
to the actual weight loading. The adjustment runs down as follows:
1. Read the actual weight value (W).
2. Place on a known test weight (WT).
The force shall be applied centrically on the weighing system.
3. Read the new weight value (W1).
4. Compute the difference (W1 - W0).

The lever factor has to be corrected, if (W1 - W)  (WT):


5. Read the actual lever factor (LFact)
6. Compute the new lever factor (LFnew).
LFnew = LFact x (WT / (W1 - W0))
7. Enter and memorise the new lever factor.

Check the new lever factor by a new test measurement and adjust it once
again, if required.
Pos : 291 /Dosi ergeräte/Inbetrie bnahme/AblaufInbetriebnahme - Pr üfung und Abgleich Ver wiegung 5 F unktions prüfung @ 1\mod_1337696719320_41.doc m @ 49212 @ @ 1

Functional testing The function of the weighing system is tested by means of three load
measurements over the complete weighing range. The free motion and the
lever factor are checked with each test measurement. The following test
weights are recommended:
1. Test weight ~10% of weighing range
2. Test weight ~50% of weighing range
3. Test weight ~90% of weighing range

Pos : 293 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

44 Commissioning ©Operating instructions (DDW-) DDSR xx


Process of commissioning, continuation

Pos : 294 /Allgemein/Ü berschriften Inbetriebnahme/Übersc hrift 3 - Besti mmung Dosierleis tung @ 14\mod_1433769804466_41.doc m @ 192501 @ 3 @ 1

Step 5: Determination of the feed rate


Pos : 296 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Die Befüllung des Behälters @ 4\mod_1359032000605_41.doc m @ 80385 @ @ 1

Refilling of the hopper Automatic refilling


The automatic refilling requires a feeding controller that permits to control the
product supply and to monitor the hopper filling level. The operating
personnel activates the refilling on the feeding controller which will then
enable the product supply until the hopper filling level has reached the
determined maximum filling level.

Manual filling
The device is refilled manually by the operating personnel. The operator will fill
in the product into the hopper using a suitable aid. Please observe the
following points:
• Take care when filling in the product. A possibly available protective grid
impedes the product flow into the hopper.
• It is not allowed to remove the protective grid to simplify refilling (safety
equipment!).
• Terminate refilling if the hopper is approx. 80 % filled. The monitoring of
the filling level is made optically or via the evaluation unit if the system is
weighed.

Maximum filling level


The indication “80%“ is an indicatory value. The actual fixing of the maximum
filling level has to take into account the corresponding product characteristics
(e.g. bulk density) and has to be adjusted to the operating conditions.
Pos : 298 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

©Operating instructions (DDW-) DDSR xx Commissioning 45


Process of commissioning, continuation

Step 5: Determination of the feed rate, continuation


Pos : 299 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Besti mmungs art Ausliter n @ 14\mod_1433769913461_41.doc m @ 192585 @ @ 1

Determination mode "Gauging" means that the feeding is started for a fixed duration of
“gauging” measurement and the product quantity fed during this time will be weighed.
The feed rate [kg/h] is computed from both values – measuring time and
product quantity. “Gauging” runs down as follows:
1. Choose a suitable collecting receptacle with a known empty weight.
2. Place the collecting receptacle under the outlet.
3. Adjust the speed (setpoint).
4. Start the feeding operation for the duration of measuring (e.g. 2 min.).5.
Stop the feeding operation after expiry of the measuring time.
6. Weigh the collecting receptacle and compute the product weight (weight-
empty weight).
7. Calculate the feed rate [kg/h] (here: product weight x 60/2)
Pos : 300 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Besti mmungs art Ausliter n Kennli nie @ 14\mod_1433770018143_41.doc m @ 192613 @ @ 1

Determination of the characteristic curve


“Gauging” permits to find the feed rate for the corresponding speed. If several
feed rates are required a characteristic curve is needed (speed – feed rate). For
the determination of the characteristic curve we recommend measurements with
the following speeds: “10%”, “40%” and “75%”. If necessary, the characteristic
curve can be improved by integrating further measurement points.

Pos : 301 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 303 /Dosi ergeräte/Inbetriebnahme/AblaufInbetriebnahme - Besti mmungs art " Ermi ttlung der För derleis tung" @ 14\mod_1433770126242_41.doc m @ 192641 @ @ 1

Determination type The feed rate can also be determined in some other way, if the device is
“Checking of max. operated with a feeding controller type Congrav®. A feeding controller type
output” Congrav® offers the function “checking of max. output". This function
computes and automatically memorises the feed rate (= “output”) for different
speed values. The characteristic curve that has thus been computed is
employed by the feeding controller for the control of the feeding operation.

Observe the software description


The “checking of max. output” is described in the software description of the
feeding controller.

Pos : 305 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

46 Commissioning ©Operating instructions (DDW-) DDSR xx


Pos : 306 /Allgemein/Ü berschriften Betrieb/(CD) Ü bersc hrift 2 - Die Produktdosierung @ 18\mod_1455273728394_41.doc m @ 214428 @ 2 @ 1

Product feeding

Pos : 308 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - Vorbereitung @ 1\mod_1337773513123_41.doc m @ 49424 @ @ 1

Preparations The commissioning is terminated by making the system ready for operation. In
order to make the system ready for operation the following preparations are
required:
• Remove auxiliary equipment (collecting receptacle etc.).
• Possibly reconnect separated connections (e.g. outlet).
• Possibly undo conversions (e.g. bypass).
• Discharge the device completely, if a replacement product has been
employed.
• If required, clean the device and the environment.
• Refill the device.

Pos : 310 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - vol umetrische Produktdosi erung @ 14\mod_1433770232347_41.doc m @ 192725 @ @ 1

Volumetric product In case of volumetric product feeding the feeding operation functions with a
feeding constant control of the feed drive (fixed working point). The feed rate is not
sensed and not controlled. I.e. feed rate variations e.g. caused by a variating
filling degree of the feeding organ will not be detected and corrected.
Volumetric product feeding is mostly used, if the downstream processing
equipment does not require an even discharge rate or if it is not affected by
discharge rate fluctuations.

Pos : 312 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - Ablauf ei ner vol umetrisc hen Pr oduktdosier ung @ 14\mod_1433770506774_41.doc m @ 192753 @ @ 1

Volumetric feeding As a rule, volumetric product feeding runs down as follows:


sequence
1. Adjust the working point (e.g. potentiometer = 50%) 2. Start the
feeding operation.
3. If required, adjust the feed rate by a corresponding modification of the
default value (here: potentiometer).
4. Stop the feeding operation, if the required product quantity has been fed out.
Pos : 314 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - Ablauf Warnhinweis Sc hnec ke ohne Produkt @ 14\mod_1433770631456_41.doc m @ 192781 @ @ 1

Operation of the screw without product


» Damage of the device by radial deflections of the screw in the screw
pipe (screws are not turning true).
Attention
Therefore
- Be sure to monitor the filling level in the hopper and refill the hopper
before reaching of the minimum allowed filling level.
- Increased attention during a feeding operation with a high speed.
Pos : 316 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Commissioning 47


Product feeding, continuation

Pos : 317 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - Vorauss etz ung für di e gravi metrische Produktdosierung @ 1\mod_1337852063360_41.docm @ 49584 @ @ 1

Required conditions for For gravimetric product feeding the equipment and the control of the device
gravimetric product have to comply with the following required conditions:
feeding
• The device is a loss-in-weight feeder (“DDW - …”) and is thus equipped
with a weighing system.
• A feeding controller type Congrav® or with comparable functions has to be
employed.

Be sure to observe the documentation of the feeding controller!


A safe feeding operation is only possible if the software parameters of the
feeding controller are permissible and adjusted to the operating conditions. An
expert parameterisation according to the documentation is absolutely required
for a use of the device according to the intended purpose.

Pos : 319 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - gravi metrisc he Produktdosi erung @ 14\mod_1433770749690_41.doc m @ 192809 @ @ 1

Gravimetric product During gravimetric product feeding the feeding operation is started with a
feeding determined discharge rate (product quantity /time unit). During feeding the
feed rate will be measured and controlled via a control circuit. The control
circuit modifies the control of the feed drive and thus tries to correct
variations, e.g. due to a fluctuating filling degree of the feeding organ.

Pos : 321 /Dosi ergeräte/Inbetriebnahme/Pr oduktdosier ung - Ablauf ei ner gravi metrisc hen Produktdosier ung @ 14\mod_1433770828134_41.doc m @ 192837 @ @ 1

Gravimetric feeding As a rule, the feeding controller is used to operate the gravimetric product
sequence feeding and it runs down as follows:
1. Set the desired feed rate as setpoint.
2. Start the feeding operation.
The start command starts the automatical control of the feeding operation by
the feeding controller. The further sequence of control and monitoring of the
feeding operation depends on the functions of the feeding controller and is
described in its documentation.

Pos : 323 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

48 Commissioning ©Operating instructions (DDW-) DDSR xx


Product feeding, continuation

Pos : 324 /Allgemein/Ü berschriften Inbetriebnahme/Übersc hrift 3 - Anpass ung der Dosi erleistung @ 14\mod_1433836897271_41.doc m @ 192874 @ 3 @ 1

Step 6: Adaptation of the feed rate


Pos : 326 /Dosi ergeräte/Inbetriebnahme/(CD) Anpass ung Dosierleis tung - Ei nlei tung (Drehzahl) @ 20\mod_1460528154360_41.doc m @ 223179 @ @ 1

The feed rate is changed by a modification of the operating speed of the drive
motor in the allowed working range. If this measure does not permit to
achieve the desired feed rate, it is required to modify the device. Please find
below the measures for an admissible modification of the device.

Usage not according to the intended purpose


All other modifications to the execution and the electrical assemblies of the
device are not allowed without approval of the manufacturer and are thus not
according to the intended purpose.

Pos : 328 /Dosi ergeräte/Inbetriebnahme/Anpas sung Austr agsleis tung - Anpas sung Dosier organ (Sc hnec ke/Sc hnec kenr ohr) @ 6\mod_1375172279463_41.doc m @ 106508 @ @ 1

Adjustment of feeding The device can be equipped with another combination screw/screw pipe. For
organ this purpose the manufacturer offers different executions/combinations.

Pos : 330 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Commissioning 49


Pos : 331 /Allgemein/Ü berschriften Außer betriebnahme/(CD) Ü bers chrift 1 - Auß erbetriebnahme @ 20\mod_1458815701367_41.doc m @ 221314 @ 1 @ 1

5. Decommissioning

Pos : 333 /Dosi ergeräte/Außer betriebnahme, Stör ung/Aussc halten - Hi nweis @ 2\mod_1338453081214_41.doc m @ 51314 @ @ 1

The following process descriptions do not take into account influences that
occur due to product characteristics or the operation in a production plant. If
additional activities result from these influences they have to be integrated
into the corresponding processes.
Example: Product characteristics
In cases of a product that is not allowed to stay in the device, the device has to be
• discharged completely before shutdown and cleaned thoroughly after
shutdown.
• discharged by means of suitable measures after a fault shutdown, if the
elimination of the cause of the malfunction takes too long.
Pos : 335 /Dosi ergeräte/Außer betriebnahme, Stör ung/(CD) Aussc halten - kurzz eitig Absc hal tung @ 18\mod_1455274011771_41.doc m @ 214456 @ @ 1

Brief disconnection The device is stopped for operational reasons.

Activation: Stop command on the operating unit


How to continue Start command on the operating unit
the operation
Pos : 337 /Dosi ergeräte/Außer betriebnahme, Stör ung/(CD) Aussc halten - Wartung, R epar atur @ 18\mod_1455274128636_41.doc m @ 214484 @ @ 1

Maintenance, Switch off the device for maintenance work.


repair
Activation: 1. Discharge the device.
2. Stop the operation.
3. Disconnect the device. (see (see page 9)
4. Carry out the necessary work.
How to continue Commissioning has to be carried out.
the operation:
Pos : 339 /Dosi ergeräte/Außer betriebnahme, Stör ung /(CD) Aussc halten - Stilllegung @ 18\mod_1455274304159_41.doc m @ 214512 @ @ 1

Decommissioning Disconnect the device for storage or disposal.

Activation: 1. Switch off the device as described in “maintenance,


repair”.
2. Disconnect the device from all supply media,
connections, etc.
3. Disassemble the device.
4. As described in “storage and disposal”
How to continue 1. Assemble the device.
the operation: 2. Mount the device.
3. Commission the device.
Pos : 341 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

50 Decommissioning ©Operating instructions (DDW-) DDSR xx


Pos : 342 /Allgemein/Ü berschriften Störabsc hal tung/(CD) Übersc hrift 1 - Störabsc haltung @ 18\mod_1455274469321_41.doc m @ 214540 @ 1 @ 1

6. Alarm cut-outs

Pos : 344 /Dosi ergeräte/Störabsc haltung/Störabsc haltung - Hinweis @ 2\mod_1338456696888_41.doc m @ 51473 @ @ 1

Fault shutdowns protect the device and the environment


Fault shutdowns occur in operational situations that do not permit to continue
the operation of the device. They are either triggered manually by the
operating personnel (“emergency stop”) or automatically by a monitoring
function or an interlocking chain.

Immediate stop
The fault shutdown of the device may have an effect on
upstream/downstream production processes. Further measures are possibly
required.

Operational readiness requires the elimination of causes


Before renewed commissioning be sure to find and eliminate the reason for
the fault shutdown.

Pos : 346 /Dosi ergeräte/Störabsc haltung/Störabsc haltung - Aufhebung Störabsc haltung @ 2\mod_1338458129434_41.doc m @ 51499 @ @ 1

How to continue the Steps to be taken in order to continue the operation after a fault shutdown:
operation after a fault
1. Find the cause for the malfunction.
shutdown
2. Eliminate the cause for the malfunction.
3. Make sure that the device is ready for operation.
Pos : 348 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Alarm cut-outs 51


Pos : 349 /Allgemein/Ü berschriften Störabsc hal tung/(CD) Übersc hrift 2 - Störungsurs ac hen @ 18\mod_1455274702392_41.doc m @ 214568 @ 2 @ 1

Causes of malfunction

Pos : 351 /Dosi ergeräte/Störabsc haltung/(CD) Störung - Austr agung startet nicht @ 20\mod_1460530227604_41.doc m @ 223235 @ @ 1

Discharge operation Voltage supply is missing


does not start » Connect the voltage supply.
» Replace defective fuses if required.
Execution of connection lines is incorrect
» Eliminate errors in the connections.
» Eliminate interruptions/damage.
» Replace wrong cable types.
Drive components damaged (motor, drive controller etc.)
» Replace damaged components.
Required releases are missing
» Comply with demands of interlocking chains and other operating
requirements.

Pos : 353 /Dosi ergeräte/Störabsc haltung/D okID _451 - (DD W-) RSR xx/Störung - Schl eifger äus che @ 4\mod_1363873221599_41.doc m @ 87295 @ @ 1

Grinding noises Product deposits in the screw pipe


» Clean the screw pipe.
Product jam between screw and pipe wall
» Employ a screw with a different screw diameter.

Pos : 355 /Dosi ergeräte/Störabsc haltung/Störung - Ungleic hnäßig er Füllgrad ( mit R ührwer k) @ 2\mod_1338463971479_41.docm @ 51581 @ @ 1

Uneven filling ratio Screw type not suitable


» Employ other screw type
Product quantity not sufficient
» Refill the hopper.
» Provide agitator function.
» Replace damaged agitator.
» Take measures against product bridges in the hopper.

Pos : 357 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

52 Alarm cut-outs ©Operating instructions (DDW-) DDSR xx


Causes of malfunction, continuation

Pos : 358 /Dosi ergeräte/Störabsc haltung/Störung - Sc hnec ke ver kl emmt @ 2\mod_1338466821830_41.doc m @ 51608 @ @ 1

Screw jammed Foreign bodies in the product zone


» Remove foreign bodies and replace damaged components.
» Eliminate the reason for the penetration of the foreign body.
Screw diameter too big
» Change the combination screw/screw pipe.
Screw type not suitable
» Employ other screw type.
Pos : 359 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 360 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 362 /Dosi ergeräte/Störabsc haltung/D okID _451 - (DD W-) RSR xx/Störung - Aus tragsleis tung z u gering @ 5\mod_1363873263357_41.doc m @ 87322 @ @ 1

Discharge rate Activation of the drive


too low » Increase the speed of the drive.
Wrong screw execution
» Employ a screw with a suitable execution.
Changed product characteristics
» Employ a screw with a suitable execution.
» Adjust operating parameters.

Pos : 364 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/-----> Leerzeil e (For mat: vers tec kter Text) <----- @ 4\mod_1358837888992_0.doc m @ 79738 @ @ 1

Pos : 366 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Alarm cut-outs 53


Pos : 367 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 1 - Wartung @ 18\mod_1455275894764_41.doc m @ 214596 @ 1 @ 1

7. Maintenance

Pos : 369 /Dosi ergeräte/Wartung/(CD) 1. Seite - Inhalt Wartung des Ger ätes @ 18\mod_1455275989273_41.doc m @ 214624 @ @ 1

This chapter describes the activities required for the maintenance of the
device. These activities include the general maintenance and the
disassembly/assembly of components that are subject to wear or require an
increased cleaning effort.

Content of the chapter “maintenance”:

Subject Page
Notes on maintenance 55
Component list 56
Care and examination 58
Cleaning 60
Description for the disassembly of individual components 63
Pos : 371 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

54 Maintenance ©Operating instructions (DDW-) DDSR xx


Pos : 372 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 2 - Hinweise für di e D urc hfühung der Wartung @ 18\mod_1455276158835_41.doc m @ 214652 @ 2 @ 1

Notes on carrying out maintenance

Pos : 374 /Dosi ergeräte/Wartung/WartungHinweis - D as Gerät freis chalten @ 2\mod_1337873069572_41.doc m @ 49955 @ @ 1

Before the disconnection – discharge the device


For carrying out the disassembly work of components in contact with the
product, the feeder has to be discharged by means of a “cleaning operation”
Disconnection before the start of work. The "cleaning operation" permits to discharge the
from the mains feeding device as far as possible by means of the feeding organ.
Disconnect the device
Before the start of any work on the device or on individual components of the
device it has to be disconnected from all supply media and stocks of possibly
present residual energy have to be discharged.
Pos : 376 /Dosi ergeräte/Wartung/WartungHinweis - Warnung Pr oduktr este @ 2\mod_1337871794840_41.doc m @ 49929 @ @ 1

Residual product in/on the device


» During the disassembly of the device/of individual assemblies the
operating personnel might come into contact with the product.
Caution
» Reactions with the cleaning agent might occur.
Therefore
- Be sure to observe the indications of the product data sheet.
- Possibly necessary measures before the start of work
- Safety measures
- Measures for correct disposal
Pos : 380 /Dosi ergeräte/Wartung/WartungHinweis - Warnung sc harfkantige Bauteil e (Sc hnec ke+R ühr wer k) @ 2\mod_1337873327583_41.doc m @ 49981 @ @ 1

Sharp-edged components
» Danger of cuts caused by the agitator and the screws.
Caution Therefore
- Use gloves when working on these components.
Pos : 382 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 55


Pos : 383 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 2 - Auflistung der Bauteile @ 18\mod_1455277319269_41.docm @ 214680 @ 2 @ 1

List of components

Pos : 386 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Wartung - Bauteilzeic hnung V3 (neu) @ 21\mod_1461919218558_0.doc m @ 235770 @ @ 1

Pos : 387 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Wartung - Bauteilliste V3 (neu) Teil 1 @ 21\mod_1462267251102_41.doc m @ 236172 @ @ 1

The markings in the illustration have the following meaning:


No Description
1 Shaft sealing, drive side of the agitator
2 Fastening of shaft sealing
3 Drive motor screw
4 Drive motor agitator
Pos : 389 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

56 Maintenance ©Operating instructions (DDW-) DDSR xx


List of components, continuation

Pos : 391 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Wartung - Bauteilliste V3 (neu) Teil 2 @ 21\mod_1461919341599_41.doc m @ 235797 @ @ 1

No Description
5 Proximity switch
Speed monitoring
6 Spur gear
7 Cover of twin-shaft gearing
8 Twin-shaft gearing
9 Fastening of shaft sealings
10 Shaft sealing, screw
11 Bearing block
12 Sealing
13 Junction boxes
14 Mounting plate
15 Transport catch
16 Weighing system
17 Vibration isolation mounting pads
18 Downstream connection point (connection on site)
19 Flexible connection of outlet
20 Vertical outlet
21 Cover vertical outlet
22 Clamping ring
23 Twin screw
24 Sealing
25 Cleaning hole (here: complete front plate)
26 Sealing
27 Front agitator blade here: execution in two parts
28 Rear agitator blade (optional: welded)
29 Agitator trough
30 Sealing
31 Hopper
32 Sealing
33 Hopper cover
a Vent pipe b Inlet pipe
34 Flexible connection of inlet (product supply)
35 Filter bag (ventilation)
Pos : 397 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 57


Pos : 398 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 2 - Pflege und Kontroll e @ 19\mod_1455277577533_41.doc m @ 214764 @ 2 @ 1

Care and inspection

Pos : 400 /Dosi ergeräte/Wartung/(CD) WartungPflege - Z eitinter valle @ 19\mod_1455277675171_41.doc m @ 214792 @ @ 1

Intervals Marking of the intervals:

W weekly 2W fortnightly
M monthly 3M three-monthly
Y yearly H biannually

Pos : 402 /Dosi ergeräte/Wartung/(CD) WartungPflege - Pflegearbeiten @ 19\mod_1455277984432_41.doc m @ 214820 @ @ 1

Care Care works (T = time interval):


T Activities
W Filter bag/clean ventilation (if available)
2W Clean the device.
- Dust and loose contaminations have to be removed by means of
an industrial vacuum cleaner.
- Solid contaminations have to be removed with a (damp) cloth.
Pos : 403 /Dosi ergeräte/Wartung/D okID_448 - (DD W-) DD SR20/(CD) WartungPfl ege - Kontroll e Schnec kendosierer m. R W @ 21\mod_1463652965730_41.doc m @ 237810 @ @ 1

Examination Examination of the device (T = time interval)


T Component Examination
W Flexible connections Damages
W Fastenings Tight fit
2W Screw Wear, tear
2W Agitator Wear, tear
2W Mobile parts Functionality
2W Sealings Tightness
2W Shaft sealings Tightness
2W Locks Attraction force, tight fit
M Electrical connections Tight fit
Electric cables Damages

Removal of defects
Allowed possibilities for the removal of identified defects:
1. Damaged component is professionally repaired.
2. Damaged component is replaced by a new component.

Pos : 404 /Allgemein/Spezi elleM odul e (Fortse tzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

58 Maintenance ©Operating instructions (DDW-) DDSR xx


Care and inspection, continuation

Pos : 407 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Wartung, Pfleg e - Kontr olle Abdic htung en Antriebs wellen V3 (neu) @ 21\mod_1462172365724_41.doc m @ 235886 @ @ 1

The sealing of the agitator drive shafts


and the twin screw on the product
side is made by means of the radial
packing rings (1) and (3). On the gear
(5), the drive shafts of the twin screw
are sealed by means of shaft sealings
(4) that are inserted in the sealing
plate (2). The radial packing rings are
checked on the basis of deposits in the
different zones:

A1 = on the gear cover


A2 = in the gear cover (6)
A3 = on the mounting plate

Zone Deposit Activities


A1, A2, A3 None None
A1 Product Exchange radial packing ring (1)
A3 Product Exchange radial packing rings (3)
A2 Product Exchange radial packing rings (4) and (3)
A2 Oil Exchange the gear

Pos : 408 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 59


Pos : 409.1 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 2 - Rei nigung des Ger ätes @ 17\mod_1453729968349_41.doc m @ 212252 @ 2 @ 1

Cleaning of the device

Pos : 409.2 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Übersc hrift 3 - Vorgaben für die R einig ung @ 20\mod_1460974600964_41.doc m @ 232933 @ 3 @ 1

Specifications for cleaning


Pos : 409.3 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Rei nigung - Hinweis R einigungs proz ess @ 20\mod_1461241241268_41.doc m @ 233280 @ @ 1

Design of the cleaning process


The dimensioning of the cleaning process by the operator helps to prevent any
danger to persons, the environment and the machine
• because appropriate/allowed cleaning tools are employed.
• the cleaning personnel works with the necessary protective equipment.
• no cross contaminations (feeding products, cleaning agents etc.) will be
produced.

Pos : 409.4 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Rei nigung - Rei nigungsort @ 17\mod_1453732802716_41.docm @ 212360 @ @ 1

Cleaning place The cleaning place must be suitable for


• the safe execution of the cleaning of the device.
• the correct neutralization and disposal of the resulting wastewaters.

Pos : 409.5 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Rei nigung - Spezifi kation R einig ungs mittel @ 17\mod_1453730678386_41.doc m @ 212306 @ @ 1

Specifications for Permitted cleaning agents for the cleaning of components in contact with the
cleaning agents product have to comply with the following specifications:
• Not combustible
• Do not form any explosive or flammable vapours
• No scouring additives
• Temperature of use/working temperature ~ 20°C
• PH value between 4 - 10pH
• Comply with the requirements for the field of application of the device (e.g.
conformity to food processing regulations acc. to “NSF White Book™“)

Pos : 409.6 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Rei nigung - Hinweis R einigungsgüte @ 17\mod_1453734210084_41.docm @ 212414 @ @ 1

Cleaning quality
For a consistent cleaning quality during the cleaning sequence be sure to observe
the “Sinner’s circle“. The cleaning quality is defined as the total sum from the
relation of the parameters temperature, time, chemistry and mechanics.

Pos : 409.7 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Ü berschrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

60 Maintenance ©Operating instructions (DDW-) DDSR xx


Cleaning of the device, continuation

Pos : 409.8 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Übersc hrift 3 - Besc hreibung der R einigungs verfahren @ 20\mod_1460972152188_41.doc m @ 232770 @ 3 @ 1

Description of the cleaning processes


Pos : 409.9 /D osi ergeräte/Wartung/R einig ung ( neue Besc hrei bung)/(CD) Rei nigung - Matrix Rei nigungs verfahren @ 21\mod_1462279849098_41.doc m @ 236199 @ @ 1

Matrix cleaning The following matrix lists possible cleaning procedures as a function of the
procedures application of the device.

Plastics/Global industries ATEX Hygienic, FOOD/Pharma


Dry cleaning X X* X
Controlled wet
X X
cleaning
Wet (COP) X X X
* only with an industrial vacuum cleaner that is approved for the ATEX zone.

Pos : 409.10 /D osierger äte/Wartung/R einigung (neue Besc hreibung)/(CD) Rei nigung - R einig ungs verfahr en 1 (Tr oc ken rei nigen) @ 20\mod_1461243120153_41.doc m @ 233307 @ @ 1

Dry cleaning During dry cleaning, contaminations will be eliminated without use of a liquid
cleaning agent.
• Remove loose contaminations by means of an appropriate auxiliary (e.g.
industrial vacuum cleaner).
• Remove adhesive contaminations by means of a cloth.

Friction between different materials


Avoid static loading!

Pos : 409.11 /D osierger äte/Wartung/R einigung (neue Besc hreibung)/(CD) Rei nigung - R einig ungs verfahr en 2 ( kontrolli erte Nas srei nigung) @ 20\mod_1460973011984_41.doc m @ 232825 @ @ 1

Controlled wet cleaning During a “controlled wet cleaning“ only components in product contact are
wet cleaned. The following specifications apply to a “controlled wet cleaning“:
• The following components have to be cleaned by means of a cloth, if required
the cloth can be moistened with water or a suitable cleaning agent.
- Bearings and electrical components
- Components that are not in contact with the product
- Lacquered components
• During wet cleaning of components in product contact, the components
stated above have to be protected from humidity.
• After cleaning
- the device/the component has to be dried thoroughly,
- remove standing moisture,
- possibly grease degreased components.
Pos : 409.12 /Allgemei n/Spezi elleModule (F orts etz ung, Leerzeil e us w.)/(CD) -----> Abschnittfor tsetzung Ü bersc hrift 3 (Ü2, Ü3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 61


Cleaning of the device, continuation

Description of the cleaning processes, continuation


Pos : 409.13 /D osierger äte/Wartung/R einigung (neue Besc hreibung)/(CD) Rei nigung - R einig ungs verfahr en 3 (N assr einigung COP) @ 20\mod_1460973980237_41.doc m @ 232906 @ @ 1

Wet cleaning (COP) All components to be cleaned are disassembled and cleaned at the provided
cleaning place (COP = clean out of place). The following example shows the
process of cleaning that meets very high standards:
• Precleaning with water
• Cleaning with a lye solution
• Periodic cleaning with water
• Neutralisation (possibly disinfection)/acid cleaning
• Final cleaning with low-germ (distilled) water
• The correct neutralization and disposal of the resulting wastewaters.

Pos : 410 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

62 Maintenance ©Operating instructions (DDW-) DDSR xx


Pos : 411 /Allgemein/Ü berschriften Wartung/(CD) Ü bersc hrift 2 - Ei n-/Aus bau von einz el nen Bauteilen @ 19\mod_1455278358374_41.doc m @ 214876 @ 2 @ 1

Assembly/disassembly of individual components

Pos : 413 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Aus bau D oppel-Sc hnec ke @ 2\mod_1338283637537_41.doc m @ 50245 @ 3 @ 1

Disassembly twin screw


Pos : 414 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Aus baubeschr eibung - Aus bau D oppel-Sc hnec ke @ 22\mod_1466425999510_41.doc m @ 241634 @ @ 1

Disassembly of the twin screw:


1. Disconnect the device (figure 1)
2. Loosen the connection to the outlet.
3. Loosen the fastening at the trough (A).
4. Remove the screw pipe with the vertical
outlet (figure 2).
5. Carefully pull off the sealing (figure 3).
6. Loosen both screws by means of a brief
clockwise rotation and pull them out (figure
4).

What to do in case of stuck screws


• In case of twin screws without an additional
front bearing a M6 screw is screwed into the
thread at the head of the screw (B) and thus
the screw is loosened.
• Twin screws with an additional front bearing
are equipped with a wrench flat (C) at the
front end of the screw shaft for the use of a
wrench.

Pos : 416 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 63


Assembly/disassembly of individual components, continuation

Pos : 417 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Verti kaler Auslauf mi t Schnec kenl agerung @ 5\mod_1371036282896_41.doc m @ 96194 @ 3 @ 1

Vertical outlet with screw bearing


Pos : 418 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Wartung - Verti kaler Auslauf mit Schnec kenl agerung @ 22\mod_1466424342672_41.doc m @ 241607 @ @ 1

No Description:
1 Sealing of screw pipe
2 Screw pipe
3 Vertical outlet
4 Labyrinth sealing
5 Groove ball bearing
6 Bearing housing
7 Cover
8 Sealing of vertical outlet:

Before the assembly of the vertical outlet the shaft bearing and the sealings
have to be cleaned and checked for damage. Replace damaged components.

Pos : 419 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Ei nbau D oppel-Sc hnec ke @ 2\mod_1338294687364_41.doc m @ 50518 @ 3 @ 1

Assembly twin screw


Pos : 420 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/War tung - Ei nbau D oppel-Sc hnec ke V1 @ 5\mod_1369217210095_41.doc m @ 94032 @ @ 1

1. Clean and slightly grease the shaft journal and the location bore.
2. Both screws have to be aligned. Be sure to observe the marking of the
screws (L = left; R = right).
3. Slide both screws at the same time on the shaft journals.
4. Turn both screws briefly in anti-clockwise direction.
5. Clean the connection surfaces and the sealing of the screw pipe.
6. Slide on the sealing.
7. Slide on the screw pipe and the vertical outlet and fasten it.
8. Connect the flexible connection to the outlet.

Concerning (7.) Vertical outlet with screw bearing


If problems should arise with the mounting of the vertical outlet, the following
steps permit to simplify the assembly:
1. Disassemble the shaft bearing at the vertical outlet.
2. Slide on the screw pipe and the vertical outlet and fasten it.
3. Assemble the shaft bearing at the vertical outlet.

Pos : 422 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

64 Maintenance ©Operating instructions (DDW-) DDSR xx


Assembly/disassembly of individual components, continuation

Pos : 423 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Aus bau R ührwer k @ 2\mod_1338302019837_41.doc m @ 50705 @ 3 @ 1

Disassembly of the agitator


Pos : 424 /Dosi ergeräte/Wartung/(CD) Ausbaubesc hrei bung - Aus bau Rühr wer k ohne R ei nigungs öffnung ( 1-teilig) @ 21\mod_1462280717490_41.doc m @ 236253 @ @ 1

Agitator trough without Disassembly in case of an agitator trough without cleaning hole:
cleaning hole Pos : 425 /Dosi ergeräte/Wartung/(CD) Ausba ubesc hrei bung - Aus bau Rühr wer k (1-teilig) @ 22\mod_1466426493463_41.doc m @ 241661 @ @ 1

1. Loosen the connections of the hopper cover.


2. Disassemble the hopper.
3. Loosen the agitator (clockwise rotation, figure 2).
4. Pull the agitator forward (figure 3).
5. Remove the agitator from the screw trough (figure 4)

Pos : 426 /Dosi ergeräte/Wartung/(CD) Ausbaubesc hrei bung - Aus bau Rühr wer k mi t R einigungsöffnung (2teilig) @ 21\mod_1462280925513_41.doc m @ 236280 @ @ 1

Agitator trough with Disassembly in case of an agitator trough with cleaning hole:
cleaning hole
Pos : 427 /Dosi ergeräte/Wartung/(CD) Ausbaubesc hrei bung - Aus bau Rühr wer k (2-teilig) @ 21\mod_1462281118549_41.doc m @ 236307 @ @ 1

1. Remove the cover (1) of the cleaning hole (figure A).


2. Remove the locking screw (2) of the agitator by means of a hexagon box
spanner. Hold the front piece with your free hand.
3. Take the agitator out of the agitator trough and place it down in an
appropriate place (figure B; here: execution in two parts).
Pos : 429 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 65


Assembly/disassembly of individual components, continuation

Pos : 430 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Ei nbau des Rühr werks @ 2\mod_1338363676619_41.doc m @ 50851 @ 3 @ 1

Assembly of the agitator


Pos : 431 /Dosi ergeräte/Wartung/(CD) Einbaubeschr eibung - Ei nbau R ühr wer k ohne Rei nigungsöffnung (1-teilig) @ 21\mod_1462282234043_41.doc m @ 236334 @ @ 1

Agitator trough without Assembly in case of an agitator trough without cleaning hole:
cleaning hole Pos : 432 /Dosi ergeräte/Wartung/Einbaubesc hreibung - Ei nbau R ühr wer k (1- teilig) @ 5\mod_1371039691313_41.doc m @ 96326 @ @ 1

1. The threaded bolt and the thread of the agitator have to be cleaned
thoroughly and greased slightly.
2. Cautiously insert the agitator into the trough.
3. Screw tight the agitator by means of a rotation to the left.
4. Mount the hopper.
Pos : 433 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 434 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/- -----> Leerzeil e (For mat: Text) <----- @ 0\mod_1317890599730_41.doc m @ 12133 @ @ 1

Pos : 435 /Dosi ergeräte/Wartung/(CD) Einbaubeschr eibung - Ei nbau R ühr wer k (2teilig) Kopfzeil e @ 21\mod_1462282453845_41.doc m @ 236361 @ @ 1

Agitator trough with Assembly in case of an agitator trough with cleaning hole:
cleaning hole Pos : 436 /Dosi ergeräte/Wartung/(CD) Einbaubeschr eibung - Ei nbau R ühr wer k (2-teilig) @ 21\mod_1462282608328_41.doc m @ 236388 @ @ 1

1. Clean all parts of the agitator thoroughly.


2. Slightly grease the agitator shaft.
3. Slide the agitator on the agitator shaft.
4. Secure the agitator with the screw.
5. Place on the cover of the cleaning hole and tighten all screwings.
Pos : 437 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

66 Maintenance ©Operating instructions (DDW-) DDSR xx


Assembly/disassembly of individual components, continuation

Pos : 438 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - Austausc h Wellendic htring e @ 4\mod_1360240598086_41.doc m @ 81341 @ 3 @ 1

Exchange of shaft sealing rings


Pos : 439 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/Aus baubeschr eibung - Austausc h Well endic htringe DDSR 40 am D W-Getriebe @ 5\mod_1371040834316_41.doc m @ 96353 @ @ 1

Radial packing rings on


the twin-shaft gearing
DDSR40

1. Disassemble the drive motor of the twin screw.


2. Disassemble the twin screw.
3. Disassemble the twin-shaft gearing.
4. Loosen the screws (1) of the sealing plate (2).
5. Remove the sealing plate (2) with the radial packing rings.
6. Remove the shaft sealings (3) from their seat in the sealing plate.
7. Clean all components.
8. Slightly grease the drive shafts.
9. Insert new radial packing rings.
10. Slide the sealing plate on the drive shafts.
11. Fasten the sealing plate.
12. Mount the twin-shaft gearing.
13. Mount the twin screw.
14. Assemble the drive motor of the twin screw.
15. Make the device ready for operation.

Pos : 440 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 67


Assembly/disassembly of individual components, continuation

Exchange of shaft sealing rings, continuation


Pos : 442 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Aus baubeschr eibung - Austausch Well endic htringe am Sc hnec kentr og V3 (neu) T eil1 @ 21 \mod_1463728574563_41.doc m @ 238137 @ @ 1

Radial packing rings on


the screw trough

1. Disassemble the twin screw.


2. Disassemble the agitator.
3. Loosen the fastenings (1a) and (1b)
and remove the bearing block.
4. Remove the sealing (2) from the
bearing block.
5. Disassemble the shaft sealing of the
agitator (3).

6. Disassemble the fastening (4) of the cover of the twin-shaft gearing.


7. Take off the cover (5).
8. Loosen the fastening (6) of the twin-shaft gearing.
9. Remove the twin-shaft gearing (7).
10. Disassemble the safety plate (8).
11. Loosen the shaft sealings of the twin screw (9) from the bearing seat.
Pos : 443 /Dosi ergeräte/Wartung/(CD) Ausbaubesc hrei bung - Einbaurichtung Well endic htung ( Prelon) @ 21\mod_1463727096977_41.doc m @ 238083 @ @ 1

Mind the mounting direction of the shaft sealing!


The shaft sealing (2) has a prescribed
mounting direction. The example of an
agitator shaft (3) is shown in the
illustration (3). The shaft sealing (2) is
inserted in the bearing seat with the O-
ring (2.1) first. Finally the bearing has to
be closed with the bearing cover (1).

Pos : 444 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 3 (Ü2, Ü 3) <----- @ 18\mod_1455260519360_41.doc m @ 213728 @ @ 1

68 Maintenance ©Operating instructions (DDW-) DDSR xx


Assembly/disassembly of individual components, continuation

Exchange of shaft sealing rings, continuation


Pos : 446 /Dosi ergeräte/Wartung/D okID_453 - (DD W-) DD SR/(CD) Aus baubeschr eibung - Austausch Well endic htringe am Sc hnec kentr og V3 (neu) T eil2 @ 21 \mod_1463728632727_41.doc m @ 238164 @ @ 1

Assembly 12. Clean all components and bearing seats.


13. Slightly grease the drive shaft(s).
14. Insert new radial packing rings.
15. Assemble the bearing block.
16. Mont the bearing block to the agitator trough.
17. Mount the twin screw.
18. Mount the agitator.
19. Make the device ready for operation.

Pos : 448 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/(CD) -----> Absc hni ttforts etz ung Übersc hrift 2 <----- @ 17\mod_1455202505694_41.doc m @ 212909 @ @ 1

©Operating instructions (DDW-) DDSR xx Maintenance 69


Assembly/disassembly of individual components, continuation

Pos : 449 /Allgemein/Ü berschriften Wartung/Ü bers chrift 3 - J usti erung Drehzahl über wac hung @ 5\mod_1363875276066_41.doc m @ 87698 @ 3 @ 1

Adjustment of speed monitoring


Pos : 450 /Dosi ergeräte/Wartung/D okID_451 - (DD W-) R SR xx/Justier ung - Jus tier ung Dr ehz ahlüber wac hung @ 5\mod_1363875253882_41.doc m @ 87671 @ @ 1

Depending on how the proximity switch has been mounted, the scanning
distance is visible or not visible. Therefore, the adjustment is carried out with
or without sight.
1. Pull the plug of the proximity switch.
2. Undo the locknut of the proximity switch.
3. Adjustment without sight
a. Slightly rotate the proximity switch against the toothed wheel.
b. 1-2 rotations counterclockwise.
If available: Observe the position of the angular plug.
Adjustment with sight
a. Set the distance to 1 mm.
4. Lock the proximity switch by means of the counternut.

Pos : 452 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

70 Maintenance ©Operating instructions (DDW-) DDSR xx


Pos : 453 /Allgemein/Ü berschriften Einl ager ung, Ents orgung/(CD) Ü berschrift 1 - Ei nlag erung und Entsorgung @ 19\mod_1455279444895_41.doc m @ 214932 @ 1 @ 1

8. Storage and disposal

Pos : 455 /Dosi ergeräte/Ei nlager ung, Ents orgung/(CD) 1. Seite - Inhal t Ei nlag erung und Entsorgung @ 19\mod_1455279511726_41.doc m @ 214960 @ @ 1

This chapter describes the conditions for the storage and the disposal of the
device or of its individual components.

Content of the chapter “storage and disposal”:

Subject Page
Storage of the device, of individual assemblies 72
Disposal of the device, of individual assemblies 73
Pos : 457 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Storage and disposal 71


Pos : 458 /Allgemein/Ü berschriften Einl ager ung, Ents orgung/(CD) Ü berschrift 2 - Ei nlag erung des Gerätes, ei nz elner Bauteile @ 19\mod_1455279637478_41.doc m @ 214988 @ 2 @ 1

Storage of the device, of individual assemblies

Pos : 460 /Dosi ergeräte/Ei nlager ung, Ents orgung/Ei nlager ung - Ausführ ung Gerät @ 2\mod_1338370523194_41.doc m @ 51120 @ @ 1

Execution of the device Execution of the device for storage:


• The device is completely discharged and thoroughly cleaned.
• The protective coating of the painted parts is okay or has been
renewed/touched up.
• The following components have to be disassembled:
- In general all sleeves and compensators have to be disassembled and
have to be stored together with the device under appropriate storage
conditions.
- Components with special storage conditions

Pos : 462 /Dosi ergeräte/Ei nlager ung, Ents orgung/(CD) Ei nlager ung - Lagerbedingungen @ 19\mod_1455279770842_41.doc m @ 215016 @ @ 1

Storage conditions Storage conditions for the storage of the device/individual assemblies:

Temperature: +10°C to +40°C


Humidity: 40% to 70% no standing moisture
Medium: Air (well ventilated and free from ozone, chemicals,
solvents)
Storage room: Weather-proof, enclosed building
Clean, possibly free from dust
Packaging: Suitable packaging box, provide spacers under the
cover (air circulation)
Pos : 464 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

72 Storage and disposal ©Operating instructions (DDW-) DDSR xx


Pos : 465 /Allgemein/Ü berschriften Einl ager ung, Ents orgung/(CD) Ü berschrift 2 - Entsorgung des Gerätes , einz elner Bauteile @ 2\mod_1338369512608_41.doc m @ 51014 @ 2 @ 1

Disposal of the device, of individual components

Pos : 467 /Dosi ergeräte/Wartung/WartungHinweis - Warnung Pr oduktr este @ 2\mod_1337871794840_41.doc m @ 49929 @ @ 1

Residual product in/on the device


» During the disassembly of the device/of individual assemblies the
operating personnel might come into contact with the product.
Caution
» Reactions with the cleaning agent might occur.
Therefore
- Be sure to observe the indications of the product data sheet.
- Possibly necessary measures before the start of work
- Safety measures
- Measures for correct disposal
Pos : 469 /Dosi ergeräte/Wartung/WartungHinweis - Warnung sc harfkantige Bauteil e (Sc hnec ke+R ühr wer k) @ 2\mod_1337873327583_41.doc m @ 49981 @ @ 1

Sharp-edged components
» Danger of cuts caused by the agitator and the screws.
Caution Therefore
- Use gloves when working on these components.
Pos : 471 /Dosi ergeräte/Ei nlager ung, Ents orgung/Ents orgung - Vor der Ents orgung @ 2\mod_1338386778340_41.doc m @ 51173 @ @ 1

Before the disposal Before the disposal the following procedures have to be carried out:
1. Disconnect the device from all supply media.
2. Disassemble all connections from the device.
3. The device has to be disassembled completely.
4. The component groups have to be cleaned from product rests and
lubricant residues.

Pos : 473 /Dosi ergeräte/Ei nlager ung, Ents orgung/(CD) Ents orgung - Ents orgung Bauteil e @ 19\mod_1455279973833_41.doc m @ 215044 @ @ 1

Disposal The individual components of the device have to be disposed separately:


Component Disposal
Drive, gear See manufacturer’s indications
Electrical cables Cable scrap
Sleeves, compensator etc. PU, EPDM, silicone or similar
Vessel, pipes, sheets Metal scrap
Insulations According to material specifications
Boards Special waste
Accumulators, batteries Special waste
Plastic Disposal of plastics
Pos : 474 /Allgemein/Spezi elleM odul e (Fortsetzung, Leerz eile us w.)/--------------------- Seitenumbr uch -------------------------- @ 0\mod_1317195024148_0.doc m @ 10973 @ @ 1

©Operating instructions (DDW-) DDSR xx Storage and disposal 73


Pos : 475 /Allgemein/Index/Ü bers chrift 1 - Index @ 8\mod_1384844103046_41.doc m @ 118949 @ @ 1

Index Pos : 476 /Allgemein/Index/Index - Index- Eintr äge ( 2s paltig) @ 8\mod_1384844278307_0.doc m @ 118975 @ @ 1

A O
Agitator 6, 10, 11, 15, 16, 17, 19, Operating personnel, protection 8
22, 23, 37, 52, 55, 56, 57, 58, 59, Operating personnel, qualification8
65, 66, 68, 69, 73 Operation, allowed 18
Agitator, trough 6, 16, 17, 19, 22, Operation, no start 52
57, 65, 66, 69 P
Assembly, execution 28 Product outlet opening 23
D Product, appropriate 6
Disconnection, warning symbol 8, Product, characteristics 6, 18, 41,
11 45, 50, 53
Drive 6, 11, 15, 16, 22, 36, 42, 49, R
56, 67 Residual energy storage 9
Drive shaft 22, 23, 59, 67, 69 S
Drive shaft, agitator 66, 68 Safety grid 18
Drive shaft, screw 63 Safety switch 13
E Shaft sealing 23, 56, 57, 58, 59, 67,
Earthing, correct 9 68
Environment, data 6, 26 Speed monitoring 16, 21, 26, 36,
G 57, 70
Gear 22, 57, 59, 73 U
I Use in accordance with the
Intended purpose 8, 48, 49 intended purpose 6
L V
Load cell, free movement 43, 44 Vertical outlet 16, 22, 57, 63, 64
Load cell, lever factor 44 W
M Wiring plan, CBplus 36
Mounting, tools 28
=== Ende der Liste für T extmar ke Inhalt ===

74 Storage and disposal ©Operating instructions (DDW-) DDSR xx

You might also like