You are on page 1of 3

NUMBER E06-X04

REV. NO. 2
ENGINEERING STANDARD DATE JUN 2001
PAGE 1 OF 3

Motors, DC - Data Sheet

This document is issued by Engineering Standards Section, SABIC R&D Complex, PO Box 42503, Riyadh 11551, Kingdom of Saudi Arabia.
The information contained in this document is the confidential property of SABIC. It can not be disclosed, copied or used for any purpose
without prior approval from SABIC. If you are not authorized to possess this document, please destroy it immediately.
NUMBER E06-X04
REV. NO. 2
Motors, DC - Data Sheet
DATE JUN 2001
ENGINEERING STANDARD PAGE 2 OF 3

1. Scope
These data sheets shall be used in conjunction with SES E06-S04.

SABIC affiliate : _________________________________________ Project no : __________________________________


Plant location : ___________________________ Inquiry no. : __________________________ Date : _________________
Service area : ________________________________________________________________ Quantity: _______________
Manufacturer : ___________________________ Type : _______________________________ Size : _________________
GENERAL
Location Site Condition
Indoor unclassified Relative humidity : Max % _______ Min % _____
† Pressurized bldg. † HVAC bldg. Altitude above sea level ________
Corrosive atmosphere : † Yes † No
Enclosure Temperature : Max °C ______ Min °C_________
† NEMA 1 † NEMA 1 gasketed
RATINGS AND APPLICATION DATA
Motor type Mounting
† Straight shunt wound † Series wound † Horizontal † Vertical
† Stabilized shunt wound † Permanent magnet † Footless † Type C face
† Compound wound † Type D flange † Other________
Power source † Vertical jacking bolts required
† Battery † MG Set Thrust load _________________
† Variable speed drive † Type_____________________
† Rectified power supply † Supply Code_______________ † Std sliding base Other ____________
Supply Voltage Terminal boxes
Armature Volts
† 500 † 700 † Weather proof † Explosion proof location
† 600 † 750
Field Volts † F1 † F2 † Others________
† 150 † 300
† 240 † Others__________________
OPTIONAL FEATURES
Output power kW Accessories

† Nameplate power ______________kW


† Continuous overload ______________kW † Space heaters sheath temp.______ °C V_____
† 2 Hour overload ______________kW † Redundant brushes
Rated torque ______________ † Auxiliary cooling fans
Direction of rotation Internal Air___________kW_________V
(Viewed from non-drive end) External Air____kW_________V
† CCW † CW
Speed † RTD’s field windings
Base ____________rpm † RTD’s air temperature in and out of motor
Top ____________rpm † RTD’s bearing temperature
Enclosure type
† Vibration monitoring on bearings
† TEAOP † TEDC-A/W † TEAOP † Diff. pressure alarm on air filters
† Explosion proof † Low cooling water flow alarm
† Totally enclosed pipe ventilated
Plant cooling water characteristics:
______________________________________________
______________________________________________
______________________________________________
NUMBER E06-X04
REV. NO. 2
Motors, DC - Data Sheet
DATE JUN 2001
ENGINEERING STANDARD
PAGE 3 OF 3

Data Sheet

Insulation
Test and Inspection
Armature class______ Field class______
Design max temp rise ____________________ °C † Inspection at factory by SABIC
† Routine production tests
Frame † Special tests as listed below
NEMA frame number ______________ † Tests to be witnessed by SABIC
Above NEMA vendor frame ______________ † Tests to be observed by SABIC

MANUFACTURER’S DATA OTHER REQUIREMENTS


Manufacturer _____________________________________
S/O No.__________________________________________ __________________________________________
Serial No. ________________________________________
Outline drawing ___________________________________ __________________________________________

Current ratings __________________________________________


Armature ________________________________amps avg
Starting ____________________________________amps __________________________________________
Field
__________________________________________
At Base speed___________ rpm __________amps
At 150% base speed______ rpm __________amps __________________________________________
At highest rated speed ____rpm __________amps
From factor________________________________ __________________________________________
or RMS current ________________________amps
__________________________________________
Inductance and Resistance
Armature __________________________________________
Res ___________________________Ω at 25 °C
Induct._____________________________ mH, sat. __________________________________________

__________________________________________
Shunt field
Res ____________________________Ω at 25 °C __________________________________________
Induct. ___________________________mH, unsat.
__________________________________________
Armature inertia _________________________1b-ft2
Bearing type _______________________________ __________________________________________
External thrust ___________________________1bs
Insulation class _____________________________ __________________________________________
Motor catalog No.____________________________
Space heater: V________W ________ __________________________________________
Remarks: