1.1 Overview
The NPT System Specifications describes the technical specifications of the platforms, cards, modules, and
transceivers included in each platform.
WARNING: failure to follow directions could result in bodily harm or loss of life.
LASER WARNING: how to avoid personal injury. All personnel involved in equipment
installation, operation, and maintenance must be aware that laser radiation is invisible.
Therefore, although protective devices generally prevent direct exposure to the beam,
personnel must strictly observe the applicable safety precautions and, in particular, must
avoid staring into optical connectors, either directly or using optical instruments.
ESD: information on how to avoid discharge of static electricity and subsequent damage to
the unit.
TIP: helpful information and handy hints that can make your task easier.
Fax: +972-3-9268060
Email: techdoc.feedback@ecitele.com
3.3 Redundancy
DC power system Dual power feeding 1+1 redundancy
3.4 Synchronization
Multiple types of timing references available from packet multiple timing sources:
E1/T1 interfaces
From any GbE port that supports synchronous Ethernet
1588v2 PTP Ordinary Clock
Synchronization Status Message (SSM) support is provided (over ESMC)
3.8 Management
Applicable specifications G.784, G.774, M.3010, M.3100
LightSoft (ECI Telecom Network on SUN workstation(s)
Manager) server and client for
managing all ECI Telecom
equipment
EMS-APT (element manager) on PC or SUN workstation(s)
LCT-APT (local craft terminal) on PC
3.9.1 NPT-1010
GbE Interface type 1000Base-SX, LX, EX, ZX, BD, colored
100Base-FX (SM, MM)
10/100/1000Base-T
GPON ONU interface (with GTGBE_L3BD)
Max. number of GbE ports 8
3.9.2 TMSE1_8
Interfaces 8 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES services 8
Encapsulation Protocol CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR 19.44 MHz
RTP timestamp 25 MHz
Adaptive timing domain 8
Differential timing domain 8
Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000us@125 µsec
Jitter buffer Max delay var 1000-64000 @1000 µsec
Jitter buffer Min latency 500-32000 @500 µsec
Standards compliance IEFT RFC4553, RFC5086
MEF8, MEF3
ITU-T Y.1413, G.703
Transmitter type GbE/FC1/ GbE/FC1/ GbE/FC1/ GbE/FC1/ FX, short-reach FX, short-reach
FICON(2) FICON(2) FICON(2) laser, 1310 laser, 1310 nm,
FICON(2) long-reach laser, very long-reach very long-reach multimode single mode
short-reach 1310 nm, single laser, 1550 nm, laser, 1550 nm,
laser, 850 nm, mode single mode single mode
multimode
Typical Rx LOS -24 -29 -25 -25 < -33 < -28
level (dBm)
Connector LC LC LC LC LC LC
Transmitter type Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional
1310 nm 1490 nm 1310 nm e 1490 nm 1490 nm SFP, 1590 nm
Average receiver < -21 < -21 < -23 < -23 -26 -26
sensitivity (dBm)
Typical Rx LOS level < -22 < -22 < -24 < -24 < -26 < -26
(dBm)
Connector LC LC LC LC LC LC
Fiber lengths 10 km 10 km 40 km 40 km 80 km 80 km
(9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF)
CWDM DWDM
TRANSMITTER
RECEIVER
1
New optical SFP transceivers for existing SIO16 basecard.
2
Application code is in reference to ITU-T Recommendation G.691.
CWDM DWDM
Min. sensitivity (BER of 1*10-12) EOL (dBm) -21.5 -28 -28 -28
(-23 GbE) (-32 GbE)
Connector RJ-45
3.11 Dimensions (H x W x D)
NPT-1010 shelf 44.4 mm x 223.5 mm x 224 mm
Racks 2200/2600 mm x 600 mm x 300 mm
3.12 Weight
NPT-1010 2.5 kg
3.13 Power
Applicable specification ETSI 300 132-2
CAUTION: The maximum allowed input DC voltage when using PoE is - 58 VDC.
3.15.1 Operation
Applicable specification ETSI-300-019-2-3 Class 3.3
Temperature range -25°C to +70°C
Relative humidity 5% to 95%
3.16 EMC
Applicable specifications EN 300 386/2000
Applicable directive EMC directive 89/336 EEC
3.17 Safety
Applicable specifications EN 60950/2000
Applicable CE directive LVD directive 73/23/EEC
3.19 Reliability
This section describes the reliability of the NPT-1010 platform with respect to product life and availability.
3.19.1 Life
Expected lifetime of the NPT-1010 15 years
3.19.2 Availability
Availability of service for an end-to-end service better than 99.999%
trail passing through a protected packet network
4.4 Redundancy
DC power system INF-B1U/INF-E2U 1+1 redundancy
4.5 Synchronization
There are multiple types of timing references available from multiple timing sources:
E1/T1 interfaces
STM-1 of CES cards
From any GbE/10 GbE port that supports synchronous Ethernet
An external input/output of 2.048 MHz or 2.048 Mbps
G.813 internal clock, free-run, accuracy of ±4.6 ppm
1588v PTP Ordinary Clock
Synchronization Status Marker (SSM) and Ethernet Synchronization Message Channel (ESMC) are
provided
3
Depends on the network conditions and PTP protocol configuration, and limited by 2000 pps budget.
4.11 Management
Applicable specifications G.784, G.774, M.3010, M.3100
LightSoft (ECI Telecom Network on SUN workstation(s)
Manager) server and client for
managing all ECI Telecom
equipment
EMS-APT (element manager) on PC or SUN workstation(s)
LCT-APT (local craft terminal) on PC
SFP transceiver name OTR1_S3 OTR1_L3 OTR1_L5 OTR1_X3 OTR1_X5 OTR1_VL5 OTR1_VLC5
Operating wavelength (nm) 1261-1360 1263-1360 1480-1580 1270-1360 1500-1520 1500-1520 1544.5-1557.5
TRANSMITTER
RECEIVER 5
4
Application code is in reference to ITU-T Recommendation G.691.
5
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
SFP transceiver name OTR1_S3 OTR1_L3 OTR1_L5 OTR1_X3 OTR1_X5 OTR1_VL5 OTR1_VLC5
Min. sensitivity (BER of -28 -34 -34 -37 -35 -42 -42
1 * 10-12) EOL (dBm)
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR1-S3BD can work only vis-a-vis OTR1-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
TRANSMITTER
RECEIVER 9
6
Application code is in reference to ITU-T Recommendation G.691.
7
BD 3: STM-1 single-fiber bidirectional SFP module with a 1310 nm TX wavelength.
8
BD 5: STM-1 single-fiber bidirectional SFP module with a 1550 nm TX wavelength.
9
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
Min. sensitivity (BER of 1 * 10-12) -32 -32 -32 -32 -34 -34
EOL (dBm)
TRANSMITTER
Min. sensitivity (BER of 1 * 10-12) EOL (dBm) -28 -28 -28 -34 -29
10
Application code is in reference to ITU-T Recommendation G.691.
11
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR4-S3BD can work only vis-a-vis OTR4-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
NOTE: OTR16 bidirectional SFPs (in the following table) are multirate transceivers that
support both STM-4 and STM-16.
TRANSMITTER
12
Application code is in reference to ITU-T Recommendation G.691.
13
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
4.13.3 DHGE_4E
Interface connector type 4 x RJ45
Supported ports 4 x 10/100/1000Base-Tx with PoE+ support
PoE PSE pin-out IEEE 802.3af, Alternative A
Supported PD type IEEE 802.3at type 1, type 2
Maximum PoE power per port 30 W
Maximum PoE power per card 62 W
Number of Sync-E ports 4 (all ports)
4.13.4 DHGE_8
Interface connector type 4 x SFP
Supported port types 1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
10/100/1000Base-T
Maximum number of 1000Base-X ports 8 (with CSFP)
4 (with SFP)
Maximum number of 100Base-FX ports 8 (with CSFP)
4 (with SFP)
Maximum number of 10/100/1000Base-T ports 4 (with copper SFP – ETGBE)
Number of Sync-E ports 8 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
4.13.5 DMCES1_4
Interfaces 4 x channelized STM-1(SFP)
1 x channelized STM-4 (SFP)
1 x GbE SFP
CES service Unstructured E1 (SAToP)
Channelized E1 (CESoPSN)
Number of CES services 252
Encapsulation Protocol in standalone mode CESoETH, CESoIP/UDP
Encapsulation Protocol in integration mode CESoETH and CESoMPLS
CES clock recovery mechanism Adaptive Clock Recovery (ACR)
Differential Clock Recovery (DCR)
Reference clock frequency for DCR RTP 19.44 MHz
timestamp 25 MHz
Number of ACR domains 32
Number of DCR domain 252
E1 Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000us@125us
Jitter buffer Max delay var 1000-64000 @1000 µsec
4.13.6 MSE1_16
Interfaces 16 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
4.13.7 MSC_2_8
Interfaces 2 x Channelized STM-1/OC-3 (SFP)
8 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES service 126 x E1 (over 2 x STM1) + 8 x E1
OR
168 x DS1 (over 2 x OC-3) + 8 x DS1
Encapsulation Protocol CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Transmitter type GbE/FC1/ GbE/FC1/ GbE/FC1/ GbE/FC1/ FX, short-reach FX, short-reach
FICON(2) FICON(2) FICON(2) laser, 1310 laser, 1310 nm,
FICON(2) long-reach laser, very long-reach very long-reach multimode single mode
short-reach 1310 nm, single laser, 1550 nm, laser, 1550 nm,
laser, 850 nm, mode single mode single mode
multimode
Typical Rx LOS -24 -29 -25 -25 < -33 < -28
level (dBm)
Connector LC LC LC LC LC LC
Transmitter type Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional
1310 nm 1490 nm 1310 nm e 1490 nm 1490 nm SFP, 1590 nm
Average receiver < -21 < -21 < -23 < -23 -26 -26
sensitivity (dBm)
Typical Rx LOS level < -22 < -22 < -24 < -24 < -26 < -26
(dBm)
Connector LC LC LC LC LC LC
Fiber lengths 10 km 10 km 40 km 40 km 80 km 80 km
(9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF)
CWDM DWDM
TRANSMITTER
14
New optical SFP transceivers for existing SIO16 basecard.
15
Application code is in reference to ITU-T Recommendation G.691.
CWDM DWDM
RECEIVER
Min. sensitivity (BER of 1*10-12) EOL (dBm) -21.5 -28 -28 -28
(-23 GbE) (-32 GbE)
TRANSMITTER
Spacing (GHz) NA NA NA NA NA NA -
16
Application code is in reference to ITU-T Recommendation G.691.
RECEIVER
Min. Attenuation 5 5 11 0 0 0 -
(dB)
Min. sensitivity (BER -14.1 -14.1 -24 -11 -12.6 -6.5 -22
of 1*10-12)
EOL (dBm)
OPTICAL PATH
BETWEEN S & R
Source type CWDM DFB CWDM DFB CWDM DFB CWDM DFB
17
Application code is in reference to ITU-T Recommendation G.691.
APPLICATION CODE 18 PS AL
TRANSMITTER
Operating wavelength (nm) 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1529.55-1561.61
1611
Modulation - -
18
Application code is in reference to ITU-T Recommendation G.691.
RECEIVER
TRANSMITTER
RECEIVER
19
Application code is in reference to ITU-T Recommendation G.691.
Min. sensitivity (BER of 1*10-12) -20 -20 -22.5 -22.5 -24 -24
EOL (dBm)
Connector RJ-45
MXP10 1 Base card for multirate combiner, transponder or ADM on Card supporting 12 CSFP
(6 x SFP) ports of GbE, FC1/2/4, STM-1/4/16/64, OTU1. Supports FEC and EFEC on
the line side.
OM_AOC4 Optical module for up to 4 x SFP based ports , one module per MXP10 card
Function/
Card
Description
OTGBE_LX Optical GbE/FC/FICON transceiver, long reach, 1310 nm single mode fiber
OTGBE_ZX Optical GbE/FC/FICON transceiver, very long reach, 1550 nm single mode fiber
OTGBE_S3BD Bi-directional GbE SFP with 1310nm TX/1490nm Rx. Short Range (10km)
OTGBE_S5BD Bi-directional GbE SFP with 1490nm TX/1310nm Rx. Short Range (10km)
ETSDI Electrical SFP for DVB-ASI, SDI & HD-SDI signals over 75 ohm coaxial cables
OTC25_PSxx 2.7 Gbps CWDM transceiver (with or without outband FEC), short haul with PIN receiver
OTC25_ALxx 2.7 Gbps CWDM transceiver (with or without outband FEC), long haul with APD receiver
OTR25_AVxx DWDM SFP: 2.5/2.7G transceiver 2400 ps/nm, channel xx, LC connectors
OTR25_ABxx DWDM SFP: 2.5/2.7G transceiver 3240 ps/nm, channel xx, LC connectors
OTP8_xx 8.5 GBS FC8 SFP+ MM and 1310 nm for 150 m/10 km
STM-4 104
STM-16 49
STM-64 28
STM-4 142
STM-16 95
STM-64 79
STM-4 227
STM-16 170
STM-64 157
FC1200 32.12
FC800 42.02
STM64 42
ETY 1G 66.45
ETY 1G 117.12
ETY 1G 192.01
NOTE: The suffix xx in the module name designates the distance (nominal compensation
length) in km.
Nominal compensation length Typical dispersion @ 1549.32 nm [ps/nm] Max. insertion loss [dB]
0 - 60 km 960 2.65
4.17.3 Timing
Any of the following clock sources can be selected as a timing reference:
Any Dslot (SM_CODIR_4E, SM_V35_V11)
Internal clock source
SDH distributed timing
Two of 32 possible clocks derived from the card’s E1 mappers and framers (SM_10E only)
Two of 16 possible clocks recovered from CES E1 (EM_10E only)
4.17.14.1 General
Maximum number of channels per 2
module
Maximum number of channels per 6
card
Maximum number of channels per 18
shelf
APPLICATION CODE 20 MM
TRANSMITTER
RECEIVER
20
Application code is in reference to ITU-T Recommendation G.691.
4.18.1 Dimensions (H x W x D)
NPT-1021 shelf 44.4 mm x 440 mm x 243 mm
INF-B1U 20 mm x 76 mm x 222 mm
INF-B1U-D 40 mm x 76 mm x 222 mm
AC_PS-B1U 40 mm x 76 mm x 222 mm
EXT-2U shelf 88.9 mm x 443.4 mm x 243 mm
EXT-2U shelf traffic card 26 mm x 283 mm x 222 mm
INF-E2U 26 mm x 111 mm x 222 mm
AC_PS-E2U 52 mm x 111 mm x 222 mm
FCU-E2U 85 mm x 40 mm x 222 mm
Racks 2200/2600 mm x 600 mm x 300 mm
4.18.2 Weight
NPT-1020/NPT-1021 fully populated 4.5 kg
EXT-2U fully populated 7.5 kg
4.18.3 Power
Applicable specification ETSI 300 132-2
Input DC voltage -40 VDC to -72 VDC
Nominal DC power source -48 VDC
Input AC voltage 110 VAC to 230 VAC; 50 Hz/60 Hz
Nominal AC power source 220 VAC or 110 VAC
CAUTION: The maximum allowed input DC voltage when using PoE is -58 VDC.
4.18.4 INF_E2U
DC output voltage -48 VDC to -70 VDC
Maximum output load power 511 W (including PoE)
Working temperature -25° C to +70° C
Storage temperature range -40° C to +70° C
4.18.6 AC_PS-E2U
AC input voltage range 100 VAC to 240 VAC; 50 Hz/60 Hz
DC output voltage -48 VDC to -70 VDC
Maximum output load power 200 W
Working temperature -5° C to +55° C
Storage temperature range -40° C to +70° C
4.18.9.1 Operation
Applicable specification ETSI-300-019-2-3 Class 3.3
Temperature range -25°C to +70°C
Relative humidity 5% to 95%
4.18.10 EMC
Applicable specifications EN 300 386/2000
Applicable directive EMC directive 89/336 EEC
4.18.11 Safety
Applicable specifications EN 60950/2000
Applicable CE directive LVD directive 73/23/EEC
4.18.13 Reliability
This section describes the reliability of the NPT-1010 platform with respect to product life and availability.
4.18.13.1 Life
Expected lifetime of the NPT-1021 15 years
4.18.13.2 Availability
Availability of service for an end-to-end service better than 99.999%
trail passing through a protected packet network
Packet switching card type Slot # Capacity per slot NPT-1050 total capacity
MCPS100 TS1 to TS3 20 Gbps 100 Gbps
5.3 Redundancy
DC power system INF-B1UH/INF-E2U 1+1 redundancy
Control (MCP) MCPS100 1 + 1 redundancy
Switching MCPS100 1 + 1 redundancy
TMU MCPS100 1+1 redundancy
1588v2 MCPS100 1+1 redundancy
5.5 Synchronization
Support ITU-T G.8262 EEC Option I and Option II.
There are four types of timing references available from multiple timing sources:
From any GbE/10GbE port which supports synchronous Ethernet
G.813 internal clock
Synchronization Status Marker (SSM) is provided
1588v2 Boundary Clock (on MCPS100 ) and Ordinary Clock (on MCPS100)
21
Depends on the network conditions and PTP protocol configuration, and limited by 2000 pps budget.
5.10 Management
Applicable specifications G.784, G.774, M.3010, M.3100
LightSoft (ECI Telecom Network on SUN workstation(s)
Manager) server and client for
managing all ECI Telecom
equipment
EMS-APT (element manager) on PC or SUN workstation(s)
LCT-APT (local craft terminal) on PC
SFP transceiver name OTR1_S3 OTR1_L3 OTR1_L5 OTR1_X3 OTR1_X5 OTR1_VL5 OTR1_VLC5
Operating wavelength (nm) 1261-1360 1263-1360 1480-1580 1270-1360 1500-1520 1500-1520 1544.5-1557.5
TRANSMITTER
RECEIVER 23
Min. sensitivity (BER of -28 -34 -34 -37 -35 -42 -42
1 * 10-12) EOL (dBm)
22
Application code is in reference to ITU-T Recommendation G.691.
23
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR1-S3BD can work only vis-a-vis OTR1-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
TRANSMITTER
RECEIVER 27
Min. sensitivity (BER of 1 * 10-12) -32 -32 -32 -32 -34 -34
EOL (dBm)
24
Application code is in reference to ITU-T Recommendation G.691.
25
BD 3: STM-1 single-fiber bidirectional SFP module with a 1310 nm TX wavelength.
26
BD 5: STM-1 single-fiber bidirectional SFP module with a 1550 nm TX wavelength.
27
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
TRANSMITTER
Min. sensitivity (BER of 1 * 10-12) EOL (dBm) -28 -28 -28 -34 -29
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR4-S3BD can work only vis-a-vis OTR4-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
28
Application code is in reference to ITU-T Recommendation G.691.
29
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
NOTE: OTR16 bidirectional SFPs (in the following table) are multirate transceivers that
support both STM-4 and STM-16.
TRANSMITTER
30
Application code is in reference to ITU-T Recommendation G.691.
31
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
TRANSMITTER
RECEIVER 33
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR1-S3BD can work only vis-a-vis OTR1-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
32
Application code is in reference to ITU-T Recommendation G.691.
33
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
TRANSMITTER
RECEIVER 35
Max. dispersion - - - - -
(ps/nm)
Max. discrete - - - - - -
reflectance (dB)
34
Application code is in reference to ITU-T Recommendation G.691.
35
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
CWDM DWDM
TRANSMITTER
RECEIVER 36
Min. sensitivity (BER of 1 * 10-12) EOL (dBm) -21.5 -28 -28 -28
36
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
Card MPoE_12G
5.12.1 MCPS100
10 GbE interface type (SFP+) 10GBase-SR, LR, LRM, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
Number of 10 GbE ports 2
Number of GbE ports 2/4 (SFP/CSFP)
Number of Sync-E ports 2
Supported types of 1588v2 PTP Clock BC, OC (slave or master), and two-step E2E TC
Number of Sync-E Tx Timing domains 2 (system and PTP clock)
Switch capacity 72 Gbps (for IMIX)
MAC address table capacity per switch 128 K
MAC address table capacity per VSI 64 K
Supported VLAN quantity 4000 * 4094, as per IEEE 802.1ad
Supported C-VLAN groups 16000
Supported MPLS P2P tunnels queues 16000
Supported Bidirectional LSPs 2048
Maximum number of LSP1:1 Linear 900
Protection Domains
Tunnel incoming label space for pass 16~32767
through
Tunnel incoming label space for drop 32768~262143
Supported MPLS P2MP tunnels 32
Supported maximum PWs 16000
Max number of PW redundancy groups 16
(without PW status signaling)
Max number of PW Redundancy with PW 1024
state signaling or PW with PW status
signaling
Supported maximum VSIs 4000
Supported maximum policers 4000
Supported maximum policer profiles 256
CIR/EIR granularity of policer 64Kb/s (0~2Mb/s)
1Mb/s (2Mb/s~full port rate)
CIR granularity of high CoS shaper 128K~512Kbps@128Kbps
1~16Mbps@1Mbps
16~64Mbps@2Mbps
64~256Mbps@4Mbps
256~1280Mbps@8Mbps
1280~5120Mbps@256Mbps
6000~10000Mbps@1000Mbps
CIR granularity for low CoS bandwidth 128K~512Kbps@128Kbps
1~16Mbps@1Mbps
16~64Mbps@2Mbps
64~256Mbps@4Mbps
256~1280Mbps@8Mbps
1280~5120Mbps@256Mbps
6000~10000Mbps@1000Mbps
PIR granularity for E-LSP bandwidth limit 1~ No Rate Limit@1Mbps
Maximum sites per VPLS instance 170-number of local ports
5.12.2 AIM100
10GBE Interface connector type 2 x SFP+
Supported 10 GbE interface port types 10GBase-SR, LR, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
GbE interfaces 2 x SFP or 4 x CSFP
Supported GBE port types 1000Base-SX, LX, EX, ZX ,BD ,colored, CSFP
10/100/1000Base-T (with ETGBE)
Maximum number of 10GBase-R ports 2
Maximum number of 10GBase-W ports 2
Maximum 1000Base-X interfaces 4 (with CSFP)
2 (with SFP)
Maximum 100Base-X interfaces 4 (with CSFP)
2 (with SFP)
Maximum 10/100/1000Base-T interfaces 2 (with ETGBE)
Number of Sync-E ports 6 (all ports)
Number of Sync-E Tx clock domains 1 (System clock)
Standards compliance IEEE802.3
ITU-T G.8262
5.12.3 DHXE_2
Interface connector type 2 x SFP+
Supported port types 10GBase-SR, LR, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
Maximum number of 10GBase-R 2
ports
Maximum number of 10GBase-W 2
ports
Number of Sync-E ports 2 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
5.12.4 DHGE_4E
Interface connector type 4 x RJ45
Supported ports 4 x 10/100/1000Base-Tx with PoE+ support
PoE PSE pin-out IEEE 802.3af, Alternative A
Supported PD type IEEE 802.3at type 1, type 2
Maximum PoE power per port 30 W
5.12.5 DHGE_8
Interface connector type 4 x SFP
Supported port types 1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
10/100/1000Base-T
Maximum number of 1000Base-X ports 8 (with CSFP)
4 (with SFP)
Maximum number of 100Base-FX ports 8 (with CSFP)
4 (with SFP)
Maximum number of 10/100/1000Base-T ports 4 (with copper SFP – ETGBE)
Number of Sync-E ports 8 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
5.12.6 DHGE_16
Interface connector type 8 x RJ45
4 x SFP (SFP/CSFP compatible)
Supported port types 10/100/1000Base-Tx
1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
Maximum number of 10/100/1000Base-Tx 8 +4 (with copper SFP – ETGBE)
ports
Maximum number of 1000Base-X ports 8 (with CSFP)
4 (with SFP)
Maximum number of 100Base-FX ports 8 (with CSFP)
4 (with SFP)
Number of Sync-E ports 16 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
5.12.7 DHGE_24
Interface connector type 12 x SFP (SFP/CSFP compatible)
Supported port types 1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
Maximum number of 1000Base-X ports 24 (with CSFP)
12 (with SFP)
Maximum number of 100Base-FX ports 24 (with CSFP)
12 (with SFP)
Maximum number of 12 (with copper SFP – ETGBE)
10/100/1000Base-Tx ports
Number of Sync-E ports 24 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
5.12.8 DHFE_12
Interface connector type 12 x RJ-45
Supported port types 10/100Base-T
Maximum number of 10/100Base-T 12
ports
Standards compliance IEEE802.3
5.12.9 DHFX_12
Interface connector type 12 x SFP
Supported port types 100Base-FX
Maximum number of 100Base-FX ports 12
Standards compliance IEEE802.3
5.12.10 DMCES1_4
Interfaces 4 x channelized STM-1(SFP)
1 x channelized STM-4 (SFP)
1 x GbE SFP
CES service Unstructured E1 (SAToP)
Channelized E1 (CESoPSN)
Number of CES services 252
Encapsulation Protocol in standalone mode CESoETH, CESoIP/UDP
Encapsulation Protocol in integration mode CESoETH and CESoMPLS
5.12.11 DMCE1_32
Interfaces 32 x E1
1 x GbE Combo
CES service Unstructured E1 (SAToP)
Channelized E1 (CESoPSN)
Number of CES services 32
Encapsulation Protocol in standalone mode CESoETH, CESoIP/UDP
Encapsulation Protocol in integration mode CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR RTP 19.44 MHz
timestamp 25 MHz
Adaptive timing domain 32
Differential timing domain 32
Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000us@125us
Jitter buffer Max delay var 1000-64000 @1000 µsec
Jitter buffer Min latency 500-32000 @500 µsec
Standards compliance IEFT RFC4553, RFC5086
MEF8, MEF3
ITU-T Y.1413, G.703
5.12.12 MSE1_16
Interfaces 16 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES service 16
Encapsulation Protocol CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR 19.44 MHz
RTP timestamp 25 MHz
Adaptive timing domain 16
Differential timing domain 16
Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000us@125us
Jitter buffer Max delay var 1000-64000 @1000 µsec
Jitter buffer Min latency 500-32000 @500 µsec
Standards compliance IEFT RFC4553, RFC5086
MEF8, MEF3
ITU-T Y.1413, G.703
5.12.13 MSC_2_8
Interfaces 2 x Channelized STM-1/OC-3 (SFP)
8 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES service 126 x E1 (over 2 x STM1) + 8 x E1
OR
168 x DS1 (over 2 x OC-3) + 8 x DS1
Encapsulation Protocol CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR 19.44 MHz
RTP timestamp 25 MHz
Adaptive timing domain 134/176 (Per E1/DS1)
Differential timing domain 134/176 (Per E1/DS1)
5.12.14 MPoE_12G
Interface type 4 x 1000Base-X/100Base-FX
8 x 10/100/1000Base-Tx with PoE
PSE pin-out IEEE 802.3af, Alternative A
Supported PD type IEEE 802.3at type 1, type 2
Maximum PoE power per port 30 W
Maximum PoE power per card 90 W
Number of Sync-E ports 12 (all GbE ports)
Supported types of 1588v2 PTP Clock OC (slave or master)
Two-step TC
Switch capacity 10 Gbps
MAC address table capacity 128 K
MAC address table capacity per VSI 64 K
Supported VLAN quantity 4000 * 4094, as per IEEE 802.1ad
Supported C-VLAN groups 16000
Supported MPLS P2P tunnel queues 8000
Supported Bidirectional LSPs 2048
Maximum number of LSP1:1 Linear 1024
Protection Domains
Supported MPLS P2MP tunnels 32
Supported maximum PWs 16000
Supported maximum VSIs 4000
Supported maximum policers 4000
Supported maximum policer profiles 128
CIR/EIR granularity of policer 64Kb/s (0~2Mb/s)
1Mb/s (2Mb/s~full port rate)
Transmitter type GbE/FC1/ GbE/FC1/ GbE/FC1/ GbE/FC1/ FX, short-reach FX, short-reach
FICON(2) FICON(2) FICON(2) laser, 1310 laser, 1310 nm,
FICON(2) long-reach laser, very long-reach very long-reach multimode single mode
short-reach 1310 nm, single laser, 1550 nm, laser, 1550 nm,
laser, 850 nm, mode single mode single mode
multimode
Typical Rx LOS -24 -29 -25 -25 < -33 < -28
level (dBm)
Connector LC LC LC LC LC LC
Transmitter type Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP,
1310 nm 1490 nm 1310 nm e 1490 nm 1490 nm 1590 nm
Average receiver < -21 < -21 < -23 < -23 -26 -26
sensitivity (dBm)
Typical Rx LOS level < -22 < -22 < -24 < -24 < -26 < -26
(dBm)
Connector LC LC LC LC LC LC
Fiber lengths 10 km 10 km 40 km 40 km 80 km 80 km
(9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF)
CWDM DWDM
TRANSMITTER
37
New optical SFP transceivers for existing SIO16 basecard.
38
Application code is in reference to ITU-T Recommendation G.691.
CWDM DWDM
RECEIVER
Min. sensitivity (BER of 1*10-12) EOL (dBm) -21.5 -28 -28 -28
(-23 GbE) (-32 GbE)
TRANSMITTER
Spacing (GHz) NA NA NA NA NA NA -
39
Application code is in reference to ITU-T Recommendation G.691.
RECEIVER
Min. Attenuation 5 5 11 0 0 0 -
(dB)
Min. sensitivity (BER -14.1 -14.1 -24 -11 -12.6 -6.5 -22
of 1*10-12)
EOL (dBm)
OPTICAL PATH
BETWEEN S & R
Source type CWDM DFB CWDM DFB CWDM DFB CWDM DFB
40
Application code is in reference to ITU-T Recommendation G.691.
APPLICATION CODE 41 PS AL
TRANSMITTER
Operating wavelength (nm) 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1529.55-1561.61
1611
Modulation - -
41
Application code is in reference to ITU-T Recommendation G.691.
RECEIVER
TRANSMITTER
RECEIVER
42
Application code is in reference to ITU-T Recommendation G.691.
Min. sensitivity (BER of 1*10-12) -20 -20 -22.5 -22.5 -24 -24
EOL (dBm)
Connector RJ-45
MXP10 1 Base card for multirate combiner, transponder or ADM on Card supporting 12 CSFP
(6 x SFP) ports of GbE, FC1/2/4, STM-1/4/16/64, OTU1. Supports FEC and EFEC on
the line side.
OM_AOC4 Optical module for up to 4 x SFP based ports , one module per MXP10 card
Function/
Card
Description
OTGBE_LX Optical GbE/FC/FICON transceiver, long reach, 1310 nm single mode fiber
OTGBE_ZX Optical GbE/FC/FICON transceiver, very long reach, 1550 nm single mode fiber
OTGBE_S3BD Bi-directional GbE SFP with 1310nm TX/1490nm Rx. Short Range (10km)
OTGBE_S5BD Bi-directional GbE SFP with 1490nm TX/1310nm Rx. Short Range (10km)
ETSDI Electrical SFP for DVB-ASI, SDI & HD-SDI signals over 75 ohm coaxial cables
OTC25_PSxx 2.7 Gbps CWDM transceiver (with or without outband FEC), short haul with PIN receiver
OTC25_ALxx 2.7 Gbps CWDM transceiver (with or without outband FEC), long haul with APD receiver
OTR25_AVxx DWDM SFP: 2.5/2.7G transceiver 2400 ps/nm, channel xx, LC connectors
OTR25_ABxx DWDM SFP: 2.5/2.7G transceiver 3240 ps/nm, channel xx, LC connectors
OTP8_xx 8.5 GBS FC8 SFP+ MM and 1310 nm for 150 m/10 km
STM-4 104
STM-16 49
STM-64 28
STM-4 142
STM-16 95
STM-64 79
STM-4 227
STM-16 170
STM-64 157
FC1200 32.12
FC800 42.02
STM64 42
ETY 1G 66.45
ETY 1G 117.12
ETY 1G 192.01
NOTE: The suffix xx in the module name designates the distance (nominal compensation
length) in km.
Nominal compensation length Typical dispersion @ 1549.32 nm [ps/nm] Max. insertion loss [dB]
0 - 60 km 960 2.65
Nominal compensation length Typical dispersion @ 1549.32 nm [ps/nm] Max. insertion loss [dB]
5.16.3 Timing
Any of the following clock sources can be selected as a timing reference:
Any Dslot (SM_CODIR_4E, SM_V35_V11)
Internal clock source
SDH distributed timing
Two of 32 possible clocks derived from the card’s E1 mappers and framers (SM_10E only)
Two of 16 possible clocks recovered from CES E1 (EM_10E only)
5.16.14.1 General
Maximum number of channels per 2
module
Maximum number of channels per 6
card
Maximum number of channels per 18
shelf
APPLICATION CODE 43 MM
TRANSMITTER
RECEIVER
43
Application code is in reference to ITU-T Recommendation G.691.
5.17.1 Dimensions (H x W x D)
NPT-1050 shelf 44 mm x 483 mm x 243 mm
MCPTS100 20 mm x 158 mm x 212 mm
MCPS100 20 mm x 158 mm x 212 mm
INF_B1UH 20 mm x 76 mm x 212 mm
FCU_1050 41 mm x 44 mm x 224 mm
EXT-2U shelf 88.9 mm x 443.4 mm x 243 mm
EXT-2U shelf traffic card 26 mm x 283 mm x 222 mm
INF_E2U 26 mm x 111 mm x 222 mm
FCU_E2U 85 mm x 40 mm x 222 mm
Racks 2200/2600 mm x 600 mm x 300 mm
5.17.2 Weight
NPT-1050 fully populated 8 kg
EXT-2U fully populated 7.5 kg
5.17.3 Power
Applicable specification ETSI 300 132-2
Input DC voltage -40 VDC to -72 VDC
Nominal DC power source -48 VDC
NPT-1050 power consumption Maximum 450 W
EXT-2U power consumption Maximum 511 W (including PoE)
CAUTION: The maximum allowed input DC voltage when using PoE is - 58 VDC.
5.17.4 INF-B1UH
DC input voltage -48 VDC to -70 VDC
Maximum output load power 450 W
Working temperature -25° C to +70° C
Storage temperature range -40° C to +70° C
5.17.5 INF_E2U
DC output voltage -48 VDC to -70 VDC
Maximum output load power 511 W (including PoE)
5.17.6 AC_PS-E2U
AC input voltage range 100 VAC to 240 VAC; 50 Hz/60 Hz
DC output voltage -48 VDC to -70 VDC
Maximum output load power 200 W
Working temperature -5° C to +55° C
Storage temperature range -40° C to +70° C
NOTE: When using an air filter, the operational temperature is reduces by 5°C.
5.17.9 EMC
Applicable specifications EN 300 386/2000
Applicable directive EMC directive 89/336 EEC
5.17.10 Safety
Applicable specifications EN 60950/2000
Applicable CE directive LVD directive 73/23/EEC
5.17.12 Reliability
This section describes the reliability of the NPT-1050 platform with respect to product life and availability.
5.17.12.1 Life
Expected lifetime of the NPT-1200 15 years
5.17.12.2 Availability
Availability of service for an end-to-end service better than 99.999%
trail passing through a protected network
Packet switching card Slot # Capacity per slot NPT-1200 total capacity
type
CPS100 TS1 to TS7 (excluding TS5) 20 Gbps 100 Gbps
6.3 Redundancy
DC power system INF-1200/INF-E2U 1+1 redundancy
FAN Unit 1:N redundancy for FAN unit
Switching CPTS 1+1 redundancy
CPS 1 + 1 redundancy
Cross-connect matrix XIO64 1+1 redundancy
XIO16_4 1 + 1 redundancy
CPTS 1+1 redundancy
TMU XIO64 1+1 redundancy
XIO16_4 1 + 1 redundancy
CPTS100/320 1+ 1 redundancy
CPS100/320 1+1 redundancy
1588v2 CPTS 1+1 redundancy
CPS 1 + 1 redundancy
6.5 Synchronization
There are multiple types of timing references available from multiple timing sources:
From any GbE/10GbE port which supports synchronous Ethernet
An external input of 2 MHz and 2 Mbps
G.813 internal clock
1588v2 Boundary Clock (on CPTS100, CPS100 ) and Ordinary Clock (on CPTS100, CPS100,
DMXE_48_L2 and DMXE_22_L2)
Synchronization Status Marker (SSM) and Ethernet Synchronization Message Channel (ESMC) are
provided
44
Depends on the network conditions and PTP protocol configuration, and limited by 2000 pps budget.
6.11 Management
Applicable specifications G.784, G.774, M.3010, M.3100
LightSoft (ECI Telecom Network on SUN workstation(s)
Manager) server and client for
managing all ECI Telecom
equipment
EMS-APT (element manager) on PC or SUN workstation(s)
LCT-APT (local craft terminal) on PC
SFP transceiver name OTR1_S3 OTR1_L3 OTR1_L5 OTR1_X3 OTR1_X5 OTR1_VL5 OTR1_VLC5
Operating wavelength (nm) 1261-1360 1263-1360 1480-1580 1270-1360 1500-1520 1500-1520 1544.5-1557.5
TRANSMITTER
RECEIVER 46
Min. sensitivity (BER of -28 -34 -34 -37 -35 -42 -42
1 * 10-12) EOL (dBm)
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR1-S3BD can work only vis-a-vis OTR1-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
45
Application code is in reference to ITU-T Recommendation G.691.
46
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
TRANSMITTER
RECEIVER 50
Min. sensitivity (BER of 1 * 10-12) -32 -32 -32 -32 -34 -34
EOL (dBm)
47
Application code is in reference to ITU-T Recommendation G.691.
48
BD 3: STM-1 single-fiber bidirectional SFP module with a 1310 nm TX wavelength.
49
BD 5: STM-1 single-fiber bidirectional SFP module with a 1550 nm TX wavelength.
50
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
51
Application code is in reference to ITU-T Recommendation G.691.
TRANSMITTER
Min. sensitivity (BER of 1 * 10-12) EOL (dBm) -28 -28 -28 -34 -29
NOTE: When selecting bidirectional transceivers, pay attention that they must operate in
complementary pairs. For example: OTR4-S3BD can work only vis-a-vis OTR4-S5BD;
OTR4-L3BD can work only vis-a-vis OTR4-L5BD, and so on. The transceivers in the following
table are arranged in complementary pairs.
NOTE: OTR16 bidirectional SFPs (in the following table) are multirate transceivers that
support both STM-4 and STM-16.
52
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
TRANSMITTER
53
Application code is in reference to ITU-T Recommendation G.691.
54
Receiver units of SFPs (excluding bidirectional SFPs) are a wide-band type.
6.13.1 CPS100
10 GbE interface type (SFP+) 10GBase-SR, LR, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
Number of 10 GbE ports 2
Supported OTN mapping 10GBase-R mapping to OTU2e
10GBase-W mapping to OTU2
Supported FEC types ITU-T G.709 FEC
EFEC (ITU-T G.975.1 I.4)
EFEC (ITU-T G.975 I.7)
Number of Sync-E ports 2
Supported types of 1588v2 PTP Clock BC, OC (slave or master), and TC
Number of Sync-E Tx Timing domains 2 (system and PTP clock)
Switch capacity 100G Switching, TM 72 Gbps (for IMIX)
MAC address table capacity per switch 128 K
MAC address table capacity per VSI 64 K
Supported VLAN quantity 4000 * 4094, as per IEEE 802.1ad
Supported C-VLAN groups 16000
Supported MPLS P2P tunnels queues 16000
Supported Bidirectional LSPs 2048
Maximum number of LSP1:1 Linear 1024
Protection Domains
55
Four DHXE_2 cards can be assigned, but only six ports can be activated totally.
6.13.2 CPS320
10 GbE interface type (SFP+) 10GBase-SR, LR, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
6.13.3 DHXE_2
Interface connector type 2 x SFP+
Supported port types 10GBase-SR, LR, ER, ZR, BD, colored
10GBase-SW, LW, EW, ZW, BD, colored
Maximum number of 10GBase-R 2
ports
Maximum number of 10GBase-W 2
ports
Number of Sync-E ports 2 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
6.13.4 DHXE_4
Interface connector type 4 x SFP+
Supported port types 10GBase-SR, LR, ER, ZR, BD, colored
Maximum number of 10GBase-R 4
ports
Number of Sync-E ports 4 (all ports)
Number of Sync-E Tx clock domains 1 (System clock - T0)
Standards compliance IEEE802.3
ITU-T G.8262
6.13.5 DHGE_4E
Interface connector type 4 x RJ45
Supported ports 4 x 10/100/1000Base-Tx with PoE+ support
PoE PSE pin-out IEEE 802.3af, Alternative A
Supported PD type IEEE 802.3at type 1, type 2
Maximum PoE power per port 30 W
Maximum PoE power per card 62 W
Number of Sync-E ports 4 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
6.13.6 DHGE_8
Interface connector type 4 x SFP
Supported port types 1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
10/100/1000Base-T
Maximum number of 1000Base-X ports 8 (with CSFP)
4 (with SFP)
Maximum number of 100Base-FX ports 8 (with CSFP)
4 (with SFP)
Maximum number of 10/100/1000Base-T ports 4 (with copper SFP – ETGBE)
Number of Sync-E ports 8 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
6.13.7 DHGE_16
Interface connector type 8 x RJ45
4 x SFP (SFP/CSFP compatible)
Supported port types 10/100/1000Base-Tx
1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
Maximum number of 10/100/1000Base-Tx 8 +4 (with copper SFP – ETGBE)
ports
Maximum number of 1000Base-X ports 8 (with CSFP)
4 (with SFP)
Maximum number of 100Base-FX ports 8 (with CSFP)
4 (with SFP)
Number of Sync-E ports 16 (all ports)
Number of Sync-E Tx clock domains 2 (System clock, PTP clock)
Standards compliance IEEE802.3
ITU-T G.8262
6.13.8 DHGE_24
Interface connector type 12 x SFP (SFP/CSFP compatible)
Supported port types 1000Base-SX, LX, EX, ZX, BD, Colored
100Base-FX (SM and MM)
Maximum number of 1000Base-X ports 24 (with CSFP)
12 (with SFP)
6.13.9 DHFE_12
Interface connector type 12 x RJ-45
Supported port types 10/100Base-T
Maximum number of 10/100Base-T 12
ports
Standards compliance IEEE802.3
6.13.10 DHFX_12
Interface connector type 12 x SFP
Supported port types 100Base-FX
Maximum number of 100Base-FX ports 12
Standards compliance IEEE802.3
6.13.11 DMCES1_4
Interfaces 4 x channelized STM-1(SFP)
1 x channelized STM-4 (SFP)
1 x GbE SFP
CES service Unstructured E1 (SAToP)
Channelized E1 (CESoPSN)
Number of CES services 252
Encapsulation Protocol in standalone mode CESoETH, CESoIP/UDP
Encapsulation Protocol in integration mode CESoETH and CESoMPLS
CES clock recovery mechanism Adaptive Clock Recovery (ACR)
Differential Clock Recovery (DCR)
Reference clock frequency for DCR RTP 19.44 MHz
timestamp 25 MHz
Number of ACR domains 32
Number of DCR domain 252
6.13.12 DMCE1_32
Interfaces 32 x E1
1 x GbE Combo
CES service Unstructured E1 (SAToP)
Channelized E1 (CESoPSN)
Number of CES services 32
Encapsulation Protocol in standalone mode CESoETH, CESoIP/UDP
Encapsulation Protocol in integration mode CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR RTP 19.44 MHz
timestamp 25 MHz
Adaptive timing domain 32
Differential timing domain 32
Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000us@125us
Jitter buffer Max delay var 1000-64000 @1000 µsec
Jitter buffer Min latency 500-32000 @500 µsec
Standards compliance IEFT RFC4553, RFC5086
MEF8, MEF3
ITU-T Y.1413, G.703
6.13.13 MSE1_16
Interfaces 16 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES service 16
6.13.14 MSC_2_8
Interfaces 2 x Channelized STM-1/OC-3 (SFP)
8 x E1/T1
CES service Unstructured E1/T1 (SAToP)
Channelized E1/T1 (CESoPSN)
Number of CES service 126 x E1 (over 2 x STM1) + 8 x E1
OR
168 x DS1 (over 2 x OC-3) + 8 x DS1
Encapsulation Protocol CESoETH, CESoMPLS
CES clock recovery mechanism Adaptive
Differential
Reference clock frequency for DCR 19.44 MHz
RTP timestamp 25 MHz
Adaptive timing domain 134/176 (Per E1/DS1)
Differential timing domain 134/176 (Per E1/DS1)
Tx Timing mode Recovered from CES stream
System timing
Loop timing
Payload time 125~8000 µsec@125 µsec
Jitter buffer Max delay var 1000-64000 @1000 µsec
Transmitter type GbE/FC1/ GbE/FC1/ GbE/FC1/ GbE/FC1/ FX, short-reach FX, short-reach
FICON(2) FICON(2) FICON(2) laser, 1310 laser, 1310 nm,
FICON(2) long-reach laser, very long-reach very long-reach multimode single mode
short-reach 1310 nm, single laser, 1550 nm, laser, 1550 nm,
laser, 850 nm, mode single mode single mode
multimode
Typical Rx LOS -24 -29 -25 -25 < -33 < -28
level (dBm)
Connector LC LC LC LC LC LC
Transmitter type Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional SFP, Bidirectional
1310 nm 1490 nm 1310 nm e 1490 nm 1490 nm SFP, 1590 nm
Average receiver < -21 < -21 < -23 < -23 -26 -26
sensitivity (dBm)
Typical Rx LOS level < -22 < -22 < -24 < -24 < -26 < -26
(dBm)
Connector LC LC LC LC LC LC
Fiber lengths 10 km 10 km 40 km 40 km 80 km 80 km
(9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF) (9 µm SMF)
CWDM DWDM
TRANSMITTER
RECEIVER
56
New optical SFP transceivers for existing SIO16 basecard.
57
Application code is in reference to ITU-T Recommendation G.691.
CWDM DWDM
Min. sensitivity (BER of 1*10-12) EOL (dBm) -21.5 -28 -28 -28
(-23 GbE) (-32 GbE)
TRANSMITTER
Spacing (GHz) NA NA NA NA NA NA -
58
Application code is in reference to ITU-T Recommendation G.691.
RECEIVER
Min. Attenuation 5 5 11 0 0 0 -
(dB)
Min. sensitivity (BER -14.1 -14.1 -24 -11 -12.6 -6.5 -22
of 1*10-12)
EOL (dBm)
OPTICAL PATH
BETWEEN S & R
Source type CWDM DFB CWDM DFB CWDM DFB CWDM DFB
59
Application code is in reference to ITU-T Recommendation G.691.
APPLICATION CODE 60 PS AL
TRANSMITTER
Operating wavelength (nm) 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1529.55-1561.61
1611
Modulation - -
60
Application code is in reference to ITU-T Recommendation G.691.
APPLICATION CODE 60 PS AL
RECEIVER
TRANSMITTER
RECEIVER
Min. sensitivity (BER of 1*10-12) -20 -20 -22.5 -22.5 -24 -24
EOL (dBm)
61
Application code is in reference to ITU-T Recommendation G.691.
Connector RJ-45
MXP10 1 Base card for multirate combiner, transponder or ADM on Card supporting 12 CSFP
(6 x SFP) ports of GbE, FC1/2/4, STM-1/4/16/64, OTU1. Supports FEC and EFEC on
the line side.
OM_AOC4 Optical module for up to 4 x SFP based ports , one module per MXP10 card
Function/
Card
Description
OTGBE_LX Optical GbE/FC/FICON transceiver, long reach, 1310 nm single mode fiber
OTGBE_ZX Optical GbE/FC/FICON transceiver, very long reach, 1550 nm single mode fiber
OTGBE_S3BD Bi-directional GbE SFP with 1310nm TX/1490nm Rx. Short Range (10km)
OTGBE_S5BD Bi-directional GbE SFP with 1490nm TX/1310nm Rx. Short Range (10km)
ETSDI Electrical SFP for DVB-ASI, SDI & HD-SDI signals over 75 ohm coaxial cables
OTC25_PSxx 2.7 Gbps CWDM transceiver (with or without outband FEC), short haul with PIN receiver
OTC25_ALxx 2.7 Gbps CWDM transceiver (with or without outband FEC), long haul with APD receiver
OTR25_AVxx DWDM SFP: 2.5/2.7G transceiver 2400 ps/nm, channel xx, LC connectors
OTR25_ABxx DWDM SFP: 2.5/2.7G transceiver 3240 ps/nm, channel xx, LC connectors
OTP8_xx 8.5 GBS FC8 SFP+ MM and 1310 nm for 150 m/10 km
STM-4 104
STM-16 49
STM-64 28
STM-4 142
STM-16 95
STM-64 79
STM-4 227
STM-16 170
STM-64 157
FC1200 32.12
FC800 42.02
STM64 42
ETY 1G 66.45
ETY 1G 117.12
ETY 1G 192.01
NOTE: The suffix xx in the module name designates the distance (nominal compensation
length) in km.
Nominal compensation length Typical dispersion @ 1549.32 nm [ps/nm] Max. insertion loss [dB]
0 - 60 km 960 2.65
6.17.3 Timing
Any of the following clock sources can be selected as a timing reference:
Any Dslot (SM_CODIR_4E, SM_V35_V11)
Internal clock source
SDH distributed timing
Two of 32 possible clocks derived from the card’s E1 mappers and framers (SM_10E only)
Two of 16 possible clocks recovered from CES E1 (EM_10E only)
6.17.14.1 General
Maximum number of channels per 2
module
Maximum number of channels per 6
card
Maximum number of channels per 18
shelf
APPLICATION CODE 62 MM
TRANSMITTER
RECEIVER
62
Application code is in reference to ITU-T Recommendation G.691.
6.18.1 Dimensions (H x W x D)
NPT-1200 shelf 88.9 mm x 442.4 mm x 243 mm
MCP1200 20 mm x 181 mm x 222 mm
CPS100 20 mm x 210 mm x 222 mm
INF_1200 31 mm x 76 mm x 222 mm
FCU_1200 86 mm x 44 mm x 222 mm
EXT-2U shelf 88.9 mm x 443.4 mm x 243 mm
EXT-2U shelf traffic card 26 mm x 283 mm x 222 mm
INF_E2U 26 mm x 111 mm x 222 mm
FCU_E2U 85 mm x 40 mm x 222 mm
Racks 2200/2600 mm x 600 mm x 300 mm
6.18.2 Weight
NPT-1200 fully populated 8 kg
EXT-2U fully populated 7.5 kg
6.18.3 Power
Applicable specification ETSI 300 132-2
Input DC voltage -40 VDC to -72 VDC
Nominal DC power source -48 VDC
NPT-1200 power consumption Maximum 550 W
EXT-2U power consumption Maximum 511 W (including PoE)
CAUTION: The maximum allowed input DC voltage when using PoE is - 58 VDC.
6.18.4 INF-1200
DC input voltage -48 VDC to -70 VDC
Maximum output load power 550 W
Working temperature -25° C to +70° C
Storage temperature range -40° C to +70° C
6.18.5 INF_E2U
DC output voltage -48 VDC to -70 VDC
Maximum output load power 511 W (including PoE)
Working temperature -25° C to +70° C
Storage temperature range -40° C to +70° C
6.18.6 AC_PS-E2U
AC input voltage range 100 VAC to 240 VAC; 50 Hz/60 Hz
DC output voltage -48 VDC to -70 VDC
Maximum output load power 200 W
Working temperature -5° C to +55° C
Storage temperature range -40° C to +70° C
NOTE: When using an air filter, the operational temperature is reduces by 5°C.
6.18.9 EMC
Applicable specifications EN 300 386/2000
Applicable directive EMC directive 89/336 EEC
6.18.10 Safety
Applicable specifications EN 60950/2000
Applicable CE directive LVD directive 73/23/EEC
6.18.12 Reliability
This section describes the reliability of the NPT-1010 platform with respect to product life and availability.
6.18.12.1 Life
Expected lifetime of the NPT-1200 15 years
6.18.12.2 Availability
Availability of service for an end-to-end service better than 99.999%
trail passing through a protected packet network
EN 300 386: Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication
network equipment; Electromagnetic Compatibility (EMC) requirements.
EN 300-417-2-1: Transmission and Multiplexing (TM); Generic requirements of transport functionality
of equipment.
EN 300-417-5-1: Generic requirements of transport functionality of equipment.
EN 300-462-5-1: Transmission and Multiplexing (TM); Generic requirements for synchronization
networks.
EN 50121 – 4 (2006) Railway applications - Electromagnetic compatibility part 4: emission and
immunity of signaling and telecommunications.
EN 50125-3 (2003) Railways applications – Environmental conditions for equipment – part 3:
Equipment for signaling and telecommunication.
EN50581 - Guiding Standard for Compliance with RoHS2 Technical Documentation Requirements
EN 55022: Radio Disturbance Characteristics of Information Technology Equipment.
EN 55024: 1998 +A1: 2001+A2:2003 Immunity characteristics-Limits and methods of measurements
EN 60950-1 (2006/ A11+A12+A1)) Equipment Safety Part-1: General Requirements.
EN 60870-2-2 (1996) Telecontrol equipment and system - Part 2Operation condition – Section 2:
Environmental condition (3k6).
EN 60950-1 -Information Technology Equipment Safety- Part1 General Requirements
EN 61000-4-2:1995 +A1:98+A2:2001 Electrostatic Discharge (ESD) Immunity test
EN 61000-4-3:2008 Electromagnetic compatibility (EMC), Section 3: Radiated, radio
frequency,electromagnetic field immunity IEC test
EN 61000-4-4: 2008 Electromagnetic compatibility (EMC), Section 4: Electrical fast transient/burst
immunity test
EN 61000-4-5: 2006 Electromagnetic compatibility (EMC), Section 5: Surge immunity test
EN 61000-4-6:2007 Electromagnetic compatibility (EMC), Section 6: Immunity to conducted
disturbances, induced by radio- frequency fields
EN 61000-6-5 (2001) Generic standards – Immunity for power station and substation environments
EN 61850-3 (2002) Communication network and systems in substations – Part 3: General
requirements
ETR 275: Considerations on Transmission Delay and Transmission Delay value for components on
connections supporting speech communication over evolving digital networks.
FTZ 1TR9: Deutsche Telekom A.G. EMC Requirements.
IEC 870-2-1:1995 Telecontrol equipment and systems - Part 2: Operating conditions -Section 1: Power
supply and electromagnetic compatibility.
IEC 917: Modular Order for the Development of Mechanical Structures for Electronic Equipment
Practices.
IEC 3309: Information Technology – Telecommunications and Information Exchange between Systems
– High-Level Data Link Control (HDLC) Procedures – Frame Structure.
IEC 9314-3: Information Processing Systems - Fiber Distributed Data Interface (FDDI) Multiplex.
IEC 9595, Information Technology: Open Systems Interconnection, Common Management
Information Services.
IEC 9596, Information Technology: Open Systems Interconnection, Common Management
Information Protocol.
IEC 13239: Information technology — Telecommunications and information exchange between
systems — High-level data link control (HDLC) procedures.
IEC 17025: General Requirements for Competence of Testing and Calibration Laboratories.
IEC 60825-1: Safety of Laser Products – Part 1: Equipment Classification and Requirements.
IEC 60825-2 (AS/NZS 2211.2): Safety of Laser Products – Part 2: Safety of Optical Fiber Communication
System (OFCS).
IEC/EN/UL 60950-1: Information Technology Equipment - Safety - General Requirements.
IS 1249-1: Safety of Laser products: Equipment classification requirements and users guide.
IEEE 1588: IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement
and Control Systems
IEEE 1613 (2003) Environmental and testing requirements for communication networking devices in
electric power station (class B).
RFC 4379: Detecting Multi-Protocol Label Switched (MPLS) Data Plane Failures.
RFC 4448: Encapsulation Methods for Transport of Ethernet over MPLS Networks.
RFC 4541: “Considerations for IGMP and MLD Snooping Switches”
RFC 4553: Structure-Agnostic Time Division Multiplexing (TDM) over Packet (SAToP)
RFC 5086: Structure-Aware Time Division Multiplexed (TDM) Circuit Emulation Service over Packet
Switched Network (CESoPSN)
RFC 5087: Time Division Multiplexing over IP (TDMoIP)
RFC 5254: Requirements for Multi-Segment Pseudowire Emulation Edge-to-Edge (PWE3).
RFC 5462: Multiprotocol Label Switching (MPLS) Label Stack Entry: "EXP" Field Renamed to "Traffic
Class" Field.
RFC 5586: MPLS Generic Associated Channel
RFC 5654: Requirements of an MPLS Transport Profile
RFC 5659: An Architecture for Multi-Segment Pseudowire Emulation Edge-to-Edge.
RFC 5718: An In-Band Data Communication Network For the MPLS-TP
RFC 5860: Requirements for OAM in MPLS-TP Networks
RFC 5880: Bidirectional Forwarding Detection (BFD)
RFC 5884: Bidirectional Forwarding Detection (BFD) for MPLS Label Switched Paths (LSPs)
RFC 5921: A Framework for MPLS in Transport Networks
RFC 5950: Network Management Framework for MPLS-TP Networks
RFC 5951: Network Management Requirements for MPLS-TP Networks
RFC 5960: MPLS-TP Data Plane Architecture
RFC 6073: Segmented Pseudowire.
RFC 6215 : MPLS-TP User-to-Network (UNI) and Network-to-Network Interfaces (NNI)
RFC 6370: MPLS-TP Identifiers
RFC 6371: OAM Framework for MPLS-TP Networks
RFC 6372: MPLS-TP Survivability Framework
RFC 6378: MPLS Transport Profile (MPLS-TP) Linear Protection
RFC 6423: Using the Generic Associated Channel Label (GAL) for Pseudowire in the MPLS-TP
RFC 6426: MPLS On-Demand Connectivity Verification and Route Tracing
RFC 6427: MPLS Fault Management Operations, Administration, and Maintenance (OAM)
RFC 6428: Proactive Connectivity Verification, Continuity Check, and Remote Defect Indication for the
MPLS Transport Profile
RFC 6378: MPLS Transport Profile (MPLS-TP) Linear Protection
RFC 6718: Pseudowire Redundancy
IETF Drafts:
draft-ietf-l2vpn-vpls-ldp.
draft-ietf-l2vpn-vpls-mcast-reqts.
draft-ietf-magma-snoop.
draft-ietf-mpls-rsvp-te-p2mp.
draft-ietf-mpls-tp-nm-framework.
draft-ietf-mpls-tp-nm-req.
draft-ietf-pwe3-dynamic-ms-pw-14.
draft-ietf-pwe3-ethernet-encap.
draft-ietf-pwe3-ldp-aii-reachability-04.
draft-martini-l2circuit-encap-mpls.
draft-sajassi-l2vpn-vpls-multicast-congruency.
draft-vasseur-mpls-backup-computation.
G.663: Application Related Aspects of Optical Fiber Amplifier Devices and Subsystems.
G.664: Optical Safety Procedures and Requirements for Optical Transport Systems.
G.671: Transmission Characteristics of Passive Optical Components.
G.691: Optical Interfaces for Single Channel SDH Systems with Optical Amplifiers and STM-64 Systems
(Draft).
G.692: Optical Interfaces for Multi-Channel Systems with Optical Amplifiers.
G.694.1: Spectral Grids for WDM Applications: DWDM Frequency Grid.
G.694.2: Spectral Grids for WDM Applications: CWDM Wavelength Grid.
G.695: Optical Interfaces for Coarse Wavelength Division Multiplexing Applications.
G.703: Physical/Electrical Characteristics of Hierarchical Digital Interfaces.
G.704: Synchronous Frame Structures Used at 1544, 6312, 2048, 8448 and 44 736 kbps Hierarchical
Levels.
G.706: Frame Alignment and CRC Procedures Relating to Basic Frame Structure Defined in Rec G.704.
G.707: Network Node Interface for the Synchronous Digital Hierarchy.
G.709: Interfaces for the Optical Transport Network (OTN).
G.752: Characteristics of digital multiplex equipments based on a second order bit rate of 6312 kbit/s
and using positive justification.
G.772: Protected Monitoring Points Provided on Digital Transmission Systems.
G.774 & G774.n: SDH Information Model.
G.775: Loss of Signal (LOS), Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) defect
detection and clearance criteria for PDH signals.
G.781: Synchronization Layer Functions.
G.783: Characteristics of SDH Equipment Functional Blocks.
G.784: Synchronous Digital Hierarchy (SDH) Management.
G.798: Characteristics of OTN Hierarchy Equipment Functional Blocks.
G.803: Architectures of Transport Networks based on the Synchronous Digital Hierarchy.
G.805: Generic Functional Architecture of Transport Networks.
G.806: Characteristics of Transport Equipment –Description Methodology and Generic Functionality.
G.809: Functional Architecture of Connectionless Layer Networks.
G.811: Timing Characteristics of Primary Reference Clocks.
G.812: Timing Requirements of Slave Clocks Suitable for Use as Node Clocks in Synchronization
Networks.
G.813: Timing Characteristics of SDH Equipment Slave Clocks (SEC).
G.823: The Control of Jitter and Wander within Digital Networks Based on the 2048 kbit/s Hierarchy.
G.825: The Control of Jitter and Wander within Digital Networks Based on the SDH (Draft).
G.8251: The Control of Jitter and Wander within the Optical Transport Network (OTN).
G.826: Error Performance Parameters and Objectives for International, Constant Bit Rate Digital Paths
at or above the Primary Rate.
G.841: Types and Characteristics of SDH Network Protection Architectures.
G.872: Architecture of Optical Transport Networks.
G.874: Management Aspects of the Optical Transport Network Element.
G.874.1: Optical Transport Network (OTN): Protocol-Neutral Management Information Model for the
Network Element View.
G.957: Optical Interfaces for Equipment and Systems relating to the Synchronous Digital Hierarchy.
G.958: Digital Line Systems Based on the Synchronous Digital Hierarchy for Use on Optical Fiber
Cables.
G.959.1: Optical Transport Network Physical Layer Interfaces.
G.975: Forward Error Correction for Submarine Systems.
G.985: 100 Mbit/s point-to-point Ethernet based optical access system.
G.7710/Y.1701: Common equipment management function requirements
G.7712: Architecture and specification of data communication network.
G.7713: Distributed Connection Management.
G.7714: Generalized Automatic Discovery Techniques.
G.7714.1: Protocol for Automatic Discovery in SDH & OTN network.
G.8010/Y.1306: Architecture of Ethernet Layer Networks.
G.8011/Y.1307: Ethernet Services Framework.
G.8011.1/Y.1307.1: Ethernet Private Line Service.
G.8011.2/Y.1307.2: Ethernet Virtual Private Line Service.
G.8012/Y.1308: Ethernet UNI and Ethernet NNI.
G.8032 V1/Y.1344: Ethernet ring protection switching
G.8112/Y.1371: Interfaces for the MPLS Transport Profile layer network
G.8113.2/Y.1372.2: Operations, administration and maintenance mechanisms for MPLS-TP networks
using the tools defined for MPLS
G.8201/Y.1354: Error performance parameters and objectives for multi-operator international paths
within the Optical Transport Network (OTN)
G.8261/Y. 1361: Timing and synchronization aspects in packet network.
G.8262/Y. 1362: Timing characteristics of synchronous Ethernet equipment slave clock (EEC).
G.8264: Distribution of timing information through packet networks
G.8265: Architecture and requirements for packet-based frequency delivery
M.2140: Transport Network Event Correlation.
M.3010: Principles for a Telecommunications Management Network.
M.3013: Considerations for a Telecommunications Management Network.
M.3016.x: Security for the management plane.