You are on page 1of 21

Water Management Solutions

Klargester
Product Guide
The Klargester range of fully integrated
wastewater management, surface water
and rainwater harvesting solutions

kingspan.ie/klargester
Water Management Solutions

About Kingspan Expert Technical


Support

Operating in over 85 Trusted Water Management Solutions


Kingspan’s support doesn’t stop once you have We stand by the quality and performance
of Kingspan water management solutions
countries worldwide, we Kingspan, manufacturers of the
Klargester Product Range, are the water
purchased the product. Our expert team are and our support doesn’t stop once your
tank is installed.
offer a global distribution management experts with over 60 years here to help you with technical, sales and delivery Our world class design consultancy is
network backed by of innovation and knowledge. We design
and manufacture tried and tested water enquiries. We are dedicated to our customers and complemented by engineering expertise
experienced local sales management solutions on a global scale pride ourselves on top class customer service. and advice as well as service throughout
your domestic, commercial or industrial
for the leisure, public, hospitality, transport
and technical teams. and domestic sectors whilst offering one water management project.
of the largest and most technologically We use the latest design technology
advanced wastewater ranges available. to produce drawings of extremely high
Our technical support teams provide quality. Our project management
focused customer service from delivery process is a step-by-step one, to ensure
scheduling to consultancy and installation the very best experience and results. It
guidance. We give you the confidence of covers everything from system sizing,
support over the lifetime of the product product selection and system design to
and beyond, in your local area. calculations, manufacturing, installation
and delivery.
Our advice also spans water management
specification, design, product application
and integration with building regulations,
code compliance and site work installation
practices to meet the most demanding
effluent qualities, flow rates and
discharge consents.
Contact our technical team today for
expert advice and information on any of
our water management solutions.
Email: water-IE@kingspan.com

Global Reach
Italy

France
Norway
UK & Ireland
Sweden
Spain Germany

USA
Poland

Turkey

Middle East

Asia—South East
Locally Nationwide
Accessible Distribution

Brisbane

Sydney
South America
Melbourne

— —
2 3
Water Management Solutions

Regional
Installations

Manufactured in the We offer free site visits to discuss project


specific requirements and provide a Kingspan
UK and Ireland, the detailed written report and specification to operates in over 85
countries worldwide,
recommend the best water management
Klargester Product Range solution for your project. with currently over
is supported by our We also provide on-site installation
5 million water
management
nationwide network of assistance when required and help you
with formal discussions with Building
system installations. Marble Arch Caves IRE
Social Housing Installation IRE
Multi-Housing Development
Dundee, Scotland
UK
Take a look at a Co. Fermanagh, N. Ireland Co. Louth, Ireland
dedicated external Area Control, Local Planning departments, selection of our
The Environment Agency/SEPA, Grease separator and BioDisc sewage Rainwater harvesting solution used A complex sewage treatment and surface
Sales Managers. architects and consultants.
case studies for the
Klargester Product treatment plant work together giving to flush the WCs in each home. The pumping solution to meet the varying
Range. optimum performance and extremely low system is fully integrated with the needs of multiple housing.
To arrange your free site survey contact us
running costs. main plumbing, easing demand on
now on 028 3026 6799 (NI); 048 3026 6799
the mains supply.
(ROI) or email water-IE@kingspan.com

Thanet Earth UK
Elite Office Furniture UK
Everton FC (Training Ground) UK
Dundee Kent, England Goole, England Liverpool, England

Four vertical pumping stations to aid Surface water separators, foul, effluent Modular BioFicient commercial system
water management for a complex and crude sewage pump stations, grease including fuel/oil separators for a complete
greenhouse development. trap and BioFicient commercial system. wastewater management solution.
Clifford

Co. Fermanagh
Liverpool

Co. Louth Goole

Manchester Manchester City FC The Castlefields Inn Primark Distribution Centre


UK UK UK
Manchester, England Clifford, England Kettering, England
Kettering
Oil separators for its all-important surface BioDisc commercial sewage treatment Modular BioFicient commercial system for
water drainage system. plant providing an efficient water multi-million pound distribution centre.
Wing
management solution.

London

Kent

Barn Conversion UK
Supermarket Car park UK
Wing, England London, England

Domestic BioDisc sewage treatment Bypass separator, NSBE50, to


plant, ensuring a safe, odour-free assist in decontamination of surface
environment. water drainage.
— —
4 5
Water Management Solutions

Klargester BioDisc® Noise Free

Domestic Sewage
Treatment Plant

The Klargester domestic Product Benefits The Rotational Biological Contactor Technical Specifications

BioDisc® is engineered ∙∙ Utilises Rotating Biological Contactor


technology.
The RBC is central to the operation of
each Klargester BioDisc®. It supports a
Model Reference BA* BA-X BB BC
Performance and
to treat wastewater ∙∙ Low running costs. biologically active film or biomass onto
Population Equivalent (Std Flow)
Maximum Daily BOD (kg)
6
0.36
9
0.54
12
0.72
18
1.08
Compliance

to the highest level of ∙∙ Low level visibility with a lockable child-


which aerobic micro-organisms, naturally
found in sewage, become established. Maximum Daily Flow (m3) 1.2 1.8 2.4 3.6
› Certified to
European
standards and offers one proof cover – safe for children and pets.
∙∙ For NIEA, BA-BC models deliver 95%
Natural breakdown of sewage can then Ø/Width (mm) Ø1995 Ø1995 Ø1995 Ø2450
Standard BS EN
occur as described below.
of the lowest lifetime 12566 Part 3.
Length (mm) - - - -
pollution removal, whilst the BioDisc+P
Inlet Invert depth (mm) 450/750/1250 450/750/1250 450/750/1250 600/1100 › Performance
costs compared to other achieves 97.8% for BOD removal.
∙∙ 10 year warranty options available
Depth Below Inlet Invert (mm) 1400 1400 1400 1820 certified to
treatment processes. when purchased with a service and Outlet Invert depth (mm) 1315 1315 1315 1735 achieve 10mg/l
BOD, 15mg/l
maintenance plan. Overall Height (mm) 2160/2460/2960 2160/2460/2960 2160/2460/2960 2825/3325
SS and 3.8mg/l
∙∙ Supplied with a control panel and alarm. Height to Rim of Cover (mm) 1945/2245/2745 1945/2245/2745 1945/2245/2745 2485/2985
ammonia.
Empty Weight (kg) 310/325/380 310/325/380 335/350/405 650/750
∙∙ Managed Flow System. › Fully marked in line
Standard Power Supply 1 phase 1 phase 1 phase 1 phase with the CPR 2013.
∙∙ Totally silent in operation.
Motor Rating - 1 Phase (Watts) 50 50 50 75
Applications: ∙∙ The most stable process in the market. › Building control
Full Load Current 1 Phase (amps) 0.51 0.51 0.51 1.1
∙∙ Controls the discharge volume. and S.R.66:2015
The Klargester domestic BioDisc® BA–BC Optional Power Supply N/A N/A N/A 3 phase compliant (BA
range is suitable for a variety of Control Panel Improved Motor Rating - 3 Phase (Watts) N/A N/A N/A 90 BioDisc).
applications including: performance to
Full Load Current 3 Phase (amps) N/A N/A N/A 0.38
97.8% BOD removal
with our new Sludge Return Pump Rating (watts) 250 250 250 250
BioDisc+P model
* BA BioDisc - S.R.66:2015 compliant.
(NI Region only)
BA BioDisc
Single & Barn S.R.66:2015
Multiple Homes Conversions Compliant First Stage Second Stage
Biological Treatment Biological Treatment

Final Settlement
Small Offices Light Industrial Tank
Premises Primary
Settlement Tank

Farms

01 02 03 04
Primary Settlement Tank First Stage Biological Treatment Second Stage Biological Treatment Final Settlement Tank

Wastewater and sewage flows into the primary settlement tank The liquor and fine solids then flow into the Biological Treatment The liquor is then fed forward at a controlled rate into Biological The clean liquid passes into the final settlement tank where it
where the large solids are retained for future removal. Zone 1 where the first stage of treatment occurs. Treatment Zone 2 for further cleaning. can be discharged to ground or watercourse.
— —
6 7
Water Management Solutions

Klargester BioFicient® Control Panel


Included

Domestic Sewage
Treatment Plant

The Klargester BioFicient® Product Benefits


Performance and
Technical Specifications

treatment plant provides ∙∙ Shallow Dig. Compliance Model Reference BioFicient 1 BioFicient 2 BioFicient 3 BioFicient 4 BioFicient 5 BioFicient 6

a reliable and effective ∙∙ New low energy compressor.


∙∙ Low level visibility with a lockable child-
›B
 S EN 12566 Part Population Equivalent 6 8 10 15 20 30
3 tested and
solution for domestic proof cover – safe for children and pets. approved.
Overall Diameter (mm) 1,540 1,420 1,420 1,920 1,920 1,920

applications without ∙∙ Suitable for installation in traffic areas


(structural advice required).
› Industry leading Length (mm) 2,500 3,760 3,760 3,230 4,390 6,220
NH4 (ammonia)
access to mains
1,830/2,330/ 1,830/2,330/ 2,300/2,800/ 2,300/2,800/
Depth (mm) 1,794-2,104 2,300/2,800/ 3,300
2,830 2830 3,300 3,300
∙∙ Supplied with a control panel and alarm. removal.
500-810/ 500/1,000/ 500/1,000/ 500/1,000/ 500/1,000/ 5,00/1,000/
drainage. Suitable for ∙∙ Easy to set up and operate. › Fully marked in
Inlet Invert (mm)*
500-810*
600-910/
1,500
600/1,100/
1,500
600/1,100/
1,500
630/1,130/
1,500
630/1,130/
1,500
630/1,130/
line with the CPR
homes with up to 30 ∙∙ Integral pump option available for
BioFicient 1-4. 2013.
Outlet Invert (mm)
555-865* 1,600* 1,600* 1,630* 1,630 1,630

people, the BioFicient is


Material MDPE GRP GRP GRP GRP GRP
›B
 uilding control
and S.R.66:2015
manufactured from high
Blower Ratings 50W 75W 75W 95W 115W 225W
compliant. 1,500 x 900+
Cover sizes 700 1,500 x 900 1,500 x 900 1,500 x 900+600** 1,500 x 900+600**
quality materials and Control Panel
Note: Optional inlet depth down to 1800mm
600**

uses the latest treatment *BioFicient IPS models only (Outlet Depth 320mm) | **BioFicient 4, 5, 6 has two shafts.

technology to deliver
a high level of water
discharge quality.

Applications

The Klargester domestic BioFicient® Final Settlement


1–6 range is suitable for use across the Tank
following applications: S.R.66:2015
Compliant

BioZone
Single & Barn
Multiple Homes Conversions

Primary
Settlement Tank

Small Offices Light Industrial


Premises 01 02 03
Primary Chamber Biozone 1 & 2 Final Settlement Tank

Raw sewage gravitates to the unit where it is received in the primary settlement zone. Solids are broken down by air agitated media in the Biozone. Fine solids are settled out in the final
Farms
Here, gross solids and other social debris settle to the bottom of the tank where they Media and liquid circulation in the Biozone is achieved through settlement tank. The Final effluent is
remain until the tank requires desludging. Settled sewage is displaced from primary the use of a compressor and diffuser, which introduces fresh air discharged via either gravity outlet or
zone and enters the first of two sequential moving aerated media reactors. into each compartment. The liquor is constantly recirculated and IPS (Integral Pump System) chamber.
contacts the moving media. As it does so, it is purified by the With regulatory approval, it is suitable
micro organisms growing on the surface of the media and within for discharge to a watercourse or
the moving liquor. Excess growth of biomass is shed as solid drainage field.
particles into the liquor.
— —
8 9
Water Management Solutions

Klargester BioFicient+® Easy to Install

Domestic Sewage
Treatment Plant

The Klargester BioFicient+ Product Benefits The Klargester BioFicient+ unit is a new
generation of package sewage treatment
Technical Specifications
Performance and
sewage treatment plant ∙∙ Shallow dig with minimal visual impact. plant developed to treat domestic Model BioFicient 1+ BioFicient 2+ Compliance
∙∙ Easy and affordable installation. sewage waste. With two sizes available,
provides a reliable and ∙∙ Low power consumption. it offers a simple and compact system
Population Equivalent 6 10 › Fully marked in
line with the CPR
effective solution, suitable ∙∙ Modern design allows for desludging
comprising three treatment zones within
a ‘uni-tank’ design.
Overall Diameter (mm) 1,690 2,010
2013.
for homes with up to 10 through the wide neck.
The moving aerated media process
Length (mm) 2,480 3,189
› Fully compliant,
∙∙ BioFicient+ conforms with NIEA 95% BOD tested and
people and is S.R.66:2015
Depth (mm) 2,355 2,785
removal. used is a compact development of the approved to IS
traditional biological process and provides Inlet Invert (mm)* 575-1,500 700-1,500
compliant. a more effective and complete means of Outlet Invert (mm) 675-1,600 800-1600
EN12566 / S.R.66:
2015.
sewage treatment.
Material MDPE MDPE › Conforms with
NIEA 95% BOD
Blower Ratings 50W 95W
removal.
Cover sizes 700 700
Applications
Note: Models BioFicient1+ and BioFicient 2+ available to NI Market only. Optional inlet depth down to 1800mm
The Klargester domestic BioFicient+ *BioFicient IPS models only (Outlet Depth 320mm)
range is suitable for a variety of
applications, including:

Conforms with NIEA


95% BOD removal
Single & Barn Final Settlement
Multiple Homes Conversions Tank
S.R.66:2015
Compliant

Small Offices Light Industrial


Premises Biozone

Primary
Farms Settlement Tank

01 02 03 04
Wastewater and sewage flows into the primary settlement Solids are broken down by air agitated media in the Biozone. The final settlement tank is where fine solids form to sludge. Final effluent is discharged from the final settlement tank.
tank where solids are settled out and retained. Settled sewage Media and liquid circulation in the Biozone is achieved through At preset intervals, portions of the sludge and liquor are returned With regulator approval, it is suitable for discharge to a
is displaced from primary zone and enters the aerated media the use of a compressor and diffuser, which introduces fresh air to the primary tank for additional treatment. The primary and watercourse or drainage field.
reactor (Biozone). into each compartment. The liquor is constantly recirculated final settlement zones should be emptied of sludge every 12
and contacts the moving media and as it does so, it is purified months.
by the micro organisms growing on the surface of the media
and within the moving liquor. Excess growth of biomass is shed
as solid particles into the liquor.
— —
10 11
Water Management Solutions

Klargester Selecting the Regulations


Compliant

Reed Beds Correct Solution

A reed bed is a Product Benefits


To ensure selection of Environmental Regulators and British
Water have developed the system selection Did you know?
filtration process used ∙∙ Tertiary treatment for new applications
with tight discharge consents.
the correct sewage process below, to help in guiding you If you have a septic
through the process to choose the correct
in conjunction with ∙∙ Satisfies new building regulations. treatment and disposal system to meet your requirements.
tank that discharges to
an open waterway or
a Klargester sewage ∙∙ Improved effluent quality for method to meet your drainage ditch, by law,
you will need to replace
treatment system to existing works.
∙∙ Very low maintenance.
requirements, expert this with a treatment
further enhance the ∙∙ Aesthetically pleasing and advice should be sought. system before you sell
your property.
quality of the effluent environmentally friendly. In all instances a sewage
∙∙ Easy to install and maintain.
migrating into a drainage ∙∙ Effluent discharge is typically improved
treatment plant should For expert advice
please call
field or surrounding by at least 50% providing reduced BOD be considered as the first 028 3026 6799 (NI);
and suspended solids.
watercourse. option. 048 3026 6799 (ROI)
or email
water-IE@kingspan.com

Is a gravity
Site Assessment connection possible?
YES Connect to Sewer
How it works

Do you have access to


a mains server? YES
2500 NO Pump Chamber

NO
Outlet from Outlet from
treatment plant treatment plant
800
Vp Vp Do you have sufficient land Septic Tank or
800 YES
< 12 or >100 12 - 100 space for drainage fluid? Sewage Treatment Plant

NO

Technical Specifications Do you have access


to a water course? YES Sewage Treatment Plant
(NI Region only)
Model Reference Population Equivalent Length (mm) Width (mm) Depth (mm) No. Required Outlet Size (mm)

HRB006 6 2500 800 800 2 110

HRB012 12 2500 800 800 4 110


NO Cesspool

— —
12 13
Water Management Solutions

Klargester Klargester
Alpha Septic Gamma Septic
Tank Tank

Klargester Alpha tanks Basic septic tanks only retain solids and
discharge effluent of low quality. The Performance & The Klargester Gamma Manufactured from tough polyethylene,
the tank is robust and lightweight which Performance &
provide a reliable and installation will not contaminate any Compliance tank is an affordable makes it easy to handle and install. Compliance
ditch, stream or other watercourse.
economic solution for However, many local authorities prohibit › Performance tested solution for domestic Due to its design features, the Gamma ›9
 9.97% efficiency
to BS EN 12566 Part tank is the perfect solution where a rating.
homes not connected their use. In all instances a sewage
treatment system should be considered 1 requirements. applications with an shallow dig installation is required, › BS EN 12566 Part 1
to mains drainage. as a first option. › Fully marked in efficiency rating of 99.97% reducing installation time and costs. approved.
line with the CPR —
Septic tanks may be installed, subject to 2013. – an industry benchmark. Product Benefits
› Fully marked in
line with the CPR
consent, in applications where:
2013.
∙∙ Soil is of suitable porosity. ∙∙ Manufactured from robust, impact
› Building control
resistant, high quality polyethylene.
∙∙ Installation complies with Building and S.R.66:2015
Regulations (Approved Document H). ∙∙ Strong, easy to move and simple to install. compliant.
∙∙ The installation will not contaminate any ∙∙ Lower excavation costs, less soil disposal
ditch, stream or other watercourse. and less backfill material.
∙∙ The plot is large enough. ∙∙ Wide neck for easy access for annual
desludging.

∙∙ Trimmable neck to suit site.
Product Benefits

∙∙ Made from composite GRP - strong, light,


and watertight.
∙∙ Press moulded shape provides wide,
Applications
squat, form which makes the tank easy to
install and handle. The Klargester Alpha and Gamma septic
∙∙ Stable base for storage. tank ranges, each comprise three sizes and
are typically suitable for applications not S.R.66:2015
∙∙ Lifting eyes are provided for lifting and
connected to mains drainage including: Compliant
positioning within the excavation.

Single and
Multiple Homes Churches Farms

Temporary
Golf Course Work Offices and
Toilet Facilities Mobile Homes Welfare Facilities

Technical Specifications Technical Specifications

No. People Overall Diameter Standard Inlet Standard Outlet No. People (150 Width Length Height Standard Inlet Standard Outlet Depth
Model Reference Volume (L) Height (mm) Model Reference Volume (L)
(150 Ltrs/head/day) (mm) Invert (mm) Invert (mm) Ltrs/head/day) (mm) (mm) (mm) Invert (mm) Invert (mm) (mm)
STS02810 2800 5 2075 2599/3099 1000/1500 1050/1550 GST028 2800 5 1130 2480 1755 - 2255 550-1050 550-1050 2255

STS03810 3800 12 2075 2810/3310 1000/1500 1050/1550 GST035 3500 10 1180 3000 1755 - 2255 550-1050 550-1050 2255

STS04610 4600 17 2084 2984/3484 1000/1500 1050/1550 GST040 4000 13 1215 3360 1755 - 2255 550-1050 550-1050 2255

— —
14 15
Water Management Solutions

Klargester Sigma Klargester Below Ground


Septic Tank Water Storage Tanks
and Cesspools

The Klargester Sigma Product Benefits


Performance and The range of Klargester The advanced design of the Klargester
below ground storage tanks ensures
Product Benefits

shallow dig septic tank is ∙∙ Made from GRP - strong and durable for Compliance below ground storage consistent high performance, even in the ∙∙ Easy to install with minimal on site
ultimate reliability. installation time.
designed to reduce both ∙∙ Robust and simple to install, reducing on
› Certified
 to BS EN tanks provide a reliable
toughest environmental conditions.
∙∙ Designed in accordance with BS6297,
installation time and cost. site installation time.
12566 Part 1
› Fully marked in
solution for the collection ensuring that you meet all building
regulations.
The range is available in ∙∙ Lower excavation costs, less soil disposal
and less backfill material required.
line with the CPR and retention of sewage ∙∙ High level alarm available for complete
various sizes suitable for ∙∙ Light, watertight and chemically
2013.
(cesspool), surface peace of mind.

properties with dig height resistant.


water, veterinary / animal ∙∙ Lockable manhole cover for
ultimate security.
∙∙ Robust, weatherproof for guaranteed
restrictions. durability, giving you value for money. waste, firefighting
reservoirs and rainwater
harvesting reservoirs.

Applications

Klargester Sigma septic tanks and below


ground water storage tanks and cesspools,
offer a solution for applications not
connected to mains drainage including:

Single and
Multiple Homes Churches Farms

Temporary
Golf Course Work Offices and
Toilet Facilities Mobile Homes Welfare Facilities

Technical Specifications Technical Specifications

No. People Overall Standard Inlet Standard Outlet Nominal Litres Capacity (Gallons) Length (mm) Diameter (mm)
Model Reference Volume (L) Length (mm) Depth (mm)
(150 Ltrs/head/day) Diameter (mm) Invert (mm) Invert (mm) 18,000 3960 4317 2620
22,000 4889 5073 2620
STH028 2800 5 1225 2955 500 530 1627/1587*
26,000 5720 5837 2620
STH038 3800 12 1225 3895 500 530 1617/1577* 34,000 7480 7376 2620

STH057 5700 24 1425 4275 500 530 1826/1786* 46,000 10,120 9684 2620
54,000 11,880 11,222 2620
STH071 7150 34 1920 3225 500 550 2290
59,000 12,968 11,991 2620
STH091 9150 47 1920 3960 500 550 2290 63,000 13,860 12,760 2620
71,000 15,620 14,295 2620
79,000 17,380 15,833 2620
*110mm diameter pipework/ 160mm diameter pipework
— —
16 17
Water Management Solutions

Klargester BioDisc® Single Piece


System

Commercial Sewage
Treatment Plant

Delivered as a single, Product Benefits


Performance & Compliance
Technical Specifications

packaged system, the ∙∙ Unique RBC technology.


› Odour
 free – fully tested and
Model Reference BD BE BF BG BH BJ BK BL BM BN

Klargester BioDisc® RBC ∙∙ Tried and tested technology, offers


robust and efficient water management
compliant with BS EN13725/NI
Maximum Daily BOD (kg) 1.5 2.1 3 4.2 4.5 6 7.5 9 13.5 18

Water approved.
range (up to 300PE),
Maximum Daily Flow (m3) 5 7 10 14 15 20 25 30 45 60
treatment.
› Designed
 for applications Ø/Width (mm) 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
offers low running ∙∙ Low running costs.
∙∙ Noise free.
selected in compliance with Length (mm) 3340 3340 4345 5235 7755 7755 7755 7755 10420 13100
British Water Code of Practice
costs due to its unique ∙∙ Fully removable lid for easy desludging. Flows and Loads. Inlet Invert depth (mm) 600/1100 600/1100 600/1100 600/1100 600/1000 600/1000 600/1000 600/1000 600/1000 600/1000

design and operational ∙∙ Fully packaged system, delivered direct › 100%


 compliance with
Depth Below Inlet Invert
(mm)
1820 1820 1820 1820 1790 1790 1790 1790 1790 1790
on site. industry requirements across
efficiencies. ∙∙ Bespoke technical support offered from commercial sectors, including
Outlet Invert Depth (mm) 1735 1735 1720 1720 1640 1640 1640 1640 1640 1640

national and international Overall Height (mm) 2825/3325 2825/3325 2825/3325 2825/3325 2830/3230 2830/3230 2830/3230 2830/3230 2830/3230 2830/3230
our in-house technical teams.
regulations such as BS Height to Rim of Cover
2485/2985 2485/2985 2485/2985 2485/2985 2490/2890 2490/2890 2490/2890 2490/2890 2490/2890 2490/2890
∙∙ Can be upgraded to include NI Water (mm)
EN12255 and EN12566-3 (up
Controls and desludge system for NI Empty Weight (kg) 1100/1200 1200/1300 1315/1465 1660/1810 3000/3020 3100/3120 3200/3220 3300/3320 4200/4250 5500/5650
to 50 PE).
Water adoption.
Standard Power Supply 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase
∙∙ Process designed to NIEA requirements. Motor Rating - 1 Phase
75 75 120 180 250 250 370 370 550 2 x 370
(Watts)
Full Load Current 1 Phase
1.1 1.1 1.3 1.6 1.5 1.5 2.35 2.35 2.8 2 x 2.35
(amps)
Optional Power Supply 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase
First Stage Second Stage Motor Rating - 3 Phase
90 90 120 180 250 250 370 370 550 2 x 370
Biological Treatment Biological Treatment (Watts)
Full Load Current 3 Phase
0.38 0.38 0.42 0.63 0.88 0.88 1.35 1.35 2.8 2 x 1.35
(amps)
Sludge Return Pump
250 250 250 250 250 250 250 250 250 250
Rating (watts)

Primary Final
Settlement Tank Settlement Tank

01 02 03 04
Primary Settlement Tank First Stage Biological Treatment Second Stage Biological Treatment Final Settlement Tank

This is the initial stage of treatment and simply involves the The liquor and fine solids then flow into the first stage of The liquor is then fed forward at a The surplus micro-organisms continuously slough off the discs and are carried forward
retention of coarse solids present in raw sewage and wastewater for Biological Treatment. A unique managed flow system ensures controlled rate into Biological Treatment to the final settlement where they settle out as a humus sludge, leaving a clear
subsequent gradual breakdown. BioDisc® features one chamber to peak performance by smoothing variable loads. stage 2 for further cleaning. This process treated effluent to be discharged to ground or water course. The settled humus sludge
ensure efficient operation with a flow balancing facility. ensures the whole media area available is is returned to the Primary Settlement Tank by the sludge return pump under timer
utilised ensuring maximum efficiency. control. The sludge return pump also removes any floating scum which helps to keep
the final settlement tank working efficiently.
— —
18 19
Water Management Solutions

Klargester BioDisc® Available in our


Modular System

Modular RBC Commercial


Sewage Treatment Plant

The larger Klargester The Klargester modular RBC system


is designed for applications with Modular RBC
Technical Specifications

BioDisc® modular RBC higher populations. System Model Reference Daily Flow (l/day) Daily Load (kg/BOD/day) Length(mm) Width(mm) Height(mm) Weight(kg) Motor Power

system is designed for The RBC comprises of a complete modular


system containing the RBC units along
The RBC comprises
RBC250 50,000 15 6,700 2,210 2,400 5,000 1.1 Kw/400v

a complete modular
applications with higher
Max daily flow based on 200 L/Person/Day, system PE will vary by site flow rate per person.
with primary and final settlement tanks. system, supplied
populations, with each Both the RBC units and tanks can be
increased in numbers or size to make a
as 250PE modules.
Their unique design
unit supplied as a flexible system for an expanding or phased is containerised for Sectional Media Rotor Support
population growth. Modules Bearings
250PE unit. Each unit is supplied as a 250PE unit
ease of transport.
Flexible modular
and further units supplied depending on layouts available
population requirements. to suit even the
toughest site
Primary and final settlement tanks can
Due be sized for the intended end population
or additional tanks can be supplied in the
conditions.
Flow Management
Process
Strapping
Options
Spring future and fed into the system.
Each of the units can be linked to create

B ran d
2018! a complete sewage treatment system.
The feed to each RBC can be controlled
N ew independently to give further flexibility.
S o l u ti o n The RBC unit measures 6.7 metres long
x 2.2 metres wide x 2.4 metres high. The
size of primary and final settlement tanks
will vary with each customer application
and site location.

Total flexibility with a Final


Settlement

unique modular RBC Tank

system

Primary
Settlement
01 02 03 04
Tank
Flow Management Process Sectional Media Modules Rotor Support Bearings Strapping/Lifting Options

The unique flow management The Biozone media within the The rotor assembly is supported The treatment plant can be
Primary Final process of the Klargester Klargester BioDisc® modular by a pillow block bearing at lifted from the side by forklift
Settlement Settlement commercial BioDisc® allows system, is built up in ‘wedge’ each end of the rotor shaft. truck. Forklift tubes are built
Tank Tank for complete flexibility of sections to make a two metre These are equipped with self into the steel construction
forward feed rate. Rotating diameter rotor assembly. lubricating grease cartridges to frame. The unit can also
buckets transfer untreated A complete wedge can be provide continual lubrication. be lifted at either end with
water through each of the removed from the rotor for Both of the bearings can the aid of extension forks.
BioZones, allowing for total maintenance or inspection be accessed by removing Alternatively, the unit can be
forward feed control. These without compromising the the individual covers for lifted with slings. Four lifting
are independently driven and overall rotor structure. This maintenance. It is not necessary brackets are attached to the
Primary Final
Settlement Settlement
allow the buckets to run at a ensures the rotor assembly can to remove the larger main frame and lifting shackles are
Tank Tank different speed to the rotor. stay in place, without the need covers, allowing for provided with each unit.
for removal. easier maintenance.

— —
20 21
Water Management Solutions

Klargester BioFicient® Available in our


Modular System

Commercial Sewage
Treatment Plant

The Klargester BioFicient Product Benefits


Performance and
Technical Specifications

commercial sewage ∙∙ Adaptable to specific consent


requirements including ‘Total Nitrogen’.
Compliance Model Reference 17H 23H 34H 38H 42H 47H 55H 67H 80H

treatment plant is ∙∙ Low head loss.


› Compliant with EN- A Overall Length (m) 7.4 9.3 7.4 8.1 8.9 9.7 11.2 13.5 15.8
12255 and EN12566-
designed with efficiency ∙∙ Minimal footprint area and visual 3 (up to 50 PE).
B Overall Width (m) 1.9 1.9 1.9 1.9 1.9 2.8 2.8 2.8 2.8

in mind. It offers reliable impact.


∙∙ Variable invert options (0.5 - 2.0 m).
› Designed and sized
C Height (m)

in accordance with
performance using tried
560mm Inlet / 860mm Outlet Invert* 2.28 2.28 3.02 3.02 3.02 3.02 3.02 3.02 3.02
∙∙ May be installed in trafficked areas British Water Code 1060mm Inlet / 1360mm Outlet Invert* 2.78 2.78 3.52 3.52 3.52 3.52 3.52 3.52 3.52
and tested technology to (subject to loading). of Practice Flows
and Loads but can 1560mm Inlet / 1860mm Outlet Invert* 3.28 3.28 4.02 4.02 4.02 4.02 4.02 4.02 4.02
∙∙ Low maintenance.
ensure consistently high ∙∙ Alarm protected.
be sized to suit local 2060mm Inlet / 2360mm Outlet Invert* 3.78 3.78 4.52 4.52 4.52 4.52 4.52 4.52 4.52

effluent quality. site conditions.


Diameter (m) 1.8 1.8 1.8 1.8 1.8 2.6 2.6 2.6 2.6

Volume (m )
3
17 23 34 38 42 47 55 67 80

Weight Approx (kg) 1200 1450 3000 3200 3400 3800 4200 4700 5400
Applications:
Inlet / Outlet Diameter (mm) 160 160 160 160 160 160 160 160 160
The BioFicient range is suitable for a range
of applications including: Maximum Flow (m /day) Models
3
8 11 15 20 25 30 40 50 60

Retention Time (hrs) 76 66 51 43 39 35 31 31 30



2.6m diameter
BioFicient is also
available as an
Public sector Leisure
alternative model.

Primary Settlement Final Settlement
Chamber Tank
Transport Hospitality

Campsites Offices
Biozone 1 Biozone 2

Multi-housing
developments

01 02 03 04
Primary Settlement Chamber Biozone 1 Biozone 2 Final Settlement Tank

This is the initial stage of treatment and simply involves The liquor enters the first stage of Biological treatment where Within the second stage of Biological treatment the second A natural by-product of biological treatment is humus sludge
the retention of coarse solids present in raw sewage and the active bacteria within the fluidized bed begin to break down fluidized bed continues to clean the liquor giving further BOD and this is separated for further treatment. The treated effluent
wastewater for subsequent gradual breakdown. BioFicient organic solids. The majority of BOD removal occurs here. reduction along with removal of nitrogen. is discharged via the outlet or to disinfection stage.
features two chambers to ensure efficient operation with
a flow balancing facility.
— —
22 23
Water Management Solutions

Choosing the Klargester Full Alarm


Range Available

Right Separator Full Retention


Separators
NSF RANGE

Kingspan has a specialist The chart below gives guidance to aid


selection of the appropriate type of fuel/
Full retention separators Each full retention separator design
includes the necessary volume Performance and
team who provide expert oil separator for use in surface water are used in high risk requirements for: Compliance
drainage systems which discharge into
technical assistance in rivers and soakaways. spillage areas such as ∙∙ Oil separation capacity. › Kingspan were
one of the first UK
selecting the appropriate fuel distribution depots, ∙∙ Oil storage volume.
∙∙ Silt storage capacity.
manufacturers to
have the required
Klargester Separator for vehicle workshops ∙∙ Coalescer (Class 1 units only). range certified to
your application. and scrap metal ∙∙ Automatic closure device.
EN 858-1 in the UK.
› The NSF number
recycling yards.  ur full retention separators treat the whole
O
of the specified flow.
denotes the flow at
which the separa-
tor operates.
› Approved by The
British Standards
Is there a risk of oil contaminating the Institute (BSI) in
drainage from the site?
relation to flow and
process perfor-
mance, meeting
YES YES YES YES NO effluent quality
requirements of
EN 858-1.
1
You must seek prior
Risk of infrequent permission from your local
light contamination sewer provider before you
and potential for
small spills only, e.g. Risk of regular decide which separator to Technical Specifications
car park contamination Very low risk of oil install and before you make
of surface water Drainage will also contamination, any discharge.
runoff with oil contain dissolved Fuel oils are e.g. roof water Storage Manhole Base Base to Min Standard
2
You must seek prior Drainage Area
and/or risk of larger oils, detergents or delivered to Model Flow Capacity (Ltrs) Length Diameter Cover Inlet Outlet Inlet Pipework
spills, e.g. degreasers such as and dispensed on permission from the relevant (m2) PPG-3
YES Reference (l/s) (mm) (mm) Dimensions Invert Invert Invert Diameter
vehicle vehicle wash water site, e.g. retail environmental body before (0.018) Silt Oil (mm) (mm) (mm) (mm) (mm)
maintenance area, and trade effluents, forecourts you decide which separator
goods vehicle e.g. industrial sites to install. Polyethylene Chamber Construction
Source control SuDS parking or vehicle
manoeuvring5
3
In this case, if it is considered
must be considered YES that there is a low risk of NSFP003 3 170 300 30 1700 1350 600 1410 1335 550 160
and incorporated pollution a source control
where suitable NSFP006 6 335 600 60 1700 1350 600 1410 1335 550 160
SuDS scheme may be
appropriate.
GRP Chamber Construction
Separator not
4
In certain circumstances,
required the sewer provider may NSFA010 10 555 1000 100 2610 1225 600 1050 1000 500 200
require a Class 1 separator
If not suitable YES YES YES for discharges to sewer NSFA015 15 835 1500 150 3910 1225 600 1050 1000 1000 200
to prevent explosive
atmospheres from being NSFA020 20 1115 2000 200 3200 2010 600 1810 1760 1000 315
generated.
NSFA030 30 1670 3000 300 3915 2010 600 1810 1760 1000 315
5
Drainage from higher
Trade effluents must Full retention risk areas such as vehicle
Full retention NSFA040 40 2225 4000 400 4640 2010 600 1810 1760 1000 315
be directed to the ‘forecourt’ Clean water should
separator with maintenance yards and
Bypass separator foul sewer1 separator with not be passed
alarm required goods vehicle parking areas NSFA050 50 2780 5000 500 5425 2010 600 1810 1760 1000 315
with alarm required alarm required through the
It may need to pass should be connected to
Class I if discharge separator unless
Class I if discharge through a separator Class I if discharge foul sewer in preference to NSFA065 65 3160 6500 650 6850 2010 600 1810 1760 1000 315
to surface water2 the size of the
to surface water2,3 before discharge to to surface water2 unit is increased surface water.
Class II if discharge sewer for removal of accordingly NSFA080 80 4445 8000 800 5744 2820 600 2500 2450 1000 315
Class II if discharge 6
In certain circumstances,
to foul sewer1 free oils to foul sewer1,4 a separator may be one of NSFA100 100 5560 10000 1000 6200 2820 600 2500 2450 1000 400
the devices used in the SuDS
scheme. Ask us for advice. NSFA125 125 6945 12500 1250 7365 2820 600 2500 2450 1000 450

NSFA150 150 8335 15000 1500 8675 2820 600 2500 2450 1000 525
Source control
The use of SuDS should be considered at all sites and they should be incorporated where suitable. SuDS should be NSFA175 175 9725 17500 1750 9975 2820 600 2500 2450 1000 525
SuDS can be used to polish the effluent from these separators before it enters the environment6 considered where
possible NSFA200 200 11110 20000 2000 11,280 2820 600 2500 2450 1000 600
— —
24 * Some units have more than one access shaft – diameter of largest shown. 25
Water Management Solutions

Klargester Concentration
Less Than
Klargester Expert Technical
Advice

Bypass Forecourt
Separators
5
MG/L
Separators
MONITORING
MONITORING OF
OF
NSB RANGE

Bypass separators are Forecourt separators


INTERCEPTORS /
Product Benefits Performance and Compliance Installation

INTERCEPTORS /
Performance & Compliance
used when it is considered ∙∙ Light and easy to install.
› Fully compliant and tested to are used to intercept ∙∙ Operation ensures that the flow cannot
exit the unit without first passing
∙∙ The unit should be installed on a suitable
concrete base slab and surrounded with
an acceptable risk to not ∙∙ Inclusive of silt storage volume. EN 858-1.
hydrocarbon pollutants
SEPARATORS
SEPARATORS
through the coalescer assembly. concrete or pea gravel backfill.
∙∙ Fitted inlet/outlet connectors. › Bypass separators are
provide full treatment ∙∙ Vent points within necks. tested by British standards such as petroleum and ∙∙ In normal operation, the forecourt
separator has sufficient capacity to
∙∙ If the separator is to be installed within a
trafficked area, then a suitable cover slab
for very high flows, such ∙∙ Oil alarm system available (required by institute (BSI).
oil to prevent their entry provide storage for separated pollutants must be designed to ensure that loads are
EN 858-1 and PPG3). › Certified flow and process
as where the risk of a ∙∙ Extension access shafts for deep inverts. performance assessing to the drainage system. within the main chamber, but is also
able to contain up to 7,600 litres of
not transmitted to the unit.
∙∙ The separator should be installed and
large spillage and heavy effluent qualities to the
DODO Typical
YOU POSE applications
ANANOIL CONTAMINATION RISK? pollutant arising from the spillage of a
∙∙ Maintenance from ground level.
requirements of EN 858-1. YOU POSE OIL CONTAMINATION RISK? vented in accordance with Health and
fuel delivery tanker compartment on the
rainfall occurring at ∙∙ GRP or polyethylene construction
› The unit is designed to treat include petrol filling petrol forecourt.
Safety Guidance Note HS(G)41 for

the same time is small.


(subject to model).
the ‘first flush’ - 10% of DODO
YOU STORE
YOU STORE
station OIL ONON
OIL
forecourts SITE?
and
filling stations.
SITE?∙∙ The separator has been designed with an ∙∙ Subject to Local Authority requirements.
peak flow. The calculated automatic closure device to ensure that oil
Typical applications drainage areas served by DODO
YOU
carHAVE
YOU A CAR
breaker
HAVE yards.
A CAR PARK
PARKFOR
FORMORE MORE
cannot THAN
exit the THAN 50
separator CARS?
50
in the CARS?
event of a
each separator are indicated
include surface DODO
YOU HAVE GOODS VEHICLE MOVEMENTS?
major spillage, consequently the separator
according to the formula
YOU HAVE GOODS VEHICLE MOVEMENTS?
should be emptied immediately.
carparks, roadways and given by PPG3 NSB =
0.0018A(m2).
lightly contaminated › Class I separators are YES THEN IT’SSpecifications
LIKELY YOU HAVE INTERCEPTORS ONON
SITE.
YES THEN
Technical IT’S LIKELY YOU HAVE INTERCEPTORS SITE.
commercial areas. designed to achieve a
concentration of less than
Access Base to Standard
5mg per litre. INTERCEPTORS
SeparatorTRAP
INTERCEPTORS OIL OIL
TRAP
Backfill AND
TotalOTHER HYDROCARBONS THAT HAVE ENTERED
AND OTHER
Drainage HYDROCARBONS THAT HAVE
Peak Flow Length Diameter Shaft ENTERED DRAINS
Base Inlet
DRAINS
Outlet
Standard Min Inlet
Pipework
Empty
Capacity Invert Fall Across Invert Weight
PREVENTINGClass Type
POLLUTION INCIDENTS.Area (m ) Rate (L/s) (mm) (mm) Diameter Invert Diameter
2

PREVENTING POLLUTION INCIDENTS.


(Ltrs)
(mm)
(mm)
(mm)
(mm) (mm)
(mm)
(kg)

I/II Concrete 10000 835 15 3915 2020 600 2180 2130 50 600 160 620
PPG3 STATES:
PPG3 STATES: INTERCEPTORS
INTERCEPTORS MUST HAVE
MUST A VISUAL
HAVE ANDAND
A VISUAL AUDIBLE WARNING
AUDIBLE WARNINGWHEN
WHENOIL OIL
I/II Concrete 10000 1115 20 3915 2020 600 2180 2130 50 600 200 620
REACHES 90%90%
REACHES STORAGE
STORAGE VOLUME
VOLUME
Technical Specifications

Peak Drainage Storage Access Base Base to Min Standard EUROPEAN STANDARD
EUROPEAN EN858-1-2:
STANDARD SUGGESTS
EN858-1-2: SEPARATORS
SUGGESTS SEPARATORS AREAREFITTED WITH
FITTED AN AN
WITH ALARM
ALARM
Model
Reference
Flow
(l/s)
Flow
Rate
Area(m2)
Based on UK
Capacity (Ltrs) Length
(mm)
Diameter
(mm)
Shaft
Diameter
Inlet
Invert
Outlet
Invert
Standard
Fall Across
Inlet
Invert
Pipework
Diameter
THAT
THAT FuelOF&EXCESSIVE
WARNS
WARNS Oil
OF LIQUID
EXCESSIVE LEVELS.
LIQUID
British European Standard EN 858-1 and
LEVELS.Environment Agency Pollution Prevention
Product Benefits

Separator Alarms
(mm)
(l/s) rainwater flow Silt Oil (mm) (mm) (mm) (mm) (mm)**
Guideline PPG3 requires that all separators ∙∙ Easily fitted to existing tanks.
Polyethylene Chamber Construction EXCESSIVE SILT,
EXCESSIVE OIL OIL
SILT, OR LIQUID LEVELS
OR LIQUID WILL
LEVELS PREVENT
WILLare to be THE
PREVENT fittedINTERCEPTOR
withINTERCEPTOR
THE FROM
an oil level alarm WORKING
FROM ∙∙ Excellent operational range.
WORKING
NSBP003 3 30 1670 300 45 1700 1350 600 1420 1320 100 500 160 EFFECTIVELY ALLOWING
EFFECTIVELY ALLOWINGOIL OIL
TO PASS THROUGH
TO PASS system.
ANDAND
THROUGH It should
POLLUTE be
POLLUTE installed and
WATERCOURSES. calibrated
WATERCOURSES. ∙∙ Visual and audible alarm.
by a suitably qualified technician so that
NSBP004 4.5 45 2500 450 60 1700 1350 600 1420 1320 100 500 160
it will respond to an alarm condition when ∙∙ Additional telemetry option.
NSBP006 6 60 3335 600 90 1700 1350 600 1420 1320 100 500 160 the separator requires emptying.
GRP Chamber Construction
ALARM INDICATES
ALARM INDICATES
NSBE010 10 100 5560 1000 150 2069 1220 750 1450 1350 100 700 315
HIGHHIGH
OIL LEVEL
OIL LEVEL
NSBE015 15 150 8335 1500 225 2947 1220 750 1450 1350 100 700 315
NSBE020 20 200 11111 2000 300 3893 1220 750 1450 1350 100 700 375
NSBE025 25 250 13890 2500 375 3575 1420 750 1680 1580 100 700 375
NSBE030 30 300 16670 3000 450 4265 1420 750 1680 1580 100 700 450
NSBE040 40 400 22222 4000 600 3230 1920 600 2185 2035 150 1000 500
NSBE050 50 500 27778 5000 750 3960 1920 600 2185 2035 150 1000 600
NSBE075 75 750 41667 7500 1125 5841 1920 600 2235 2035 200 950 675
NSBE100 100 1000 55556 10000 1500 7661 1920 600 2235 2035 200 950 750
NSBE125 125 1250 69444 12500 1875 9548 1920 600 2235 2035 200 950 750
ALARM INDICATES
ALARM INDICATES
* Some units have more than one access shaft – diameter of largest shown | ** Larger pipework available on request. HIGHHIGH
SILT SILT
LEVELLEVEL
— —
26 27
HOW THEY
HOW WORK
THEY WORK
DID YOU KNOW:
Water Management Solutions

Klargester Grease Easy to Install


Klargester Washdown
Separators and Silt Units

Klargester grease Key Standard Features How it works


Klargester washdown How it works Applications

separators are an ∙∙ Greatly reduces drain blockages, for


maximum operational efficiency.
Grease separators allow fats and
grease to naturally separate out from
and silt units can be As contaminated water passes through
the separation chamber, it is retained
These units can be used to serve vehicle
washdown areas and car wash facilities,
effective and hygienic ∙∙ Helps improve performance of septic water, allowing their removal prior to used in areas such as long enough to allow solids to sink to although it should be noted that the
method of separating tanks and field drains and achieve best
results.
the wastewater reaching the drainage
system. The separator should be installed
car wash and other the bottom of the unit. Our design uses
a maximum of six minutes hydraulic
prime function of such separators is for
the removal of silt. Typical locations using
fat and grease from ∙∙ Prevents contamination of small sewage
close to the source of contamination cleaning facilities that retention time, at the flow rate given. The wash down separators are: car wash, tool
before any foul waste can enter the separator water is then able to discharge hire depots, truck cleansing, construction
wastewater flow. Grease treatment plants, reducing risk of
breakdown.
drainage flow and to suit the expected discharge directly into safely. compounds cleansing points.
separators are designed ∙∙ Protects mains drainage system from
liquid temperature.
a foul drain, which The nature of the silt varies depending on Locations requiring silt separators are:
for restaurants, hotels, grease blockages. feeds to a municipal either the ground or surface receiving the
flow. These aspects should be considered
highly silted sites where NS separators are
used, i.e. works constructions sites and
public houses, canteens treatment facility. when selecting the size of the unit in temporary work compounds.
relation to the flow being treated.
and similar applications. If emulsifiers are present, the discharge
Our washdown and silt separators are
manufactured from durable, rot and
must not be allowed to enter an NS unit. corrosion proof glass reinforced polyester
combining light weight with outstanding
strength. The units are delivered complete
with inlet and outlet pipework as well as
factory fitted access shafts to ensure
quick and easy installation on site.

Grease Range Sizing Table

Meals Per Day Standard Meal Fast Food Fine Cuisine


40 NSG01 NSG01 NSG02
60 NSG02 NSG02 NSG02
80 NSG02 NSG02 NSG04
100 NSG02 NSG04 NSG04
200 NSG04 NSG06 NSG09
300 NSG06 NSG09 NSG14 Technical Specifications
500 NSG09 NSG14 NSG18
700 NSG14 NSG18 NSG24 Max. Access Base Base To Stan- Standard
Total Min Inlet Approx.
900 NSG18 NSG24 — Max.rec. Flow Length Diameter Shaft Di- Inlet Outlet dard Fall Pipework
Model Ref Capacity Invert Empty
1,300 NSG24 — — Silt (Ltrs) Rate (mm) (mm) ameter Invert Invert Across Diameter
(Ltrs) (mm) (Kg)
(L/s) (mm) (mm) (mm) (mm) (mm)

W1/010 1000 500 3 1123 1225 460 1150 1100 50 500 160 60
Technical Specifications
W1/020 2000 1000 5 2074 1225 460 1150 1100 50 500 160 120

Dimensions (mm) Flow Rates Approx Weight (Kg) Fall Across W1/030 3000 1500 8 2952 1225 460 1150 1100 50 500 160 150
Model Reference Shipping Height (mm) Capacity (L)
Length Width (L/s) Empty Full The Unit (mm) W1/040 4000 2000 11 3898 1225 460 1150 1100 50 500 160 180
NSG01 1320 750 1 1100 500 70 570 75 W1/060 6000 3000 16 4530 1440 600 1360 1310 50 500 160 320
NSG02 1620 1100 2 1175 1000 90 1090 75
W1/080 8000 4000 22 3200 2020 600 2005 1955 50 500 160 585
NSG04 2072 1224 4 1570 2000 120 1860 70
NSG06 3018 1224 6 1570 3000 160 2820 70 W1/100 10000 5000 27 3915 2020 600 2005 1955 50 500 160 680
NSG09 3895 1224 9 1570 4000 190 3760 70 W1/120 12000 6000 33 4640 2020 600 2005 1955 50 500 160 770
NSG14 4418 1422 14 1745 6000 215 5535 70
W1/150 15000 7500 41 5435 2075 600 1940 1890 50 500 160 965
NSG18 3231 1917 18 2120 8000 300 7162 70
NSG24 4386 1917 24 2120 11000 380 9885 70 W1/190 19000 9500 52 6865 2075 600 1940 1890 50 500 160 1200
— —
28 29
Water Management Solutions

Klargester Compact Klargester Domestic


Pumping Stations and Domestic+
Pumping Stations

Our proven range of Quick to install and easy to maintain,


Klargester pump stations are the ideal
Product Benefits
Our domestic pumping Quick and simple to install, they require
minimal maintenance. They come
Product Benefits

compact pump stations solution for outbuildings and extensions, ∙∙ Non-return valves and outlet pipe
compression coupling as standard.
stations are ideal for with single or twin pumps, and are ∙∙ Made with super-tough, low
maintenance GRP and high quality
cellars, pool houses and external WCs. suitable for sewage, surface water and
can be used for effluent They can be used for effluent or ∙∙ 3 pump options; effluent low head, homes or properties effluent. Appropriate for 24 hour storage polyethylene for guaranteed durability.
or sewage and are easy sewage, depending on the pump,
distance and height.
effluent high head and sewage vortex. with up to 13 people. requirements. ∙∙ Comes with options of remote
monitoring systems.
to install. ∙∙ Service and maintenance plans available
to prolong the life of the pump systems. ∙∙ Designed with easy access features for
∙∙ Complete pre-fabricated solution ready maintenance.
for installation. ∙∙ Choose from either 110mm or 160mm
∙∙ Fully automatic. inlet connections.
∙∙ Lockable covers for optimum security.
∙∙ Quick connection outlet couplings.

Technical Specifications Technical Specifications - Domestic Technical Specifications - Domestic+

Chamber Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type Capacity Tank Control Capacity Tank Control
Chamber Size Alarm Pump Type Chamber Size Alarm Pump Type
(Ltrs) Material Panel (Ltrs) Material Panel
610 x 700 200 GRP N/A Optional Single
900 x 2580 1,600 GRP Included Optional Single/Twin 1000 x 2000 1450 Polyethylene Included Standard Single/Twin
560 x 1,650 400 GRP N/A Optional Single
900 x 2080 1,250 GRP Included Optional Single/Twin 1000 x 2500 2200 Polyethylene Included Standard Single/Twin

Selecting the Correct


Pumping Station System
All Klargester pumping They are also designed in line with
Building Regulations for Foul Drainage.
The key factors to size your system are
as follows:
Applications

stations are suitable for Your system size will depend on the
∙∙ Application: domestic, residential or
Suitable for a wide range of applications,
the compact and domestic range of
type of waste you need to manage,
pumping wastewater your distance from the sewer and the commercial. Klargester Pumping Stations are suitable
effluent and sewage difference in levels. ∙∙ Material application: sewage, effluent or
surface water.
for the following types of applications
and many more:
in accordance with For expert advice, to help you select
the correct system, please contact our ∙∙ Inlet depth (below ground level).
BS 756-2.
Small Commercial Roof and
specialist team on: ∙∙ Pumping distance and lift. Offices Surface Water

NI: 028 3026 6799 | ROI: 048 3026 6799 ∙∙ Electrical supply.
or email: water-IE@kingspan.com Domestic Remote
Properties Classrooms

— —
30 31
Water Management Solutions

Klargester Vertical Klargester Horizontal


Pumping Stations Pumping Stations

Our Klargester Tanks and pumps come in a range of


sizes and dimensions and have a 24-hour
Product Benefits
If power supplies fail, Product Benefits Commercial pump systems are made
from GRP. It is designed as a single piece
commercial pumping storage capacity for foul waste to comply ∙∙ High-level alarm. Klargester commercial ∙∙ Single-tank installation up to 79m3 chamber with two separate sections,
(multiple tank systems available).
systems are ideal for
with Building Regulations. A wide range
of surface water pumps are available for
∙∙ Internal lifting chains and guide rails
(as specified).
pumping stations ∙∙ Multiple valve chamber location and
one for normal operation and one for
emergency storage.
developments and such applications from small roof run offs, ∙∙ Wide range of pump options including respond instantly, invert options.

premises where drainage


to large SUDS schemes, delivering up to
70 litres/second.
macerators/vortex. commercial responds ∙∙ Weir screen features innovative
removable filters, so there’s no
by gravity is not an Klargester commercial pumping stations
∙∙ Range of emergency overflow tanks,
if required.
instantly, separating need to access the chamber during

option.
are made from robust GRP. They are ∙∙ Inlet connection sizes to suit site. liquids and solids into a maintenance.
designed as a single-piece chamber, ready
for installation with no man-entry required. ∙∙ Various invert depths and positions. separate chamber and ∙∙ High-level alarm.
∙∙ Totally sealed system.
∙∙ GRP chambers with internal pipework in
plastic, galvanised or cast iron.
storing waste for up to 24 ∙∙ One-piece tank chamber for easy
∙∙ Optional kiosks with warning beacons hours. Once power is installation.
and optional telemetry systems. restored, the pumps will ∙∙ Minimal on-site assembly.
∙∙ Less cranage and shallower excavation
∙∙ Service and maintenance plans available
to prolong the life of the pump systems.
work normally again than concrete pumping stations.
without further ∙∙ On-site Health & Safety issues are

maintenance. minimised – no requirement for


personnel to enter the tank.

Technical Specifications Technical Specifications

Tank Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type
Vertical Tank Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type
2,600 Diameter 18000-79000 GRP Included Standard Single/Twin
1250 Diameter Up to 4,800 GRP Included Standard Single/Twin

Klargester Adoptable and High


1800 Diameter Up to 10,000 GRP Included Standard Single/Twin

2600 Diameter Up to 22,000 GRP Included Standard Single/Twin

Specification Pump Systems


Applications
The adoptable and high For expert advice, please contact our
specialist team on 028 3026 6799 (NI),
Designed for easy installation and available
in many sizes to meet an extensive range of
specification pump 048 3026 6799 (ROI).

customer requirements, the Klargester range stations are designed Manufactured as a ready to install
pre-fabricated unit for Type 1 and Type 2
of Horizontal and Vertical Pumping Stations
are typically used in applications including: to NI Water Standard installations for up to 20 dwellings.
Specification (May Product Benefits
2016) and meet the ∙∙ GRP single piece wet well delivered to
site ready to install.
Housing Caravan/ Surface Water
requirements of ∙∙ Pre-fitted internal pipework, pump
Developments Schools Camping Sites Run-off ‘Sewers for Adoption 7th guide rails and overflow filters.

Edition’ and the ‘Water ∙∙ Approved control panel and kiosk.


∙∙ All necessary drawings supplied.
Large Commercial Hotels & Nursing Homes


Developments Restaurants Industry Standard’ (WIS). ∙∙ NI Water specified Controls and Hygiene —
32 unit. 33
Water Management Solutions

Klargester Gamma Home and


Garden

Fully Integrated Rainwater


Harvesting System

The Klargester Gamma With a technologically advanced finish,


Gamma is suitable for both self build
rainwater harvesting projects and residential developments.
3
1 Water main
4
system is designed as It works by taking the rain from your roof 2 Storage tank
gutters, filtering out leaves and debris and 3 Header tank (optional extra)
an intelligent rainwater storing the water in an underground tank.
10 4 Pressure Vessel (not supplied)
harvesting system, tailor Manufactured from tough polyethylene, 5 In-line filter 120 microns
made for your home. the tank is robust and lightweight, which
makes it easy to handle and install. Its
6 Internal rainwater filter
1
fuss free design offers high functionality, 7 Grundfos Intelligent Pump—
making it the perfect choice for your SBA 3-23M
home or garden. 5 8 Adjustable tank neck
Typical Applications Include: 9
9 External tap (not supplied)
Automatic in operation, the Gamma
rainwater harvesting system offers 10 Roof rainwater feed
powerful features for complete peace of 11 Filtered rainwater feed
mind in your home. The intelligent system
ensures an automatic supply of harvested Reduces Water Regulations
Consumption Compliant
WC Garden and rainwater for your home and garden.
Flushing Landscape Watering For home and garden use, the Gamma is 11

available in capacities between 2,350-


4,600 litres.
8

6 Offers Fast Advisory


Domestic Vehicle Payback Consultants
Laundry Washing

2 7

Technical Specifications Features and Benefits Optional Extra - Header Tank

∙∙ Can reduce water consumption in When ordering your system, to make the
Tank Dimensions
domestic applications by up to 50%. Gravity System complete you will require
Model Standard Standard
Reference Standard ∙∙ Easy to install and simple to maintain. a header tank. Klargester offers a header
Capacity Overall Outlet Length Width
Height
Inlet Invert*
Invert* tank with weir, ballcock and float valve
∙∙ ‘Fit and Forget’ system, ensuring A
which allows the switch over to mains, the
Gravity System an automatic supply of harvested
01 The Gravity System
weir provides the mandatory air gap. C
rainwater.
GRW080 2,350 Ltrs 1,770mm 720mm 750mm 3,000mm 1,180mm The Gravity System uses B
an elevated header tank ∙∙ Shallow Dig—the Gamma is designed
GRW110 3,100 Ltrs 2,260mm 720mm 750mm 2,480mm 1,130mm to store filtered water with easy, affordable installation A Mains Input
after the main tank. B Rainwater Input E
in mind. D
GRW160 4,600 Ltrs 2,260mm 720mm 750mm 3,360mm 1,215mm C Water Regulations Compliant
∙∙ Pea shingle backfill available—no costly
Mandatory Air Gap F
Direct System 02 The Direct System excavation and soil disposal necessary
D Overflow Point
(dependent upon site conditions).
GRW080 2,350 Ltrs 1,768mm 720mm 750mm 3,000mm 1,180mm The Direct System pumps E Rainwater Level Control
water from the main ∙∙ Fully compliant—Gamma is tested F Mains Level Control
GRW110 3,100 Ltrs 2,260mm 720mm 750mm 2,480mm 1,130mm storage tank and is used in accordance with BS 8515:2009.
where a header tank is
impractical.
standards.
GRW160 4,600 Ltrs 2,260mm 720mm 750mm 3,360mm 1,215mm

* Includes tank neck - adjustable to suit required invert.


— —
34 35
Water Management Solutions

Klargester Aquabank® Klargester RainTrap® Fully


Easy to
Install
Compliant

Rainwater Harvesting Rainwater Storage and


Range Delivery System

Overview Aquabank is suitable for single residential Benefits of Installing Klargester Overview
applications. It uses cohesive design with Domestic Rainwater Systems 1. Pump power switch
The Klargester Aquabank rainwater the system controlled by a pump, with An economical rainwater harvesting
harvesting system is designed with system designed to make garden 2. Pumped water to required
options for either direct or gravity fed
simplicity in mind. watering simple. The Klargester application, e.g. garden hose,
applications. It’s a highly intuitive system
power washer

50
SAVE UP TO
– easy to use with no need for a control on water consumption in domestic RainTrap system comprises of a filter, an
% applications with Klargester underground storage tank and a pump. 3. Rainwater inlet (110mm)
panel, display panel or depth sensor.
Applications: Rainwater Harvesting solutions Rainwater runs down the roof and into 4. Submersible pump
Manufactured from strong GRP material, the guttering and downpipes in the
Aquabank is a complete ‘kit in a box’ – 5. Wastewater / overflow outlet
normal way before passing through the
easy to install and the smart choice for (110mm)
The system that pays for itself — filter, which removes any leaves or debris.
your home’s rainwater harvesting needs. money saved through reduced Rainwater is stored in the underground 1 6. Leaf filter
For home and garden use, the Aquabank water bills means aquabank can tank from which it is pumped at a constant 7. Safety manhole lid
Vehicle Washing Garden Watering is available in capacities between 1,000 pay back its purchase costs pressure to an outside tap as required.
and 6,000 litres. 2
The RainTrap has many advantages over
— traditional garden waterbutts. In addition
Features and Benefits Assists planning application — to being able to store far larger quantities
Authorities increasingly expect of water, it removes the need to carry
WC Flushing Domestic Laundry ∙∙ Easy to install. applications to Demonstrate water around and does not flood when
∙∙ Simplified system designed for Sustainable Drainage (SuDS) full, since the excess water exits via a
rapid installation. soakaway or surface water drain.
∙∙ Quick start set up procedure.
∙∙ ‘Kit in a box’ set of key components. 7
Features and Benefits
3
∙∙ Easy conversion to gravity system with
header tank. ∙∙ Easy to install.
∙∙ Minimal energy use in operation. ∙∙ Inexpensive. 6
∙∙ Simple on / off operation. 5
∙∙ Fully compliant - designed in accordance
with BS EN8515. ∙∙ Suitable for existing and new homes.
How it works ∙∙ Available in sizes from 1,000 — 6,000 litres.
∙∙ Automatic rainwater diversion when
tank reaches full capacity.
∙∙ Internal leaf filter.
∙∙ Designed and manufactured in the UK.

01 02 03
4

Rainwater is stored in underground tank Rainwater is pumped at a constant Water is pumped to a garden sprinkler or
pressure to an elevated header tank hose as required Technical Specifications

Model Capacity (Ltrs) Standard Overall Height Standard Inlet Invert Standard Outlet Invert Diameter / Width Length Model Reference Capacity (Ltrs) Diameter (mm) Height Base to Outlet (mm)
Gravity & Direct System RT2800 2,800 2,070 1,540
AQB010 1,000 2,140mm 500-800mm 530-830mm 1,225mm 1,125mm
RT3800 3,800 2,070 1,760
AQB028 2,800 2,582mm 500-1000mm 530-1030mm 2,070mm —
RT4600 4,600 2,080 1,925
AQB038 3,800 2,811mm 500-1000mm 530-1030mm 2,070mm —

AQB046 4,600 2,961mm 500-1000mm 530-1030mm 2,070mm —

AQB060 6,000 2,365mm 500-800mm 530-830mm 1,424mm 4,275mm


— —
36 37
Water Management Solutions

Klargester Commercial After Sales


Below Ground Rainwater Service and
Harvesting System Support

The Klargester We recognise the Together we are working to provide first


class service across a range of sectors,
∙∙ First class technical engineering
expertise across a range of off-mains
commercial range is a importance of after including domestic, commercial, industrial, sewage and wastewater applications.
leisure, hospitality and many more.
fully integrated, intelligent sales service and support ∙∙ Day to day technical support.
With expertise across the Klargester range ∙∙ 24 hour breakdown repair.
rainwater harvesting and are proud of our of wastewater and drainage solutions, ∙∙ Preventative maintenance plans.
solution suitable for nationwide Kingspan pumping stations, separators and rainwater
harvesting, our dedicated support network
∙∙ Installation and commissioning.
such applications as Service network, which offers the following offers the after sales ∙∙ Asset monitoring.
service and support you would expect from
commercial vehicle comprises our Kingspan a global organisation.
∙∙ Consultancy and advice.

washdown areas, garden in-house Service team


centres and and Accredited Installer
golf courses. network in support of the
Klargester Product Range.

The commercial range provides a secure Large installations are carefully sized and Features
solution for any size of building project selected, taking into consideration the
from 6,000 litres up to 79,000 litres following factors: ∙∙ Capacities from 6,000 to 79,000 litres
within a single tank. To speak with us about any aspect of
of water in a single tank. For larger
∙∙ Roof water yield. installation, commissioning or service
capacities, multiple tanks may be ∙∙ Multiple tanks can be joined to cater for
∙∙ Projected water consumption. simply contact:
connected together to meet storage larger volumes.
requirements. ∙∙ Groundwork criteria (prevailing water ∙∙ Can be installed under trafficked areas
table, soil conditions, requirements or Tel: 0333 240 6868
It is available as either a gravity or (with reinforced concrete support).
direct system, depending on specific site
traffic access).
∙∙ Complete packaged units delivered
Email: water-IE@kingspan.com
requirements. ∙∙ Suitable filters and pumps to match directly to site.
system specifications, ensuring the
kingspan.ie/klargester
water is kept at an optimum level of
clarity and supply pressure).

Technical Specifications

Single Pump Model Reference Twin Pump Model Reference Capacity (Ltrs) Diameter(m)
ENV0200SKSW ENV0200TKSW 6000 1.4
ENV0275SKSW ENV0275TKSW 8000 1.8
ENV0350SKSW ENV0350TKSW 10000 1.8
ENV0485SKSW ENV0485TKSW 14000 1.8
ENV0625SKSW ENV0625TKSW 18000 2.6
ENV0765SKSW ENV0765TKSW 22000 2.6
ENV0900SKSW ENV0900TKSW 26000 2.6
ENV1040SKSW ENV1040TKSW 30000 2.6
ENV1320SKSW ENV1320TKSW 38000 2.6
ENV1460SKSW ENV1460TKSW 42000 2.6
ENV1735SKSW ENV1735TKSW 50000 2.6
ENV2050SKSW ENV2050TKSW 59000 2.6
ENV2325SKSW ENV2325TKSW 67000 2.6
ENV2745SKSW ENV2745TKSW 79000 2.6
— —
38 39
UK Germany
Kingspan Environmental Ltd Kingspan Environmental GmbH
College Road North, Siemensstr. 12a, D-63263
Aston Clinton, Aylesbury, Neu-Isenburg, Deutschland
Buckinghamshire, HP22 5EW T: +49 (0) 6102 3686700
T: +44 (0) 1296 633000 E: wasser@kingspan.com
F: +44 (0) 1296 633001 W: kingspan.de/wasser
E: water@kingspan.com
W: kingspan.co.uk/klargester Australia
Kingspan Environmental Pty Ltd
Ireland 8 Bessemer St, Blacktown
Kingspan Environmental Ltd Sydney, NSW 2148
Unit 1a, Derryboy Road T: +61 (0) 2 8889 5400
Carnbane Business Park Toll Free: (within Australia)
Newry, BT35 6QH 1300 736 562
T: +44 (0) 28 3026 6799 E: sales.au@kingspan.com
E: water-IE@kingspan.com W: kingspan.com.au/water
W: kingspan.ie/klargester
Poland
Norway Kingspan Environmental Sp. z o.o.
Kingspan Miljø AS ul. Topolowa 5
Skiveien 42, 1410 Kolbotn, 62-090 Rokietnica
Norway Polska
T: +47 22 02 19 20 T: +48 61 660 94 71
E: avlopslosninger@kingspan.com E: woda@kingspan.com
W: kingspanklargester.com/no W: kingspan.pl/woda

We take every care to ensure that the information in this document is accurate at the point of publication, but
with continuous product development, details are subject to alteration without notice.
Kingspan | Klargester Product Guide – English – January 2018

You might also like