Klargester
Product Guide
The Klargester range of fully integrated
wastewater management, surface water
and rainwater harvesting solutions
kingspan.ie/klargester
Water Management Solutions
Global Reach
Italy
France
Norway
UK & Ireland
Sweden
Spain Germany
USA
Poland
Turkey
Middle East
Asia—South East
Locally Nationwide
Accessible Distribution
Brisbane
Sydney
South America
Melbourne
— —
2 3
Water Management Solutions
Regional
Installations
Thanet Earth UK
Elite Office Furniture UK
Everton FC (Training Ground) UK
Dundee Kent, England Goole, England Liverpool, England
Four vertical pumping stations to aid Surface water separators, foul, effluent Modular BioFicient commercial system
water management for a complex and crude sewage pump stations, grease including fuel/oil separators for a complete
greenhouse development. trap and BioFicient commercial system. wastewater management solution.
Clifford
Co. Fermanagh
Liverpool
London
Kent
Barn Conversion UK
Supermarket Car park UK
Wing, England London, England
Domestic Sewage
Treatment Plant
The Klargester domestic Product Benefits The Rotational Biological Contactor Technical Specifications
Final Settlement
Small Offices Light Industrial Tank
Premises Primary
Settlement Tank
Farms
01 02 03 04
Primary Settlement Tank First Stage Biological Treatment Second Stage Biological Treatment Final Settlement Tank
Wastewater and sewage flows into the primary settlement tank The liquor and fine solids then flow into the Biological Treatment The liquor is then fed forward at a controlled rate into Biological The clean liquid passes into the final settlement tank where it
where the large solids are retained for future removal. Zone 1 where the first stage of treatment occurs. Treatment Zone 2 for further cleaning. can be discharged to ground or watercourse.
— —
6 7
Water Management Solutions
Domestic Sewage
Treatment Plant
treatment plant provides ∙∙ Shallow Dig. Compliance Model Reference BioFicient 1 BioFicient 2 BioFicient 3 BioFicient 4 BioFicient 5 BioFicient 6
uses the latest treatment *BioFicient IPS models only (Outlet Depth 320mm) | **BioFicient 4, 5, 6 has two shafts.
technology to deliver
a high level of water
discharge quality.
Applications
BioZone
Single & Barn
Multiple Homes Conversions
Primary
Settlement Tank
Raw sewage gravitates to the unit where it is received in the primary settlement zone. Solids are broken down by air agitated media in the Biozone. Fine solids are settled out in the final
Farms
Here, gross solids and other social debris settle to the bottom of the tank where they Media and liquid circulation in the Biozone is achieved through settlement tank. The Final effluent is
remain until the tank requires desludging. Settled sewage is displaced from primary the use of a compressor and diffuser, which introduces fresh air discharged via either gravity outlet or
zone and enters the first of two sequential moving aerated media reactors. into each compartment. The liquor is constantly recirculated and IPS (Integral Pump System) chamber.
contacts the moving media. As it does so, it is purified by the With regulatory approval, it is suitable
micro organisms growing on the surface of the media and within for discharge to a watercourse or
the moving liquor. Excess growth of biomass is shed as solid drainage field.
particles into the liquor.
— —
8 9
Water Management Solutions
Domestic Sewage
Treatment Plant
The Klargester BioFicient+ Product Benefits The Klargester BioFicient+ unit is a new
generation of package sewage treatment
Technical Specifications
Performance and
sewage treatment plant ∙∙ Shallow dig with minimal visual impact. plant developed to treat domestic Model BioFicient 1+ BioFicient 2+ Compliance
∙∙ Easy and affordable installation. sewage waste. With two sizes available,
provides a reliable and ∙∙ Low power consumption. it offers a simple and compact system
Population Equivalent 6 10 › Fully marked in
line with the CPR
effective solution, suitable ∙∙ Modern design allows for desludging
comprising three treatment zones within
a ‘uni-tank’ design.
Overall Diameter (mm) 1,690 2,010
2013.
for homes with up to 10 through the wide neck.
The moving aerated media process
Length (mm) 2,480 3,189
› Fully compliant,
∙∙ BioFicient+ conforms with NIEA 95% BOD tested and
people and is S.R.66:2015
Depth (mm) 2,355 2,785
removal. used is a compact development of the approved to IS
traditional biological process and provides Inlet Invert (mm)* 575-1,500 700-1,500
compliant. a more effective and complete means of Outlet Invert (mm) 675-1,600 800-1600
EN12566 / S.R.66:
2015.
sewage treatment.
Material MDPE MDPE › Conforms with
NIEA 95% BOD
Blower Ratings 50W 95W
removal.
Cover sizes 700 700
Applications
Note: Models BioFicient1+ and BioFicient 2+ available to NI Market only. Optional inlet depth down to 1800mm
The Klargester domestic BioFicient+ *BioFicient IPS models only (Outlet Depth 320mm)
range is suitable for a variety of
applications, including:
Primary
Farms Settlement Tank
01 02 03 04
Wastewater and sewage flows into the primary settlement Solids are broken down by air agitated media in the Biozone. The final settlement tank is where fine solids form to sludge. Final effluent is discharged from the final settlement tank.
tank where solids are settled out and retained. Settled sewage Media and liquid circulation in the Biozone is achieved through At preset intervals, portions of the sludge and liquor are returned With regulator approval, it is suitable for discharge to a
is displaced from primary zone and enters the aerated media the use of a compressor and diffuser, which introduces fresh air to the primary tank for additional treatment. The primary and watercourse or drainage field.
reactor (Biozone). into each compartment. The liquor is constantly recirculated final settlement zones should be emptied of sludge every 12
and contacts the moving media and as it does so, it is purified months.
by the micro organisms growing on the surface of the media
and within the moving liquor. Excess growth of biomass is shed
as solid particles into the liquor.
— —
10 11
Water Management Solutions
Is a gravity
Site Assessment connection possible?
YES Connect to Sewer
How it works
NO
Outlet from Outlet from
treatment plant treatment plant
800
Vp Vp Do you have sufficient land Septic Tank or
800 YES
< 12 or >100 12 - 100 space for drainage fluid? Sewage Treatment Plant
NO
— —
12 13
Water Management Solutions
Klargester Klargester
Alpha Septic Gamma Septic
Tank Tank
Klargester Alpha tanks Basic septic tanks only retain solids and
discharge effluent of low quality. The Performance & The Klargester Gamma Manufactured from tough polyethylene,
the tank is robust and lightweight which Performance &
provide a reliable and installation will not contaminate any Compliance tank is an affordable makes it easy to handle and install. Compliance
ditch, stream or other watercourse.
economic solution for However, many local authorities prohibit › Performance tested solution for domestic Due to its design features, the Gamma ›9
9.97% efficiency
to BS EN 12566 Part tank is the perfect solution where a rating.
homes not connected their use. In all instances a sewage
treatment system should be considered 1 requirements. applications with an shallow dig installation is required, › BS EN 12566 Part 1
to mains drainage. as a first option. › Fully marked in efficiency rating of 99.97% reducing installation time and costs. approved.
line with the CPR —
Septic tanks may be installed, subject to 2013. – an industry benchmark. Product Benefits
› Fully marked in
line with the CPR
consent, in applications where:
2013.
∙∙ Soil is of suitable porosity. ∙∙ Manufactured from robust, impact
› Building control
resistant, high quality polyethylene.
∙∙ Installation complies with Building and S.R.66:2015
Regulations (Approved Document H). ∙∙ Strong, easy to move and simple to install. compliant.
∙∙ The installation will not contaminate any ∙∙ Lower excavation costs, less soil disposal
ditch, stream or other watercourse. and less backfill material.
∙∙ The plot is large enough. ∙∙ Wide neck for easy access for annual
desludging.
—
∙∙ Trimmable neck to suit site.
Product Benefits
Single and
Multiple Homes Churches Farms
Temporary
Golf Course Work Offices and
Toilet Facilities Mobile Homes Welfare Facilities
No. People Overall Diameter Standard Inlet Standard Outlet No. People (150 Width Length Height Standard Inlet Standard Outlet Depth
Model Reference Volume (L) Height (mm) Model Reference Volume (L)
(150 Ltrs/head/day) (mm) Invert (mm) Invert (mm) Ltrs/head/day) (mm) (mm) (mm) Invert (mm) Invert (mm) (mm)
STS02810 2800 5 2075 2599/3099 1000/1500 1050/1550 GST028 2800 5 1130 2480 1755 - 2255 550-1050 550-1050 2255
STS03810 3800 12 2075 2810/3310 1000/1500 1050/1550 GST035 3500 10 1180 3000 1755 - 2255 550-1050 550-1050 2255
STS04610 4600 17 2084 2984/3484 1000/1500 1050/1550 GST040 4000 13 1215 3360 1755 - 2255 550-1050 550-1050 2255
— —
14 15
Water Management Solutions
shallow dig septic tank is ∙∙ Made from GRP - strong and durable for Compliance below ground storage consistent high performance, even in the ∙∙ Easy to install with minimal on site
ultimate reliability. installation time.
designed to reduce both ∙∙ Robust and simple to install, reducing on
› Certified
to BS EN tanks provide a reliable
toughest environmental conditions.
∙∙ Designed in accordance with BS6297,
installation time and cost. site installation time.
12566 Part 1
› Fully marked in
solution for the collection ensuring that you meet all building
regulations.
The range is available in ∙∙ Lower excavation costs, less soil disposal
and less backfill material required.
line with the CPR and retention of sewage ∙∙ High level alarm available for complete
various sizes suitable for ∙∙ Light, watertight and chemically
2013.
(cesspool), surface peace of mind.
Applications
Single and
Multiple Homes Churches Farms
Temporary
Golf Course Work Offices and
Toilet Facilities Mobile Homes Welfare Facilities
No. People Overall Standard Inlet Standard Outlet Nominal Litres Capacity (Gallons) Length (mm) Diameter (mm)
Model Reference Volume (L) Length (mm) Depth (mm)
(150 Ltrs/head/day) Diameter (mm) Invert (mm) Invert (mm) 18,000 3960 4317 2620
22,000 4889 5073 2620
STH028 2800 5 1225 2955 500 530 1627/1587*
26,000 5720 5837 2620
STH038 3800 12 1225 3895 500 530 1617/1577* 34,000 7480 7376 2620
STH057 5700 24 1425 4275 500 530 1826/1786* 46,000 10,120 9684 2620
54,000 11,880 11,222 2620
STH071 7150 34 1920 3225 500 550 2290
59,000 12,968 11,991 2620
STH091 9150 47 1920 3960 500 550 2290 63,000 13,860 12,760 2620
71,000 15,620 14,295 2620
79,000 17,380 15,833 2620
*110mm diameter pipework/ 160mm diameter pipework
— —
16 17
Water Management Solutions
Commercial Sewage
Treatment Plant
Water approved.
range (up to 300PE),
Maximum Daily Flow (m3) 5 7 10 14 15 20 25 30 45 60
treatment.
› Designed
for applications Ø/Width (mm) 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
offers low running ∙∙ Low running costs.
∙∙ Noise free.
selected in compliance with Length (mm) 3340 3340 4345 5235 7755 7755 7755 7755 10420 13100
British Water Code of Practice
costs due to its unique ∙∙ Fully removable lid for easy desludging. Flows and Loads. Inlet Invert depth (mm) 600/1100 600/1100 600/1100 600/1100 600/1000 600/1000 600/1000 600/1000 600/1000 600/1000
national and international Overall Height (mm) 2825/3325 2825/3325 2825/3325 2825/3325 2830/3230 2830/3230 2830/3230 2830/3230 2830/3230 2830/3230
our in-house technical teams.
regulations such as BS Height to Rim of Cover
2485/2985 2485/2985 2485/2985 2485/2985 2490/2890 2490/2890 2490/2890 2490/2890 2490/2890 2490/2890
∙∙ Can be upgraded to include NI Water (mm)
EN12255 and EN12566-3 (up
Controls and desludge system for NI Empty Weight (kg) 1100/1200 1200/1300 1315/1465 1660/1810 3000/3020 3100/3120 3200/3220 3300/3320 4200/4250 5500/5650
to 50 PE).
Water adoption.
Standard Power Supply 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase 1 phase
∙∙ Process designed to NIEA requirements. Motor Rating - 1 Phase
75 75 120 180 250 250 370 370 550 2 x 370
(Watts)
Full Load Current 1 Phase
1.1 1.1 1.3 1.6 1.5 1.5 2.35 2.35 2.8 2 x 2.35
(amps)
Optional Power Supply 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase
First Stage Second Stage Motor Rating - 3 Phase
90 90 120 180 250 250 370 370 550 2 x 370
Biological Treatment Biological Treatment (Watts)
Full Load Current 3 Phase
0.38 0.38 0.42 0.63 0.88 0.88 1.35 1.35 2.8 2 x 1.35
(amps)
Sludge Return Pump
250 250 250 250 250 250 250 250 250 250
Rating (watts)
Primary Final
Settlement Tank Settlement Tank
01 02 03 04
Primary Settlement Tank First Stage Biological Treatment Second Stage Biological Treatment Final Settlement Tank
This is the initial stage of treatment and simply involves the The liquor and fine solids then flow into the first stage of The liquor is then fed forward at a The surplus micro-organisms continuously slough off the discs and are carried forward
retention of coarse solids present in raw sewage and wastewater for Biological Treatment. A unique managed flow system ensures controlled rate into Biological Treatment to the final settlement where they settle out as a humus sludge, leaving a clear
subsequent gradual breakdown. BioDisc® features one chamber to peak performance by smoothing variable loads. stage 2 for further cleaning. This process treated effluent to be discharged to ground or water course. The settled humus sludge
ensure efficient operation with a flow balancing facility. ensures the whole media area available is is returned to the Primary Settlement Tank by the sludge return pump under timer
utilised ensuring maximum efficiency. control. The sludge return pump also removes any floating scum which helps to keep
the final settlement tank working efficiently.
— —
18 19
Water Management Solutions
BioDisc® modular RBC higher populations. System Model Reference Daily Flow (l/day) Daily Load (kg/BOD/day) Length(mm) Width(mm) Height(mm) Weight(kg) Motor Power
a complete modular
applications with higher
Max daily flow based on 200 L/Person/Day, system PE will vary by site flow rate per person.
with primary and final settlement tanks. system, supplied
populations, with each Both the RBC units and tanks can be
increased in numbers or size to make a
as 250PE modules.
Their unique design
unit supplied as a flexible system for an expanding or phased is containerised for Sectional Media Rotor Support
population growth. Modules Bearings
250PE unit. Each unit is supplied as a 250PE unit
ease of transport.
Flexible modular
and further units supplied depending on layouts available
population requirements. to suit even the
toughest site
Primary and final settlement tanks can
Due be sized for the intended end population
or additional tanks can be supplied in the
conditions.
Flow Management
Process
Strapping
Options
Spring future and fed into the system.
Each of the units can be linked to create
B ran d
2018! a complete sewage treatment system.
The feed to each RBC can be controlled
N ew independently to give further flexibility.
S o l u ti o n The RBC unit measures 6.7 metres long
x 2.2 metres wide x 2.4 metres high. The
size of primary and final settlement tanks
will vary with each customer application
and site location.
system
Primary
Settlement
01 02 03 04
Tank
Flow Management Process Sectional Media Modules Rotor Support Bearings Strapping/Lifting Options
The unique flow management The Biozone media within the The rotor assembly is supported The treatment plant can be
Primary Final process of the Klargester Klargester BioDisc® modular by a pillow block bearing at lifted from the side by forklift
Settlement Settlement commercial BioDisc® allows system, is built up in ‘wedge’ each end of the rotor shaft. truck. Forklift tubes are built
Tank Tank for complete flexibility of sections to make a two metre These are equipped with self into the steel construction
forward feed rate. Rotating diameter rotor assembly. lubricating grease cartridges to frame. The unit can also
buckets transfer untreated A complete wedge can be provide continual lubrication. be lifted at either end with
water through each of the removed from the rotor for Both of the bearings can the aid of extension forks.
BioZones, allowing for total maintenance or inspection be accessed by removing Alternatively, the unit can be
forward feed control. These without compromising the the individual covers for lifted with slings. Four lifting
are independently driven and overall rotor structure. This maintenance. It is not necessary brackets are attached to the
Primary Final
Settlement Settlement
allow the buckets to run at a ensures the rotor assembly can to remove the larger main frame and lifting shackles are
Tank Tank different speed to the rotor. stay in place, without the need covers, allowing for provided with each unit.
for removal. easier maintenance.
— —
20 21
Water Management Solutions
Commercial Sewage
Treatment Plant
in accordance with
performance using tried
560mm Inlet / 860mm Outlet Invert* 2.28 2.28 3.02 3.02 3.02 3.02 3.02 3.02 3.02
∙∙ May be installed in trafficked areas British Water Code 1060mm Inlet / 1360mm Outlet Invert* 2.78 2.78 3.52 3.52 3.52 3.52 3.52 3.52 3.52
and tested technology to (subject to loading). of Practice Flows
and Loads but can 1560mm Inlet / 1860mm Outlet Invert* 3.28 3.28 4.02 4.02 4.02 4.02 4.02 4.02 4.02
∙∙ Low maintenance.
ensure consistently high ∙∙ Alarm protected.
be sized to suit local 2060mm Inlet / 2360mm Outlet Invert* 3.78 3.78 4.52 4.52 4.52 4.52 4.52 4.52 4.52
Volume (m )
3
17 23 34 38 42 47 55 67 80
Weight Approx (kg) 1200 1450 3000 3200 3400 3800 4200 4700 5400
Applications:
Inlet / Outlet Diameter (mm) 160 160 160 160 160 160 160 160 160
The BioFicient range is suitable for a range
of applications including: Maximum Flow (m /day) Models
3
8 11 15 20 25 30 40 50 60
Campsites Offices
Biozone 1 Biozone 2
Multi-housing
developments
01 02 03 04
Primary Settlement Chamber Biozone 1 Biozone 2 Final Settlement Tank
This is the initial stage of treatment and simply involves The liquor enters the first stage of Biological treatment where Within the second stage of Biological treatment the second A natural by-product of biological treatment is humus sludge
the retention of coarse solids present in raw sewage and the active bacteria within the fluidized bed begin to break down fluidized bed continues to clean the liquor giving further BOD and this is separated for further treatment. The treated effluent
wastewater for subsequent gradual breakdown. BioFicient organic solids. The majority of BOD removal occurs here. reduction along with removal of nitrogen. is discharged via the outlet or to disinfection stage.
features two chambers to ensure efficient operation with
a flow balancing facility.
— —
22 23
Water Management Solutions
NSFA150 150 8335 15000 1500 8675 2820 600 2500 2450 1000 525
Source control
The use of SuDS should be considered at all sites and they should be incorporated where suitable. SuDS should be NSFA175 175 9725 17500 1750 9975 2820 600 2500 2450 1000 525
SuDS can be used to polish the effluent from these separators before it enters the environment6 considered where
possible NSFA200 200 11110 20000 2000 11,280 2820 600 2500 2450 1000 600
— —
24 * Some units have more than one access shaft – diameter of largest shown. 25
Water Management Solutions
Klargester Concentration
Less Than
Klargester Expert Technical
Advice
Bypass Forecourt
Separators
5
MG/L
Separators
MONITORING
MONITORING OF
OF
NSB RANGE
INTERCEPTORS /
Performance & Compliance
used when it is considered ∙∙ Light and easy to install.
› Fully compliant and tested to are used to intercept ∙∙ Operation ensures that the flow cannot
exit the unit without first passing
∙∙ The unit should be installed on a suitable
concrete base slab and surrounded with
an acceptable risk to not ∙∙ Inclusive of silt storage volume. EN 858-1.
hydrocarbon pollutants
SEPARATORS
SEPARATORS
through the coalescer assembly. concrete or pea gravel backfill.
∙∙ Fitted inlet/outlet connectors. › Bypass separators are
provide full treatment ∙∙ Vent points within necks. tested by British standards such as petroleum and ∙∙ In normal operation, the forecourt
separator has sufficient capacity to
∙∙ If the separator is to be installed within a
trafficked area, then a suitable cover slab
for very high flows, such ∙∙ Oil alarm system available (required by institute (BSI).
oil to prevent their entry provide storage for separated pollutants must be designed to ensure that loads are
EN 858-1 and PPG3). › Certified flow and process
as where the risk of a ∙∙ Extension access shafts for deep inverts. performance assessing to the drainage system. within the main chamber, but is also
able to contain up to 7,600 litres of
not transmitted to the unit.
∙∙ The separator should be installed and
large spillage and heavy effluent qualities to the
DODO Typical
YOU POSE applications
ANANOIL CONTAMINATION RISK? pollutant arising from the spillage of a
∙∙ Maintenance from ground level.
requirements of EN 858-1. YOU POSE OIL CONTAMINATION RISK? vented in accordance with Health and
fuel delivery tanker compartment on the
rainfall occurring at ∙∙ GRP or polyethylene construction
› The unit is designed to treat include petrol filling petrol forecourt.
Safety Guidance Note HS(G)41 for
I/II Concrete 10000 835 15 3915 2020 600 2180 2130 50 600 160 620
PPG3 STATES:
PPG3 STATES: INTERCEPTORS
INTERCEPTORS MUST HAVE
MUST A VISUAL
HAVE ANDAND
A VISUAL AUDIBLE WARNING
AUDIBLE WARNINGWHEN
WHENOIL OIL
I/II Concrete 10000 1115 20 3915 2020 600 2180 2130 50 600 200 620
REACHES 90%90%
REACHES STORAGE
STORAGE VOLUME
VOLUME
Technical Specifications
Peak Drainage Storage Access Base Base to Min Standard EUROPEAN STANDARD
EUROPEAN EN858-1-2:
STANDARD SUGGESTS
EN858-1-2: SEPARATORS
SUGGESTS SEPARATORS AREAREFITTED WITH
FITTED AN AN
WITH ALARM
ALARM
Model
Reference
Flow
(l/s)
Flow
Rate
Area(m2)
Based on UK
Capacity (Ltrs) Length
(mm)
Diameter
(mm)
Shaft
Diameter
Inlet
Invert
Outlet
Invert
Standard
Fall Across
Inlet
Invert
Pipework
Diameter
THAT
THAT FuelOF&EXCESSIVE
WARNS
WARNS Oil
OF LIQUID
EXCESSIVE LEVELS.
LIQUID
British European Standard EN 858-1 and
LEVELS.Environment Agency Pollution Prevention
Product Benefits
Separator Alarms
(mm)
(l/s) rainwater flow Silt Oil (mm) (mm) (mm) (mm) (mm)**
Guideline PPG3 requires that all separators ∙∙ Easily fitted to existing tanks.
Polyethylene Chamber Construction EXCESSIVE SILT,
EXCESSIVE OIL OIL
SILT, OR LIQUID LEVELS
OR LIQUID WILL
LEVELS PREVENT
WILLare to be THE
PREVENT fittedINTERCEPTOR
withINTERCEPTOR
THE FROM
an oil level alarm WORKING
FROM ∙∙ Excellent operational range.
WORKING
NSBP003 3 30 1670 300 45 1700 1350 600 1420 1320 100 500 160 EFFECTIVELY ALLOWING
EFFECTIVELY ALLOWINGOIL OIL
TO PASS THROUGH
TO PASS system.
ANDAND
THROUGH It should
POLLUTE be
POLLUTE installed and
WATERCOURSES. calibrated
WATERCOURSES. ∙∙ Visual and audible alarm.
by a suitably qualified technician so that
NSBP004 4.5 45 2500 450 60 1700 1350 600 1420 1320 100 500 160
it will respond to an alarm condition when ∙∙ Additional telemetry option.
NSBP006 6 60 3335 600 90 1700 1350 600 1420 1320 100 500 160 the separator requires emptying.
GRP Chamber Construction
ALARM INDICATES
ALARM INDICATES
NSBE010 10 100 5560 1000 150 2069 1220 750 1450 1350 100 700 315
HIGHHIGH
OIL LEVEL
OIL LEVEL
NSBE015 15 150 8335 1500 225 2947 1220 750 1450 1350 100 700 315
NSBE020 20 200 11111 2000 300 3893 1220 750 1450 1350 100 700 375
NSBE025 25 250 13890 2500 375 3575 1420 750 1680 1580 100 700 375
NSBE030 30 300 16670 3000 450 4265 1420 750 1680 1580 100 700 450
NSBE040 40 400 22222 4000 600 3230 1920 600 2185 2035 150 1000 500
NSBE050 50 500 27778 5000 750 3960 1920 600 2185 2035 150 1000 600
NSBE075 75 750 41667 7500 1125 5841 1920 600 2235 2035 200 950 675
NSBE100 100 1000 55556 10000 1500 7661 1920 600 2235 2035 200 950 750
NSBE125 125 1250 69444 12500 1875 9548 1920 600 2235 2035 200 950 750
ALARM INDICATES
ALARM INDICATES
* Some units have more than one access shaft – diameter of largest shown | ** Larger pipework available on request. HIGHHIGH
SILT SILT
LEVELLEVEL
— —
26 27
HOW THEY
HOW WORK
THEY WORK
DID YOU KNOW:
Water Management Solutions
W1/010 1000 500 3 1123 1225 460 1150 1100 50 500 160 60
Technical Specifications
W1/020 2000 1000 5 2074 1225 460 1150 1100 50 500 160 120
Dimensions (mm) Flow Rates Approx Weight (Kg) Fall Across W1/030 3000 1500 8 2952 1225 460 1150 1100 50 500 160 150
Model Reference Shipping Height (mm) Capacity (L)
Length Width (L/s) Empty Full The Unit (mm) W1/040 4000 2000 11 3898 1225 460 1150 1100 50 500 160 180
NSG01 1320 750 1 1100 500 70 570 75 W1/060 6000 3000 16 4530 1440 600 1360 1310 50 500 160 320
NSG02 1620 1100 2 1175 1000 90 1090 75
W1/080 8000 4000 22 3200 2020 600 2005 1955 50 500 160 585
NSG04 2072 1224 4 1570 2000 120 1860 70
NSG06 3018 1224 6 1570 3000 160 2820 70 W1/100 10000 5000 27 3915 2020 600 2005 1955 50 500 160 680
NSG09 3895 1224 9 1570 4000 190 3760 70 W1/120 12000 6000 33 4640 2020 600 2005 1955 50 500 160 770
NSG14 4418 1422 14 1745 6000 215 5535 70
W1/150 15000 7500 41 5435 2075 600 1940 1890 50 500 160 965
NSG18 3231 1917 18 2120 8000 300 7162 70
NSG24 4386 1917 24 2120 11000 380 9885 70 W1/190 19000 9500 52 6865 2075 600 1940 1890 50 500 160 1200
— —
28 29
Water Management Solutions
compact pump stations solution for outbuildings and extensions, ∙∙ Non-return valves and outlet pipe
compression coupling as standard.
stations are ideal for with single or twin pumps, and are ∙∙ Made with super-tough, low
maintenance GRP and high quality
cellars, pool houses and external WCs. suitable for sewage, surface water and
can be used for effluent They can be used for effluent or ∙∙ 3 pump options; effluent low head, homes or properties effluent. Appropriate for 24 hour storage polyethylene for guaranteed durability.
or sewage and are easy sewage, depending on the pump,
distance and height.
effluent high head and sewage vortex. with up to 13 people. requirements. ∙∙ Comes with options of remote
monitoring systems.
to install. ∙∙ Service and maintenance plans available
to prolong the life of the pump systems. ∙∙ Designed with easy access features for
∙∙ Complete pre-fabricated solution ready maintenance.
for installation. ∙∙ Choose from either 110mm or 160mm
∙∙ Fully automatic. inlet connections.
∙∙ Lockable covers for optimum security.
∙∙ Quick connection outlet couplings.
Chamber Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type Capacity Tank Control Capacity Tank Control
Chamber Size Alarm Pump Type Chamber Size Alarm Pump Type
(Ltrs) Material Panel (Ltrs) Material Panel
610 x 700 200 GRP N/A Optional Single
900 x 2580 1,600 GRP Included Optional Single/Twin 1000 x 2000 1450 Polyethylene Included Standard Single/Twin
560 x 1,650 400 GRP N/A Optional Single
900 x 2080 1,250 GRP Included Optional Single/Twin 1000 x 2500 2200 Polyethylene Included Standard Single/Twin
stations are suitable for Your system size will depend on the
∙∙ Application: domestic, residential or
Suitable for a wide range of applications,
the compact and domestic range of
type of waste you need to manage,
pumping wastewater your distance from the sewer and the commercial. Klargester Pumping Stations are suitable
effluent and sewage difference in levels. ∙∙ Material application: sewage, effluent or
surface water.
for the following types of applications
and many more:
in accordance with For expert advice, to help you select
the correct system, please contact our ∙∙ Inlet depth (below ground level).
BS 756-2.
Small Commercial Roof and
specialist team on: ∙∙ Pumping distance and lift. Offices Surface Water
NI: 028 3026 6799 | ROI: 048 3026 6799 ∙∙ Electrical supply.
or email: water-IE@kingspan.com Domestic Remote
Properties Classrooms
— —
30 31
Water Management Solutions
option.
are made from robust GRP. They are ∙∙ Inlet connection sizes to suit site. liquids and solids into a maintenance.
designed as a single-piece chamber, ready
for installation with no man-entry required. ∙∙ Various invert depths and positions. separate chamber and ∙∙ High-level alarm.
∙∙ Totally sealed system.
∙∙ GRP chambers with internal pipework in
plastic, galvanised or cast iron.
storing waste for up to 24 ∙∙ One-piece tank chamber for easy
∙∙ Optional kiosks with warning beacons hours. Once power is installation.
and optional telemetry systems. restored, the pumps will ∙∙ Minimal on-site assembly.
∙∙ Less cranage and shallower excavation
∙∙ Service and maintenance plans available
to prolong the life of the pump systems.
work normally again than concrete pumping stations.
without further ∙∙ On-site Health & Safety issues are
Tank Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type
Vertical Tank Size (mm) Capacity (Ltrs) Tank Material Control Panel Alarm Pump Type
2,600 Diameter 18000-79000 GRP Included Standard Single/Twin
1250 Diameter Up to 4,800 GRP Included Standard Single/Twin
customer requirements, the Klargester range stations are designed Manufactured as a ready to install
pre-fabricated unit for Type 1 and Type 2
of Horizontal and Vertical Pumping Stations
are typically used in applications including: to NI Water Standard installations for up to 20 dwellings.
Specification (May Product Benefits
2016) and meet the ∙∙ GRP single piece wet well delivered to
site ready to install.
Housing Caravan/ Surface Water
requirements of ∙∙ Pre-fitted internal pipework, pump
Developments Schools Camping Sites Run-off ‘Sewers for Adoption 7th guide rails and overflow filters.
—
Developments Restaurants Industry Standard’ (WIS). ∙∙ NI Water specified Controls and Hygiene —
32 unit. 33
Water Management Solutions
2 7
∙∙ Can reduce water consumption in When ordering your system, to make the
Tank Dimensions
domestic applications by up to 50%. Gravity System complete you will require
Model Standard Standard
Reference Standard ∙∙ Easy to install and simple to maintain. a header tank. Klargester offers a header
Capacity Overall Outlet Length Width
Height
Inlet Invert*
Invert* tank with weir, ballcock and float valve
∙∙ ‘Fit and Forget’ system, ensuring A
which allows the switch over to mains, the
Gravity System an automatic supply of harvested
01 The Gravity System
weir provides the mandatory air gap. C
rainwater.
GRW080 2,350 Ltrs 1,770mm 720mm 750mm 3,000mm 1,180mm The Gravity System uses B
an elevated header tank ∙∙ Shallow Dig—the Gamma is designed
GRW110 3,100 Ltrs 2,260mm 720mm 750mm 2,480mm 1,130mm to store filtered water with easy, affordable installation A Mains Input
after the main tank. B Rainwater Input E
in mind. D
GRW160 4,600 Ltrs 2,260mm 720mm 750mm 3,360mm 1,215mm C Water Regulations Compliant
∙∙ Pea shingle backfill available—no costly
Mandatory Air Gap F
Direct System 02 The Direct System excavation and soil disposal necessary
D Overflow Point
(dependent upon site conditions).
GRW080 2,350 Ltrs 1,768mm 720mm 750mm 3,000mm 1,180mm The Direct System pumps E Rainwater Level Control
water from the main ∙∙ Fully compliant—Gamma is tested F Mains Level Control
GRW110 3,100 Ltrs 2,260mm 720mm 750mm 2,480mm 1,130mm storage tank and is used in accordance with BS 8515:2009.
where a header tank is
impractical.
standards.
GRW160 4,600 Ltrs 2,260mm 720mm 750mm 3,360mm 1,215mm
Overview Aquabank is suitable for single residential Benefits of Installing Klargester Overview
applications. It uses cohesive design with Domestic Rainwater Systems 1. Pump power switch
The Klargester Aquabank rainwater the system controlled by a pump, with An economical rainwater harvesting
harvesting system is designed with system designed to make garden 2. Pumped water to required
options for either direct or gravity fed
simplicity in mind. watering simple. The Klargester application, e.g. garden hose,
applications. It’s a highly intuitive system
power washer
50
SAVE UP TO
– easy to use with no need for a control on water consumption in domestic RainTrap system comprises of a filter, an
% applications with Klargester underground storage tank and a pump. 3. Rainwater inlet (110mm)
panel, display panel or depth sensor.
Applications: Rainwater Harvesting solutions Rainwater runs down the roof and into 4. Submersible pump
Manufactured from strong GRP material, the guttering and downpipes in the
Aquabank is a complete ‘kit in a box’ – 5. Wastewater / overflow outlet
normal way before passing through the
easy to install and the smart choice for (110mm)
The system that pays for itself — filter, which removes any leaves or debris.
your home’s rainwater harvesting needs. money saved through reduced Rainwater is stored in the underground 1 6. Leaf filter
For home and garden use, the Aquabank water bills means aquabank can tank from which it is pumped at a constant 7. Safety manhole lid
Vehicle Washing Garden Watering is available in capacities between 1,000 pay back its purchase costs pressure to an outside tap as required.
and 6,000 litres. 2
The RainTrap has many advantages over
— traditional garden waterbutts. In addition
Features and Benefits Assists planning application — to being able to store far larger quantities
Authorities increasingly expect of water, it removes the need to carry
WC Flushing Domestic Laundry ∙∙ Easy to install. applications to Demonstrate water around and does not flood when
∙∙ Simplified system designed for Sustainable Drainage (SuDS) full, since the excess water exits via a
rapid installation. soakaway or surface water drain.
∙∙ Quick start set up procedure.
∙∙ ‘Kit in a box’ set of key components. 7
Features and Benefits
3
∙∙ Easy conversion to gravity system with
header tank. ∙∙ Easy to install.
∙∙ Minimal energy use in operation. ∙∙ Inexpensive. 6
∙∙ Simple on / off operation. 5
∙∙ Fully compliant - designed in accordance
with BS EN8515. ∙∙ Suitable for existing and new homes.
How it works ∙∙ Available in sizes from 1,000 — 6,000 litres.
∙∙ Automatic rainwater diversion when
tank reaches full capacity.
∙∙ Internal leaf filter.
∙∙ Designed and manufactured in the UK.
01 02 03
4
Rainwater is stored in underground tank Rainwater is pumped at a constant Water is pumped to a garden sprinkler or
pressure to an elevated header tank hose as required Technical Specifications
Model Capacity (Ltrs) Standard Overall Height Standard Inlet Invert Standard Outlet Invert Diameter / Width Length Model Reference Capacity (Ltrs) Diameter (mm) Height Base to Outlet (mm)
Gravity & Direct System RT2800 2,800 2,070 1,540
AQB010 1,000 2,140mm 500-800mm 530-830mm 1,225mm 1,125mm
RT3800 3,800 2,070 1,760
AQB028 2,800 2,582mm 500-1000mm 530-1030mm 2,070mm —
RT4600 4,600 2,080 1,925
AQB038 3,800 2,811mm 500-1000mm 530-1030mm 2,070mm —
The commercial range provides a secure Large installations are carefully sized and Features
solution for any size of building project selected, taking into consideration the
from 6,000 litres up to 79,000 litres following factors: ∙∙ Capacities from 6,000 to 79,000 litres
within a single tank. To speak with us about any aspect of
of water in a single tank. For larger
∙∙ Roof water yield. installation, commissioning or service
capacities, multiple tanks may be ∙∙ Multiple tanks can be joined to cater for
∙∙ Projected water consumption. simply contact:
connected together to meet storage larger volumes.
requirements. ∙∙ Groundwork criteria (prevailing water ∙∙ Can be installed under trafficked areas
table, soil conditions, requirements or Tel: 0333 240 6868
It is available as either a gravity or (with reinforced concrete support).
direct system, depending on specific site
traffic access).
∙∙ Complete packaged units delivered
Email: water-IE@kingspan.com
requirements. ∙∙ Suitable filters and pumps to match directly to site.
system specifications, ensuring the
kingspan.ie/klargester
water is kept at an optimum level of
clarity and supply pressure).
Technical Specifications
Single Pump Model Reference Twin Pump Model Reference Capacity (Ltrs) Diameter(m)
ENV0200SKSW ENV0200TKSW 6000 1.4
ENV0275SKSW ENV0275TKSW 8000 1.8
ENV0350SKSW ENV0350TKSW 10000 1.8
ENV0485SKSW ENV0485TKSW 14000 1.8
ENV0625SKSW ENV0625TKSW 18000 2.6
ENV0765SKSW ENV0765TKSW 22000 2.6
ENV0900SKSW ENV0900TKSW 26000 2.6
ENV1040SKSW ENV1040TKSW 30000 2.6
ENV1320SKSW ENV1320TKSW 38000 2.6
ENV1460SKSW ENV1460TKSW 42000 2.6
ENV1735SKSW ENV1735TKSW 50000 2.6
ENV2050SKSW ENV2050TKSW 59000 2.6
ENV2325SKSW ENV2325TKSW 67000 2.6
ENV2745SKSW ENV2745TKSW 79000 2.6
— —
38 39
UK Germany
Kingspan Environmental Ltd Kingspan Environmental GmbH
College Road North, Siemensstr. 12a, D-63263
Aston Clinton, Aylesbury, Neu-Isenburg, Deutschland
Buckinghamshire, HP22 5EW T: +49 (0) 6102 3686700
T: +44 (0) 1296 633000 E: wasser@kingspan.com
F: +44 (0) 1296 633001 W: kingspan.de/wasser
E: water@kingspan.com
W: kingspan.co.uk/klargester Australia
Kingspan Environmental Pty Ltd
Ireland 8 Bessemer St, Blacktown
Kingspan Environmental Ltd Sydney, NSW 2148
Unit 1a, Derryboy Road T: +61 (0) 2 8889 5400
Carnbane Business Park Toll Free: (within Australia)
Newry, BT35 6QH 1300 736 562
T: +44 (0) 28 3026 6799 E: sales.au@kingspan.com
E: water-IE@kingspan.com W: kingspan.com.au/water
W: kingspan.ie/klargester
Poland
Norway Kingspan Environmental Sp. z o.o.
Kingspan Miljø AS ul. Topolowa 5
Skiveien 42, 1410 Kolbotn, 62-090 Rokietnica
Norway Polska
T: +47 22 02 19 20 T: +48 61 660 94 71
E: avlopslosninger@kingspan.com E: woda@kingspan.com
W: kingspanklargester.com/no W: kingspan.pl/woda
We take every care to ensure that the information in this document is accurate at the point of publication, but
with continuous product development, details are subject to alteration without notice.