You are on page 1of 5

L2 Trouble Shooting TCL Communication Ltd.

2.1 Power on issue

-----------------Workflow----------------------------------Reference pic/comment--------
Power on failure

Charge the phone more than


20 minutes and check whether
it can power on

Check whether The Clean the contacts on


connection between USB N Furnished back cover or
cable and product is good replace a new one

DL tool for MT30 is


Make a factory reset/software
upgrade and then check whether the “Sugar_QCT_SP”, please
device is normal
(Refer to L1 repair document)
refer to<Instructions of
SUGAR Tool>
Y

Make a disassembly process


to check whether Main PCBA
appearance is normal
(electric shocks, copper skins
and etc.)
Y

N Check whether the


reweld/replace connector or
connection between battery N
and PCBA is good replace battery

Check whether the connection Clear Antenna spring or


between Furnished FPC and N Reweld connector or replace
PCB is good(Antenna part & Furnished FPC
connector part on FPC)

Check if PCBA power-on


current is normal by using a Y Turn to display failure
DC power

Replace PCBA

Rev. Page
General L2 Trouble Shooting
1.2 1/5

All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
L2 Trouble Shooting TCL Communication Ltd.

2.2 Charge issue

-----------------Workflow----------------------------------Reference pic/comment --------

Charging failure
(Power-on status)

Check if the connection between Clean contacts on back


USB cable and charging port is N cover or replace a new
normal USB cable

Make a factory reset/software


DL tool for MT30 is
upgrade and then check whether the “Sugar_QCT_SP”, please
charging function is normal
(Refer to L1 repair document) refer to<Instructions of
N SUGAR Tool>

Check whether the battery


status is normal Replace a new
(Check voltage & resistance N
battery
parameter by using a multimeter)

Make a disassembly process to


check whether Main PCBA
appearance is normal(electric
shocks, copper skins and etc.)

Check whether the connection Clear Antenna spring or


between Furnished FPC and Reweld connector or
N
N PCB is good(Antenna part & replace Furnished FPC
connector part on FPC)

Replace PCBA

Rev. Page
General L2 Trouble Shooting
1.2 2/5

All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
L2 Trouble Shooting TCL Communication Ltd.

2.3 Display issue

-----------------Workflow------------------------------------------------Reference Pic-------
Display failure
(Power on status)

Y
DL tool for MT30 is
Make a factory reset/software
upgrade and then check whether the
“Sugar_QCT_SP”, please
device is normal (Refer to L1 repair refer to<Instructions of
document)
SUGAR Tool>
N

Make a disassembly process to


check whether Main PCBA
appearance is normal(electric
shocks, copper skins and etc.)

Reassemble Furnished
Check whether the connection
underfilling or reweld
between Furnished underfilling and N
Furnished underfilling
Furnished underfilling connector is
N connector
good

Check whether Furnished Replace Furnished


N underfilling connector
underfilling connector is
normal

Check whether Furnished Replace Furnished


N underfilling
underfilling is normal
(interchange method)

Replace PCBA

Rev. Page
General L2 Trouble Shooting
1.2 3/5

All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
L2 Trouble Shooting TCL Communication Ltd.

2.4 Device power consumption issue

-----------------Workflow------------------------------------------------Reference Pic--------
Device power
consumption issue

Y
DL tool for MT30 is
Make a factory reset/software
upgrade and then check whether
“Sugar_QCT_SP”, please
the device is normal refer to<Instructions of
(Refer to L1 repair document)
SUGAR Tool>
N

Make a disassembly process to


check whether Main PCBA N Replace Main PCBA
appearance is normal(electric
shocks, copper skins and etc.)

Check whether the consumption of


the Main PCBA is normal Replace Main
N
(PCBA consumption check method) PCBA

Check whether the battery


status is normal
(Check voltage & resistance N Replace a new battery
parameter by using a multimeter)

PCBA power consumption check method:

In order to improve the power consumption of a device, we can check the power consumption of the device
by simulating a battery using power supply as follows:

Step 1. Please prepare a battery connector assembly and a standard power supply cables as shown in the
picture below;

Rev. Page
General L2 Trouble Shooting
1.2 4/5

All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
L2 Trouble Shooting TCL Communication Ltd.

Note: You can find the battery connector assembly inside a battery ready to be scrapped.

Step 2. Set the voltage of the power supply at 4.0V, connect the battery connector assembly to the device
and power supply (Keep the mobile on switch off mode).

Step 3. Read the consumption of the device on power supply.

Value on power supply Conclusion


0mA~0.2mA PCBA is OK
>0.2mA PCBA is NOK(Overconsumption)

Rev. Page
General L2 Trouble Shooting
1.2 5/5

All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.