Result Summary geometries & weld limitations = FAIL limit states max ratio = 0.29 PASS
Min Fillet Weld Size Is this a result of hard conversion from imperial to metric.
Weld capacity ratio at 0.29
Thinner part joined thickness t= = 14 [mm]
Min fillet weld size allowed w min = =6 [mm] AISC 15 th Table J2.4
< w min NG
≥ L min OK
Brace Force Load Case 1 Gusset plate t=15.9 P =700.0 kN (C) ratio = 0.21 PASS
Gusset Plate - Axial Tensile Yield ratio = 195.5 / 3061.1 = 0.06 PASS
Brace Force Load Case 2 Gusset plate t=15.9 P =-700.0 kN (T) ratio = 0.29 PASS
Gusset Plate - Axial Tensile Rupture ratio = 195.5 / 3768.4 = 0.05 PASS