You are on page 1of 2

F-PR-07-08/02

23-11119-001 PChem Report


Iss.03 Rev. 02
Effectivity: September 22, 2022

PAB ACCREDITTED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2012-217C

Department of Environment and Natural Resources • DA - Bureau of Animal Industry • Department of Health • Food and Drug Administration

CERTIFICATE OF ANALYSIS
Customer : JERYL C. HIJE / TECHNOLOGICAL INSTITUTE OF THE PHILIPPINES Work Order : 23-11119
Address : Quezon City, Manila Date Collected : November 28, 2023
Date Received : November 28, 2023
Date Analyzed : November 28, 2023 - December 07, 2023
Date Reported : December 07, 2023
Time Collected:2:00 AM
Submitted By : Customer

RESULTS OF ANALYSIS:

Customer Sample ID : Water - Deepwell Lab Sample ID: 23-11119-001


PARAMETER METHOD MAXIMUM ALLOWABLE RESULT
LEVEL (MAL) ᵃ
Arsenic* 3114 C. Continuous Hydride 0.01 mg/L 0.0132 mg/L
Generation/Atomic Absorption Spectrometric ᵇ
Cadmium 3111 B. Direct Air-Acetylene Flame ᵇ 0.003 mg/L <0.003 mg/L

Color (Apparent) 2120 B. Visual Comparison ᵇ 10 CU <5 CU

Lead 3111 B. Direct Air-Acetylene Flame ᵇ 0.01 mg/L <0.01 mg/L

Nitrate as NO3-N 4500-NO3-D Nitrate Electrode Method ᵇ 50 mg/L 0.68 mg/L

pH 4500-H+ B. Electrometric ᵇ 6.50 - 8.50 7.56 @ 23.2 °C

Residual Chlorine* DPD - Chlorine Photometer ᶜ 0.300 - 1.50 mg/L <0.01 mg/L

Total Dissolved Solids 2540 C. Gravimetric, Dried at 180°C ᵇ 600 mg/L 448 mg/L

Turbidity* 2130 B. Nephelometric ᵇ 5 NTU 0.44 NTU

Sample Description/Condition: The sample is clear and received in plastic container transported with ice.
References: ᵃ Maximum Allowable Level (MAL)/Standard Values and Methods of analysis are based on Philippine National
Standards for Drinking Water, Department of Health Administrative Order No. 2017-0010, June 23, 2017
ᵇ Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 2017
ᶜ Chlorine Photometer Operations Manual
Remark/s: *Test outside the laboratory's scope of accreditation.

Certified True and Correct by: Approved by:

Ranmar Marco A. Marco, RCh Jennifer R. Maralit, RCh


Laboratory Supervisor General Manager
PRC Lic. #0014151 PRC Lic. # 0007374

Results of analysis refer only to the sample of material submitted by the customer. This report/certificate cannot be reproduced without
written authorization from Optimal Laboratories, Inc. and Not Valid without official Company dry seal. This will be file for 5 years from date of issue.

Purok I , Balintawak, Lipa City, Batangas Physico - Chemical Analysis for Foods, Feeds & Pharmaceutical Products
Tel. Nos.: (043) 774-5037 / 233-1149 / 461-5020 Microbiological Testing / Stability Testing
Manila Line No.: (02) 8806-2863 Water and Wastewater Analysis & Monitoring
Mobile: + 63917-5293-742 / +63998-5914-695 Ambient Air / Stationary Source Emission Sampling & Analysis
Email: optimal_lab@hotmail.com
Website: www.optimallabinc.com.ph

Final_12072023_1923_23-11119_23-11119-001 Page 1 of 1
F-PR-07-08/03
Iss.03 Rev. 02
Effectivity: September 22, 2022

PAB ACCREDITTED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2012-218C

Department of Environment and Natural Resources • DA - Bureau of Animal Industry • Department of Health • Food and Drug Administration

CERTIFICATE OF ANALYSIS
Customer: JERYL C. HIJE / TECHNOLOGICAL INSTITUTE OF THE Work Order : 23-11119
PHILIPPINES Date Collected : November 28, 2023
Address: Quezon City, Manila Date Received : November 28, 2023
Date Analyzed : November 28, 2023 - December 07, 2023
Date Reported : December 07, 2023
Time Collected: 2:00 AM
Submitted By : Customer

RESULTS OF ANALYSIS:

Customer Sample ID : Water - Deepwell Lab Sample ID: 23-11119-001

PARAMETER METHOD STANDARD VALUES RESULT

Heterotrophic Plate Count Pour Plate < 500 CFU/mL ᵃ *>5,700 CFU/mL
Thermotolerant (Fecal) Multiple Tube Fermentation Technique < 1.1 MPN/100 mL ᵃ < 1.1 MPN/100 mL
Coliform Count
Total Coliform Count Multiple Tube Fermentation Technique <1.1 MPN/100 mL ᵃ >8.0 MPN/100 mL

Sample Description/Condition: The sample is clear and received in plastic bottle transported with ice.
References: ᵃ Philippine National Standards for Drinking Water 2017
Remark/s: * Estimated Count

Certified True and Correct by: Approved by:

Jonahdimary R. Alilio Shyla May L. Quizon, RMT Jennifer R. Maralit, RCh


Laboratory Supervisor Laboratory Analyst II General Manager
PRC Lic. #0075710 PRC Lic. # 0007374

Results of analysis refer only to the sample of material submitted by the customer. This report/certificate cannot be reproduced without
written authorization from Optimal Laboratories, Inc. and Not Valid without official Company dry seal. This will be file for 5 years from date of issue.

Purok I , Balintawak, Lipa City, Batangas Physico - Chemical Analysis for Foods, Feeds & Pharmaceutical Products
Tel. Nos.: (043) 774-5037 / 233-1149 / 461-5020 Microbiological Testing / Stability Testing
Manila Line No.: (02) 8806-2863 Water and Wastewater Analysis & Monitoring
Mobile: + 63917-5293-742 / +63998-5914-695 Ambient Air / Stationary Source Emission Sampling & Analysis
Email: optimal_lab@hotmail.com
Website: www.optimallabinc.com.ph

Final_12072023_1923_23-11119_23-11119-001 Page 1 of 1