5. Troubleshooting
●
Motor does not run ●
Check that the plug is securely ●
Plug in firmly
turned on inserted into outlet ●
Push it completely into the brush
●
Check that the carbon-brush is not holder or replace it
severely worn Check that the hook ●
Replace if motor does not run
in the carbon brush in separated when turned on.
●
Check that the power switch is ●
Replace it if broken.
turned on Check that the contact at
the cord-reel area is ok
●
Slide control does not ●
Check that the slide switch is not ●
Replace it
adjust broken
●
Check that the triac is not shorted ●
Replace it
●
Check that the base plate is not
broken ●
Replace it
●
Cord does not rewind ●
Check that the cord is not twisted or ●
Pull the cord out 1~2m and push
fully wound unevenly down the rewinding button
●
Check that the spring is not weak or ●
Replace the power cord if it does not
broken fully rewind
●
Cord rewinds by itself ●
Check that the lever is not broken ●
Replace it
●
Suction power is ●
Check that the floor nozzle or the ●
Remove the object
week hose is clogged with a large object
●
Check that the cover is attached ●
Attach the cover properly
firmly to the body
●
Check that the hose is firmly ●
Insert the hose firmly
inserted
●
The needle of the ●
Check that the floor nozzle or the ●
Remove the object
dust indicator is in the hose is not clogged with a large
red position object ●
Replace the spring
●
Check that the spring of the dust
indicator is ok ●
Clean the sponge
●
Check that the filter sponge is clean
진공청소기 14
5. Troubleshooting
Voltage between P1
Terminals
DC Voltage of Vcc
and Gnd(U1 : 1-8pin)
15 삼성전자
6. PCB Error Diagnosis & Checking
Voltage between P1
Terminals
진공청소기 16
6. PCB Error Diagnosis & Checking
Voltage between P1
Terminals
Measure a secondary
Voltage of TRANS
17 삼성전자