5. Troubleshooting

PROBLEM CHECK REMEDY


Motor does not run ●
Check that the plug is securely ●
Plug in firmly
turned on inserted into outlet ●
Push it completely into the brush

Check that the carbon-brush is not holder or replace it
severely worn Check that the hook ●
Replace if motor does not run
in the carbon brush in separated when turned on.

Check that the power switch is ●
Replace it if broken.
turned on Check that the contact at
the cord-reel area is ok


Slide control does not ●
Check that the slide switch is not ●
Replace it
adjust broken

Check that the triac is not shorted ●
Replace it

Check that the base plate is not
broken ●
Replace it


Cord does not rewind ●
Check that the cord is not twisted or ●
Pull the cord out 1~2m and push
fully wound unevenly down the rewinding button

Check that the spring is not weak or ●
Replace the power cord if it does not
broken fully rewind


Cord rewinds by itself ●
Check that the lever is not broken ●
Replace it


Suction power is ●
Check that the floor nozzle or the ●
Remove the object
week hose is clogged with a large object

Check that the cover is attached ●
Attach the cover properly
firmly to the body

Check that the hose is firmly ●
Insert the hose firmly
inserted


The needle of the ●
Check that the floor nozzle or the ●
Remove the object
dust indicator is in the hose is not clogged with a large
red position object ●
Replace the spring

Check that the spring of the dust
indicator is ok ●
Clean the sponge

Check that the filter sponge is clean

진공청소기 14
5. Troubleshooting

6. PCB Error Diagnosis & Checking


6-1. Body Rotary V/R Control (MICOM)

Voltage between P1
Terminals

AC 220V~240V? Wire-cut in Power Cord

Supply voltage is directly applied.


Short T1 and T2 of TRI1 So, make sure to apply power carefully.

Motor Defect or Wire-cut in


Motor rotates?
Motor Connection

Supply voltage is directly applied.


Short T2 and G of TRI1
So, make sure to apply power carefully.

TRI1 Breakage or Copper


Motor rotates?
Foil Breakage around it

DC Voltage of Vcc
and Gnd(U1 : 1-8pin)

DC 4~6V? PBA MAIN Defect

PBA MAIN Defect

15 삼성전자
6. PCB Error Diagnosis & Checking

6-2. Body Rotary V/R Control (R/C)

Voltage between P1
Terminals

AC 220V~240V? Wire-cut in Power Cord

Supply voltage is directly applied.


Short T1 and T2 of TRI1 So, make sure to apply power carefully.

Motor Defect or Wire-cut in


Motor rotates?
Motor Connection

Supply voltage is directly applied.


Short T2 and G of TRI1 So, make sure to apply power carefully.

TRI1 Breakage or Copper


Motor rotates?
Foil Breakage around it

PBA MAIN Defect

진공청소기 16
6. PCB Error Diagnosis & Checking

6-3. Handle Slide V/R Control (R/C)

Voltage between P1
Terminals

AC 220V~240V? Wire-cut in Power Cord

Measure a secondary
Voltage of TRANS

AC 22~26V? Wire-cut in TRANS

Supply voltage is directly applied.


Short T1 and T2 of TRI1
So, make sure to apply power carefully.

Motor Delect or Wore-cut in


Motor rotates?
Motor Connection

Supply voltage is directly applied.


Short T2 and G of TRI1
So, make sure to apply power carefully.

TRIAC Breakage or Copper


Motor rotates?
Foil Breakage around it

Short 4~5 of PC1 Supply voltage is directly applied.


So, make sure to apply power carefully.

Motor rotates? PC1 Defect

Change PBA MAIN