Things we are good at

Electrical Panels

 HT Panels (ht-panels.php)

 LT Panels (lt-panels.php)

HT Panels
H T Panels Range : 3.3 KV to 33 KV

https://www.canscorp.com/ht-panels.php 1/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

SPECIFICATIONS OF HT PANEL UP TO 24 KV

https://www.canscorp.com/ht-panels.php 2/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

: VCB ‘EVOLIS AND ‘HVX’ Model


Switchgear Type Horizontal draw out & horizontal isolation
Easy interchangeability of breaker due to full draw out

: IP 4X – Indoor duty
Protection
IP 55 – Outdoor duty weather proof KIOSK (optional)

: A) Metal clad fully enclosed design floor mounting & free standing
B) Made out of minimum 2 mm CRCA sheet
SSheet metal work on CNC machines
Construction
C) Compartmentalized Construction
D)Extensible on both sides.
E)Powder coating @ 80-100 micron thickness

Voltage rating : 3.3 / 6.6 / 12 / 17.2 / 24 KV

Current rating : 630 / 800 / 1250 / 1600 / 2500 Amps

: 25 KA for 3 sec
Fault level
40 KA for 3 sec (optional)

A) Explosion vent
B) Safety wire mesh on cable chamber side
C)Automatic safety shutters for safety of operating personals
D)Hermetically sealed vacuum interrupters to protect the
Safety features contacts from oxidation , corrosion & contamination
E)Danger boards
F)Earthing switch (optional)
G) Live line indication (optional)
H) anti pumping feature (built in)

: Single or double air insulated


Bus bars
Aluminum / Copper with heat shrinkable sleeve (optional)

Insulators : SMC / DMC

Type testing : As per IEC-62271 – 200 (2003), IEC – 60529,2001

: External 24 /48 /110 /220 VDC for relays, trip,close coils.


Control Supply
230 VAC for space heaters / spring charging motor

Power Pack :Optional

https://www.canscorp.com/ht-panels.php 3/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

: Mainly used for operation & protection of public,


Application
Industrial and tertiary distribution of network from 3.3 kV to 24 kV

ELECTRICAL CHARACTERISTICS UPTO 24 KV

KV 7.2 12 17.5 24

KV
Rated
Ur 50/60 7.2 12 17.5 24
voltage
Hz

Insultation
level

- power KV 50
frequency Ud Hz 1 20* 28* 38* 50
withstand min

-
lightning
Up KV peak 60 75 95 125
impulse
withstand

Rated
Ir A 630 -
current

1250 -

2000 - - - - - - - - -

2500

Short
Circuit Isc KA 25 31.5 40 25 31.5 40 25 31.5 40 16 25
Current

Short time
KA/ 3
withstand Ik/tk 25 31.5 40 25 31.5 40 25 31.5 40 16 25
sec
current

https://www.canscorp.com/ht-panels.php 4/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

Short - Ip KA peak 50Hz 63 79 100 63 79 100 63 79 100 40 63


circuit
making
60Hz 65 82 104 65 82 104 65 82 104 42 65
current

O-3 min - CO - 3
min - CO

Rated switching O - 0.3 s - CO - 3


sequence min - CO

O - 0.3 s - CO -15
s - CO

Opening ms < 50 <60

Operating time Breaking ms < 60 <60

Closing ms < 71 < 70

Service
°C - 25 to + 40 - 25 to + 40
Temperature

M2 M2
Mechanical Class No. of
endurance switching op.
10,000 10000

Electrical
Class E2 E2
Endurance

16 KA - 100

No. of switching 25 KA 100 100


operations at full
Isc value 31.5KA 50 100

40KA 30 -

Capacitive
Current
class C1 C1 - C2
breaking
capacity

Available; - Not Available


https://www.canscorp.com/ht-panels.php 5/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

SPECIFICATION OF 36 KV HT PANEL

: HVX Model
- Horizontal draw out & horizontal isolation easy interchangeability
Switchgear Type
of breaker due to full draw out facility
- Draw out & fixed

: IP 4X – Indoor duty
Protection
IP 55 – Outdoor duty weather proof KIOSK (optional)

: A) Metal clad fully enclosed design floor mounting & free standing
B)Made out of minimum 2 mm CRCA sheet.
Sheet metal work on CNC machines.
Construction
C)Compartmentalized Construction
D)Extensible on both sides.
E) Powder coating @ 80-100 micron thickness

Voltage rating : 36 KV

Current rating : 630 / 800 / 1250 / 1600 / 2500 AMPS

:25 KA for 3 sec


Fault level
40 KA for 3 sec (optional)

: A) Explosion vent
B)Safety wire mesh on cable chamber side
C) Automatic safety shutters for safety for safe guarding
Safety features
operating personals
D)Hermetically sealed for life SF6 gas chamber
E)Danger boards

:Single or double air insulted


Bus bars
Aluminum / Copper with heat shrinkable sleeve (optional)

Insulators :SMC / DMC

: As per IEC-60529, 2001 , IEC –62271-100,2008 & IEC-62271-


Type testing
200, 2003

Control Supply : External 24 / 48 / 11o / 22o VDC for relays, trip, close coils.

Charging Motor : 230 VAC for space heaters / spring


https://www.canscorp.com/ht-panels.php 6/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

Power Pack : Optional

: Mainly used for operation & protection of public, Industrial and tertiary
Application
distribution of network from 3.3 KV to 24 KV

ELECTRICAL CHARACTERISTICS UPTO 36 KV

Rated voltage Ur KV 50/60 Hz 36 40.5

Insultation level

- power frequency
KV 50 Hz 1
Ud 70 95
withstand min

- lightning impulse
Up KV peak 170 185
withstand

Ir A 1250

2500

3150 - - - -

Short Circuit Current Isc KA 25 31.5 40 31.5

Short time withstand


Ik/tk KA/ 3 sec 25 31.5 40 31.5
current

Short - circuit making Ip KA peak 50Hz 62.5 79 100 79

current
60Hz 65 82 104 82

O-3 min - CO -
3 min - CO

O-3 min - CO -
Rated switching sequence
3 min - CO

O - 0.3 s - CO
-15 s - CO

https://www.canscorp.com/ht-panels.php 7/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

Phase to Phase mm 300

Opertatin mechanism Frontal

Operating times Opening (ms) <50

Breaking (ms) <60

Closing (ms) <65

Service Temperature T °C - 25 to + 40

Class M2

Mechanical endurance
Number of
10,000
Switching

Electrical Endusrance Class E2

Capacitive Current breaking


Class C2
capacity

Available; - Not Available

Have Any Questions

Don't Hesitate to contact us and get the solution

E-mail Address SIGN UP

About

https://www.canscorp.com/ht-panels.php 8/9
2/16/24, 11:27 AM CANSCORP ENGINEERS PVT LTD

CANSCORP Engineers Pvt Ltd is coveted as a corporate of high repute in the industry; recognized for its high
quality standards, unique designs, impeccable finishing and timely deliveries of MEP Services. Together with
all its group companies, the firm offers a comprehensive range of solutions for myriad business requirements.

   
Useful Links

 Home (index.php)

 About Us (about.php)

 Services (electrical-system.php)

 Manufacturing (electrical-panels.php)

 Renewable Energy (solar-epc-solutions.php)

 Contact Us (contact.php)

Contact Info

 CANSCORP ENGINEERS PVT LTD


Shop No 5,Adinath Alpine building
Plot No 28 A,Sector 25,


Khandeswar,Navi Mumbai Maharastra 410209

+919372906466
info@canscorp.com

Monday - Friday: -------------------------- 9:00 am - 18:00 pm


Saturday: ------------------------------------ 9:00 am - 16:00 pm
Sunday ---------------------------------------- Closed

© 2019 CANSCORP ENGINEERS PVT LTD. All rights reserved.

Designerd By Vihar Infotech

https://www.canscorp.com/ht-panels.php 9/9

You might also like