Troubleshooting System Wiring, Switches,

and Fuses
Symptom: Cause Result Action

Switches in the system are Photovoltaic electricity


Load does not turned off or are in the wrong cannot be supplied to Put all switches in correct position
operate at all position loads or batteries

System circuit breakers or Reset circuit breaker or


fuses are blown replace fuse*

Load operates There is a high voltage drop in


poorly or not the system Check for Inadequate voltage to
at all undersized or too-long wiring. charge batteries or Increase wire size, reduce
over too-long wiring. operate loads load size, find and
over-sized loads a ground correct ground faults
fault, or a defective diode

Wiring or connections are loose, Repair or replace damaged


broken burned or corroded wiring or connections

Wiring or connections are


short-circuited or have a Repair short circuits or
ground fault ground faults