<< Initial setting procedure for JHS-180, AIS >> 1/18/03

@ Remarks:
A. To have the system energize the power, the power supply unit has to be
turned on by the Master Key.
B. To turn the power off, a Pass Word is required. (Factory default: 0000)
In case a pass word has been already put in, another number, “0180” can be
used. (The use of the number is limited to “serviceman” only.)
C. After the initial settings below, turn the power off and on again -this action be
required for proper operation.
D. If “Error 8” is displayed on the screen or the Controller locks up, do the setup
below correctly, as wrong /non- setup may cause these symptoms.

For the initial settings,


1) After turning the power on, press MENU & PWR down for a while till the message "AIS
Controller Now Loading…." appeared.
2) Choose the no.9 item, "INITIALIZE" in the Main Menu and the following items will be
appeared: 1. Sensor setting …(Page 18 of Op. Manual)
2. Internal GPS setting …(P19)
3. Ship static data setting …(P20)
4. Transponder initialize
5. Antenna selection
3) In the 1. Sensor setting, select the "Sentence" of the NMEA data in accordance to each
sensor hooked up at the terminal (TB1 of the NQE-3111, Connection Box).
-See the list below: <Recommended> <Optional>
Longitude/Latitude, etc.: GNS, GLL GGA, RMC
Datum Reference : DTM
RAIM Indicator : GBS
Speed Over Ground(SOG) : VBW VTG, OSD, RMC
Course Over Ground(COG) : RMC VTG, OSD
Heading : HDT OSD, HDG
Rate of turn : ROT
For example, if you hook up GPS signal at Sensor 1(RX-A & RX-B) at the TB1, you can
choose "DTM" and "GNS" & "GLL" among the selection list on the screen.
4) In the 2. Internal GPS setting, input the AIS Transponder (GPS antenna included) position in
the columns (length from Bow, Stern, Port & Starboard).
5) In the 3. Ship static data setting, input the following important status:
A) Ship's name; B) MMSI no.; C) IMO no.; D) Call Sign
In addition, input the external GPS position by the same way of the above 6).
6) Leave the 4. Transponder initialize & 5. Antenna selection settings -no need to be
set up unless any particular problem happened.
7) In the Main Menu, choose the 8. Field Maintenance and confirm the Sync Status is to be
"UTC DIRECT", meaning that the internal GPS in AIS transponder is working properly. (See
page 6.)
<< Troubleshooting for JHS-180, AIS >>

If you encounter the Alarm Indication(s), refer to the table below:


ALM No. Indication System Status Possible to fault units

001 TX malfunction TX unit defective CMN-2180 TRX unit

002 ANT VSWR exceeds limits VSWR is too high, would be detected by CPU CMN-2180 TRX unit

Defective antenna connected

Mis-selection of external antenna

by maintenance menu.

003 RX ch1 malfunction PLL for RX ch1 is unlocked CMN-2180 TRX unit

004 RX ch2 malfunction PLL for RX ch2 is unlocked CMN-2180 TRX unit

005 RX ch70 malfunction PLL for RX ch70 is unlocked CMN-2180 TRX unit

006 General failure

008 MKD connection lost Would not able to communicate between Cable between transponder and

transponder and controller controller

No MMSI number is installed Needs to enter MMSI number

025 External EPFS lost No GPS data comes in or invalid External GPS

Sensor input setting

026 No sensor position in use Neither external GPS nor internal GPS data External GPS

comes in or invalid. Sensor input setting

CAG-2180 LNA unit

CDJ-2180 control unit

029 No valid SOG information Neither external GPS nor internal GPS data External GPS

comes in or invalid. Sensor input setting

CAG-2180 LNA unit

CDJ-2180 control unit

030 No valid COG information Neither external GPS nor internal GPS data External GPS

comes in or invalid. Sensor input setting

CAG-2180 LNA unit

CDJ-2180 control unit

032 Heading lost/invalid No heading data comes in or invalid Gyro

Sensor input setting

035 No valid ROT information NO ROT data comes in or invalid Gyro

Sensor input setting

051 TX power down Transmit power is reduced below lower CMN-2180 TRX unit

limits. Defective antenna connected

Mis-selection of external antenna

by maintenance menu.

052 TX power supply error Internal power line voltage exceeds limits CDJ-2180 control unit

during transmitting.

053 Power supply error Internal power line voltage exceeds limits CMN-2180 TRX unit
during receiving.

054 PA current error PA current draw exceeds limits. CMN-1280 TRX unit

055 PA temp error PA temperature exceeds limits. CMN-2180 TRX unit

056 TX power low Forwarding power is reduced below lower CMN-2180 TRX unit

limits. Defective antenna connected

Mis-selection of external antenna

by maintenance menu.

057 Vr error VSWR protector is ON. Defective antenna connected.

Mis-selection of external antenna

by maintenance menu.

058 Ic error PA over current protector is ON. CMN-2180 TRX unit

060 TX PLL unlock PLL for TX is unlocked. CDJ-2180 control unit

062 Program flash memory error Wrong program data is detected. CDJ-2180 control unit

063 Data flash memory error Wrong data memory is detected. CDJ-2180 control unit