A. To have the system energize the power, the power supply unit has to be
turned on by the Master Key.
B. To turn the power off, a Pass Word is required. (Factory default: 0000)
In case a pass word has been already put in, another number, “0180” can be
used. (The use of the number is limited to “serviceman” only.)
C. After the initial settings below, turn the power off and on again -this action be
required for proper operation.
D. If “Error 8” is displayed on the screen or the Controller locks up, do the setup
below correctly, as wrong /non- setup may cause these symptoms.
002 ANT VSWR exceeds limits VSWR is too high, would be detected by CPU CMN-2180 TRX unit
by maintenance menu.
003 RX ch1 malfunction PLL for RX ch1 is unlocked CMN-2180 TRX unit
004 RX ch2 malfunction PLL for RX ch2 is unlocked CMN-2180 TRX unit
005 RX ch70 malfunction PLL for RX ch70 is unlocked CMN-2180 TRX unit
008 MKD connection lost Would not able to communicate between Cable between transponder and
025 External EPFS lost No GPS data comes in or invalid External GPS
026 No sensor position in use Neither external GPS nor internal GPS data External GPS
029 No valid SOG information Neither external GPS nor internal GPS data External GPS
030 No valid COG information Neither external GPS nor internal GPS data External GPS
051 TX power down Transmit power is reduced below lower CMN-2180 TRX unit
by maintenance menu.
052 TX power supply error Internal power line voltage exceeds limits CDJ-2180 control unit
during transmitting.
053 Power supply error Internal power line voltage exceeds limits CMN-2180 TRX unit
during receiving.
054 PA current error PA current draw exceeds limits. CMN-1280 TRX unit
056 TX power low Forwarding power is reduced below lower CMN-2180 TRX unit
by maintenance menu.
by maintenance menu.
062 Program flash memory error Wrong program data is detected. CDJ-2180 control unit
063 Data flash memory error Wrong data memory is detected. CDJ-2180 control unit