Project: 111 Consultant: --

Location: Date: 6/24/21 10:48 PM


Tag: CHILLER ACDS-R410A-1
PERFORMANCE SUMMARY
Location:

Scroll Compressor Air Cooled Package Chiller


Model # ACDS095AUGS Manufacturer DBM
Quantity 1 Rating version ACDG25

Physical Specifications
Compressors Qty 4 Shipping weight (lb) 6,677
Length (in) 192.00 Operating weight (lb) 6,750
Width (in) 89.00 Approx. refrigerant charge (lb) 229
Height (in) 93.50 Refrigerant R-410a

Conditions of service
Percent of full load 100% Compressor power (kW) 99.44
Capacity (Tons) 95.72 Total Fan Power (kW) 12.48
Unit power (kW) 111.9 Cooling Efficiency (kW/Ton) 1.169
IPLV.IP (kW/Ton) 0.8566

Evaporator
Fluid Water Leaving fluid temp. (°F) 44.00
Fluid flow rate (USgpm) 229.0 Fouling factor (h·ft²·°F/Btu) 0.000100
Entering fluid temp. (°F) 54.00 Pressure drop (psi/ft.H2O) 5.70/13.1
Fluid freezing point (°F) 32.00

Condenser
Design ambient (°F) 95.0 Altitude (ft) 0.000
Fan Motor Power (kW) (Qty) 1.560 (8)

Electrical characteristics
Unit power supply 400V/3ph/50.0Hz Unit rated load amps 208.0
Control power 115V/1ph/50.0Hz Unit min. circuit ampacity (A) 219.0
Unit max. fuse/HACR CB size (A) 250.0 Comp. rated load amps (A) 44.0(1)
Comp. locked rotor amps (A) 320.0(1)

Notes
- The electrical data is being projected base on 95F ambient - Certified in accordance with the AHRI Air Cooled Water-
temperature, Please consult factory for all other ambient Chilling Packages Using the Vapor Compression Cycle
temperature Certification Program, which is based on AHRI Standard-
- Refrigerant charge may vary. Unit nameplate will show final 550/590(I-P) and AHRI Standard 551/591(SI). Certified units
factory charge. may be found in the AHRI Directory at www.ahridirectory.org.

IPLV.IP Points at Standard AHRI Rating Conditions


% Full load Tons Unit kW Comp. kW Fan kW kW/Ton Ambient(°F)
100% 95.72 111.9 99.44 12.48 1.169 95.0
75% 71.79 66.96 56.39 10.57 0.9327 80.0
50% 47.86 38.31 33.37 4.940 0.8005 65.0
25% 23.93 19.62 18.22 1.400 0.8199 55.0

Standard Equipment
Unit Construction Hermetic Scroll Compresssors
▪ Unit shall be constructed of heavy gauge G90 galvanized steel ▪ Strap on belt type crankcase heater
▪ All sheet metal parts are painted with oven baked epoxy / ▪ Compressor staging on all units
polyester powder paint, sustaining 1000 hour salt spray test in ▪ One (1) year warranty. (Factory provides standard warranty of
accordance with ASTM B-117 12 months from start up or 18 months from shipment date
▪ Control panel IP54 whichever occurs first. Limited to parts replacement only and
excludes freight, taxes/duties, labours, consumable items, etc.
Machine must be well maintained by DB authorized service
representative.)
Air Cooled Condenser Evaporator
▪ Copper tubes ▪ Braze Plate Heat ▪ Plate material AISI 316
▪ Subcooling circuit(s) Exchanger ▪ Fully insulated
▪ Direct drive fans with internal motor protection ▪ Single and True Dual
▪ Standard operation to 45°F ambient using fan cycling Evaporator
▪ Enhanced Aluminium Fins

171115 25-Jun-21 Page 1 of 3 SPEC ver. 7.0, 18809


Project: 111 Consultant: --

Location: Date: 6/24/21 10:48 PM


Tag: CHILLER ACDS-R410A-1
PERFORMANCE SUMMARY
Location:

Refrigeration Specialties
▪ Thermal expansion valve(Standard for ACDS010-080) ▪ Two/Three compressors per refrigerant circuit
▪ Liquid line solenoid valve (Standard with thermal exapansion ▪ Refrigerant charge of R-410A
valve) ▪ Electronic expansion valve (optional for ACDS010-080, standard
▪ Sight glass for ACDS095-175)
▪ Removable core filter/drier(s)
Controls
▪ Micro-Vision Controller ▪ Evaporator fluid freeze protection
▪ Control Power Transformer (TSF) - A transformer is mounted ▪ High and low pressure protection
and wired to provide 115 volt power to control circuit, and ▪ Staggered starting of compressors
crankcase heater(s). This eliminates the need for separate 115 ▪ Anti-recycle timing in controller
volt field wiring for controls. NOTE: Chiller heater is always on ▪ Fan cycling
separate circuit. ▪ Accepts remote start & stop signal
▪ Single and Dual Circuits have Tandem Scroll Compressors Sets ▪ Keyboard accessed LCD readouts, continuously updated
per Circuit ▪ Discharge and suction pressure for all circuits
▪ Two line 16 character alpha numeric display control functions
▪ Compressor loading/staging based on leaving fluid temperature

171115 25-Jun-21 Page 2 of 3 SPEC ver. 7.0, 18809


Project: 111 Consultant: --

Location: Date: 6/24/21 10:48 PM


Tag: CHILLER ACDS-R410A-1
PERFORMANCE SUMMARY
Location:

171115 25-Jun-21 Page 3 of 3 SPEC ver. 7.0, 18809