Teste e Ajustes
D11R Track-Type Tractor Hydraulic System
Número de Mídia -RENR7981-07 Data de Publicação -01/01/2015 Data de Atualização -13/01/2015

i03895923

Pilot System Pressure - Test and Adjust


SMCS - 5050-025-PS ; 5050-081-PS

Always replace the floorplate when performing tests.

Perform tests with oil temperature below 66 deg c (150 deg f) to prevent
serious burns.

Do not hold pressure gauges in your hand or lap when checking


pressure readings.

Introduction
Oil for the pilot system comes from the fan pump and from the resolver network.

Required Tools

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 08/03/2020
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 35... Página 2 de 6

Illustration 1 g01106077

Tooling (A)

Illustration 2 g02087998

(B) 198-4240 Digital Pressure Indicator Gp

Table 1
Tool Item Part Number Description Qty
Pressure Gauge
A1 8T-0855 1
(0 to 4,000 kPa (0 to 580 psi))
Pressure Gauge
A2 8T-0856 1
(0 to 6,000 kPa (0 to 870 psi))
A3 6V-3989 Fitting 1
A4 6V-4143 Quick Connect Coupler 2
A5 177-7860 Hose As (10 ft) 1
B 198-4240 Digital Pressure Indicator Gp 1
B1 198-4234 Digital Pressure Indicator Gp 1

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 08/03/2020
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 35... Página 3 de 6

B2 198-4237 Pressure Sensor 1

0 to 3447 kPa (0 to 500 psi)


B3 198-4236 Adapter Cable As 1

Machine Preparation
1. Move the machine to a smooth horizontal location.

2. Place the steering control lever in the NEUTRAL position.

3. Engage the parking brake.

4. Lower the attachments to the ground.

5. Stop the engine.

6. Turn the key to the ON position, but do not start the engine.

7. Verify that the implement lockout switch is in the UNLOCKED position.

8. Move the control levers through the full range of travel several times. This will relieve any
pressure that may be present in the implement hydraulic system.

9. Make sure that the pressure in the entire hydraulic system has been released.

10. Remove the floorplate from the machine.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 08/03/2020
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 35... Página 4 de 6

Illustration 3 g02100816

Electrohydraulic Valve

(HPS) Pressure tap

(1) Adjustment screw (pilot system)

(2) Adjustment screw (pressure reducing valve)

11. Connect tooling (A2) or (B) to pressure tap (HPS) .

12. Install the floorplate. Make sure that the floorplate does not interfere with the hoses for the
test gauge.

Pilot System (Testing)


1. Start the engine.

2. Run the engine at HIGH IDLE.

3. Warm the hydraulic oil to the operating temperature.

4. The pressure should read 3930 ± 170 kPa (570 ± 25 psi) at pressure tap (HPS) .

Pilot System (Adjusting)

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 08/03/2020
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 35... Página 5 de 6

1. Stop the engine.

2. Turn adjustment screw (1) clockwise in order to raise maximum pressure.

3. Turn adjustment screw (1) counterclockwise in order to lower maximum pressure.

Resolver Network (Testing)


1. Refer to Step 1 through Step 12 in "Machine Preparation".

2. Connect tooling (A1) or (B) instead of tooling (A2) .

3. Run the engine at HIGH IDLE.

4. Warm the hydraulic oil to the operating temperature.

5. Move the blade and the ripper to full RAISE position.

6. Stop the engine and monitor the pressure at pressure tap (HPS). Turn the key to the ON
position in order to activate the electronic controls.

7. Move the bulldozer control lever from NEUTRAL position to RAISE position and hold for
three seconds. This will drain the pilot pressure in the accumulator.

8. Release the bulldozer control lever into NEUTRAL position.

9. The pressure at pressure tap (HPS) should be 2070 ± 150 kPa (300 ± 20 psi).

Resolver Network (Adjusting)


1. Stop the engine.

2. Turn adjustment screw (2) clockwise in order to raise maximum pressure.

3. Turn adjustment screw (2) counterclockwise in order to lower maximum pressure.

4. Remove the test equipment from pressure tap (HPS) .

5. Install the floorplate.

Worksheet
Table 2
D11R Pilot System Pressure (Test)and Resolver Network (Test)
Date Equipment ID Code
Item Specification Actual
Engine speed HIGH IDLE

Pilot System Pressure (Test)


3930 ± 170 kPa (570 ± 25 psi)

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 08/03/2020
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 35... Página 6 de 6

Resolver Network (Test)


2070 ± 150 kPa (300 ± 20 psi)

Direitos Autorais 1993 - 2020 Caterpillar Inc. Sun Mar 8 07:59:32 UTC-0300 2020