Report No.

SLIPL/ 16-17/TE- 0200-1


Issued To: Hitech Scientific Corporation Booking Advice No. : 0200
Civil Engineering Instrumentation. Date of Receiving : 03.02.2017
Chemicals Testing Consulting Test Start Date : 03.02.2017
Test Completion Date: 09.02.2017
NABL Accredited Testing Laboratory &
Date of Report : 09.02.2017
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
Reference No HTSC/16-17/ILC-2 DATE- 02/02/2017
Sample Particulars : A sample of Water was received.
Results
S. No. NAME OF THE TEST OBSERVATION
652

1. CHEMICAL TEST
1 Biological Oxygen Demand ,as per IS 3025 Pt - 44 ,Value in mg/Liter 1.8
2 Chemical Oxygen Demand ,as per IS 3025 Pt - 58 ,Value in mg/Liter 9.60
3 Dissolved Oxygen (D.O.) ,as per IS 3025 Pt - 16 ,Value in mg/Liter 8.9
4 Nitrite, as per IS 3025 Pt - 34 ,Value in mg/Liter 1.24
5 Nitrate, as per IS 3025 Pt - 34 ,Value in mg/Liter 10.50
6 Residual Chlorine, as per IS 3025 Pt - 26 ,Value in mg/Liter 5.40

**********End of Result *********

Checked By Authorized Signatory


Report No. JP/ETTL/ 16-17/TE- 0200-2
Issued To: Hitech Scientific Corporation Booking Advice No. : 0200
Civil Engineering Instrumentation. Date of Receiving : 03.02.2017
Chemicals Testing Consulting Test Start Date : 04.02.2017
Test Completion Date: 06.02.2017
NABL Accredited Testing Laboratory &
Date of Report : 09.02.2017
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
Reference No HTSC/16-17/ILC-2 DATE- 02/02/2017

Sample Particulars : A sample of Steel was received.

Results
S.No. NAME OF THE TEST OBSERVATION
296
1. CHEMICAL TEST
1 Silicon ,as per IS 228 Pt - 8 ,Value in % by Mass 0.25
2 Manganese, as per IS 228 Pt - 2, Value in % by Mass 0.70

**********End of
Result *********

Checked By Authorized Signatory


Report No. JP/ETTL/ 16-17/TE- 0200-3
Issued To: Hitech Scientific Corporation Booking Advice No. : 0200
Civil Engineering Instrumentation. Date of Receiving : 03.02.2017
Chemicals Testing Consulting Test Start Date : 04.02.2017
Test Completion Date: 07.02.2017
NABL Accredited Testing Laboratory &
Date of Report : 09.02.2017
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
HTSC/16-17/ILC-2 DATE- 02/02/2017

Reference No

A sample of Cement was received.

Sample Particulars :

Results
S.No. NAME OF THE TEST OBSERVATION
296
1. CHEMICAL TEST
1 Free Lime Content, as per IS 4032, Value in % 0.67

**********End of
Result *********

Checked By Authorized Signatory


Report No. JP/ETTL/ 16-17/TE- 0200-4
Issued To: Hitech Scientific Corporation Booking Advice No. : 0200
Civil Engineering Instrumentation. Date of Receiving : 03.02.2017
Chemicals Testing Consulting Test Start Date : 04.02.2017
Test Completion Date: 07.02.2017
NABL Accredited Testing Laboratory &
Date of Report : 09.02.2017
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
Reference No HTSC/16-17/ILC-2 DATE- 02/02/2017
A sample of Building Stone was received.

Sample Particulars :

Results
S.No. NAME OF THE TEST OBSERVATION
773

1 . PHYSICAL TEST
1 Strength Properties (24 Hrs. Oven Dry), as per IS 1121 part-1, Value in Kg/cm2 775.66
2 Strength Properties (72 Hrs. Soaked), as per IS 1121 part-1, Value in Kg/cm2 361.39
3 True Specific gravity ,as per IS 1122 2.65
4 Water absorption ,as per IS 1124 ,Value in % 0.59

**********End of Result *********

Checked By Authorised Signatory

Report No. JP/ETTL/ 16-17/TE- 0200-5


Booking Advice No. : 0200
Issued To: Hitech Scientific Corporation Date of Receiving : 03.02.2017
Civil Engineering Instrumentation. Test Start Date : 04.02.2017
Chemicals Testing Consulting Test Completion Date: 04.02.2017
Date of Report : 09.02.2017
NABL Accredited Testing Laboratory &
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
Reference No HTSC/16-17/ILC-2 DATE- 02/02/2017
Sample Particulars : A sample of Rebar Coupler Assembly was received.
Results
S.No. NAME OF THE TEST OBSERVATION
773

1 . PHYSICAL TEST
1 Tensile Strength ,as per IS 16172 ,Value in N/mm² 667.41

**********End of Result *********

Checked By Authorised Signatory

Report No. JP/ETTL/ 16-17/TE- 0200-6


Issued To: Hitech Scientific Corporation Booking Advice No. : 0200
Civil Engineering Instrumentation. Date of Receiving : 03.02.2017
Chemicals Testing Consulting Test Start Date : 03.02.2017
Test Completion Date: 09.02.2017
NABL Accredited Testing Laboratory &
Date of Report : 09.02.2017
Authorized Distributor,, Aimil Limited
B/XI/43-44 , Automobile Nagar, Delhi Byepass,
Jaipur, Rajasthan.
Reference No HTSC/16-17/ILC-2 DATE- 02/02/2017
Sample Particulars : A sample of Ply Strand For Stressed Concrete Size= 15.2 mm was received.
Results
S.No. NAME OF THE TEST OBSERVATION
773

1 . PHYSICAL TEST
1 Tensile Strength ,as per IS 14268 ,Value in N/mm² 253

**********End of Result *********

Checked By Authorised Signatory