You are on page 1of 21

Service Bulletin

Transmittal Information

ACSS Publication Number 8210530-001


ATA Service Bulletin 9029000-34-6002
LYNX® MULTILINK SURVEILLANCE SYSTEM - NGT-9000 TRANSPONDER –
PART NO. 9029000-20000/-40000 – INSTALLS OPERATIONAL SOFTWARE FROM
MASTER MEDIA, PART NO. 9020010-011 FOR RELEASE 4.0 FUNCTIONALITY.
PROPRIETARY NOTICE
THIS DOCUMENT AND THE INFORMATION DISCLOSED HEREIN ARE PROPRIETARY
DATA OF AVIATION COMMUNICATION & SURVEILLANCE SYSTEMS, LLC. NEITHER THIS
DOCUMENT NOR THE INFORMATION CONTAINED HEREIN SHALL BE REPRODUCED,
USED, OR DISCLOSED TO OTHERS WITHOUT THE WRITTEN AUTHORIZATION OF
AVIATION COMMUNICATION & SURVEILLANCE SYSTEMS, LLC.

NOTICE
FREEDOM OF INFORMATION ACT (5 USC 552) AND DISCLOSURE OF CONFIDENTIAL
INFORMATION GENERALLY (18 USC 1905)
THIS DOCUMENT IS BEING FURNISHED IN CONFIDENCE BY AVIATION
COMMUNICATION & SURVEILLANCE SYSTEMS, LLC. THE INFORMATION DISCLOSED
HEREIN FALLS WITHIN EXEMPTION (B) (4) OF 5 USC 552 AND THE PROHIBITIONS OF 18
USC 1905.
IMPLEMENTATION OF THIS SOFTWARE UPDATE DESCRIBED IN THIS SERVICE
BULLETIN INVOLVES CHANGES TO SOFTWARE. THE SOFTWARE REQUIRED TO
EFFECT THIS UPDATE IS COPYRIGHTED BY ACSS. LICENSE TO USE THIS SOFTWARE
TO PERFORM THE MODIFICATIONS SET FORTH IN THIS SERVICE BULLETIN SHALL BE
GRANTED BY ACSS IN ACCORDANCE WITH TERMS AND CONDITIONS TO BE ENTERED
INTO BETWEEN ACSS AND THE CUSTOMER.

EXPORT NOTICE
THESE ITEM(S)/TECHNOLOGY CONTAIN INFORMATION SUBJECT TO U.S.
GOVERNMENT EXPORT CONTROL IN ACCORDANCE WITH THE EXPORT
ADMINISTRATION REGULATIONS (EAR), 15 CFR PARTS 730-774. EXPORT OF THIS DATA
TO ANY FOREIGN COUNTRY OR DISCLOSURE OF THIS DATA TO ANY NON-U.S.
PERSON MAY BE A VIOLATION OF FEDERAL LAW.
THE ECCN IS 7E994.

Copyright © 2021 Aviation Communication and Surveillance Systems, LLC.

SUMMARY
This Service Bulletin gives instructions for the installation of Operational Software from Master Media,
Part No. 9020010-011 with Release 4.0 functionality.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 1 of 21
Service Bulletin
NOTE: The work described in this Service Bulletin can be completed on-board an aircraft or at a
Service Center. For purposes of this Service Bulletin, "Service Center" is defined as an
Authorized Repair Station or other repair shop with the proper equipment and
documentation.
REVISION HISTORY
Revisions to ATA Service Bulletin No. 9029000-34-6002 (ACSS Pub. No. 8210530-001) are
summarized in Table 2 below.

Table 1. Service Bulletin Revisions


Revision Date of Release
Initial Release January 15, 2021
Revision 01 July 30, 2021
Revision 02 December 15, 2022

NOTE: This Service Bulletin obeys ASD-STE100 Simplified Technical English guidelines and ATA
iSpec2200 specifications, wherever practicable.

Table 2. Revision Summary


Revision Page Change Made
01 3, 14 Added information about updating from Release 1.X needs databases re-loaded.
02 1 Updated notices according to the latest standards.
6, 7, 11 Updated contact information.
17 Updated for clarity.
18 Added paragraph for clarity.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 2 of 21
Service Bulletin
1. PLANNING INFORMATION

A. Effectivity
This Service Bulletin is applicable to Lynx NGT-9000, Part No. 9029000-20000/-40000.

B. Concurrent Requirements
If upgrading from Release 1.x, replacement of databases is also required. Databases for
Airport (68DC), Map (72DC), and Terrain (71DC) are available from Jeppesen ®. Refer to
the referenced installation manual for details on obtaining database software and
procedures to load the databases using the MPC (MAT). See Service Letter SL-317.

C. Reason
This Service Bulletin implements software modifications to Lynx NGT-9000.
Release 4.0 software update incorporates the following changes:
• Provide TA Aural Delay 1 second configuration option. When this option is enabled,
Traffic Alert is delayed for one second on aural annunciation and TA discrete outputs.
• MPC tool updates to support new features and new IO interfaces. The tool change
also enables new configuration settings to be seen. There is no need to revisit these
configuration settings because all existing settings are maintained.
• Provide a TCAS Only configuration option. When this option is enabled, all other
NGT-9000 functionality including TAWS, GPS, Transponder, ADS-B In, ADS-B Out,
TIS-B, FIS-B are disabled.
• Support dual external GPS sources, GTN-650/750 control panels, external Radio
Altimeters.
• Updates the GPS/UAT module to address a date determination (GPS Epoch)
problem that will occur in 2038. There is no benefit now, but after 2038, this will
enhance the FIS-B reporting.
• Improved TCAS/TAS processing for Helicopter applications.
• Provide an option to enable fault logging while on-ground.

D. Description
This Service Bulletin gives instructions for installing Operational Software from Master
Media, Part No. 9020010-011 by final Acceptance Test on a Manual Test Station (MTS) to
update the Lynx NGT-9000, Part No. 9029000-20000/-40000 with Release 4.0 functionality.
After installation and verification that the software installed successfully, the Media
Identification Label on the front of the unit must be changed to show Software Release 4.0.
The Airworthiness Analysis is not changed.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 3 of 21
Service Bulletin
E. Compliance
The work referred to in this Service Bulletin is recommended when the component is
returned to a Service Center for inspection, test, or repair.
The work referred to in this Service Bulletin is optional, based on individual operator
requirements, when the component is on the aircraft. If the installation is on a rotorcraft with
TAS/TCAS option enabled, TAS/TCAS processing is enhanced. For all aircraft, a GPS
Epoch change is included which will not be useful until 2038.

F. Approval
This Service Bulletin contains no modification information that revises the approved
configuration and therefore does not require governmental or other regulatory agency
approval.
After completing this modification, it is the responsibility of the aircraft operator to get “Return
to Service” authorization, if necessary, from the applicable regulatory authorities.

G. Manpower
A total of 0.5 man-hours are necessary for this upgrade, divided into two tasks:
Approximately 0.25 man-hours are necessary when this modification is completed at a
Service Center or on-board an aircraft. An additional 0.25 man-hours are necessary to
complete manual test procedures and final test of the unit.

H. Weight and Balance


Not changed.

I. Electrical Load Data


Not changed.

J. Software Accomplishment Summary


Operational software is changed by this conversion/modification.
(1) ACSS Documents Necessary to Complete This Bulletin
(a) The documents that follow must be used if the work referred to in this Service
Bulletin is completed at a Service Center.
• Lynx NGT-9000 Component Maintenance Manual (CMM), ACSS Pub No.
0040-17002-01.
(b) The documents that follow must be used if the work referred to in this Service
Bulletin is completed on-board the Aircraft or on a Bench System.
• Lynx NGT-9000 Installation Manual (SDIM), ACSS Pub No. 0040-17001-01.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 4 of 21
Service Bulletin
(c) If modifications are completed on a bench system, use the necessary Test
Program Software identified in Table 3 below (subsequent software revisions are
permitted).

Table 3. Test Program Software


Title Document Number Revision
Test Software (Windows 7 or after) 9002184-001 P (or after)
(ACSS Service Center Only)
FAT Configuration File (Refer to Note 1) 9002182-001 AL (or after)
(ACSS Service Center Only)
Maintenance PC (MPC) (Laptop Computer) 8010-17002-0400 A (or after)
Application Tool (MAT) (Refer to Note 2)
NOTES:
1. Software FAT Configuration File, Part No. 9002182-001, Revision AL (or after) is necessary if you have
Part No. 9002184-001, Revision P (or after) installed on the EITS, Part No. 9002100-001.
2. Lynx MPC Maintenance Application Tool (MAT) P/N 8010-17002-0400. The MPC is compatible with older
system software. Older versions of the MPC (MAT) will not work with newer system software versions.

(d) The necessary ACSS Service Center Test Documents are identified in Table 4
below.

Table 4. Test Documents


Document Number Title Revision
8002500-051 MLT NGT-9000 Acceptance Test AA (or after)
Procedure ATP
8009533-001 NGT-9000 and Appliance Final K (or after)
Acceptance Test Procedure

K. Publications Affected
Because of this Service Bulletin, ACSS will revise the documents in the list that follows:
• Lynx NGT-9000 Component Maintenance Manual (CMM), ACSS Pub No. 0040-
17002-01
• Lynx NGT-9000 Installation Manual (SDIM), ACSS Pub No. 0040-17001-01.

L. Interchangeability
Not applicable.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 5 of 21
Service Bulletin
2. MATERIAL INFORMATION

A. Material – Price and Availability


Equipment Operators Catalog Price Availability
FOC FOC 2 weeks after receipt of
order

NOTE: For additional pricing information, refer to Section 2.B, Industry Support
Information, on Page 7.
(1) Uploading software for on board an aircraft upgrade:
Software is available on the ACSS Publications website. If you have access to the
ACSS Technical Publications website go to
https://support.acsscustomerservices.com/ACSS/support.aspx to download the
following files:
• For the system software release, go to Publications > Lynx 9000 SW > Lynx 9000
SW Release 4 and download the zip file.
• For the MPC and Lynx USB Driver, go to Publications > MPC Tool and download
the mpc4_00.zip file.
If you do not have access, select the “Request Account Button” and fill out the form.
After completing the form press Submit.
NOTE: If you cannot access the software or databases, please contact ACSS via
phone (country code +011) (623) 445-7070 option 3 or via email at
acss.techsupport@l3harris.com.
(2) Placing an Order
(a) If sending units into ACSS, use a standard Purchase Order (PO) form, or
complete the ACSS Service Bulletin Materials Order Form (OA-009) shown on
Page 7. To expedite your order, include all of the information in the list that
follows:
• A Purchase Order Number
• Reference to this Service Bulletin: ATA Service Bulletin No. 9029000-34-6002
(ACSS Publication No. 8210530-001)
• Aircraft Type
• Unit Original Part Number
• Unit Serial Number(s)
• Price of modification for each unit
• Part number(s) being ordered (Refer to Table 5 on Page 9 for a list of part numbers
and order only those parts that are applicable to the unit to be updated.)
• Quantity ordered

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 6 of 21
Service Bulletin
• Bill-to address/instructions
• Ship-to address/instructions
• Freight carrier account number and special shipping instructions, if necessary.
When sending units to an ACSS Service Center, send Purchase Orders to:
A Aviation Communication & Surveillance Systems (ACSS)
Attn: Repair & Overhaul
5353 52nd Street SE
Grand Rapids, Michigan 49512
Phone: (623) 445-7030
Fax: (623) 445-7002
or Email: acss.phxrepair@L3Harris.com

B. Industry Support Information


ACSS’s on-line electronic system gives customers access to a variety of product-related
publications, including Service Bulletins and Technical Newsletters. Go to the ACSS
Customer Services web site at:
https://support.acsscustomerservices.com/ACSS/support.aspx.
(1) Modification at an ACSS Authorized Repair Station:
This Service Bulletin will be completed at no cost (FOC) to the Operator.
(2) Modification by a non-ACSS Repair Shop with Proper Equipment and Documentation:
This Service Bulletin has no cost (FOC) to the Operator. Labor hours will not be
reimbursed. For Material – Price and Availability, refer to Section 2.A on Page 6.
Pricing for this Service Bulletin is applicable to those customers who use on-board data
loading or their own shop procedures to complete this upgrade.
NOTE: A shop Bench Test Fee is applicable for those units sent to ACSS for this
upgrade and will be based on current catalog pricing.
NOTE: Other repairs will be quoted separately. Please speak or write to an ACSS
Customer Order Administrator and request scheduling information before sending
a unit for repair or modification.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 7 of 21
Service Bulletin
ACSS SERVICE BULLETIN
MATERIALS ORDER FORM
To secure the rights to use ACSS software, ACSS requires the completion of a Software License Agreement and Appendix.
If a current Software License Agreement exists with ACSS, the customer is only required to sign an Appendix to the
Agreement for the software being ordered. Based on the information in this order form, ACSS Order Administration will
complete the Appendix and/or the Software License Agreement and forward it to the customer for signatures.
The Software License Agreement, or Appendix, must be signed and received by ACSS prior to shipment of the order.
ALL of the following information MUST be completed for ACSS to quickly and efficiently process this software order.

Customer Name * Customer Purchase Order Number Date

Unit Original Part Number Customer Contact Name Customer Contact Email Address

A/C Type Applicable ACSS Service Bulletin Pub. No. Price of Modification for each Unit

Unit Serial Number(s) Attach additional sheets as necessary to list all of the serial numbers being updated by this software order.

* This completed form can be used as the formal Purchase Order (PO) or can be used as an information sheet attached to the PO.

PARTS BEING ORDERED (as listed in the applicable Service Bulletin section, ‘Material Necessary for Each Component’)

Part Number Description Quantity

NOTE: Each Compact Flash Card/Diskette can do an unlimited number of upgrades. Please order a minimum quantity to meet your needs.

BILL TO ADDRESS SHIP TO ADDRESS

Freight Carrier and Account Number Special Shipping Instructions


SUBMIT THIS ORDER TO: Aviation Communication & Surveillance Systems (ACSS), LLC
Attn: Customer Order Administration
19810 North 7th Avenue
Phoenix, AZ 85027-4741, USA
Phone: 623.445.7040
Fax: 623.445.7004
Email: acss.orderadmin@L3Harris.com

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 8 of 21
Service Bulletin
C. List of Components
(1) Material to be Purchased
The items identified in Table 5 below are necessary to complete this Service Bulletin at
ACSS Service Center.

Table 5. Material to Be Purchased


New Old Instructions/
Keyword Qty
Part Number Part Number Disposition
9020010-011 Master Media Software, CD N/A A/N 1, 2, 5
9002182-001, FAT Configuration Software File, N/A A/N 1, 2, 5
Revision AL (or CD (if necessary)
after)
9002041 Media Identification Label (for use N/A 1 1, 3, 4, 6, 7
at an Authorized Service Center
only)
A/N = As Necessary
N/A = Not Applicable

INSTRUCTIONS/DISPOSITION
1. For correct disposal of used parts, refer to the local regulatory agency or local Service Center policy.
2. This item is necessary when this Service Bulletin is completed at a Service Center.
3. Make sure quantities are correct and verifiable.
4. Include a full list of serial numbers for the units to be modified to make sure you receive the correct
identification plates.
5. Each Compact Flash Card (CF), Floppy Diskette, or Compact Disc (CD) can install an unlimited number
of upgrades. Order a minimum quantity to satisfy your needs.
6. Labels are made of white polyester material.
7. Full labels can only be installed at an Authorized Service Center.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 9 of 21
Service Bulletin
(2) Material Supplied by the Operator

WARNING
BEFORE USING A MATERIAL, REFER TO THE
MANUFACTURER’S MATERIAL SAFETY DATA SHEETS FOR
SAFETY INFORMATION. SOME MATERIALS CAN BE
DANGEROUS.

CAUTION
DO NOT USE MATERIALS THAT ARE NOT EQUIVALENT TO
MATERIALS SPECIFIED BY ACSS. MATERIALS THAT ARE NOT
EQUIVALENT CAN CAUSE DAMAGE TO THE EQUIPMENT AND
CAN VOID ANY WARRANTY.

The items identified in Table 6 below are commercially available. Do not order them as
part of this Service Bulletin. Equivalent alternatives are permitted for items in the table.

Table 6. Operator Supplied Material


Part/Specification Number Qty Keyword
APN 11-136-78 A/N Solvent, isopropyl alcohol (99%) - Optional source
HAZARD CODE 230D
Label A/N Avery® 5428, label size 0.5 H x 1.0 W inch
Optional A/N USB Cable, micro to standard
A/N = As Necessary

D. Subcomponents to be Re-Identified
Not applicable.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 10 of 21
Service Bulletin
E. Tooling
The items identified in Table 7 below are necessary to do the procedures in this Bulletin.
Equivalent alternatives are permitted for items in the table.

Table 7. Tooling
Part/Specification Number Qty Description
Method 1 –Software Verification using the MPC Maintenance Application Tool (MAT)
file name mpc4_00.zip
Optional PC A/N Maintenance Computer (MPC), laptop to operate the
Maintenance Application Tool (MAT) for system.
Windows 7, 8 or 10 prefered, 1.3 GHz processor or
greater, 5121 MB or more RAM, USB connection.
8010-17002-0400 (Note 1) A/N Maintenance Application Tool (MAT) (included with
Release CD or web download).
8010-17010-0001 A/N USB Driver for Windows 7, 8, or 10.
A/N = As Necessary

NOTES:

1. The MAT tool can be downloaded from the ACSS Publications website at
https://support.acsscustomerservices.com/ACSS/support.aspx. For the MPC and Lynx USB
Driver, go to Publications >MPC Tool and download the latest mpc zip file.

F. Special Tools
Not applicable.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 11 of 21
Service Bulletin
3. ACCOMPLISHMENT INSTRUCTIONS

A. General

WARNING
ALL DISASSEMBLY AND MODIFICATION PROCEDURES AT A
SERVICE CENTER MUST BE COMPLETED AT AN ANTISTATIC
WORKSTATION. REFER TO ESTABLISHED ANTISTATIC
PROCEDURES.

CAUTION
THIS EQUIPMENT CONTAINS MOISTURE SENSITIVE PARTS.
SPECIAL HANDLING IS NECESSARY.

NOTE: The Paragraph, Item, Table, and/or Figure numbers referred to in this Service
Bulletin can be found in the documents that follow:
• Lynx NGT-9000 Component Maintenance Manual (CMM), ACSS Pub No.
0040-17002-01
• Lynx NGT-9000 Installation Manual (SDIM), ACSS Pub No. 0040-17001-01.
NOTE: Before doing the work in this Service Bulletin, make sure the installed software
part number is readable in the Lynx NGT-9000 from the maintenance connection.

B. Preparation
(1) Choose a Verification Method.
Before starting this upgrade, use the method(s) in this section to make sure that the
current software part numbers are readable. If the method gives a satisfactory result,
use that method to read the part number(s) after the software is installed.

CAUTION
THE AIRCRAFT MUST HAVE GEAR DOWN AND “WEIGHT
ON WHEELS” DURING VERIFICATION OF THE
OPERATIONAL SOFTWARE PART NUMBER OR WHILE
REPROGRAMMING THE LYNX NGT-9000 ON-BOARD THE
AIRCRAFT.

CAUTION
DO NOT START A SYSTEM POWER CYCLE WHILE
REPROGRAMMING THE LYNX NGT-9000. THIS CAN CAUSE
A PROGRAMMING FAILURE.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 12 of 21
Service Bulletin
Method 1. Software Verification using the MPC Maintenance Application
Tool (MAT) (On-Wing)
NOTE: The Zadig utility must be installed on the MPC in order for the MPC
and Lynx NGT-9000, to establish communication. Details are provided
in the referenced installation manual.
1) If the MPC has not been previously installed, the Zadig utility must be
installed on the laptop in order for the MPC, to establish communication.
Details are provided in the referenced installation manual.
2) Cycle power to the Lynx NGT-9000.
3) After the unit restarts, connect the unit to the MPC (maintenance mode).
4) From the MPC left panel, select “Connect, NGT-9000, USB”.
5) From the MPC select “Info, Versions, Software”.
6) Make sure you can read the software part numbers.
7) After the new loaded software is installed, make sure the software part
numbers agree with the part numbers listed in Table 8 on Page 17. If the
software is not correct, press the refresh button and check again. If
information continues to be incorrect, cycle power to the unit and check
again.
Method 2. Software Verification When Only a MSS Test system is Used
(Service Center)
8) If an upgraded MSS Test System is used to install this modification, the
correct Test Software must be installed.
9) Refer to the TESTING AND FAULT ISOLATION section of the Lynx NGT-
9000 Component Maintenance Manual (CMM), ACSS Pub No. 0040-17002-
01 for test procedure information.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 13 of 21
Service Bulletin
C. Modification Procedure – On-board the Aircraft or On a Bench System
NOTE: If upgrading from Release 1.x, refer to the Concurrent Requirements in Section
1.B on Page 3 for database re-loading.

CAUTION
THE AIRCRAFT MUST HAVE GEAR DOWN AND “WEIGHT ON
WHEELS” DURING VERIFICATION OF THE OPERATIONAL
SOFTWARE PART NUMBER OR WHILE REPROGRAMMING THE
LYNX NGT-9000 ON-BOARD THE AIRCRAFT.

CAUTION
DO NOT START A SYSTEM POWER CYCLE WHILE
REPROGRAMMING THE LYNX NGT-9000. THIS CAN CAUSE A
PROGRAMMING FAILURE.

NOTE: Before starting this modification, use the Software Verification Methods chosen in
Section 3.B(1) on Page 12 to make sure the installed software part numbers are
readable. This step is for method validation only, and not intended for part
number verification. Part number verification is completed after the software is
installed.
NOTE: Due to the long loading times for the software provide external power to the
aircraft during the loading procedures.
NOTE: Details on the operation of the MPC (MAT) are provided in the Lynx NGT-9000
Installation Manual (SDIM), ACSS Pub No. 0040-17001-01.
(1) Install the Software
NOTE: Software used by the Lynx NGT-9000 is packaged in a zip file. Create a
folder named “Lynx 4 SW” on the MPC. Download the zip files and store in
the folder. Unzip the file in this folder.
NOTE: The upgrade to this software also allows a number of new interfaces to be
possible, viewable through the configuration settings. There is no need to
revisit these configuration settings because all existing settings are
maintained and the new interfaces are not active.
(a) Install the MPC (MAT), (mpc4_00.zip) Part No. 8010-17002-0400 per the Lynx
NGT-9000 Installation Manual (SDIM), ACSS Pub No. 0040-17001-01.
(b) Apply power to the Lynx NGT-9000 using applicable essential or emergency
electrical buses. Normal operation begins within 10 seconds.
(c) Use an USB Cable to connect the MPC to the Lynx NGT-9000.
(d) Open MPC (MAT) on the MPC.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 14 of 21
Service Bulletin
(e) In the MPC (MAT) window, select Connect, NGT9000, USB.
NOTE: Communication is established when the MPC (MAT) left view panel
changes from grey to tan and the message “Connected” is shown in
the lower communication bar. Communication begins with the unit in
Flight mode as indicated by the (Flight) message in the panel and at
the bottom status bar.
(f) From the MPC (MAT) left panel, select Service, Restart Unit. The Restart Unit
right panel opens.
(g) From the Restart Unit right panel, select Maintenance (No WiFi). Click on “Restart
Unit” at the bottom of the panel. Click “Yes” to confirm. Click “Ok” when prompted
by the “Restart request succeeded. Please reconnect” message.
NOTE: Not connected shows at the bottom.
(h) From the MPC (MAT) left panel, select Connect, NGT9000, USB.
NOTE: The unit is ready when the maintenance screen is shown on the unit
display and Maintenance mode is indicated by the (Maint) message in
the panel and at the bottom of the status bar, and shows connected.
(i) From the MPC (MAT) left panel, select Update, Load Software. See Figure 1
below.
NOTE: Do not remove power to the unit or disconnect the MPC during this
procedure.

Figure 1. MPC (MAT) Menu

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 15 of 21
Service Bulletin
(j) Under the “NGT-9000 Software Package File”, click on “Browse” and browse to
the Lynx 4 SW folder. Select “ngtSW.pkg” and click “Open”. The MPC (MAT)
verifies the contents of the file to be loaded. Click “Upload”. The Warning
message shows, click ”Yes”.
NOTE: A progress bar showns the software load. The “NGT-9000 software
package upload complete” message shows when the procedure has
finished.
NOTE: DO NOT leave this page until the “upload complete” message shows
or the upload will cancel.
NOTE: If a problem loading the Software Package is detected a failure
message shows. Check that the file is correct and try the procedure
again. If the problem continues, cycle unit power and try again.
(k) A Upload Complete message show and promps a restart. Click “Ok” to confirm
the restart.
NOTE: Not connected shows at the bottom.
(l) In the MPC (MAT) window, select Connect, NGT9000, USB.
NOTE: Communication is established when the MPC (MAT) left view panel
changes from grey to tan and the message “Connected” is shown in
the lower communication bar. Communication begins with the unit in
maintenance mode as indicated by the (MAINT) message in the panel
and at the bottom status bar.
(m) From the MPC (MAT) left panel, select Update, Load Software. See Figure 1.
NOTE: Do not remove power to the unit or disconnect the MPC during this
procedure.
(n) Under the “GPS/UAT CCA Composite Binary”, click on “Browse” and browse to
the Lynx 4 SW folder. Select “UAT-MSS.bin” and click “Open”. The MPC (MAT)
verifies the contents of the file to be loaded. Click “Upload”. The Warning
message shows, click ”Yes”.
NOTE: Two consecutive progress bars show the software has loaded. The
“UAT/GPS CCA FPGA uploaded” message shows when the procedure
has finished.
NOTE: DO NOT leave this page until the “upload complete” message shows
or the upload will cancel.
NOTE: If a problem loading the Software Package is detected a failure
message shows. Check that the file is correct and try the procedure
again. If the problem continues, cycle unit power and try again.
(o) A Upload Complete message show and promps a restart. Click “Ok” to confirm
the restart.
NOTE: Not connected shows at the bottom.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 16 of 21
Service Bulletin
(p) Externally cycle power to the unit. Allow 15 seconds for unit to power on.
(q) After the unit restarts, in the MPC (MAT) menu, select Connect, NGT9000, USB.
NOTE: Communication is established when the MPC (MAT) left view panel
changes from grey to tan and the message “Connected” is shown in
the lower communication bar. Communication begins with the unit in
Flight mode as indicated by the (Flight) message in the panel and at
the bottom status bar.
(r) From the MPC (MAT) left panel, select Service, Restart Unit. The Restart Unit
screen opens.
(s) From the Restart Unit screen, select Maintenance (No WiFi). Click on “Restart
Unit” at the bottom of the main screen. Click “Ok” when prompted to “Restart
request succeeded. Please reconnect”.

D. Close-Up – On-board the Aircraft or On a Bench System


(1) Complete a Software Verification
(a) Make sure the software is correctly installed. Use the same Software Verification
Method from paragraph 3.B(1) on Page 12 to read the software part numbers.
The list of new software part numbers to be verified is shown in Table 8 below.

Table 8. Viewable Lynx NGT-9000 Software Configuration After This Upgrade


Part Number File Description
8040-17000-0400 ngtSW.pkg
• 8010-17000-0400 Ops SW
• 8010-17001-0400 Maint. Sw
• 8000-17000-0400 Firmware
9021105-013 UAT-MSS-9021105-013
UAT-MSS-9021105-013
• 9021100-012 Appliance Ops S/W
• 9021120-005 Appliance Firmware

(2) Remove power from the Lynx NGT-9000.


(3) Disconnect all interface cable connections.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 17 of 21
Service Bulletin
E. Re-Identification of Equipment – On-board the Aircraft or On a Bench System or at a
Non-Authorized Service Center
NOTE: The software part numbers are stored electronically and is verified with the MPC
(MAT). No external ID is required, but a software label can be used if desired as
detailed below.

WARNING
WHEN HANDLING SOLVENTS, MAKE SURE THERE IS
SUFFICIENT VENTILATION IN THE WORK AREA. USE
APPLICABLE PRECAUTIONS TO PREVENT INHALATION OF
VAPORS OR EXPOSURE OF FUMES TO FLAME.

After modification, the Product Identification Label on the front of the Lynx NGT-9000 can be
updated.
(1) Examine the Identification Label(s) on the front of the Lynx NGT-9000.
(2) Use the steps that follow to replace the entire label. Refer to Table 5 on Page 9 for a
list of applicable labels.
(a) Examine the Identification Label(s) on the front of the Lynx NGT-9000.
(b) If necessary you can affix a new Avery Label. See Figure 2 on Page 20 and
Figure 3 on Page 21 for an example of a generic ACSS Media Identification
Label.
NOTE: Make sure that the label shows Media PNR “9020010-011” and
Release No. 4.0.
(c) Use a utility knife or razor blade and carefully remove the Media Identification
Label.
NOTE: Keep the removed label. Refer to local repair station policy for correct
disposal procedures.
(d) Clean the label area on the Lynx NGT-9000 with isopropyl alcohol and let the
surface dry.
(e) Install the label in the same location as the removed label.
Alternately, if the identification label is not going to be updated with each SW load, this label
can be removed entirely. Follow Steps 3.E(2)(a) thru 3.E(2)(c) to perform this removal.

F. Test – On-board the Aircraft or On a Bench System


Complete the self test to make sure all system parameters operate correctly. Refer to the
approved methods found in the Lynx NGT-9000 Installation Manual (SDIM), ACSS Pub No.
0040-17001-01.
This completes the upgrade of the Lynx NGT-9000, Part No. 9029000-20000/-40000 to Release
No. 4.0.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 18 of 21
Service Bulletin
G. Modification Procedure – At a Service Center
(1) Install the Master Media Software
(a) Procure a copy of the Master Media Software Compact Diskette (CD), Part No.
9020010-011.
(b) Close all running applications on the EITS PC.
(c) Insert the Master Media Software CD into the CD drive of the EITS PC.
(d) Open File Explorer and go to the CD directory.
(e) Copy all files in the CD directory.
(f) Go to File Explorer C:\ACSS\Test Terminal\LRU_Software NGT-9000 drive and
paste the files. Choose “Paste and Replace” when prompted.
(2) Install the FAT Configuration Software (IF NECESSARY)
(a) Use the procedures and instructions in the FAT Calibration, Pub No. 9002182-
001, Revision AL (or after) to complete the software modification described in this
Service Bulletin.

H. Re-Identification of Equipment - At an Authorized Service Center


Update the Media Identification Label on the front of the Lynx NGT-9000. Refer to Table 5 on
Page 9 for a list of part numbers.

WARNING
WHEN HANDLING SOLVENTS, MAKE SURE THERE IS SUFFICIENT
VENTILATION IN THE WORK AREA. USE APPLICABLE
PRECAUTIONS TO PREVENT INHALATION OF VAPORS AND
EXPOSURE OF FUMES TO FLAME.

(1) Examine the Identification Label(s) on the front of the Lynx NGT-9000.
(2) Use the steps that follow to replace the entire label. Refer to Table 5 on Page 9 for a
list of applicable labels.
(a) Examine the Identification Label(s) on the front of the Lynx NGT-9000.
(b) Procure a new preprinted Media Identification Label. See Figure 2 and Figure 3
on Page 21 for an example of a generic ACSS Media Identification Label.
NOTE: Make sure that the label shows Media PNR “9020010-011” and
Release No. 4.0.
(c) Use a utility knife or razor blade and carefully remove the Media Identification
Label.
NOTE: Keep the removed label. Refer to local repair station policy for correct
disposal procedures.

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 19 of 21
Service Bulletin
(d) Clean the label area on the Lynx NGT-9000 with isopropyl alcohol and let the
surface dry.
(e) Install the label in the same location as the removed label.

I. Test - At a Service Center


(1) Use the Lynx NGT-9000 Component Maintenance Manual (CMM), ACSS Pub No.
0040-17002-01 to complete a Final Test and make sure all system parameters are fully
functional. Refer to the procedures and instructions in the Acceptance Test Procedure,
Pub No. 8002500-051, AA (or after) and Acceptance Test Procedure Pub No.
8009533-001, Revision K (or after).

J. Close-up
This completes the upgrade of the Lynx NGT-9000, Part No. 9029000-20000/-40000 to
Release No. 4.0.

Figure 2: Panel Mount Label Placement

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 20 of 21
Service Bulletin

Figure 3: Remote Mount Label Placement

Release Date: January 15, 2021 ATA Service Bulletin No. 9029000-34-6002
Revision 02: December 15, 2022 ACSS Publication No. 8210530-001
ACSS Use or disclosure of the information on this sheet is subject to
Proprietary the proprietary and export notices on the title page. Page 21 of 21