You are on page 1of 2

Nr

DATA SHEET I-FD-3010.92-5121-600-SMN-001


CLIENT: SHEET
GUARA E&P 1 of 2

B.V.
PROGRAM:
PRESALT FPSOs – HULL
AREA:
PETROBRAS 66 (P-66)
TITLE:
ENGENHARIA SEAWATER ELECTROLYZER DATA SHEET - CORPORATE
IEEPT/IEPSA E-UE-5121501 IEPSA
REFERENCE NUMBER: TECHNICAL RESPONSIBLE: CREA NUMBER:

ASAFE RIBEIRO DE MORAIS 5063341480


SIEMENS CONTRAC NUMBER: MAGNETIC ARCHIVE: MICROSOFT EXCEL 2000

35000000001.10.2 I-FD-3010.92-5121-600-SMN-001_C.xls

REVISION INDEX

REV. DESCRIPTION AND/OR REVISED SHEETS

0 ORIGINAL ISSUE

A ACCORDING TO ADF ADF-00000-P01197_66-93-1405-A

B CHANGES ACCORDING TO ADF-00000-P01197/66-93-2000_A

C RELEASED. DOCUMENT FOR WORKING OR CONSTRUCTION ACCORDING TO ADF-00000-P01197/66-93-3416_A

REV. 0 REV. A REV. B REV. C REV. D REV. E REV. F REV. G REV. H


DATE 23/11/2012 26/03/2013 01/07/2013 14/04/2016
PROJECT P66 P66 P66 P66
EXECUTION GUSTAVO GUSTAVO GUSTAVO LUCAS
CHECK SCARCELLI SCARCELLI SCARCELLI SCARCELLI
APPROVAL HARADA HARADA HARADA ASAFE
Nr REV.
DATA SHEET I-FD-3010.92-5121-600-SMN-001 C
SHEET
GUARA PETROBRAS 66 (P-66) 2 of 2
TITLE:
B.V. SEAWATER ELECTROLYZER DATA SHEET - CORPORATE
E-UE-5121501 IEPSA
1 GENERAL
2
3
4 Flowrate of water to be treated 850 - 3900 m³/h
5 No of electrolysers 2 unit of 100%
6 Model Number 2 Modules of 16 Cells
7 Layout In Series
8 Chlorine Production per Electrolyser 11,99 kg/h
9 Total Chlorine Production 11,99 kg/h
10 Seawater flow per Module 5,5 m³/h
11 Total seawater flow rate (1) 11 m³/h
12 Produced Hypochlorite Concentration 1064 mg/l at 11,99 kg/h production
13
14
15 OPERATING CONDITIONS
16
17 Inlet Pressure 628 kPa
18 Operating Pressure 628 kPa
19 Max Operating Pressure (4) 853 kPa
20 Equipment Design Pressure 1000 kPa
21 Seawater Inlet Operating Temp. 19 - 28 °C
22 Design Temperature (Mechanical) 55 °C
23 Equipment Design Temperature 55 °C
24 Chloride Content 19,75 g/l
25
26
27 CONSTRUCTION
28
29 Design Safe
30 Type of Cells M K II M
31 Enclosure Protection IPW56
32
33
34 MATERIAL
35
36 Anode -base Titanium to ASTM 337 and 338 Gr 2
37 -coating Pt. Proprietary
38 Cathode -base Titanium to ASTM 337 and 338 Gr 2
39 -coating None
40 Piping ABS - ASTM D2996/F1173
41 Seals Peroxide cured EPDM, ASTM D-200
42
43 Enclosure SS316
44
45 ANODE LIFE
46
47 Expected 7 years
48 Guaranteed 5 years
49
50 INSPECTION
51
52 Hydrotest 1000 kPa
53
54 NOTES
55 1. TOTAL SEAWATER THAT GOES THROUGH ELECTROLYZERS
56 2. FOR PAINTING, PLEASE REFER TO PAINTING SPECIFICATION - I-ET-3010.92-5121-956-SMN-001
57 3. FOR INSPECTION AND TESTS, PLEASE REFER TO ITP SPECIFICATION - I-ET-3010.92-5121-970-SMN-001
58 4. ONLY IN CASE OF INLET SEAWATER PRESSURE CONTROL VALVE FAILURE