PERRY JOHNSON LABORATORY

ACCREDITATION, INC.

Certificate of Accreditation
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:

Sistemas de Medición Meril, S.A. de C.V.


Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070

(Hereinafter called the Organization) and hereby declares that Organization is accredited
in accordance with the recognized International Standard:

ISO/IEC 17025:2017

This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system
(as outlined by the joint ISO-ILAC-IAF Communiqué dated April 2017):

Dimensional, Mechanical, Mass, Force and Weighing Devices, Thermodynamic


and Electrical Calibration
(As detailed in the supplement)

Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this
certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the
Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules.

For PJLA:
Initial Accreditation Date: Issue Date: Expiration Date:
December 19, 2011 January 18, 2022
April 30,
Tracy 2024
Szerszen
President/
Accreditation No.: Certificate No.:
Perry Johnson Laboratory 70613 L22-51
Accreditation, Inc. (PJLA)
755 W. Big Beaver, Suite 1325 The validity of this certificate is maintained through ongoing assessments based
Troy, Michigan 48084 on a continuous accreditation cycle. The validity of this certificate should be
confirmed through the PJLA website: www.pjlabs.com
Page 1 of 8
Certificate of Accreditation: Supplement
ISO/IEC 17025:2005 and DoD-ELAP

Laboratory Name
8100 Address Drive, City, ST 99999
Accreditation is granted to the facility to perform the following testing:

Issue: 10/10 This supplement is in conjunction with certificate #L10-171-R1 Page 2 of 8


Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Manuel Rodriguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:

Dimensional
MEASURED INSTRUMENT, RANGE OR NOMINAL DEVICE CALIBRATION CALIBRATION
QUANTITY OR GAUGE SIZE AS APPROPRIATE AND MEASUREMENT EQUIPMENT AND
CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
CMM – Verification X= Up to 1 530 mm (1.29+ 1.84 x 10-3L) µm Check Master mm
Volumetric Diagonal and Y= Up to 1 530 mm Ceramic Ball 20 mm
Length. X, Y, ZO Z= Up to 1 530 mm ISO-10360-2
Volumetric Diagonal = NMX-CH-10360-2-IMNC
Up to 1 530 mm SMMD-010

Probing ErrorsO 20 mm 1.2 µm


CalipersO Up to 1 010 mm (15.99 + 1 x 10-3L) µm Check Master mm
JIS B 7507
NMX-CH-002-IMNC
SMMD-002
Optical Systems X: up to 300 mm (0.999 + 9 x 10-3L) µm Ruler Glasses mm
Only Linear Movement Y: up to 300 mm Gages Blocks
X, Y, Z AxisO Z: up to 220 mm SMMD-012
Optical Comparator Ruler Glasses mm
X axis Linearity Up to 300 mm (0.999 + 9 x 10-3L) µm SMMD-005
Y axis LinearityO Up to 300 mm (0.999 + 9 x 10-3L) µm
Optical Comparator Up to 180° 0.03° Angle Reticule
AngleO SMMD-005
Optical Comparator 10X 0.05 % of magnification Magnification Check
MagnificationO 20X 0.02 % of magnification Scale
SMMD-005
50X 0.02 % of magnification
62.5X 0.02 % of magnification
Optical Comparator 76.2 mm of Y axis travel 2.5 µm Cylindrical Square
Squareness of or maximum Y axis travel SMMD-005
Y axis to X axisO if maximum is less than
76.2 mm
(3 in of Y axis travel or (100 µin)
maximum Y axis travel if
maximum is less than 3 in)
MicrometersF 0.5 mm to 100 mm (7.98 x 10-1 + 3.02 x 10-2L) µm Set Gage Blocks Grade 0
NMX-CH-099,
SMMD-001
Dial and Digital 0.001 mm to 50 mm (7 x 10-1 + 8 x 10-3L) μm Micrometer Head res
IndicatorsF (Res.= 0.001 mm) 0.0001 mm,
JIS B 7503, JIS B 7533,
ISO 13102
NMX-CH-036
NMX-CH-149
SMMD-003

Issue 01/2022 This supplement is in conjunction with certificate #L22-51 Page 3 of 8


Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Ing. Manuel Rodríguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:


Dimensional
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Master BlockF 0.5 mm to 100 mm (0.1 + 0.05L) μm Gage Blocks, Grade 0
Gage Block Comparator
NMXCH-3650
SMMD-013
Surface Plate 0.01 mm 3.5 µm Mu-Checker Digital
Repeat Reading O NMX-CH-8512-IMNC
SMMD-007
Height GagesF 10 mm to 1 010 mm (8.1 + 8 x 10-4L) μm Check Master
Linear Height GagesF 10 mm to 1 010 mm (2.2 + 1.7 x 10-3L) μm JIS B 7517
NMX-CH-141-IMNC
SMMD-004
Roughness MeterF Roughness Specimen
Ra 2.94 um 0.036 µm Ra, Ry
Ry 9.3 um ISO-12179
SMMD-006
Pin GagesF 0.3 mm to 25.4 mm (2.39 x 10-1 + 4.1 x 10-3L) µm Micrometer Laser Digital
Class Z, ZZ, X, XX Up to 600 mm (2.39 x 10-1 + 4.1 x 10-3L) µm Unidimensional CMM
(Res.= 0.01 µm)
ASME B 89 1.5
SMMD-009
Ring GaugeF 1 mm to 100 mm (0.53 + 4 x 10-3L) µm Unidimensional CMM
(Res.= 0.1 µm)
Gauge Block Grade K
Ring MasterF 1 mm to 480 mm 1.4 µm Unidimensional CMM
(Res.= 0.1 µm)
Gauge Block Grade K
SMMD-018, SMMD-016
Dial and Digital 0.001 mm to 101.6 mm (1.1 + 2 x 10-3L) µm Unidimensional CMM
IndicatorF (Res.= 0.001 mm) (Res.= 0.1 µm
JIS B 7503, JIS B 7533,
ISO 13102
NMX-CH-036
NMX-CH-149
SMMD-003
SMMD-015
SpheresF Up to 100 mm (0.53 + 4 x 10-3L) µm Unidimensional CMM
(Res.= 0.1 µm)
ASME B89.1.5
SMM-020
Roalling BearingsF Up to 480 mm (0.53 + 4 x 10-3L) µm Unidimensional CMM
(Res.= 0.1 µm)
Gauge Block Grade K ISO
3290-1 and 2
SMM-019
Inductive IndicatorF Up to 101.6 mm (0.53 + 4 x 10-3L) µm Unidimensional CMM
Issue 01/2021 This supplement is in conjunction with certificate #L22-51 Page 4 of 8
Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Ing. Manuel Rodríguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:


(Res.= 0.000 1 mm) (Res.= 0.1 µm)
Plug Gage Up to 480 mm (0.53 + 4 x 10-3L) µm SMMD-022, SMMD-013
Go, No GoF SMMD-024, SMMD-025
SMMD-026

Dimensional
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Gage BlockF Up to 600 mm (0.53 + 4 x 10-3L) µm Unidimensional CMM
Micrometer HeadsF Up to 50 mm (0.53 + 4 x 10-3L) µm (Res.= 0.1 µm)
(Res.= 0.000 1 mm) SMMD-022, SMMD-013
Inside MicrometerF Up to 480 mm (0.53 + 4 x 10-3L) µm SMMD-024, SMMD-025
SMMD-026
Bore GaugeF Up to 480 mm (0.53 + 4 x 10-3L) µm
Graduated RulesF 5 mm to 3 000 mm (123 + 0.2L) μm Gauge and Vision
NMX-CH-148-IMNC
SMMD-017
PCMM Up to 1 500 mm (4.5 + 7L) µm Gage Blocks, Step Gage
Volumetric Performance Calibrated Sphere
PCMM Sphere Diameter 2 µm ASME B89.4.22
Effective Diameter 20 mm B89.4.22
Fixed Point CalibrationFO SMMD-014

Mechanical
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Indirect Verification of 40 HRB to 60 HRB 1.1 HRB Block Gage HRB
Rockwell Hardness 61 HRB to 80 HRB 0.64 HRB ASTM E18
Machines HRBO SMMFA-002
81 HRB to 100 HRB 0.46 HRB
Indirect Verification of 20 HRC to 39 HRC 0.37 HRC Block Gage HRC
Rockwell Hardness 40 HRC to 59 HRC 0.33 HRC ASTM E18
Machines HRCO SMMFA-002
60 HRC to 70 HRC 0.31 HRC
Pressure GaugeFO 3 psi to 300 psi (9.44 x 10-1 + 1.85 x 10-3P) psi Digital Pressure Gage
Crystal
(Res.= 0.01 psi)
NOM-013-SCFI
SMMV-001
500 psi to 5 000 psi (9.82 x 10-1 + 3.6 x 10-5P) psi Digital Manometer
Pressure Pump
(Res.= 1 psi)
NOM-013-SCFI
SMMV-001
Torque MeterFO 0.6 N∙m to 6 N∙m 1 % of reading Digital Torque Tester

Issue 01/2021 This supplement is in conjunction with certificate #L22-51 Page 5 of 8


Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Ing. Manuel Rodríguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:


4 N∙m to 34 N∙m 0.35 % of reading ISO-6789
34 N∙m to 340 N∙m 1 % of reading SMMFA-001

Mass, Force and Weighing Devices


MEASURED RANGE OR NOMINAL CALIBRATION CALIBRATION
INSTRUMENT, DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
QUANTITY OR GAUGE APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
BalancesO 1 mg to 210 g (2 x 10-4 + 7.82 x 10-6Wt) g Mass Set Class
(Res.= 0.1 mg) MASS CLASS F1
40 mg to 2 100 g (1.57 x 10-2 + 3.11 x 10-6Wt) g NOM-010-SCFI
(Res.= 10 mg) SMMM-001
500 mg to 8 100 g (1.5 x 10-1 + 2.2 x 10-4Wt) g Mass Set Class M2
(Res.= 100 mg) NOM-010-SCFI
2 000 mg to 30 000 g (7.8 x 10-1 + 2.05 x 10-4Wt) g SMMM-001
(Res.= 500 mg)
5 g to 30 000 g (1.6 + 1.83 x 10-4Wt) g
(Res.= 1 g)
20 g to 30 000 g (7.8 + 8.63 x 10-5Wt) g
(Res.= 5 g)
50 g to 60 000 g (16 + 9.33 x 10-5Wt) g
(Res.= 10 g)
100 g to 150 000 g (31 + 2.2 x 10-3Wt) g
(Res.= 20 g)
200 g to 300 000 g (78 + 8.7 x 10-5Wt) g
(Res.= 50 g)
2 000 g to 150 000 0 g (780 + 5.6 x 10-6Wt) g
(Res.= 500 g)
Compression and Tension- 1 kN to 10 kN 0.1 % of reading Load Cells and Mass
Source Weights M1
(Dynamometer)FO NMX-CH-7500-1-IMNC
SMMFA-004

Thermodynamic
MEASURED INSTRUMENT, RANGE OR NOMINAL CALIBRATION CALIBRATION
QUANTITY OR GAUGE DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Liquid in Glass -20 °C to 250 °C 0.18 °C Stirred Liquid Bath,
ThermometersF Thermometer Digital
Bi-Metal ThermometersF -20 ºC to 250 ºC 0.18 °C PT100
Digital ThermometersF 20 ºC to 100 ºC 0.27 ° C SMMTA-001
Infrared ThermometerFO 30 °C to 250 ° C 0.18 °C Fluke 725 with RTD
pt100, Black Body

Issue 01/2021 This supplement is in conjunction with certificate #L22-51 Page 6 of 8


Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Ing. Manuel Rodríguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:


SMMTA-002
Thermohygrometer 10 % RH to 90 % RH ± 1.5 % RH CEM Model DT-321S
Humidity OnlyF Thermohygrometer
Technical Guide CENAM
Thermogygometer -10 ˚C to 60 ˚C ± 0.20 °C CEM Model DT-321S
Temperature OnlyF Thermohygrometer
Technical Guide CENAM

Electrical
MEASURED RANGE OR NOMINAL CALIBRATION CALIBRATION
INSTRUMENT, DEVICE SIZE AS AND MEASUREMENT EQUIPMENT AND
QUANTITY OR GAUGE APPROPRIATE CAPABILITY EXPRESSED REFERENCE
AS AN UNCERTAINTY (±) STANDARDS USED
Temperature Calibration -200 °C to 0 °C 0.9 °C Fluke 725
Indication, and Control 0 °C to 950 °C 0.7 °C Electrical Simulation of
Equipment used with Thermocouple Output
Thermocouple Type EFO SMMTE-001
Temperature Calibration -200 °C to 0 °C 1 °C
Indication, and Control 0 °C to 1 200 °C 0.7 °C
Equipment used with
Thermocouple Type JFO
Temperature Calibration -200 °C to 0 °C 1.2 °C
Indication, and Control 0 °C to 1 300 °C 0.8 °C
Equipment used with
Thermocouple Type KFO
Temperature Calibration -20 °C to 1 750 °C 0.8 °C
Indication, and Control
Equipment used with
Thermocouple Type SFO
Temperature Calibration, -200 °C to 0 °C 1.2 °C Fluke 725
Indication and Control 0°C to 300 °C 0.8 °C Electrical Simulation of
Equipment used with RTD RTD Output
Type Pt 100FO SMMTE-001

1. The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of
accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing
a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically
expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual
measurement uncertainty associated with a specific calibration performed by the laboratory will typically
be larger than the CMC for the same calibration since capability and performance of the device being
calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to
some degree.

Issue 01/2021 This supplement is in conjunction with certificate #L22-51 Page 7 of 8


Certificate of Accreditation: Supplement
Sistemas de Medición Meril, S.A. de C.V.
Volcán Ajusco No. 502, Colonia El Collí Urbano
Zapopan, Jalisco, México. CP. 45070
Contact Name: Ing. Manuel Rodríguez Phone: 333-620-1514

Accreditation is granted to the facility to perform the following calibrations:


2. The laboratories range of calibration capability for all disciplines for which they are accredited is the
interval from the smallest calibrated standard to the largest calibrated standard used in performing the
calibration. The low end of this range must be an attainable value for which the laboratory has or has access
to the standard referenced. Verification of an indicated value of zero in the absence of a standard is
common practice in the procedure for many calibrations but by its definition it does not constitute
calibration of zero capacity.
3. The presence of a superscript F means that the laboratory performs calibration of the indicated parameter at
its fixed location. Example: Outside Micrometer F would mean that the laboratory performs this calibration
at its fixed location.

4. The presence of a superscript O means that the laboratory performs calibration of the indicated parameter
onsite at customer locations. Example: Outside Micrometer O would mean that the laboratory performs this
calibration onsite at the customer’s location.
5. The presence of a superscript FO means that the laboratory performs calibration of the indicated parameter
both at its fixed location and onsite at customer locations. Example: Outside Micrometer FO would mean that
the laboratory performs this calibration at its fixed location and onsite at customer locations.

6. Measurement uncertainties obtained for calibrations performed at customer sites can be expected to be
larger than the measurement uncertainties obtained at the laboratories fixed location for similar
calibrations. This is due to the effects of transportation of the standards and equipment and upon
environmental conditions at the customer site which are typically not controlled as closely as at the
laboratories fixed location.
7. The term L represents length in inches or millimeters as appropriate to the uncertainty statement.
8. The term P represents pressure in units appropriate to the uncertainty statement.
9. The term Wt represents weight in pounds or grams (including SI multiple and submultiple units)
appropriate to the uncertainty statement.

Issue 01/2021 This supplement is in conjunction with certificate #L22-51 Page 8 of 8