TAIL NUMBER - MSN - FSN: VT-SCM - 03620 - 908
WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYG
EN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF TH
E OXYGEN SYSTEM.
CAUTION: BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS A
RE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
QT
REFERENCE DESIGNATION
Y
C. Referenced Information
REFERENCE DESIGNATION
Ref. 24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External Power
Ref. 24-41-00-861-002-A01 Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02 Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from the Externa
l Power
Ref. 24-41-00-862-002-A01 De-energize the Aircraft Electrical Circuits Supplied from the APU
Ref. 24-41-00-862-002-A02 De-energize the Aircraft Electrical Circuits Supplied from the Engine
1(2)
Ref. 35-00-00-860-001-A Special Precautions When Working on a Gaseous Oxygen System
Ref. 52-41-00-010-002-A Open the Avionics Compartment Doors for Access
Ref. 52-41-00-410-002-A Close the Avionics Compartment Doors after Access
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
3. Job Set-up
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
SUBTASK 35-10-00-010-058-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position below access door 812.
(2) Open access door 812 Ref. AMM TASK 52-41-00-010-002.
(3) Fully close the valve of the oxygen storage cylinder (5750HM).
(4) Put the WARNING NOTICE(S) in position to tell persons not to open the valve of the oxygen stora
ge cylinder (5750HM).
** ON A/C FSN ALL
SUBTASK 35-10-00-865-053-A
B. Make sure that this (these) circuit breaker(s) is (are) closed:
(a) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU, p
ush the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(b) Put a WARNING NOTICE(S) in position to tell persons not to release the CREW SUPPLY pus
hbutton switch.
(c) On one oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control l
ever.
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regul
ator.
1 Keep them pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and
the volume of the sound of the oxygen flow decreases.
(d) When the flow rate indicator is black and when you no longer hear the sound of the oxygen
flow:
- Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control lever.
(e) Make sure that the PRESS TO TEST/EMERGENCY knob is not in the EMERGENCY position.
If it is in the EMERGENCY position, there can be a leak of oxygen.
** ON A/C FSN ALL
4. Procedure
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
Ref. Fig. REGUL LO PR Indication
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
SUBTASK 35-10-00-720-050-A
A. Check of the LP Oxygen of the Crew Oxygen Cylinder
(1) Remove the blanking cap from the oxygen-system test-port 5755HM.
(2) Connect the GAGE 10 BAR (145 PSI) - PRESSURE to the COUPLING-OXYGEN QUICK DISCONNECT
(110111-03) or COUPLING (802857-01) or equivalent.
(3) Connect the COUPLING-OXYGEN QUICK DISCONNECT (110111-03) or COUPLING (802857-01) or
equivalent to the oxygen-system test-port 5755HM.
(4) Fully open the valve of the oxygen storage cylinder 5750HM.
(5) Make sure that the pressure on the pressure gage is more than 50 psi (3.45 bar).
(6) Fully close the valve of the oxygen storage cylinder 5750HM.
(7) Bleed the oxygen system:
(a) On one oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control l
ever.
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES REVISION DATE REVISION NUMBER TITLE
AIC A318 A319 A321 A320 AMM 01-Feb-2024 16 35-10-00-040-002-A - Loss of REGUL LO PR Indication
TAIL NUMBER - MSN - FSN: VT-SCM - 03620 - 908
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regul
ator.
1 Keep them pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and
the volume of the sound of the oxygen flow decreases.
(b) When the flow rate indicator is black and when you no longer hear the sound of the oxygen
flow:
- Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control lever.
(c) Make sure that the PRESS TO TEST/EMERGENCY knob is not in the EMERGENCY position.
If it is in the EMERGENCY position, there can be a leak of oxygen.
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
SUBTASK 35-10-00-020-050-A
B. Disconnect the Test Installation
(1) Remove the COUPLING-OXYGEN QUICK DISCONNECT (110111-03) or COUPLING (802857-01) or e
quivalent from the oxygen-system test-port 5755HM.
(2) Remove the GAGE 10 BAR (145 PSI) - PRESSURE from the COUPLING-OXYGEN QUICK DISCONNE
CT (110111-03) or COUPLING (802857-01) or equivalent.
(3) Put the blanking cap on the oxygen-system test-port 5755HM.
** ON A/C FSN ALL
5. Close-up
** ON A/C FSN 002-050, 101-150, 201-300, 501-550, 901-950
SUBTASK 35-10-00-860-062-A
A. Put the aircraft back to its initial configuration.
(1) In the cockpit, on the OXYGEN section of overhead control and indicating panel 21VU, release the
OXYGEN/CREW SUPPLY pushbutton switch (the OFF legend comes on).
(2) De-energize the aircraft electrical circuits
Ref. AMM TASK 24-41-00-862-002.
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Fully open the valve of the oxygen storage cylinder (5750HM).
(5) Remove the WARNING NOTICE(S).
(6) Close access door 812 Ref. AMM TASK 52-41-00-410-002.
(7) Remove the access platform(s).
(8) Make an entry in the logbook.
A
A Z115
FR16
FR9
5750HM
5755HM
N_MM_351000_4_AAM0_01_00