You are on page 1of 8

LX10F10B series

Construction: Outside view

Ventilator Access Panel

C-BOX

Valve chamber

Inverter Box Compressor Chamber


Construction: Inside view

Humidity Sensor
(HuS : Option) Evaporator Inlet
temperature Sensor (EIS)

Return air Sensor (RS)


RS for Data recorder
(DRS : Option)
USDA1

USDA2
USDA3 Evaporator Outlet
temperature Sensor (EOS)
CTR
RPP2
Suction air temperature
USDA Sensor Receptacle (Option) Sensor (SS)
SS for Data recorder
(DSS)
Construction: Compressor Chamber

Low Pressure
Transducer
(LPT)

Suction Gas DCHS2


temperature (Rear of
Sensor (SGS) Compressor)

Ambient
temperature
Sensor
(AMBS)
Receiver
High
Pressure
Transducer
(HPT)

High
Pressure
Discharge gas temperature Inverter Compressor Sensor
(HPS)
Sensor 1 (DCHS1)
Construction: Valve Chamber

Drier Discharge Modulation Valve (DMV)

Hot gas Solenoid Valve (HSV)

Reheat Solenoid Valve (RSV)

Economizer Inlet temperature Sensor


(ECO-IN)

Electronic Expansion Valve (EEV)

Economizer

Economizer Modulation Valve (EMV)

Pressure Release Valve (PRV)

Economizer Outlet temperature


Sensor (ECO-OUT)

Economizer Solenoid Valve (ESV)

Liquid line Solenoid Valve (LSV)


Construction: Sensor Mounting Position

RS/DRS
Hus

Eco in
EIS
EFM Valve chamber
Evaporator
EOS
EEV
SS/DSS Reheat coil (option)

EMV Economizer
Eco out

PRV ESV
HSV RSV

CFM
LPT
DM
SGS HPT Condenser LSV Drier
V
Receiver
HPS
DCHS2 Sight
glass
Compressor

AMBS
DCHS1
Construction: Inverter Box

AC Reactor

Noise Filter Board Inverter Board


(EC9) (EC8)
Construction: Control Box Layout

Magnetic Contactor
CPU Board (EC1)
EFH EFL CFH CFL

Phase
Correction
Contactor 1
(PCC1)

USB port
Phase
Correction
Contactor 2
(PCC2)

Circuit Breaker
(C/B)

LED output
indicator
RCD(Option)
Control Circuit
Earth Terminal Block I/O Board (EC2)
Installation position
Transformer Battery
(Tr1: Behind C/B) PT/CT Board (EC7)
(Rechargeable 7.6V)