You are on page 1of 10

Hitch LW 1/1

◆ Load Sensor

Controller
Load Setting (GR1) 2/1

◆ Parameter (PTM)

◆ M1-1-3-1-1 (GO ON)

LW-TYP
3>

◆ M2-3-1 (GOON)

Load Weight Type


1>
Load Setting (GR1) 3/1

◆ LWD-K

OTIS KOREA LWB2


KA30925AAC

Status=1 Event=2
Setup =3 Calib=4
Load Setting (GR1) 4/1

Status=1 Event=2 1 Load =1 Sensor=2 1

Setup =3 Calib=4 Comm =3 Switch=4

GO ON
004% 0054Kg Z:0824 H:0700
003H Sens detect > F:0580 Set:0007

PTM quantity
1  1 EA, 3  2 EA Z : 0% Data , H : 50% Data
F : 100% Data
Set : 3  0% & 100%, 7  0%, 50%, 100%
Load Setting (GR1) 5/1

Load =1 Sensor=2 2 #1=0800 #2=0800


Comm =3 Switch=4 #3=0000 #4=0000

#1  First PTM
#2  Second PTM
800  Normal condition under no load
Load Increase  Data Decrease
Load Setting (GR1) 6/1

Load =1 Sensor=2 4 Discrete I/O : 0F


Comm =3 Switch=4 Dip Switch : 00

0F  0%
0E  20%
0C  60 %
08  80%
07  110%
Load Setting (GR1) 7/1

Status=1 Event=2 3 00 Active Sensor


Setup =3 Calib=4 01H New > H >

Input  PTM quantity


1  1 EA, 3  2 EA
Shift + Enter
7  3 EA, 0F  4 EA

GO ON GO ON
01 Zero Load kg 02 Full Load kg
0000 new > > 1000 new > >
No Load  By kg Full Load  By kg
Input  0 & Shift + Enter Input  1000 & Shift + Enter
Load Setting (GR1) 8/1

Status=1 Event=2 4 Zero Load = 1


Setup =3 Calib=4 Full Load = 2 >

1  No Load
2  Full Load
3  Half

1 Shift + Enter
Zero Load set Zero Load set
Clear Weight! > On going
In Car  0% (Empty) [Wait]

Zero Load set


SUCESSFUL
Load Setting (GR1) 9/1

Zero Load = 1 2 Full Load Set


Full Load = 2 > Upload Weight! >

In Car  100%

Shift + Enter
Full Load set [Wait] Full Load set
On going SUCESSFUL
Load Setting (GR1) 10 / 1

◆ M2-1-3

You might also like