You are on page 1of 4

Countermeasure Assurance Report

MDL VDR QTY OCC.DT 4M STATUS


PROBLEM CONSOLE UPPER COVER (AT) LHD- WRONG MARKING ISSUE
HCI NSI 6 16/06/2020 MAN CLOSED

Defect details Before After

WRONG MARKING IN PART WRONG MARKING MARKING DONE ON B SURFACE

Cause Countermeasure Defect Trend

Occurrence: Temporary:
WHY1- Marking done on A surface of the part. All parts are inspected 100%. 5
WHY2- New operator not trained properly. Quality alert has been displayed near the 4
machine area. 3
Training awareness given to the operator.
2
Detection Occurrence: 1
1
Improper inspection at inspection stage. 0 0 0
0
Failed to detect the defect by the operator and Education given to inspectors about FEB MAR APR MAY
inspector. appearance standard based inspection and QTY
Process flow
about the defect .

IMG REWORK PDI DISPATCH

Report Temp Dt Final EPI Study By Approval Confirmation Date


CM Status VENDOR Mr.Sams Mr. TRAI
16/06/20 17/06/20
on Vignesh
TRAINING GIVEN TO THE OPERATOR-IMAGE